• Title/Summary/Keyword: 파형 구조

Search Result 408, Processing Time 0.029 seconds

Measurement on the Natural Frequency of a Laminated Cantilever Microbeam using a Laser Interferometer (레이저 간섭계를 이용한 적층 마이크로 외팔보의 고유진동수 측정)

  • Kim, Yun-Young;Han, Bong-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • The natural frequency of a laminated cantilever microbeam was studied in the present investigation. The microbeam was made of quartz on a silicon chip, and its top and bottom surfaces were coated with thin(~30nm) gold films. An ultrasonic testing platform was employed to resonate the microbeam, and its time domain signal was optically measured. The natural frequency was quantified through the fast Fourier transform of the waveform, and the result showed good agreement with a theoretical estimation from the classical beam theory. This study is expected to provide a dynamic evaluation technique for micro/nanoscale materials and micromechanical structures.

Experimental Study on Wave Transmission Coefficients of Submerged Structure : II. Rubble-Mound Type Structure armored by Tetrapods (수중구조물의 파고전달계수 산정 실험 : II. 테트라포드 피복 경사형 수중구조물)

  • Lee, Jong-In;Kim, Young Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.497-507
    • /
    • 2020
  • Two-dimensional laboratory experiments were conducted in a wave flume to investigate the wave transmission phenomena of rubble-mound type submerged structures armored with Tetrapods. Different experimental conditions were included by considering relative crest depth, relative freeboard, relative crest width, wave steepness, and so on. An empirical formula was proposed to predict the wave transmission coefficients over various specifications and structural designs of the partial perforated (rubble-mound) type submerged structure from the experimental results. The proposed formula successfully predicted the wave transmission coefficients. In this study, the proposed empirical formula of the wave transmission over the rubble-mound type submerged structure was improved from the existing formula.

Design of Standard Encoder for Health information in aviation emergency medical service (항공응급의료체계에서의 의료신호 표준 부호화기 설계)

  • Lee, Yong-Hee;Kim, Soon-Seok;Kim, Dong-Ho;Lee, Deok-Gyu;Jeong, Ho-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1173-1179
    • /
    • 2011
  • In this paper, we propose the parser structure to realize the encoder which is standardized encoding rules to code and store the medical waveform such as an electrocardiogram or an blood pressure in aviation emergency medical service. To design the encoder based on the MDER, the effect on the scope of each tag should be considered. we design the parser with the root property which is to clarify the effect of scope between tags. the presented parser is implemented and compared with the other structures.

A Study on the Measurement of Wall Shear Rate in the Abdominal Aortic Aneurysm (복부대동맥류 벽 전단변형률 측정에 관한 연구)

  • 오성은;이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.181-187
    • /
    • 2000
  • 동맥의 일부분이 팽창하는 동맥류는 파열로 인한 높은 사망률을 야기한다. 동맥류의 발생 및 파열에는 혈관벽의 구조적 약화와 혈류에 의한 응력이 중요한 역할을 하며, 혈류에 의해 혈관벽에 가해지는 전단응력은 간접적으로 혈관벽 구조를 변화시키고, 직접적으로 혈관벽에 응력을 가하므로 동맥류 파열에 영향을 미치는 중요한 혈류역학적 인자이다. 동맥류가 자주 발생하는 복부대동맥류 모델을 제작하여 정상류와 맥동류 유동에서 광색성 염료를 이용한 유동가시화 방법으로 벽 전단변형률을 측정하였다. 벽전단변형률은 동맥류 내부에서 감소하여 음의 값을 가지며, 동맥류 최대확장부 후부에서 다시 증가하여 확장부가 끝나는 위치에서 동맥 벽에 비해 약 1.5배 정도의 큰 전단변형률 값을 가졌다. 동맥류 최대확장부 후부에서는 벽전단변형률의 방향의 바뀌며, 위치에 따른 전단변형률의 변화가 크게 나타났다. 맥동류 유동에서는 동맥류의 위치에 따라 시간에 따른 벽전단형률 파형이 측정되었다. 동맥류 내부에서는 전단변형률의 크기가 작고 그 방향이 시간에 따라 변화가 심하였으므로 혈관벽의 구조변화가 발생하기 쉬운 지역으로 지목된다. 동맥류 최대 확장부 후부는 위치 및 시간에 따른 전단변형률의 변화가 심하며, 혈관벽 응력이 최대값을 갖는 지역이므로 동맥류의 파열이 발생하기 쉬운 지역으로 예측된다.

  • PDF

Structural dependence of the effective facet reflectivity in spot-size-converter integrated semiconductor optical amplifiers (모드변환기가 집적된 반도체 광증폭기에서의 유효단면반사율의 구조 의존성)

  • 심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.340-346
    • /
    • 2000
  • Traveling wave type semiconductor optical amplifiers integrated with spot-size-converter (SSC-TW-SOA) have been extensively studied for the improvement of coupling effiClency With single-mode fiber and fO! the cost reducClon 111 a packaging In tlIis paper the slructural dependence of the spot-slZe-converter on the effective facet reflectlvllY $R_{eff}$ was experimentally as well as thcoretienlly mvestlgated. It was shown that not only a sufficient mode-conversion in a sse region along the latersl and tran~verse directions but also an introductIOn of angled-facet were very essential in order to reduce $R_{eff}$ Very small ripple less than 0.1 dB in an amplified spontaneous emission spectrum was observed with the fabncated SSC-lW-SOA which consists of the wrndow length of $20\mu\textrm{m}$, facet angle of $7^{\circ}$, and antlrelleetioll-coated facet of ] % reflectivity.tivity.

