• Title/Summary/Keyword: 파형

Search Result 2,910, Processing Time 0.04 seconds

Evaluation of Experimentally Induced Lumbar Spinal Cord Injury by Somatosensory Evoked Potentials(SEPs) in Dogs (개에서 Somatosensory Evoked Potentials (SEPs)을 이용한 척수기능장애의 평가)

  • Lee, Joo-Myoung;Jeong, Seong-Mok;Kweon, Oh-Kyeong;Nam, Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.315-323
    • /
    • 2001
  • Changes in somatosensory evoked potentials (SEPs) which accompanied by insertion of foreign body in spinal canal were evaluated with clinical signs and positive contrasted myelography in dogs. Foreign bodies occupied 20∼50% of spinal canal. Foreign bodies occupying about 50% of spinal canal were inserted into the animals of group II and III for 1 week and 2 days, respectively. Foreign bodies occupying about 20% of spinal canal were inserted into the animals of group IV, V, and for 1 week, 2 days, and 8 weeks, respectively. in group I (control group), sham operation (lateral laminectomy) was performed. Group III, IV and V did not severely affect on SEPs latencies and clinical signs. Group VI affects on SEPs latencies but not on clinical signs. After foreign body removal, SEPs latencies showed similar recovery patterns with clinical signs. However, group II induced severe abnormalities in SEPs latencies and clinical signs. In group III, IV and V, thoracic potentials (TN1) were abnormally recorded after foreign body insertion and firstly/normally recorded on the 6th 9.5th and 3.5th day after foreign body (removal following) insertion. In group VI, TN1 was abnormally recorded after foreign body insertion and firstly recorded on the 7.7th day and normally recorded on 34th day after foreign body insertion. In group I, TN1 was not recorded from the 3rd day after foreign body insertion and until the 8th week after foreign body removal. In group I, TN1 was firstly recorded on the 1st day after laminectomy.

  • PDF

The Site Effect of the Broadband Seismic Stations in Korea (국내 광대역 지진 관측소의 부지효과)

  • Wee, Soung-Hoon;Kim, Sung-Kyun
    • Economic and Environmental Geology
    • /
    • v.41 no.2
    • /
    • pp.225-242
    • /
    • 2008
  • The site effect for 23 broadband seismic stations in the southern Korean Peninsula was estimated by using the spectral ratio of coda waves. In principle, the site effect means the pure amplification below the station excluding effects of seismic source and attenuation in the wave transmission. However, the site effect determined in this study is equivalent with the relative site amplification factor to the mean amplification for all stations. A total of 500 three-component seismograms from 35 earthquakes, of which magnitude ranged from 2.5 to 5.1 occurred from January, 2001 to January, 2007 was used to obtain the site amplification factor. The site amplification factors were estimated for the frequency bands centered at 0.2, 0.5, 1, 2, 5, 10, 15, and 20 Hz. It was found that the factors for two horizontal components of transverse and radial records were concordant with each other in the all frequency bands. However, the factor for the vertical component was found to be systematically lower than those for two horizontal components. The factors obtained in the low frequency band below 2 Hz ranged from 0.5 to 1.5 in all seismic stations except for KMA and KIGAM stations in Bagryeongdo (BRD1 and BRD2) of which factor showed high value above 1.5. Some stations such as SEO, SNU, HKU, NPR, and GKPI showed high value above 1.5 in the high frequency band from 5 to 20 Hz. Especially, the factors of GKP1 station represented extremely high value ranging from 1.8 to 7.8. Also, the factors for stations of KWJ, SND, and ULJ showed low value below 0.5. The spatial distribution for the relative amplification factor represented a tendency of being approximately lower in north-eastern area than south-western area in the southern Korean Peninsula.

