• Title/Summary/Keyword: 특성엑스선

Search Result 81, Processing Time 0.029 seconds

Analysis of Tissue Equivalent Characteristics of Agar Phantom for Hyperthermia Therapy (온열종양치료 한천 팬텀의 조직등가 특성 분석)

  • Jeong-Geun Park;Kyeong-Hwan Jeong;Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.985-991
    • /
    • 2023
  • A tissue-equivalent phantom is necessary for quality control of hyperthermia therapy. However, since there is no phantom for this purpose, phantoms made from agar are being used in various studies. The tissue-equivalent properties of the agar phantom were confirmed by comparison with the tissue-equivalent material bolus in this study. CT images of the agar phantom and bolus were acquired, and tissue equivalent characteristics were analyzed with image analysis and dose calculation using a computerized radiation therapy planning system. The average pixel value was 96.960±10.999 in bolus, 108.559±8.233 in 3% agar phantom, and 111.844±8.651 in 4% agar phantom. Using the SSD technique, 100 cGy was prescribed at a depth of 1.5 cm and 6 MV X -ray was set to irradiated to 10x10 cm2, and the absorbed dose according to depth was calculated from the central axis of the beam. The intraclass correlation coefficient of dose distribution of bolus, 3% agar phantom, and 4% agar phantom was 0.979 (p<.001, 95%CI .957-.991). The density (g/cm3) at the point where the absorbed dose was calculated was 0.990±0.020 at the bolus, 1.018±0.020 at the 3% agar phantom, and 1.035±0.024 at the 4% agar phantom. In this study, the internal density distribution and uniformity of the agar phantom were confirmed to be appropriate as a tissue equivalent material by analysis of CT images and a computerized radiation therapy planning system.

Surface Coating Treatment of Phosphor Powder Using Atmospheric Pressure Dielectric Barrier Discharge Plasma (대기압 유전체배리어방전 플라즈마를 이용한 형광체 분말 코팅)

  • Jang, Doo Il;Ihm, Tae Heon;Trinh, Quang Hung;Jo, Jin Oh;Mok, Young Sun;Lee, Sang Baek;Ramos, Henry J.
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.455-462
    • /
    • 2014
  • This work investigated the hydrophobic coating of silicate yellow phosphor powder in the form of divalent europium-activated strontium orthosilicate ($Sr_2SiO_4:Eu^{2+}$) by using an atmospheric pressure dielectric barrier discharge (DBD) plasma with argon as a carrier and hexamethyldisiloxane (HMDSO), toluene and n-hexane as precursors. After the plasma treatment of the phosphor powder, the lattice structure of orthosilicate was not altered, as confirmed by an X-ray diffractometer. The coated phosphor powder was characterized by scanning electron microscopy, fluorescence spectrophotometry and contact angle analysis (CAA). The CAA of the phosphor powder coated with the HMDSO precursor revealed that the water contact angle increased from $21.3^{\circ}$ to $139.5^{\circ}$ (max. $148.7^{\circ}$) and the glycerol contact angle from $55^{\circ}$ to $143.5^{\circ}$ (max. $145.3^{\circ}$) as a result of the hydrophobic coating, which indicated that hydrophobic layers were successfully formed on the phosphor powder surfaces. Further surface characterizations were performed by Fourier transform infrared spectroscopy and X-ray photoelectron spectrometry, which also evidenced the formation of hydrophobic coating layers. The phosphor coated with HMDSO exhibited a photoluminescence (PL) enhancement, but the use of toluene or n-hexane somewhat decreased the PL intensity. The results of this work suggest that the DBD plasma may be a viable method for the preparation of hydrophobic coating layer on phosphor powder.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Fabrication of Gd2O2S:Tb fine scintillator film and evaluation of image quality for resolution improvement of X-ray imaging based on CMOS (CMOS 기반 X선 영상의 해상력 향상을 위한 Gd2O2S:Tb 미세형광체 필름 제작 및 영상 질 평가)

  • Kang, Sang-Sik;Choi, Young-Zoon;Jung, Bong-Jae;No, Si-Cheul;Cho, Chan-Hoon;Yoon, In-Chan;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.283-287
    • /
    • 2011
  • In this study, fine $Gd_2O_2S$:Tb powder was synthesized by using a low temperature solution-combustion method for a high-resolution digital x-ray imaging detector. From the fabricated phosphor power, the fine scintillator films was fabricated by particle sedimentation method and was investigated the luminescent property. From the experimental results of relative light output as a function of terbium concentration, the highest luminescent efficiency has at 5 wt% Tb concentration, and luminescent intensity decreased rapidly according to quenching effect about higher Tb concentration. Also, the relative light output of $270{\mu}m$-$Gd_2O_2S$:Tb film has 2945 pC/$cm^2$/mR. And light intensity was saturated at higher film thickness. Finally, to evaluate an image acquisition performance of fabricated phosphor, images were obtained by using commercial CMOS sensor and measured the MTF, NPS, and DQE. DQE(0 lp/mm) of fine phosphor film has 37%. But, DQE improvement of fine phosphor film is possible by resolving problem of film fabrication process and has a significant potential in the application of digital radiation imaging system later.