  • PDF

Experimental Study on Wave Transmission Coefficients of Submerged Structures: III. Impermeable-Type Structure (수중구조물의 파고전달계수 산정 실험 : III. 불투과형 수중구조물)

  • Lee, Jong-In;Cho, Ji Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.593-601
    • /
    • 2020
  • Two-dimensional laboratory experiments were conducted in a wave flume to investigate the wave transmission phenomena of impermeable-type submerged structures armored by concrete blocks. Different experimental conditions were included by considering relative crest depth, relative freeboard, relative crest width, wave steepness, and so on. An empirical formula was proposed to predict the wave transmission coefficients over various specifications and structural designs of the impermeable submerged structure from the experimental results. The proposed formula successfully predicted the wave transmission coefficients. Therefore, in this study, the proposed empirical formula of the wave transmission over an impermeable submerged structure was improved from the existing formula.

Evaluation of Seismic Safety in School Buildings Applying Artificial Seismic Waves in Earthquake Magnitude of Korea (한국형 중진지역의 인공지진파 생성을 통한 학교건물 내진안전성 평가)

  • Kim, Seung-Hyun;Park, Young-Binuk;Kang, Jun-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • This report describes the development and stability evaluation of a seismic retrofit method to evaluate the seismic performance of existing school buildings by analyzing the earthquake waveforms that occurred in Korea. Currently, Facilities for seismic retrofit designed for excessive reinforcement are being applied. To compensate for this, optimised the retrofit mothod suitable for domestic situation considering the characteristics of the seismic region, generated a Korean-style artificial seismic wave that meets the seismic design criteria, which is less frequent than other countries.

Experiments for Amour Stability of Low Crested Structure Covered by Tetrapods (저 마루높이 구조물의 피복재 안정성 실험: Tetrapod 피복 조건)

  • Lee, Jong-In;Bae, Il Rho;Moon, Gang Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.769-777
    • /
    • 2019
  • Low crested coastal structures such as detached breakwaters and submerged breakwaters (artificial reefs) have been commonly used as coastal protection measures. The armour units of these structures are unstable than those in non-overtopped structure cases. The stability of low crested structures armoured by rock has been suggested in existing studies. In this study, the stability of Tetrapods armour units on theses structures has been investigated using two-dimensional hydraulic model tests. The effect of wave steepness and freeboard on the armour stability on crest, front, and the rear slope has been investigated. Armour units were mostly damaged near the upper part of the seaward slope and the crest of the seaward side. From the experimental data, the new empirical formula for the stability coefficients of the Tetrapods was proposed.

Hybrid TDMA and Binary CDMA System (TDMA와 Binary CDMA의 혼합 다중 접속 시스템)

  • 안호성;나성웅
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.527-536
    • /
    • 2004
  • A novel hybrid multiple access system, TD-BCDMA, where Binary CDMA that maintains a constant amplitude by clipping the summation of input signals multiplied by the orthogonal codes is transmitted over a TDMA frame structure, was Nosed. In every time slot of TDMA, binary CDMA modulated multiple channel signals are transmitted with the same waveform of TDMA. TD-BCDMA has all the advantages of TDMA. Flexible adjustment of the data transmission rate In demand is possible by adjusting the number of codes and time slots assigned to each user. This property was used to show an example of Ad Hoc network applications. To obtain a proper synchronization scheme for TD-BCDMA, the Receiver Operating Characteristics performance and the false alarm probability and false dismissal probability under various channel environment of two different schemes, a preamble scheme as in TDMA and a synchronization channel scheme as in CDMA were compared. It was proved that the preamble scheme is more practical and suitable than the synchronization channel scheme for the hybrid multiple access system.

Analysis of Load Distribution Behavior in Vertical Extension Remodeling from Stiffness of Existing and Reinforcing Pile by Load Test (현장 재하시험을 통한 수직증축시 기존 말뚝과 보강 말뚝의 강성에 따른 하중분담거동 분석)

  • Kim, Seok-Jung;Wang, Cheng-Can;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.8
    • /
    • pp.61-72
    • /
    • 2020
  • It is generally considered that differences of axial stiffness between exiting pile and reinforcing pile affect the load distribution ratio during vertical extension remodeling. But there are few cases to verify the effect of stiffness by field load test on load distribution ratio in Korea. In this paper, a series of load tests for micropiles were carried out to evaluate the effect of axial stiffness on the load distribution ratio. First, different types of micropiles were constructed so that conventional micropiles simulated existing piles and waveform micropiles simulated reinforcing piles. Secondly, load tests were performed to evaluate the stiffness of each piles. After then, the raft was installed to make a piled raft system and load tests were applied on foundation to verify the effect of axial stiffness on the load distribution ratio. The experimental results show that the stiffness of waveform micropiles were 2.5 times larger than that of conventional micropiles, and the load distribution ratio between existing and reinforcing piles was increased according to axial stiffness of piles.