• Title/Summary/Keyword: 파이프압력

Search Result 129, Processing Time 0.024 seconds

Effects of the Mass of Working Fluid on the Thermal Performance of Heat Pipe with Axial Grooves (그루브형 히트파이프에서 작동유체량이 히트파이프 성능에 미치는 영향)

  • Suh, Jeong-Se;Park, Young-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • An analytical and experimental study of the thermal performance of axial heat pipe with axial groove is conducted to determine the optimal mass of working fluid for the maximum heat transport capacity of heat pipe with axial grooves. Generally, the mass of working fluid has been fully charged by considering only a geometrical shape of axial grooves embedded in a heat pipe. When the heat pipe is operated in a steady state, the meniscus re-cession phenomena of working fluid is occurred in the evaporator region. In this work, the optimal mass of working fluid was obtained from the axial variation of capillary pressure, the radius of curvature and wetting angle of meniscus of liquid-vapor interface. Experimental results were also obtained by varying the mass of working fluid within a heat pipe, and presented for the maximum heat transport capacity corresponding to the operating temperature and the elevation of heat pipe. Finally, the analytical results of the optimal mass of working fluid were compared with those of the experimental mass of working fluid.

Investigation of Pressure Drop for a Pseudo-plastic Fluid Flow in Isosceles Triangle Pipes (이등변삼각형 단면을 갖는 파이프 내의 Pseudo-Plastic 유체유동에 대한 압력강하의 연구)

  • Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.30-35
    • /
    • 2009
  • Numerical Calculations for dimensionless pressure drop (friction factor times Reynolds number) have been obtained for fully developed laminar flow of MPL(Modified Power Law) fluid in isosceles triangle pipes. The solutions are valid for Pseudoplastic fluids over a wide range from Newtonian behavior at low shear rates through transition region to power law behavior at higher shear rates. The analysis identified a dimensionless shear rate parameter which for a given set of operating conditions specifies where in the shear rate range a particular system is operating, i.e., Newtonian, transition or power law region. The numerical calculation data of the dimensionless pressure drop for the Newtonian and power law regions are compared with previously published asymptotic results presenting within 0.16 % in Newtonian region and 2.98 % in power law region.

  • PDF

Analysis on Pressure and Temperature wave of Self Oscillating Heat Pipe (자려 진동 히트파이프의 압력 및 온도 파형 해석)

  • Choi, J.H.;Yoon, D.H.;Oh, C.;Kim, M.H.;Yoon, S.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.43-49
    • /
    • 2000
  • Heat transfer characteristics of self oscillating heat pipe were experimentally investigated for the effect of fill charge ratios and heat loads. The heat pipe used for this study is made of copper capillary, has 0.002m internal diameter, a 0.34m length in one turn and consists of 19 turns. Heating and cooling section each have a length of 70mm. Water was used as working fluid inside heat pipe. As the experimental results, the self oscillating heat pipe was operated by self-exited oscillation and circulation of working fluid and the oscillation within the self oscillating heat pipe assumed chaotic behavior.

  • PDF

Real-time monitoring system for management of chemically management of chemically contaminated water pipeline (유해화학물질 이송관로 파손누수 실시간 감시 기술)

  • Kim, Joon-Seok;Yoon, Byoung-Jo;Seo, Jae-Soon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.195-196
    • /
    • 2015
  • 유해화학물질 이송관로의 실시간 유지관리를 위하여 파손사전 예방감시를 위한 이중구조 파이프 제작, GIS관망 구축을 위한 측량 및 시공 속성정보 수집을 위한 스마트 폰 앱 프로그램 개발, 실시간 감시를 위한 서버프로그램 개발을 수행하였다. 또한, 파일럿규모의 야외시험시설을 구축하여 시스템 동작여부를 확인하였다. 파손 예방은 파이프에 부착된 센서 케이블을 통하여 감지하도록 하였고, 누수는 압력센서를 일정한 간격으로 설치하여 시험하였다. VRS 측량장비와 스마트폰을 연계할 수 있는 앱 프로그램으로 실시간 자료 수집을 수행할 수 있도록 하였고, 감시 서버프로그램을 통하여 실시간 감시 및 알람이 가능하도록 하였다.