Synthetic Application of Seismic Piezo-cone Penetration Test for Evaluating Shear Wave Velocity in Korean Soil Deposits (국내 퇴적 지반의 전단파 속도 평가를 위한 탄성파 피에조콘 관입 시험의 종합적 활용)

  • Sun, Chang-Guk;Kim, Hong-Jong;Jung, Jong-Hong;Jung, Gyung-Ja
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.3
    • /
    • pp.207-224
    • /
    • 2006
  • It has been widely known that the seismic piezo-cone penetration test (SCPTu) is one of the most useful techniques for investigating the geotechnical characteristics such as static and dynamic soil properties. As practical applications in Korea, SCPTu was carried out at two sites in Busan and four sites in Incheon, which are mainly composed of alluvial or marine soil deposits. From the SCPTu waveform data obtained from the testing sites, the first arrival times of shear waves and the corresponding time differences with depth were determined using the cross-over method, and the shear wave velocity $(V_S)$ profiles with depth were derived based on the refracted ray path method based on Snell's law. Comparing the determined $V_S$ profile with the cone tip resistance $(q_t)$ profile, both trends of profiles with depth were similar. For the application of the conventional CPTu to earthquake engineering practices, the correlations between $V_S$ and CPTu data were deduced based on the SCPTu results. For the empirical evaluation of $V_S$ for all soils together with clays and sands which are classified unambiguously in this study by the soil behavior type classification index $(I_C)$, the authors suggested the $V_S-CPTu$ data correlations expressed as a function of four parameters, $q_t,\;f_s,\;\sigma'_{v0}$ and $B_q$, determined by multiple statistical regression modeling. Despite the incompatible strain levels of the downhole seismic test during SCPTu and the conventional CPTu, it is shown that the $V_S-CPTu$ data correlations for all soils, clays and sands suggested in this study is applicable to the preliminary estimation of $V_S$ for the soil deposits at a part in Korea and is more reliable than the previous correlations proposed by other researchers.

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Structural Behavior of the Buried flexible Conduits in Coastal Roads Under the Live Load (활하중이 작용하는 해안도로 하부 연성지중구조물의 거동 분석)

  • Cho, Sung-Min;Chang, Yong-Chai
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.323-328
    • /
    • 2002
  • Soil-steel structures have been used for the underpass, or drainage systems in the road embankment. This type of structures sustain external load using the correlations with the steel wall and engineered backfill materials. Buried flexible conduits made of corrugated steel plates for the coastal road was tested under vehicle loading to investigate the effects of live load. Testing conduits was a circular structure with a diameter of 6.25m. Live-load tests were conducted on two sections, one of which an attempt was made to reinforce the soil cover with the two layers of geo-gird. Hoop fiber strains of corrugated plate, normal earth pressures exerted outside the structure, and deformations of structure were instrumented during the tests. This paper describes the measured static and dynamic load responses of structure. Wall thrust by vehicle loads increased mainly at the crown and shoulder part of the conduit. However additional bending moment by vehicle loads was neglectable. The effectiveness of geogrid-reinforced soil cover on reducing hoop thrust is also discussed based on the measurements in two sections of the structure. The maximum thrusts at the section with geogrid-reinforced soil cover was 85-92% of those with un-reinforced soil cover in the static load tests of the circular structure; this confirms the beneficial effect of soil cover reinforcement on reducing the hoop thrust. However, it was revealed that the two layers of geogrid had no effect on reducing the overburden pressure at the crown level of structure. The obtained values of DLA decrease approximately in proportion to the increase in soil cover from 0.9m to 1.5m. These values are about 1.2-1.4 times higher than those specified in CHBDC.

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Studies on electrocardiogram of the normal Korean native cattle II. Wave forms and amplitudes of the unipolar precordial chest leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) II. 흉부단극유도(胸部單極誘導)의 파형(波形)과 전위(電位))

