• Title/Summary/Keyword: 팬 성능시험

Search Result 41, Processing Time 0.044 seconds

The Study on Performance Model of Open Rotor Engine for Next Generation Aircraft (차세대 항공기용 Open Rotor 엔진 성능 모델 연구)

  • Choi, Won;Kim, Ji-Hong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.842-849
    • /
    • 2011
  • Open Rotor Engine is one of the several new technologies offering potential solution for the next generation aircraft. The coupling of ultra high bypass ratio and aerodynamically advanced fan blade design allow the open rotor engine to achieve and advantage in fuel consumption. The open rotor engine does have more thrust lapse than the general high bypass turbofan. The open rotor engine performance model was analyzed using a reference data based on the GE36 which was designed and tested data at which time a F404 turbojet was used as the core. The performance model of open rotor engine was verified by referred test data and was evaluated to be properly constructed, through the comparison of recent Next generation turboprop engine performance.

  • PDF

Improvement in flow and noise performances of small axial-flow fan for automotive fine dust sensor (차량용 미세먼지 센서용 소형 축류팬의 유동과 소음 성능 개선)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Inhiug Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.7-15
    • /
    • 2023
  • Recently, as interest in air quality in vehicles increases, the use of fine dust detection sensors for air quality measurement is becoming common. An axial-flow fan is inserted in the fine dust sensor installed in the air conditioning system in the vehicle to prevent dust from sinking directly on the sensor. When the sensor operates, the flow noise caused by the rotation of the axial-flow fan acts as a major noise source of the fine dust sensor. flow noise is recognized as one of the product competitiveness of fine dust sensors. In this study, the noise was gradually reduced at the same flow rate by improving the flow performance of the small axial flow fan. First, a virtual fan performance tester consisting of about 20 million grids was developed to analyze the aerodynamic performance of the target small axial-flow fan. In addition, the flow field was simulated by using compressible Large Eddy Simulation for direct computation of flow noise as well as high-accurate prediction of flow rate. The validity of numerical method are confirmed through the comparison of predicted results with experimental ones. After the effects of pitch angle on flow performance were analyzed using the verified numerical method, the pitch angle was determined to maximize the flow rate. It was found that the flow rate was increased by 8.1 % and noise was reduced by 0.8 dBA when the axial-flow fan with the optimum pitch angle was used.

Improvement in flow and noise performance of backward centrifugal fan by redesigning airfoil geometry (익형 형상 재설계를 통한 후향익 원심팬의 유동 및 소음성능 개선)

  • Jung, Minseung;Choi, Jinho;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-hoon;Koo, Junhyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.555-565
    • /
    • 2021
  • The goal of this study is to improve flow and noise performances of existing backward-curved blade centrifugal fan system used for circulating cold air in a refrigerator freezer by optimally designing airfoil shape. The unique characteristics of the system is to drive cold airflow with two volute tongues in combination with duct system in a back side of a refrigerator without scroll housing generally used in a typical centrifugal fan system. First, flow and noise performances of existing fan system were evaluated experimentally. A P-Q curve was obtained using a fan performance tester in the flow experiment, and noise spectrum was measured in an anechoic chamber in the noise experiment. Then, flow characteristics were numerically analyzed by solving the three-dimensional unsteady Navier-Stokes equations and noise analysis was performed by solving the Ffowcs Williams and Hawkins equation with input from the flow simulation results. The validity of numerical results was confirmed by comparing them with the measured ones. Based on the verified numerical method, blade inlet and outlet angles were optimized for maximum flow rate using the two-factor central composite design of the response surface method. Finally, the flow and noise performances of a prototype manufactured with the optimum design were experimentally evaluated, which showed the improvement in flow and noise performance.

Measurement Uncertainty Assessment of Altitude Performance Test for a Turboshaft Engine (터보샤프트 엔진 고공성능시험의 측정 불확도 평가)

  • Yang, In-Young;Lee, Bo-Hwa
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.59-64
    • /
    • 2010
  • Measurement uncertainty assessment was performed for altitude performance test for a turboshaft engine. Mathematical models of measurement were suggested for major performance parameters such as shaft horse power, fuel flow, specific fuel consumption, and airflow. The procedure was compared with the test of turbojet or turbofan engines. Uncertainty involved with the test condition measurement was assessed. Influence of the test condition measurement uncertainty on the corrected performance data was discussed. Uncertainty assessment result was provided for a example test case using a real altitude test facility. For major performance parameters, measurement uncertainties were assessed as 0.65~1.09% including the test condition measurement uncertainty, 0.36~0.94% not including it.

헬리콥터용 반토오크 시스템 1차 시제 성능시험

  • Song, Keun-Woong;Kang, Hee-Jung;Sim, Joung-Wook;Lee, Je-Dong;Kim, Seung-Bum
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.50-59
    • /
    • 2005
  • This paper described performance test of 1st prototype "Tail-Fan" system. KARI(Korea Aerospace Research Institute) developed "Tail-Fan" system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. And natural frequencies of fan blade and test-rig were measured respectively. To find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, rotational speed for Tail-Fan performance test to avoid a resonance were found and performance tests were carried out in flight conditions. We analyzed test data by non-dimensionalization. Through this results, 1st prototype "Tail-Fan" system was satisfied with design requirements.