  • PDF

A Study on the Development of a Novel Pressure Sensor based on Nano Carbon Piezoresistive Composite by Using 3D Printing (3D 프린팅을 활용한 탄소 나노 튜브 전왜성 복합소재 기반 압력 센서 개발 연구)

  • Kim, Sung Yong;Kang, Inpil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.187-192
    • /
    • 2017
  • This paper presents an ongoing study to develop a novel pressure sensor by means of a Nano Carbon Piezoresistive Composite (NCPC). The sensor was fabricated using the 3D printing process. We designed a miniaturized cantilever-type sensor electrode to improve the pressure sensing performance and utilized a 3D printer to build a small-sized body. The sensor electrode was made of 2 wt% MWCNT/epoxy piezoresistive nano-composite, and the sensor body was encapsulated with a pipe plug cap for easy installation to any pressure system. The piezoresistivity responses of the sensor were converted into stable voltage outputs by using a signal processing system, which is similar to a conventional foil strain gauge. We evaluated the pressure-sensing performances using a pressure calibrator in the lab environment. The 3D-printed cantilever electrode pressure sensor showed linear voltage outputs of up to 16,500 KPa, which is a 200% improvement in the pressure sensing range when compared with the bulk-type electrode used in our previous work.

A Theoretical Analysis on Pressure Loss and Gas Volumetric Fraction of Gas-Liquid Two-Phase Flow (기액이상류의 압력손실과 가스상의 체적분율에 관한 이론적 해석)

  • Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Gas volumetric fractions and pressure loss are very important parameters in understanding and predicting gas-liquid two-phase flows. They are also essential to design large heat exchanging system in many industries, boiler and refrigerating systems mounted at ships. This paper therefore presents a theoretical method of predicting the pressure loss and gas volumetric fractions in gas-liquid two-phase flows for the whole range of pipe inclinations. The theoretical analysis is based on the two-fluid stratified flow model. It also provides the results of the comparisons between this theoretical analysis results and previous experimental results.

  • PDF

Study on the Performance Improvement of the Aftermarket Automotive Muffler (비순정품 자동차 머플러의 성능개선)

  • Lee, Sung-Won;Choi, Doo-Seuk;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2602-2608
    • /
    • 2009
  • Aftermarket muffler has been developed mainly by personal experience and trial-and error and has not been properly simulated or evaluated its performance. One of the aftermarket muffler problems is that the aftermarket muffler has quite high pressure-drop across the passage. To reduce the pressure-drop, various simulation and test has been performed for various muffler models. As a result, the muffler that has superior pressure-drop and vibration characteristics compared to the previous muffler has been developed. Developed aftermarket muffler has a structure that avoids confined space causing vibration due to exhaust pressure pulsation and bisects an inlet pipe from the engine.

Theoretical Analysis on the Heat Transport Limitation of a Sintered Metal Wick Heat Pipe (소결윅 히트파이프의 열수송 한계에 관한 이론적 해석)

  • Kim Keun-Bae;Kim Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.4
    • /
    • pp.16-25
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitation of a copper powder sintered wick heat pipe was performed. The heat pipe diameter was 8mm and water was used for working fluid. The particle diameter was classified by 5 different meshes, and each capillary pressures and heat transport limitations. thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius($r_c$), porosity($\varepsilon$), Permeability (K). The wick capillary limitation was increased according as the particle diameter and the wick thickness and the operating temperature were increased. As the porosity and the capillary radius were larger. then the heat transport limitation was higher. The thermal resistance was greatly increased according as the wick thickness was increased.

A Study on the Impact of CO2 Immersion Test for Rubber Sealing Materials (고무 씰링 재료에 대한 CO2 침지 영향에 관한 고찰)

  • Seo, Doo-Hyoun;Jang, Kap-Man;Lee, Jin-Han;Rhie, Kwang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.26-32
    • /
    • 2014
  • CCS(Carbon Capture and Storage) which is technic to capture and storage the carbon-dioxide is the method that reduces the carbon-dioxide from the industries to prevent earth from the global warming. In order to apply to the practical site, it is inevitable to investigate the possibility of damage in the pipe or components by carbon-dioxide. In this paper, the immersion test is performed to estimate the suitability of the rubber which is used to seal or connect the pipelines because the rubber has not been validated. Also, the immersion test is carried out in a certain condition(pre- and supercritical state).

