Determination of Optimal Section for Corrugated Steel Plates (파형강판의 최적단면 결정)

  • Na, Ho-Sung;Choi, Dong-Ho;Yoo, Hoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.3
    • /
    • pp.5-12
    • /
    • 2011
  • In this paper, after studying structural performance for the representative corrugated steel plate used in Korea, we proposed the optimum shape for section of corrugated steel plate considering a width of steel plates that can be produced currently in the factory. Using AISI(1986) in examination for the performance of the corrugated steel plate, we determined the mechanical limit of the optimum sections considering shear force and bending moment of corrugated steel plate and also determined the geometric limit of them considering formability, shapes and ratio between width of steel plate before forming and that after forming. As a result of examination for performance of steel plate applying algorithm for searching optimal sections algorithm developed in this study to the existing representative corrugated steel plate, allowable force and moment of inertia indicated the maximum values at bending radius 76mm and internal bending angle $50^{\circ}$. And as an application result of the optimum design system that used SS490 with 1,550mm of width and 4,700mm of length considering current production situation in Korea, we developed the new section with more than 2 times of structural performance comparing with existing corrugated steel plate.

Behavior of Circular Hollow Section R.C Member with Internal Corrugated Steel Tube (파형강관을 삽입한 중공원형단면 철근콘크리트 부재의 거동에 관한 연구)

  • Im, Jung-Soon;Kim, Sung-Chil;Jo, Jae-Byung;Lee, Soo-Keun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.1 s.8
    • /
    • pp.123-131
    • /
    • 2003
  • An experiment was carried out to investigate the mechanical behaviour of the circular hollow section reinforced concrete member with internal corrugated steel tube. A specimen, 50cm in diameter and 340cm in length, was made and tested by 3 points bending. The test load was increased slowly (quasi static) to the failure or unacceptable deformation. During the test, lateral displacement at mid point and longitudinal displacement of extreme fiber on compressive and tensile side of the specimen were measured. The measured data were analysed and compared with calculated results for the equivalent member without inserted corrugated steel tube. The comparison shows that the flexural strength and ductility of hollow section reinforced concrete members can be improved by inserting corrugated steel tubes inside.

An Experimental And Theoretical Study on the Corrugated Water-Trickle Collector (파형단면을 가진 유하식 집열기의 이론 및 실험 연구)

  • Lee, Jong-Ho;Chung, Mo;Park, Won-Hoon
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.42-52
    • /
    • 1987
  • 파형 단면을 가진 유하식 집열기의 이론 및 실험 결과로서 유량, 각도등 집열성능에 미치는 영향등이 고려되었다. 입구 온도와 출구온도 차이가 적을 경우에는 이론과 실험치가 잘 맞으나 온도차이가 많을 경우 혹은 입구온도가 높을 때에는 투과체안에 생기는 결로 및 수증기의 영향으로 편차가 커진다. 개방회로와 폐쇄회로의 경우를 구분하여 실험되었는데 개방회로의 경우 효율은 약간 저하되지만 전반적인 성능은 폐쇄회로와 같은 경향을 나타내었다. 개방회로는 과열을 막는 방편으로 이용될 수 있다.

  • PDF

Evaluation of Lateral-Torsional Buckling Strength of I-Girder with Corrugated Web under Uniform Bending (균일한 휨모멘트가 작용하는 파형강판 복부판 I-거더의 횡-비틂 좌굴강도 평가)

  • Moon, Ji Ho;Yi, Jong Won;Choi, Byung Ho;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.463-472
    • /
    • 2007
  • This paper presents theoretical and finite element analysis results for the lateral-torsional buckling of I-girders with corrugated web under uniform bending. Lateral-torsional buckling is a major design aspect for flexural members composed of thin-walled I-section. However, torsional rigidities such as the warping constants of the I-girders with corrugated web are not fully understood yet. In this paper, bending and pure torsional rigidities of I-girders with corrugated web are first described using the results of previous researchers. Then, the location of the shear center and the warping constants are derived. Using the derived section properties of I-girders with corrugated web, the lateral-torsional buckling strength is determined. Finite element analyses are conducted and the proposed lateral-torsional buckling strength of I-girders with corrugated web is successfully verified. Finally, the effects of corrugation profiles of the web on the lateral-torsional buckling load of I-girders with corrugated web are discussed.

Flexural Characteristics of Model Composite Deck Fabricated with VARTM (진공성형 제작 모델 복합소재 바닥판의 실험적 휨 거동특성 분석)

  • Lee Sung-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.4 s.70
    • /
    • pp.417-426
    • /
    • 2005
  • Recent days composite bridge dock is gaining attraction due to many advantages such as light weight, high strength, corrosion resistance, and high durability. In this study, composite deck models of hat, box and triangular section type wore fabricated with VARTM Process. For these models, three point flexural tests wore carried out both in strong and weak axis. The experimental results were compared with each other to determine efficient section profile. It has been demonstrated that composite sandwich deck has strong potentials to be used as bridge deck in the new construction and rehabilitation works.