  • Choi, In-hyuk;Kim, Soo-young;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.735-746
    • /
    • 1993
  • Electrocardiographic parameters of amplitude and the shape of waves on the unipolar precordial chest leads in the normal Korean native cattles have been measured with a 3 channel electrocardiograph built in a computed and analysis. The study was conducted on 98 heads of mean age of 17.6 months. The wave forms of P, T and QRS complex wave in all leads showed various types. The parameters of the amplitude in the wave types showed the most frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of positive type showed a frequency of 92.9% and 93.9% in leads $CV_6LU$ and $CV_6LL$ that were $83.8{\pm}31.0{\mu}V$ and $76.0{\pm}30.7{\mu}V$, and negative type showed a frequency of 97.9% in lead V 10 that were $-80.2{\pm}29.4{\mu}V$, respectively. But the plate type in leads $CV_6RU$ and $CV_6RL$ showed frequency of 48% and 58.3%, respectively. 2. Average amplitude of the QRS complex were in a range of $277.0{\pm}154.0{\mu}V$ to $648.2{\pm}146.2{\mu}V$(mean of $418.8{\pm}139.4{\mu}V$) in all leads that were manifested the Low-Voltage QRS complex(below 1 mV in unipolar precordial leads). Average amplitudes of each wave type in the QRS complex were $-250.0{\pm}139.8{\mu}V$ and $-399.2{\pm}226.8{\mu}V$ in the QS group types that showed a frequency of 50.0% and 82.5% in the leads $CV_6LU$ and $CV_6LL$, respectively. And average amplitudes of the R group types showed a frequency of 85.6%, 56.1% and 75.8% in the $CV_6RU$, $CV_6RL$ and $V_{10}$ that were $321.5{\pm}142.1{\mu}V$, $271.6{\pm}139.9{\mu}V$ and $552.4{\pm}132.7{\mu}V$, respectively. 3. In T waves, Amplitudes of the positive type showed a frequency of 60.2%, 46.9% and 83.7% in leads of $CV_6LL$, $CV_6RU$ and $CV_6RL$ that were respectively $184.7{\pm}93.7{\mu}V$ $103.7{\pm}64.43{\mu}V$ and $111.8{\pm}39.3{\mu}V$, the negative type showed a frequency of 62.2% and 93.7% in leads $CV_6LU$ and $V_{10}$ that were $142.2{\pm}82.1{\mu}V$ and $-280.3{\pm}107.2{\mu}V$, respectively. 4. Average amplitude of ST segment were $3.7{\pm}33.1{\mu}V$, $0.9{\pm}23.1{\mu}V$, $10.9{\pm}28.6{\mu}V$, $5.8{\pm}28.3{\mu}V$ and $-34.7{\pm}48.4{\mu}V$ in leads $CV_6LL$, $CV_6RU$, $CV_6RL$, $CV_6LU$ and $V_{10}$ respectively.

  • PDF

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Analysis on dynamic numerical model of subsea railway tunnel considering various ground and seismic conditions (다양한 지반 및 지진하중 조건을 고려한 해저철도 터널의 동적 수치모델 분석)

  • Changwon Kwak;Jeongjun Park;Mintaek Yoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.583-603
    • /
    • 2023
  • Recently, the advancement of mechanical tunnel boring machine (TBM) technology and the characteristics of subsea railway tunnels subjected to hydrostatic pressure have led to the widespread application of shield TBM methods in the design and construction of subsea railway tunnels. Subsea railway tunnels are exposed in a constant pore water pressure and are influenced by the amplification of seismic waves during earthquake. In particular, seismic loads acting on subsea railway tunnels under various ground conditions such as soft ground, soft soil-rock composite ground, and fractured zones can cause significant changes in tunnel displacement and stress, thereby affecting tunnel safety. Additionally, the dynamic response of the ground and tunnel varies based on seismic load parameters such as frequency characteristics, seismic waveform, and peak acceleration, adding complexity to the behavior of the ground-tunnel structure system. In this study, a finite difference method is employed to model the entire ground-tunnel structure system, considering hydrostatic pressure, for the investigation of dynamic behavior of subsea railway tunnel during earthquake. Since the key factors influencing the dynamic behavior during seismic events are ground conditions and seismic waves, six analysis cases are established based on virtual ground conditions: Case-1 with weathered soil, Case-2 with hard rock, Case-3 with a composite ground of soil and hard rock in the tunnel longitudinal direction, Case-4 with the tunnel passing through a narrow fault zone, Case-5 with a composite ground of soft soil and hard rock in the tunnel longitudinal direction, and Case-6 with the tunnel passing through a wide fractured zone. As a result, horizontal displacements due to earthquakes tend to increase with an increase in ground stiffness, however, the displacements tend to be restrained due to the confining effects of the ground and the rigid shield segments. On the contrary, peak compressive stress of segment significantly increases with weaker ground stiffness and the effects of displacement restrain contribute the increase of peak compressive stress of segment.

