• Title/Summary/Keyword: 파라미터 불안정

Search Result 73, Processing Time 0.037 seconds

Intelligent Fuzzy Modeling and Robust Digital fuzzy Control for Level Control in the Steam Generator of a Nuclear Power Plant (원전 증기발생기의 수위제어를 위한 지능형 퍼지 모델링 및 강인한 디지털 퍼지 제어기 설계)

  • Joo, Young-Hoon;Cho, Kwang-Lae;Kim, Joo-Won;Park, Jin-Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.4
    • /
    • pp.311-316
    • /
    • 2002
  • Difficulties of the level control in the steam generator are increased due to their nonlinear characteristics. Futhermore, parameter uncertainties of the steam generator is related with control performance and stability. The efficiency of digital conversion in control systems is proved in many recent researches. In order to solve this problem, this paper suggests robust digital fuzzy controller design methodologies of the steam generator which have unstable parameters. Takagi-Sugeno (TS) fuzzy model is used to construct a fuzzy model which has uncertainties in the steam generator. In designing procedure, intelligent digital redesign method is used to control the nonlinear system. This digital controller keeps the performance of the analog controller. Simulation examples are included for ensuring the proposed control method.

Unknown-Parameter Identification for Accurate Control of 2-Link Manipulator using Dual Extended Kalman Filter (2링크 매니퓰레이터 제어를 위한 듀얼 확장 칼만 필터 기반의 미지 변수 추정 기법)

  • Seung, Ji Hoon;Park, Jung Kil;Yoo, Sung Goo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.53-60
    • /
    • 2018
  • In this paper, we described the unknown parameter identification using Dual Extended Kalman Filter for precise control of 2-link manipulator. 2-link manipulator has highly non-linear characteristic with changed parameter thought tasks. The parameter kinds of mass and inertia of system is important to handle with the manipulator robustly. To solve the control problem by estimating the state and unknown parameters of the system through the proposed method. In order to verify the performance of proposed method, we simulate the implementation using Matlab and compare with results of RLS algorithm. At the results, proposed method has a better performance than those of RLS and verify the estimation performance in the parameter estimation.

Performance Evaluation of Machine Learning Optimizers (기계학습 옵티마이저 성능 평가)

  • Joo, Gihun;Park, Chihyun;Im, Hyeonseung
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.766-776
    • /
    • 2020
  • Recently, as interest in machine learning (ML) has increased and research using ML has become active, it is becoming more important to find an optimal hyperparameter combination for various ML models. In this paper, among various hyperparameters, we focused on ML optimizers, and measured and compared the performance of major optimizers using various datasets. In particular, we compared the performance of nine optimizers ranging from SGD, which is the most basic, to Momentum, NAG, AdaGrad, RMSProp, AdaDelta, Adam, AdaMax, and Nadam, using the MNIST, CIFAR-10, IRIS, TITANIC, and Boston Housing Price datasets. Experimental results showed that when Adam or Nadam was used, the loss of various ML models decreased most rapidly and their F1 score was also increased. Meanwhile, AdaMax showed a lot of instability during training and AdaDelta showed slower convergence speed and lower performance than other optimizers.

Predictive Current Control of a Grid-Connected Inverter with Grid Voltage Observer (계통전압 관측기를 이용한 계통연계형 인버터의 예측전류제어)

  • Lee, Kui-Jun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.159-166
    • /
    • 2010
  • For a grid-connected inverter in distributed generation systems, the current control is essential, and recently, the predictive current control based on a high performance digital signal processors (DSP) to satisfy a fast dynamic response has been widely investigated. However, the performance of predictive current control is degraded by the time delay due to digital implementation, the parameter and measured value errors and the interference of noise, and also theses make system even unstable. Therefore, this paper proposes the predictive current control using grid voltage observer for grid-connected inverter applications. To determine the relevant voltage observer gain, the low-order harmonics of grid voltage are considered, and the effect of filter parameter errors is analyzed. The proposed method has a fast current response capability, the robustness to noise and simple implementation due to voltage sensorless control and the robust current control performance to low-order grid harmonics. The feasibility of the proposed method is verified by simulation and experimental results.

Neuro PID Control for Ultra-Compact Binary Power Generation Plant (초소형 바이너리 발전 플랜트를 위한 Neuro PID 제어)

  • Han, Kun-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1495-1504
    • /
    • 2021
  • An ultra-compact binary power generation plant converts thermal energy into electric power using temperature difference between heat source and cooling source. In the actual power generation environment, the characteristic value of the plant changes due to any negative effects such as environmental condition or corrosion of related equipment. If the characteristic value of the plant changes, it may lead to unstable output of the turbine in a conventional PID control system with fixed PID parameters. A Neuro PID control system based on Neural Network adaptively to adjust the PID parameters according to the change in the characteristic value of the plant is proposed in this paper. Discrete-time transfer function models to represent the dynamic characteristics near the operating point of the investigated plant are deduced, and a design strategy of the proposed control system is described. The proposed Neuro PID control system is compared with the conventional PID control system, and its effectiveness is demonstrated through the simulation results.