경상분지 남동부 일광광산에 산출하는 전기석 기원과 그 중요성에 관한 예비연구

  • 장주연;양경희;이준동
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2001.06a
    • /
    • pp.58-59
    • /
    • 2001
  • 부산에서 북동쪽으로 대략 25km 떨어진 지점에 위치하고 있는 일광광산 부근의 지질은 백악기 화산암ㆍ퇴적암 그리고 이를 관입한 화강암류와 이 암주 내에 발달하는 구리-중석을 함유하고 있는 각력파이프광상으로 이루어져 있다. 일광광산의 화강암류는 거의 타원형으로 felsic한 중앙부와 mafic한 양상의 주변부로 나뉘어지며, 암주 내에 수직적인 원통형의 각력파이프가 광화대를 이루고 있고, 그 주변에는 모암변질대가 발달되어 있다. 각력파이프를 충진하고 있는 vein과 화강암의 중앙부에는 전기석이 풍부하게 산출되고 있다. 일광광산에서 산출되는 전기석은 야외 관찰시 각력파이프 중심에서부터 외곽부쪽으로 전기석의 풍부함이 감소하며 산출형태도 달라진다. 파이프에서 대략반경 150m내에서 전기석은 침상형 의 방사상 모양 내지 rosettes형으로 풍부하게 산출되며, 화강암내의 mafic한 암편을 치환한 형태로 산출되기도 한다. 암주의 중앙부 주변부에서는 거의 미세한 구상형으로 산재되어 나타나고 있다. 전기석은 복잡한 화학식 {(Na, Ca)(Fe, Mg)$_3$(Al, Li)$_{6}$(BO$_3$)$_3$Si$_{6}$O$_{18}$ (OH, F)$_4$}을 갖는 붕산 규산염광물이다. 이러 한 다양한 성분은 마그마의 진화과정, 모암의 특성, 온도, 압력, 성분과 같은 물리ㆍ화학적 성질에 따라 전기석의 성분이 체계적으로 변하기 때문에 모암과 전기석 기원과의 상관관계를 파악할 수 있다. 파이프 부근의 화강암류는 현미 경상에서 전기석이 석류석과 같이 풍부하게 나타나며 장석들은 변질받은 상태로 세리사이트, 녹렴석으로 나타나고, 흑운모와 각섬석은 녹니석화되어 변질된 상태를 보이고 있다. 파이프 중심에서 외곽부로 갈수록 전기석의 함량은 줄어들고 있고 장석들이 알바이트ㆍ칼스베드 쌍정을 보이며, 흑운모가 각섬석보다는 우세하게 나타나고 있다. 전기석은 주상 결정, 자형 내지 반자형의 입자로 다색성을 보이며, 결정 중심에서 가장자리로 갈수록 파란색과 황갈색의 광학적 누대구조를 관찰할 수 있다. 일광광산에서 산출되는 전기석에 대한 현미경 관찰은 열수기원임을 지시하고 있다. 야외조사와 현미경 관찰의 예비조사에 의하면 일광광산의 전기석이 형성된 환경은 다른2가지 화학적인 저장소의 혼합 효과의 결과로 생성되어진 것으로 예상된다. 일광의 화강암류를 만든 마그마는 전기석을 형성할 만큼의 Fe-Mg성분이 충분하지 않았을 것이다. 화강암 내에 흑운모와 각섬석의 결정작용에 의해 마그마의 Fe-Mg성분이 고갈되어지고 이로 인해 그 함량이 감소하며 상대적으로 마그마 내에 남은 붕소(B$_2$O$_3$)는 열수로 용리되고 흑운모, 각섬석과 평형을 유지하며 열수에 남아있게 된다. 잔류용융체에 남은 붕소의 함량은 전기석을 만들기에 충분함에도 불구하고, Fe-Mg 함량이 부족하여 마그마 기원의 전기석 결정을 만들 수가 없다가 광맥이 형성된 시기에 또 다른 열수가 공급되면서 이전의 평형이 깨지고 기존의 흑운모와 같은 염기성 광물이 붕소(B)를 함유한 새로운 열수와 반응하여 전기석을 형성한 것으로 예상한다. 앞으로 전암과 광물에 대해 지화학적 연구를 통해 화강암류와 전기석과의 지화학적 연관성, 주성분 원소와 열수의 특성과의 상관관계, 전기석의 기원(마그마 기원인지 열수기원인지)이 보다 정확하게 파악될 것이다. 마그마 진화에 따른 전기석의 성분변화와 기원을 이용하여 일광광산의 동광화대를 형성한 마그마 계에서 열수계로 이어지는 지질학적 과정을 이해할 수 있을 것이며, 암석 성인론적 지시자로서 어떠한 중요성을 갖는지 논의되어질 수 있다.

  • PDF