Static and Free Vibration Analyses of Hybrid Girders by the Equivalent Beam Theory (등가보 이론을 이용한 복합 거더의 정적 및 자유진동 해석)

  • Choi, In-Sik;Ye, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.600-606
    • /
    • 2007
  • 3D finite element analyses of a corrugated steel web girder and a steel truss web girder are conducted to investigate the static and dynamic behaviour of the hybrid girders. And the analyses results are compared with those by the equivalent beam theory. The equivalent theory is a theory that all section properties of a truss structure are replaced by section properties of a beam including a shear coefficient. When applying the equivalent beam theory, the shear coefficient of the corrugated steel web girder is estimated as the area ratio of flange section to web section and that of the steel truss web girder is calculated by the equation proposed by Abdel. Static deflections and natural frequencies by 3D finite element analyses and those by the equivalent beam theory are in good agreement.

Analysis Model of Corrugated Steel Plates for Soil-Metal Box Culverts (지중강판 박스구조물을 위한 파형강판 해석 모델)

  • Choi, Dongho;Lee, Jongsun;Na, Hosung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.5-18
    • /
    • 2010
  • In this paper, a 3-dimensional stiffened plate model for soil-metal box structures is proposed. 3-dimensional stiffened plate model is enable to model corrugated steel plates of soil metal box culverts considering section modulus and section properties of longitudinal and horizontal direction from a corrugated steel plate. Loading conditions which causes maximum displacement and maximum moment according to the step construction stages(a back filling to the top of the plate, a back filling to the maximum depth of cover, and loading of live loads) was applied and the behaviors of the soil metal box culverts was analyzed. Analysis results of 3-dimensional stiffened model were compared with those of 2-dimensional model, 3-dimensional equivalent plate model and 3-dimensional corrugated plate model. As results, the behaviors of 2-dimensional model and 3 dimensional equivalent model are different from 3-dimensional corrugated plate model but the result of 3-dimensional stiffened model has good agreement with that of 3-dimensional corrugated plate model.

The Behavior of Corrugated Steel Pipes on Underground Structures According to the Depth of Cover (파형 강관 지중구조물의 토피고에 따른 거동특성)

  • Yook, Jeong-Hoon;Kim, Nag-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.1
    • /
    • pp.65-73
    • /
    • 2004
  • The analysis of corrugated steel pipes is depending on a second dimension frame analysis or compressed ring model. This is the analysis not to consider the behavior of soil-structure interaction. The behavior of load resistance system is varied according to the depth of cover and the spacing of corrugated steel pipes structure. Therefore, the behavior characteristic of corrugated steel pipes was confirmed through finite element analysis to consider the activity of soil-structure interaction. If soil cover is filled up to the more of optimal depth, behavior of corrugated steel pipes are similar to those of ductile steel pipes according to the earth pressure distribution and effects of traffic loads are decreased. But, If soil cover is filled up to the less of optimal depth, corrugated steel pipes can't behave completely as ductile steel pipes because the passive earth pressure acting on side of corrugated steel pipes is decreased according to the decrement of vertical earth pressure, and the traffic loads influence on the section forces is increased, so that the traffic loads dominated the behavior of corrugated steel pipes.

  • PDF

Approximate Analysis of Corrugated Steel Culverts (파형강판 암거의 근사해석)

  • Choi, Dong-Ho;Kim, Won-Cheul;Kim, Gi-Nam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.4
    • /
    • pp.15-27
    • /
    • 2001
  • This paper proposes the force equations(thrust, moment) of corrugated steel culverts through the finite element method. The conditions for maximum thrust and maximum moment are determined from the analysis of soil-structure interaction during the three construction stages, such as backfill to the crown, backfill to the soil cover, and live loads. The proposed form of thrust and moment equations are deduced from the analysis of behaviour and the application of Castigliano's second theorem for the semi-arch structure. Finally, the coefficients used in the proposed equations are determined from a large number of analysis for the various geometries and the soil-structure relative stiffness under the conditions of maximum thrust and maximum moment.

  • PDF

Torsional and Warping Constants of I-shaped Plate Girders with a Sine Corrugated Web (Sine 파형 복부판을 갖는 I형 플레이트 거더의 비틂 및 뒴 상수)

  • Kim, Seungjun;Jeon, Jin Su;Won, Deok Hee;Kang, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.347-354
    • /
    • 2012
  • In this study, the equations of torsional and warping constants of a I-shaped plate girder with sine corrugated web are suggested. Because of geometric characteristics of the section, a I-shaped plate girder with corrugated web shows high out-of-plane stiffness, shear strength, and torsional stiffness. Torsional constant and warping constant definitely affect lateral-torsional buckling loads. Therefore, exact estimation of the sectional properties is quite important. But, it is difficult to estimate these properties by former methods. So, this study was focused on suggestion of the rational equations to calculate torsional and warping constants. In order to investigate the effects of geometric characteristics of sine-corrugated webs on torsional stiffness and warping torsional constant, finite element analyses for pure torsional behavior and warping torsional behavior of I-shaped plate girders were performed. By regression analyses of the analytical results, rational equations of the torsional constant and warping constant were suggested. Suggested equations for the properties were validated based on the analytical results of lateral-torsional buckling of simply supported I-shaped plate girder. By suggested equations, torsional and warping constants of I-shaped plate girders with a sine-corrugated web can be rationally estimated and more exact lateral-torsional buckling load can be simply calculated.