• Title/Summary/Keyword: 팽창장치

Search Result 206, Processing Time 0.031 seconds

A Study on the Characteristics of Refrigeration System Installed with Precooler, and Liquid-Vapor Separator after Expansion Device (과냉각기와 팽창장치 후 액기분리기를 적용한 냉동시스템 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • The purpose of research is to understand the characteristics of refrigeration system having a liquid-vapor phase separator after expansion device and precooling heat exchanger. After expansion process of typical refrigerant of freezer, R134a, the cold vapor of the expanded refrigerant mixture is separated in the liquid-vapor separator and introduced in the precooling heat exchanger to enable the liquid refrigerant to be subcooled. The analysis results showed that the increasing rate of refrigeration capacity and COP can be 8.6% and 1.4%, each. The cause of these performance improvements is due to the difference of the slope of saturated vapor and saturated liquid lines in Mollier diagram of refrigerant.

Characteristic Study of Micro-Nozzle according to the Ratio of Nozzle Expansion and Specific heats (노즐 팽창비와 비열비에 따른 마이크로 노즐의 특성연구)

  • Oh Hwayoung;Huh Hwanil;Moon Seonghwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.381-385
    • /
    • 2005
  • Recently, spacecraft technology trends can be expressed three words, i.e. 'faster, cheaper and smaller'. Among these systems, micro propulsion device is an essential component. Also micro nozzle is the most important part in the micro propulsion device. In case of cold-gas thruster, micro nozzle converts the stored energy in a pressurized gas into kinetic energy through expansion ratio. In this paper we report characteristics of micro nozzle with throat expansion ratio and ratio of specific heats. We measure thrusts using strain gauge based thrust measurement system. We can estimate the micro nozzle performance through experiments.

  • PDF

Performance of an inverter refrigeration system with a change of expansion devices (인버터형 냉동시스템의 팽창장치 변경에 따른 성능특성)

  • 이용택;김용찬;박윤철;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.928-936
    • /
    • 1999
  • An experimental study was performed to investigate characteristics of an inverter driven water-to-water refrigeration system with a variation of compressor frequencies and expansion devices. The frequency of a compressor varied from 30Hz to 75Hz, and performance of the systems applying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve(EEV) were measured. The load conditions were altered by varying the temperature of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test conditions were deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimum control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in an inverter refrigeration system due to active control of flow area with a change of compressor frequency and load conditions.

  • PDF

Comparison of refrigerant flow through capillary with short tube orifice (모세관과 오리피스 팽창장치의 냉매유량 조절특성의 비교)

  • 김용찬;최종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.118-128
    • /
    • 1998
  • Capillary and short tube orifice have been widely used as an expansion device in refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which can predict properties along a tube and flow rate through a tube, was developed by assuming homogeneous two-phase flow, A semi-empirical flow model that can be used to evaluate the flow rate through a short tube orifice was also developed by summarizing the experimental data. Finally, the results of the numerical model for capillaries were compared with those of the semi-empirical model for short tube orifices to verify dominant flow factors for the expansion devices.

  • PDF

The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions (냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향)

  • 최은수;김종배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

Experimentation and Modeling of R32/125/134a Flow Through Short Tube Orifices (R32/125/134a를 사용한 오리피스 팽창장치의 성능실험 및 모델링)

  • 김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.45-54
    • /
    • 1996
  • An experimental investigation on the two-phase flow through tube orifices was performed with the refrigerant mixture of R32/125/134a(30/10/60). A series of tests were conducted to generate wide range of data at varying operation conditions with four short tubes. The tests include both single and two-phase flow conditions at the inlet of the short tube with different oil concentrations. Experimental data were presented as a function of major operating parameters and short tube diameter. Based on test results and data analysis, a semi-empirical flow model was developed to predict the mass flow rate through short tube orifices with a given set of conditions. The flow model was formed to cover both single and two-phase flow at the inlet of short tube with considering the effects of oil concentration.

  • PDF

A Study on the Characteristics of the Refrigerator Using a Refrigerant Injection Type Expansion Device (냉매분사식 팽창장치를 적용한 냉동기의 특성에 관한 연구)

  • 조병옥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.925-931
    • /
    • 2000
  • Refrigerating ability of vapor compression refrigerator is decided by the harmonic work of it's components such as compressor, condenser, evaporator, expansion device, and so on. In this study, choosing refrigerant injectors as a new one of expansion device, temperature change of the cold room, ice freezing ability, and power consumption on flowrate of injector and refrigerant charging condition are evaluated experimentally. As the results of this study, it is verified that the spray injection type refrigeration system has some merits according to the flowrate and spray pattern of injector and charging quantum of refrigerant. And there are some design factors such as spray pattern and shape of spray chamber to utilize and fabricate this refrigerant injection type refrigerator.

  • PDF

Study on the Adaptiveness of Using an Injector As an Expansion Device of Refrigerator (냉동기 팽창장치로서 인젝터 사용의 적합성에 관한 연구)

  • Cho, B.O.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.1-8
    • /
    • 2000
  • Spray as a liquid atomization technique has wide applications of combustion, painting, chemical, medical and agricultural purpose, and so on. Capillary tubes and expansion valves, as an expansion device of vapor compression type refrigerators, has been used from the early time. But there are some problems in practice, the former can't control refrigerant flowrate exactly and the later most of imported are expensive relatively and has some difficulties to install. Choosing an injector as a new concept of expansion device of refrigerator in this study to improve such troubles of the coming expansion device, the refrigerant spray behavior and refrigeration characteristics are evaluated experimentally. It is verified that the injector with a good function of refrigerant atomization plays a desirable role of refrigerant expansion in the actual refrigeration cycle.

  • PDF