• Title/Summary/Keyword: 파괴 깊이

Search Result 294, Processing Time 0.029 seconds

A numerical study on the 3-Dimensional shape characteristics of small underground cavities (소규모 지하공동 3차원 형상 특성을 반영한 수치해석에 관한 연구)

  • An, Joon-Sang;Kang, Kyung-Nam;Son, Ki-Il;Kim, Woo-Seok;Kim, Byung-Chan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.787-807
    • /
    • 2018
  • When conducting the underground safety impact assessment under the special law in Korea, it is essential to investigate the occurrence of underground cavities. When underground cavities were discovered, the underground safety was assessed through numerical analysis. The previous study has suggested the stability evaluation based on the factor of safety by changing the 2D shape of the small underground cavity. In this study, the effects of small underground cavities considering 3D shapes were examined using a continuum analysis program and compared with the 2D results presented in previous study. If the 3-Dimensional shape of the underground cavity is found close to the sphere type, it would be reasonable to evaluate the factor of safety by the shear strength reduction method regardless of the size and position of the cavity. If a high-aspect ratio underground cavity with a depth of 2 m or more from the ground surface and an aspect ratio (a/b) of 2.0 or more is in the vertical direction, not only the factor of safety but the failure mode shape should be cautions in the stability evaluation using the shear strength reduction method. The results of this study are expected to be basic data on underground safety impact assessment.

Experimental Study on the Characteristics of Local Scour Hole Downstream of V-shaped Drop Structure Model (V자형 낙차공 모형 직하류 국부세굴공 발생특성에 관한 실험적 연구)

  • Eom, Junghyun;Han, Hyeongjun;Park, Sung Won;Ahn, Jungkyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.8-14
    • /
    • 2019
  • A drop structure, one of the representative river-crossing structures, is constructed to stabilize a riverbed. On the other hand, the structure interrupts the continuity of the river and causes the destruction of the hydro-ecological environment. Therefore, laboratory experiments of a natural type of drop structure with low differences were performed, and the empirical formula of a local scour hole is proposed. Four experimental flow rates were tested for various types of the drop structure models with 28 test cases. Based on the scour test, it was confirmed that the maximum scour depth occurs rather than the result of applying the previously proposed scour depth formulae. Correlation analysis of the major factors of scour hole at the downstream of the drop structure revealed a strong correlation between the upstream flow characteristics, drop structure height, and total crossing length of the drop model. In addition, the depth and length estimation formula of the maximum scour hole were proposed using the dimensionless variables and validated. In the future, it is also expected that more accurate scour prediction and calculation can be derived by conducting experimental studies and numerical analysis considering the various bed materials and flow conditions.

Evaluation of the Stress Corrosion Cracking Behavior of Inconel G00 Alloy by Acoustic Emission (음향 방출에 의한 인코넬 600 합금의 응력 부식 균열 거동 평가)

  • Sung, Key-Yong;Kim, In-Sup;Yoon, Young-Ku
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.174-183
    • /
    • 1996
  • Acoustic emission(AE) response during stress corrosion cracking(SCC) of Inconel 600 alloy has been monitored to study the AE detectability of crack generation and growth by comparing the crack behavior with AE parameters processed, and to evaluate the applicability as a nondestructive evaluation(AE) by measuring the minimum crack size detectable with AE. Variously heat-treated specimens were tensioned by constant extension rate test(CERT) in various extension rate to give rise to the different SCC behavior of specimens. The AE amplitude level generated from intergranular stress-corrosion cracking(IGSCC) is higher than those from ductile fracture and mechanical deformation, which means the AE amplitude can be a significant parameter for distinguishing the An source. AE can also provide the effective means to identify the transition from the small crack initiation and formation of dominant cracks to the dominant crack growth. Minimum crack size detectable with AE is supposed to be approximately 200 to $400{\mu}m$ in length and below $100{\mu}m$ in depth. The test results show that AE technique has a capability for detecting the early stage of IGSCC growth and the potential for practical application as a NDE.

  • PDF

A Study on Shear Capacity and Behavior of Large Sized Concrete Anchorage System (대형 콘크리트 앵커시스템의 전단성능 및 거동특성에 관한 연구)

  • Kim, Kang Sik;Shin, Sung Woo;Lee, Kwang Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.82-91
    • /
    • 2011
  • In this study, 24 prototype specimens were tested to find out the shear behavior and strength of large anchorage system exceeding 50mm(2") in anchor bolt diameter($d_0$) and 635mm(25") in effective embedment depth($h_{ef}$) not addressed by ACI349-06 Appendix B. Test variables are anchor bolt diameter($d_0$ = 63.5, 76.2, 88.9mm), effective embedment depth($h_{ef}$=635, 762mm), and edge distance($c_1$=381, 508, 762mm). Concrete compressive strength is constant($f_{ck}$=38MPa). Test results ($V_{test}$) were overestimated by $V_{aci06}$(shear strength by ACI 349-06) and $V_{ccd}$(shear strength by CCD method). In large anchorage system exceeding 50mm(2") of anchor bolt diameter($d_0$) and 635mm(25") of anchor bolt effective embedment depth($h_{ef}$), the bolt diameter variation and effective embedment depth($h_{ef}$) has no influence on the shear strenth, But, according to the analysis results of the feature ratio on edge distance($c_1$) and anchor bolt diameter, the feature ratio become smaller, which means anchor bolt diameter is bigger, predicted ratio of test results and predicted equation is larger. It was found that anchor bolt diameter is immediate cause of deterioration in the shear capacity of large anchorage system. To improve and extend the validity of current design recommendations further theoretical and numerical work is needed.