  • PDF

Experimental Study of Cooling Fan Performance Analysis and Shroud Characteristics for an Excavator (굴삭기 냉각팬 성능해석 및 슈라우드 특성에 대한 실험적 연구)

  • Lee, Jae-Seok;Chung, Kyung-Nam;Kim, Jin-Young;Lee, Tae-Kyung;Kang, Jeong-Won;Shim, Jae-Koo;Son, Deuk-Kyun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2597-2602
    • /
    • 2007
  • In this paper, the performance analysis is experimentally carried out in order to select the best cooling fan and shroud considering both cooling performance and noise reduction. 4 cooling fans have been tested in the fan tester and the real excavator. In order to obtain the performance of the cooling fans, flow capacity has been estimated by measuring flow velocity using a hot wire anemometer, and noise radiation has been also measured to estimate the fan noise. Characteristics of a box-type and a streamlined shroud have been examined by changing the immersion depth of cooling fans. Based upon the results, the best cooling fan is selected. Finally, the criterion to select the best cooling fan has been set up.

  • PDF

Experimental and Numerical Studies on the Flow Characteristics of a Fan-Sink (팬싱크의 유동 특성에 관한 실험 및 수치해석적 연구)

  • Lee Kyoung-Yong;Choi Young-Seok;Yun Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • The overall performance and local flow fields of the fan, heat sink, and fan-sink were experimentally and numerically studied to investigate the flow characteristics of a fan-sink. The flow resistance of the heat sink was measured by small fan tester based on AMCA standards and compared with the CFD results to select available cooling fan for the fan-sink. The nonuniform velocity profile behind the fan outlet was shown by the flow visualization. The effects of nonuniform velocities on the performance of heat sink were discussed. To validate the commercial CFD code CFX-5.6, the predicted performance curve was compared with that of fan testing. The local flow fields of the fan-sink were analyzed by CFD results. MFR (multiple frame of reference) was used as a computational model combining rotating fan and stationary heat sink. Through the CFD results of the fan-sink, the flow patterns behind the fan outlet influenced the flow resistance and overall performance of the heat sink.

A Study on the Calculation of Turbofan Engine Installed Performance for a Supersonic Aircraft (초음속 항공기에 장착되는 터보팬엔진의 장착성능산정에 관한 연구)

  • 김원철;김지현
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.3
    • /
    • pp.1-7
    • /
    • 2002
  • During the preliminary design phase of aircraft development, it is necessary to evaluate many potential engine/airframe combinations to determine the best solution to given set of mission requirements and it is very important to establish a methodology to calculate precisely engine installed performance. It was carried out to calculate turbofan engine installed performance of a supersonic aircraft for a given engine/aircraft configuration. Thus "Thrust minus drag accounting system" was introduced to identify and calculate the elements of installed thrust or installed propulsive force by using the database based on wind tunnel test data. This paper describes the calculated results of installed thrust of turbofan engine for a supersonic aircraft. aircraft.

Development of BLDC Controller for Automotive Cooling Fan (자동차 쿨링 팬용 BLDC 제어기 개발)

  • Seo, Dong Hyun;Hyon, Byong Jo;Park, Joon Sung;Kim, Jin-Hong;Choi, Jun-Hyuk
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.391-392
    • /
    • 2017
  • 최근 자동차 산업의 연구개발의 핵심화두는 효율성 제고 및 NVH(Noise, Vibration, Harshness) 개선에 있다. 특히나 많은 부품들의 개발에 있어서 운전자의 운전 편의성을 높이는 성능적인 지표 외에도 운전자가 느끼는 소음, 이상 진동에 대한 감성성능에 대한 소비자의요구도 높아지고 있다. 이러한 경향에 맞추어 자동차 각 부분의 소음저감, 효율향상을 고려한 설계에 대한 연구가 활발해지고 있다. 많은 자동차 부품들에 모터가 사용되고 있으며, 특히 차량용 쿨링팬의 경우 모터를 사용하여 차량 운행 시 발행하는 (배터리의 온도를) 적절한 수준으로 유지시켜주거나 친환경 자동자차 배터리를 쿨링 하는 역할을 한다. 대다수의 쿨링팬 모터로 BLDC모터가 많이 사용되며 이는 전통적인 제어 방법인 구형파제어를 사용하고 있다. 본 논문에서는 저전압 배터리의 전원을 사용하여 BLDC 쿨링팬을 안정적으로 구동할 수 있는 제어기를 개발하였고, 소음저감 및 높은 효율을 위하여 정현파로 제어하는 기법을 적용하였다. 개발된 시작품의 성능 시험을 통해 그 결과를 검증하였다.

  • PDF

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.