Numerical Analysis of Nonlinear Longitudinal Combustion Instability in LRE Using Pressure-Sensitive Time-Lag Hypothesis (시간지연 모델을 이용한 액체로켓엔진의 축방향 비선형 연소불안정 해석)

  • Kim Seong-Ku;Choi Hwan Seok;Park Tae Seon;Kim Yong-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.281-287
    • /
    • 2005
  • Nonlinear behaviors such as steep-fronted wave motions and a finite amplitude limit cycle often accompanying combustion instabilities have been numerically investigated using a characteristic-based approximate Riemann solver and the well-known ${\eta}-{\tau}$ model. A resonant pipe initially subjected to a harmonic pressure disturbance described the natural steepening process that leads to a shocked N-wave. For a linearly unstable regime, pressure oscillations reach a limit cycle which is independent of the characteristics of the initial disturbances and depends only on combustion parameters and operating conditions. For the 1.5 MW gas generator under development in KARI, the numerical results show good agreement with experimental data from hot-firing tests.

  • PDF

Comparison of Acoustic Parameters According to the Section of Analysis in Sustained Vowel Phonation (모음연장 음성 샘플의 분석 구간에 따른 음향학적 파라미터 비교)

  • Shin, Yu-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.269-274
    • /
    • 2017
  • This study aimed to investigate the acoustic differences that occur in diverse sections of sustained vowel phonation, which is often used in an objective speech analysis of voice disorder patients. The subjects included 17 voice disorder patients (vocal nodules) and 12 normal individuals without any voice disorder. The participants' sustained vowel phonation of /a/ was divided into onset, middle, and offset, and the jitter, shimmer, and NHR in each section were analyzed using the MDVP(Multi-Dimensional Voice Program). The Friedman test and post hoc analysis were used. In the vocal nodules group, the jitter, shimmer and NHR were significantly higher in the off section of sustained vowel phonation than in the middle section, and there were no significant differences between the beginning and middle sections. In contrast, in the group of normal individuals, there were no significant differences between any of the sections. The values of the acoustic parameters according to the section of analysis in the sustained vowel phonation are different and the vocal in the end section is significantly more unstable than that in the middle section. The results of this study will be useful for selecting the sections to be analyzed in sustained vowel phonation and interpreting the results of the analysis.

Design of Levitation Controller with Optimal Fuzzy PID Controller for Magnetic Levitation System (최적 퍼지PID제어기를 이용한 자기부상시스템의 부상제어기 설계)

  • Cho, Jae-Hoon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.3
    • /
    • pp.279-284
    • /
    • 2014
  • This paper proposes a optimum design method for the Fuzzy PID controller of magnetic levitation-based Rail-Guided Vehicle(RGV). Since an attraction type levitation system is intrinsically unstable, it is difficult to completely satisfy the desired performance through the methods designed by conventional controllers. In the paper, the Fuzzy PID controller with fixed parameters are applied and then the optimum parameters of fuzzy PID controller are selected by genetic algorithm. For the fitness function of genetic algorithm, the performance index of PID controller is used. To verify the performance of the proposed method, we used Matlab/simulink model of Maglev and compared the proposed method with the performance of PID controller. The simulation results show that the proposed method is more effective than conventional PID controller.

ATTITUDE STABILITY OF A SPACECRAFT WITH SLOSH MASS SUBJECT TO PARAMETRIC EXCITATION (계수자극을 받는 유동체를 포함한 위성체의 자세 안정도 해석)

  • Kang, Ja-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.3
    • /
    • pp.205-216
    • /
    • 2003
  • The attitude motion of a spin-stabilized, upper-stage spacecraft is investigated based on a two-body model, consisting of a symmetric body, representing the spacecraft, and a spherical pendulum, representing the liquid slag pool entrapped in the aft section of the rocket motor. Exact time-varying nonlinear equations are derived and used to eliminate the drawbacks of conventional linear models. To study the stability of the spacecraft's attitude motion, both the spacecraft and pendulum are assumed to be in states of steady spin about the symmetry axis of the spacecraft and the coupled time-varying nonlinear equation of the pendulum is simplified. A quasi-stationary solution to that equation and approximate resonance conditions are determined in terms of the system parameters. The analysis shows that the pendulum is subject to a combination of parametric and external-type excitation by the main body and that energy from the excited pendulum is fed into the main body to develop the coning instability. In this paper, numerical examples are presented to explain the mechanism of the coning angle growth and how angular momenta and disturbance moments are generated.

Availability Analysis of Cluster Web Server System using Software Rejuvenation Method (소프트웨어 재활 기법을 사용한 클러스터 웹서버 시스템의 가용도 분석)

  • 강창훈
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.1
    • /
    • pp.77-84
    • /
    • 2002
  • An cluster system used consist of large number of running servers, one has the problem that does the low availability occured by the high chance of the server failures and it is difficult to provide occuring software aging. In this paper, running cluster web servers consists of n primary servers and k backup servers, based on the operational parameters such as number of running primary servers, number of backup severs, rejuvenation period, rejuvenation time, failure rate of sewers, repair rate of servers, unstable rate of servers. We calculate to evaluate the rejuvenation policy such steady-state probabilities, downtime, availability, and downtime cost. We validate the solutions of mathematical model by experiments based on various operation parameters and find that the software rejuvenation method can be adopted as prventive fault tolerant technique for stability of system. The failure rate and unstable rate of the servers are essential factors for decision making of the rejuvenation policies.

  • PDF