The Clinical Features of Endobronchial Tuberculosis - A Retrospective Study on 201 Patients for 6 years (기관지결핵의 임상상-201예에 대한 후향적 고찰)

  • Lee, Jae Young;Kim, Chung Mi;Moon, Doo Seop;Lee, Chang Wha;Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.671-682
    • /
    • 1996
  • Background : Endobronchial tuberculosis is definded as tuberculous infection of the tracheobronchial tree with microbiological and histopathological evidence. Endobronchial tuberculosis has clinical significance due to its sequela of cicatrical stenosis which causes atelectasis, dyspnea and secondary pneumonia and may mimic bronchial asthma and pulmanary malignancy. Method : The authors carried out, retrospectively, a clinical study on 201 patients confirmed with endobronchial tuberculosis who visited the Department of Pulmonary Medicine at Hangyang University Hospital from January 1990 10 April 1996. The following results were obtained. Results: 1) Total 201 parients(l9.5%) were confirmed as endobronchial tuberculosis among 1031 patients who had been undergone flexible bronchofiberscopic examination. The number of male patients were 55 and that of female patients were 146. and the male to female ratio was 1 : 2.7. 2) The age distribution were as follows: there were 61(30.3%) cases in the third decade, 40 cases(19.9%) in the fourth decade, 27 cases(13.4%) in the sixth decade, 21 cases(10.4%) in the fifth decade, 19 cases(9.5%) in the age group between 15 and 19 years, 19 cases(9.5%) in the seventh decade, and 14 cases(7.0%) over 70 years, in decreasing order. 3) The most common symptom, in 192 cases, was cough 74.5%, followed by sputum 55.2%, dyspnea 28.6%, chest discomfort 19.8%, fever 17.2%, hemoptysis 11.5%, in decreasing order, and localized wheezing was heard in 15.6%. 4) In chest X-ray of 189 cases, consolidation was the most frequent finding in 67.7%, followed by collapse 43.9%. cavitary lesion 11.6%, pleural effusion 7.4%, in decreasing order, and there was no abnormal findings in 3.2%. 5) In the 76 pulmanary function tests, a normal pattern was found in 44.7%, restrictive pattern in 39.5 %, obstructive pattern in 11.8%, and combined pattern in 3.9%. 6) Among total 201 patients, bronchoscopy showed caseous pseudomembrane in 70 cases(34.8%), mucosal erythema and edema in 54 cases(26.9%), hyperplastic lesion in 52 cases(25.9%), fibrous s.enosis in 22 cases(10.9%), and erosion or ulcer in 3 cases(1.5%). 7) In total 201 cases, bronchial washing AFB stain was positive in 103 cases(51.2%), bronchial washing culture for tuberculous bacilli in 55 cases(27.4%). In the 99 bronchoscopic biopsies, AFB slain positive in 36.4%. granuloma without AFB stain positive in 13.1%, chronic inflammation only in 36.4%. and non diagnostic biopsy finding in 14.1%. Conclusions : Young female patients, whose cough resistant to genenal antitussive agents, should be evaluated for endobronchial tuberculosis, even with clear chest roentgenogram and negative sputum AFB stain. Furthermore, we would like to emphasize that the bronchoscopic approach is a substantially useful means of making a differential diagnosis of atelectasis in older patients of cancer age. At this time we have to make a standard endoscopic classification of endobronchial tuberculosis, and well designed prospective studies are required to elucidate the effect of combination therapy using antituberculous chemotherapy with steroids on bronchial stenosis in patients with endobronchial tuberculosis.

  • PDF