• Title/Summary/Keyword: 패밀리 금형

Search Result 6, Processing Time 0.017 seconds

A Theoretical Study for the Filling Balance of the Family Mold Using Variable-Runner System (가변 러너 시스템을 이용한 패밀리 금형의 충전밸런스에 관한 이론적 연구)

  • Choi, Kwon-Il;Park, Hyung-Pil;Cha, Baeg-Soon;Rhee, Byung-Ohk;Koo, Bon-Heung
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.275-278
    • /
    • 2007
  • In family mold, defects are frequently occurred by an excessive packing the smaller volume cavity during molding. Although runner size could be optimized by CAE analysis or experimental data, the filling imbalance is hardly avoided in the actual injection molding process by various means. Before this study, we developed a variable-runner system for balancing the cavity-filling for three resins (ABS, LDPE, and PA66) in the family-mold, and examined the effect of cross-sectional area reduction of a runner in the system. In this study, we examined the conditions of the pressure and temperature in the system with a CAE analysis. We also analyzed the influence of the rheological characteristic of resins to the balancing-capability of the system in order to help mold designers easily adopt the variable-runner system to their design.

  • PDF

A Study on Flow Balance and Cavity Pressure in Family Mold (FAMILY MOLD의 유동 밸런스와 금형 내압에 관한 연구)

  • 김태철;이대근;홍기복;김영근;박인수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.603-607
    • /
    • 2002
  • Cavity pressure is a factor of what is occurring inside the mold and is used as one of the process parameters that control the overall injection molding cycle. The insight of cavity pressure is able to predict part quality and optimum process condition. In this paper, it is adapted ejector pin sensor to measure the cavity pressure and investigates the flow balance and the cavity pressure according to different runner thickness for adjusting the flow balance. Flow balance is very important to have not the poor results such as flash and warpage in the family mold. This paper predicted flow balance and cavity pressure using CAE analysis tool and compared with the test results. The results of analysis and test have a good agreement with the cavity pressure profile and flow pattern of the test.

  • PDF

A Study on flow Balance and Warpage Characteristics in Manufacturing of Plastic Injection Family Mould (Family 금형 제작에서의 유동 밸런스 및 휨특성에 관한 연구)

  • Kim K. H.;Song D. J.;Kwon C. O.;Lee S. H.;Heo Y. M.;Kim M. Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.09a
    • /
    • pp.141-146
    • /
    • 2005
  • In the present study, the characteristic of warpage and flow balance for family mould, which is able to mold parts with different shapes in a mold, is considered. To obtain an optimal gate and runner system, plastic injection molding analysis with commercial code is performed. Design and manufacturing of family mould is then carried out on the basis of this computer aided engineering result. Flow balance and warpage comparisons between experiment and numerical analysis give good agreement with each other. However, it was shown that results of warpage measured by CMM was about $20\~55\%$ lower than those of numerical analysis.

  • PDF

Perfomance analysis of variable runner according to materials rheological characteristics in family mold (패밀리금형에서의 수지 유변학적 특성에 따른 가변러너의 성능 분석)

  • Choi, Kwon-Il;Park, Hyung-Pil;Cha, Baek-Soon;Lee, Byung-Ok;Gu, Bon-Heung
    • Design & Manufacturing
    • /
    • v.2 no.6
    • /
    • pp.23-27
    • /
    • 2008
  • It is well known that the family-mold has an advantage to reduce the cost for production and mold. However, defects are frequently occurred by over packing the smaller volume cavity during molding, especially when the family-mold has a volumetric difference between two cavities. In this study, the cavity-filling imbalance was confirmed by the temperature and the pressure sensors, and a variable-runner system was developed for balancing the cavity-filling. Experiments of balancing the cavity filling was carried out in the family-mold with the variable-runner system, and balancing the cavity-filling was confirmed by changing the cross-sectional area of a runner in the variable-runner system with the temperature and pressure sensors. The influence of the injection speed to the balancing-capability of the variable-runner system was also examined in the experiment.

  • PDF

Overflow Design Methods of Family Mold for Rotor Using the Flow and Solidification Simulation (유동 및 응고 시뮬레이션을 활용한 회전자 패밀리 금형의 오버플로우 설계 방안)

  • Jung, J.M.;Kim, C.W.;Nguyen, V.T.;Lee, K.M.;Kuk, J.M.;Jin, H.G.;Hong, S.K.
    • Journal of Korea Foundry Society
    • /
    • v.33 no.5
    • /
    • pp.204-209
    • /
    • 2013
  • The family mold casting have advantages which are able to make products with different shapes and dimensions simultaneously in a single mold. In this study, the design of the 4 cavity rotor family mold was used by "Anycasting" software, the defects occurred during die casting were predicted and suggested the best optimization conditions for sound products. The result of the experiment were that the optimum overflow design was needed for gas emission and control of residual oxides. It was clear that the defects positions formed by diecasting were agreed with nearly them predicted by simulation.

Study on Improving Flow Balance and Clamp Force of Family Mold for Refrigerator Shelf (냉장고용 선반 패밀리금형의 유동 밸런스와 클램프힘 개선에 관한 연구)

  • Park, Je-Hong;Yoon, Kyeong-Won;Ko, Chang-Oh;Seo, Sang-Won;Kim, Su-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.561-568
    • /
    • 2014
  • Injection molding industries realize the necessity of developing family molds to improve competitiveness. One of the primary causes of manufacturing defective products is the imbalance of flow in a family mold. In this study, the family mold of a shelf for refrigerators is analyzed by using CAE software. First, the flow balance, clamping force, and injection pressure are analyzed for different gate diameters of two cavities. Second, the flow balance, clamping force, and injection pressure are improved when the two gate valves are open at different times. Finally, the results of filling analysis are compared with the test injection product.