A Study on the Characteristics of the Landslide in Hyuseok-dong(I) -Topographical Characteristics and Surface Displacement- (휴석동(休石洞) 땅밀림형(型) 산사태(山沙汰)의 발생특성(發生特性)에 관한 연구(硏究)(I) -지형(地形) 및 지표이동특성(地表移動特性)-)

  • Woo, Bo-Myeong;Park, Jae-Hyeon;Choi, Hyung-Tae;Jeon, Gi-Seong;Kim, Kyung-Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.4
    • /
    • pp.565-570
    • /
    • 1996
  • The landslide survey in an area of about 10 ha was carried out in Hyuseok-dong. Youngchoon-myeon, Danyang-gun, Choongcheongbuk-do. The results showed that there were many indications on geographical changes, such as scars, depressions, upheavals, cracks and destructions of the construction features. The mean degree of slope of the study area was $28^{\circ}$. The results of surface displacement in this area showed that landslide mass is moving in the direction of SE~SEE, and horizontal and vertical movement rate of the center of moving mass was about 1.2m/year and 0.86m/year, respectively. It was estimated that the amount of the soil erosion in the cliff at the lower edge of this area was 0.823m due to the caving erosion by the Namhangang(River) from June through November, 1995.

  • PDF

Fatigue Capacity Evaluation of Hinge Type Connection System for a Hybrid Truss Bridge (복합 트러스교 힌지형 격점 구조의 피로 성능 평가)

  • Jung, Kwang-Hoe;Yi, Jong-Won;Lee, Sang-Hyu;Kim, Jay Jang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.303-310
    • /
    • 2011
  • To replace a steel box bridge for constructions of medium span bridges in Korea, the Hybrid Truss Bridge (HTB) is being considered as an alternative bridge type. The core technology of HTB is the connection joint that links the concrete slabs and steel truss pipes. Various construction companies in Japan have developed unique connection systems and applied to the real bridge constructions after verifying their performances through the experimental evaluation. In this study, the fatigue test of a hybrid truss girder has been performed in order to verify the newly proposed hinge type connection joint`s static and fatigue capacities. Through this fatigue test results, it is founded that the structural detail to improve the fatigue capacity should be developed. The hinge connection system with circular ribs has been proposed by means of structural finite element analyses. And then the fatigue test for this connection joint has been performed and it is proved that this connection joint has enough fatigue capacity. Finally, it is expected that the hinge connection system with circular ribs developed by in this study can be easily applied to the real bridge.

Prediction of a Debris Flow Flooding Caused by Probable Maximum Precipitation (가능 최대강수량에 의한 토석류 범람 예측)

  • Kim, Yeon-Joong;Yoon, Jung-Sung;Kohji, Tanaka;Hur, Dong-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.2
    • /
    • pp.115-126
    • /
    • 2015
  • In recent years, debris flow disaster has occurred in multiple locations between high and low mountainous areas simultaneously with a flooding disaster in urban areas caused by heavy and torrential rainfall due to the changing global climate and environment. As a result, these disasters frequently lead to large-scale destruction of infrastructures or individual properties and cause psychological harm or human death. In order to mitigate these disasters more effectively, it is necessary to investigate what causes the damage with an integrated model of both disasters at once. The objectives of this study are to analyze the mechanism of debris flow for real basin, to determine the PMP and run-off discharge due to the DAD analysis, and to estimate the influence range of debris flow for fan area according to the scenario. To analyse the characteristics of debris flow at the real basin, the parameters such as the deposition pattern, deposit thickness, approaching velocity, occurrence of sediment volume and travel length are estimated from DAD analysis. As a results, the peak time precipitation is estimated by 135 mm/hr as torrential rainfall and maximum total amount of rainfall is estimated by 544 mm as typhoon related rainfall.

Use Impacts of Trail and Campsite on Natural Environments in Mt. Palgong Natural Park (팔공산자연공원에서의 등산로 및 야영장 이용이 자연환경에 미치는 영향)

  • 권태호
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.17 no.3
    • /
    • pp.21-34
    • /
    • 1990
  • Trail and campground deteriorations and their environmental changes of soil and vegetation were studied in Tonghwa -Sa district of Mt. Palgong Natural Park through 1988 into 1989. The results are summarized as follows : 1. The bare width of trail as one of the trail condition factor was significantly greater on the more heavily used trail. Deterioration types of trail which had higher frequency for a total of 45 observations were rock exposure(42%), trail deepening(40%) and root exposure(18%) in the high order. And also sound type on which the trail was not deteriorated at all amounted to 33% of all observations. 2. Ecological changes of soil and vegatation of trailsides were not found at a uniform tendency except that soil hardness was slightly decreased from trail edge to the forest, but they could be grouped by the type of user\`s behavior and site conditions. Use impacts on the natural environment of trailside in Mt. Palgong are still far from the severe harmulness. 3. Worse damages to compground condition were appeared in Bawi-gol than Susu-gol campsite. Types of mechanically damaged trees were tree with exposed root(63% ), scared tree(43% ), mutilated tree(30 % ) and felled tree in highly frequent order. And diameter increments of trees in campsites were oppressed by the campers. 4. Tree damage types and their frequencies could be basic as a means of which grasp the bounds of user's impacts. User's disturbance on campsite extended to the distance of 70∼90m from the core of campsite at Pawi-gol and 20∼30m at Susu-gol respectively. As the tolerant trees to use impact, Lespedeza maximowiczii, Rhus trichocarpa, Acer palmatum, Rubus crataegifolius and Celastrus orbiculatus were considered.

  • PDF

The Changes of Coastal Water Level due to the Development of Mokpo Harbor and Construction of Daebul Industrial Complex (목포항 개발 및 대불 산업단지 조성에 따른 연안해역 해면변화)

  • 정명선;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1991.06a
    • /
    • pp.37-44
    • /
    • 1991
  • 영산강 하구언 방조제의 건설로 인한 항만 및 이의 인접해역 해면의 변화는 예상한 바 있으며 실제 여러개소에서 월 2회정도의 주기로 목포 구항부근 상업지역에서 해면상승에 따라 주기적으로 침수되는 현상이 나타나고 있다 목포항의 영산강 하구언 방조제 조성으로 인한 조류성분중 최고기록을 가진 수로에서는 6kts 정도로 감소된 것으로 보고되고 있으나 주위자연환경 변화에 따른 수면 상승 및 해수면의 주기적인 변화 등에 대한 상세한 언급 및 깊이 있는 분석은 회피되어왔다. 수자원의 효율적관리를 위해 하구언 방조제는 이미 건설되었고 앞으로 대규모의 항만개발과 대불산업단지조성을 위해 추가 3개의 만입해안해역에 댐으로 해역을 막아 매립공사를 추진하고 있다 그러나 이 지역에 대한 분석은 타당성의 여부만을 강조한 상업적 용역이 이루어지고 있고 장래 개발에 대해 학술적이고 실질적인 문제점 추출과 해결방아네 대해서는 무시하거나 경시한 바가 많다 더구나 태풍 저기압 등과 같은 자연재해를 고려한 분석은 시도되지 못하고 있다 따라서 개발전후의 현상에 대한 상세한 자료 및 현장 조사와 극한 상태를 고려하여 개발에 따른 수위상승 부진동, 조류 수질등 이해역의 변화요소를 수집하고 분석하며 과학적 접근방법에 기초를 둔 수치모델의 실험을 포함하여 현장관측 및 측정자료를 검증하는 것이 필수적이라고 사료되어 종합분석의 한단계로 여기서는 하구언 및 하구간척(Land Reclamatic of Estuary barren)으로 해역축소에 따른 해면변화의 실제현상을 조사하여 정리하고 이를 수치모델을 통해 시뮬레이션하여 보았다 이는 종합개발의 좋은 기초자료로 이용됨은 물론이로 이지역의 개발에 기여할 것으로본다.적절하게 가정된 지반의 응력-변형률 관계와 간극수압특성에 의하여 고려되었다. 그 결과 응력 및 변위가 심하게 발생하는 지역은 황색 점토층이었으며 이로부터 황색 점토층에서 부터 파괴면이 생성되어 다른 지역으로 전파되었음을 유추할 수 있었다.form trap with 2.88[eV] deep of injected space charge from the chathode in the crystaline regions. The origin of ${\alpha}$$_2$ peak was regarded as the detrapping process of ions trapped with 0.9[eV] deep originated from impurity-ion remained in the specimen during production process of the material, in the crystalline regions. The origin of ${\beta}$ peak was concluded to be due to the depolarization process of "C=0"dipole with the activation energy of 0.75[eV] in the amorphous regions. The origin of ${\gamma}$ peak was responsible to the process combined with the depolarization of "CH$_3$", chain segment, with the activation energy of ca

  • PDF

Tension Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력저항 앵커의 인장 시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.175-181
    • /
    • 2004
  • This study is about a section where underground water level occurs at the underground 5m depth by the excavation of the ground, as a stream is adjacent to a excavation section of High Speed Railway ${\bigcirc}{\bigcirc}$ Station construction sections and a reservoir being always full of water is located at the left side of the construction section. Therefore this test is executed for the design and construction of buoyance anchors able to permanently prevent buoyance by the underground water level at working and for the stable construction and permanent smooth maintenance of structures. In this test, bar type anchors are divided according to their length and standard to execute test-anchor test, and In spot test, 9 test-anchors test, proof test to construction process, suitability test and acceptance test are executed 4 times to 9 test-anchors by dividing anchors according to the length of permanent anchor, the outer diameter of bar and boring diameter. Standard motion characteristic centering on load transmission and break mechanism of bar-type anchors for the prevention of buoyance will be showed in the thesis.