Twenty Four Cases of Idiopathic Bronchiolitis Obliterans Organizing Pneumonia, Reported in Korea and a Review of Literatures (국내 보고된 특발성 폐쇄성세기관지염 기질화폐렴 24예와 문헌 고찰)

  • Chang, Jung-Hyun;Park, Sa-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.709-717
    • /
    • 1999
  • Background & Method : Bronchiolitis obliterans organizing pneumonia(BOOP) is a specific clinicopathologic condition characterized by chronic inflammatory interstitial infiltrates. Cryptogenic form of BOOP presents subacute clinical course of flu-like illness, such as cough, fever, dyspnea with exertion and other constitutional symptoms. Pathologically it shows the presence of granulation tissue filling the lumen of terminal and respiratory bronchioles, extending into distal airspaces. Recently, we reviewed 24 cases of idiopathic type of BOOP, 5 cases of our hospital and another 19 cases on Korean literatures, and compared with reviewed data from foreign literatures. Results : Mean age was 54 years old and there was female preponderance in domestic reports. Their common presenting symptoms were dyspnea and cough, and mean duration of illness was 41 days. On chest examination, inspiratory crackle was a common finding. The laboratory findings were nonspecific except hypoxemia. Lung function studies revealed restrictive defect or combined obstructive and restrictive pattern in most patients. Bilateral patchy and nonsegmental alveolar opacities constituted characterized radiographic finding, highlighted on high resolution computed tomogram. It showed a favorable prognosis with an excellent responsiveness to corticosteroid therapy. The clinical features and laboratory findings were similar between domestic and foreign cases except female preponderance in Korean cases. Conclusion : If the clinical course is atypical or pregressive under proper treatment, clinicians should reevaluate clinical features and radiographic findings under the consideration of BOOP. Tissue confirmation would be recommended for the definitive diagnosis of BOOP.

  • PDF

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.

Hydration Characteristics of Liquid Red Mud Mixed Cement Paste Neutralized with Sulfuric Acid (황산으로 중화시킨 액상 레드머드를 혼입한 시멘트 페이스트의 수화특성)

  • Kang, Suk-Pyo;Hong, Seong-Uk;Kim, Sang-Jin;In, Byung-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.431-439
    • /
    • 2022
  • In this study, Neutralized red mud(LRM+S) at a pH of 6-8 was prepared by adding sulfuric acid to liquefied red mud(LRM) at a pH of 10~12. After adding LRM and LRM+S to the cement paste, the hydration heat, compressive strength, and hydration products were examined. The observed accumulated hydration heat revealed that the calorific value of the cement paste with LRM was low and its and peak was delayed when compared with that of plain cement paste(referred to as Plain), whereas the calorific value of the cement paste with LRM+S was similar to that of Plain. At the age of 28 days, the compressive strength of the cement paste with 20% LRM was 55% of the strength of Plain. Using X-ray diffraction, it was determined that the cement paste with 20% LRM exhibited a Ca(OH)2 peak after 3 days, whereas the cement paste with 20% LRM+S and Plain exhibited a Ca(OH)2 peak after an hour. Thus, the strength degradation of cementitious materials was improved by adding neutralized red mud prepared by adjusting the pH of highly alkaline LRM with sulfuric acid.

Experimental Study on the Proposal of an Assessment Method and Quality Standard for Identifying the Fine Particles of Clay Components in Fine Aggregates (잔골재의 토분 평가방법 및 품질기준 제안을 위한 실험적 연구)

  • Choi, Hyun-Kyu;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.585-596
    • /
    • 2022
  • The purpose of this study is to propose an assessment method to analyze clay collectively referred to as fine particles of clay components contained in fine aggregates, and to propose quality standards for clay use through correlation with the performance of concrete to verify the properties of clay measured according to the method. As a result, it is analyzed that it will be suitably utilized as a method to assess the fine particles of the clay component of fine aggregates through the component analysis of XRF. Regarding the related quality standards, considering the error rate of about 10% of KCS 14 20 10, the related quality standards were analyzed to be safe when Al2O3+Fe2O3+MgO is 23.5% or less and SiO2+K2OSiO2+K22O is 66.5% or more. To build on this study, it is expected that a comprehensive review will be conducted through additional follow-up studies such as on clay of coarse aggregates and durability analysis to establish a system for quality control of the soil fraction of aggregates.

Growth Characteristics and Yield of "Baeck Ji 1" a New High Variety of Angelica dahurica (白芷 新品種 "白芷 1號" 의 主要特性 및 收量性)

  • 정상환
    • Korean Journal of Plant Resources
    • /
    • v.10 no.1
    • /
    • pp.100-104
    • /
    • 1997
  • A new baekji(Angelica dahurica Bentham et Hooker) variety, Baekji l, was developed through a pure line selection at the Gyeongbug Provincial RDA during the period of 1990 to 1995. The variety was characterized to have high plant height. Long root length and large root diameter as compared with a check varicty of Bonghwa baekji but emergence date, flowering date and leaf number of Baekji l was similar to that of the check variety, and it was also more tolerant to nematode and heat stress. Peeled root color of Backji l was yellowbrown but number of the lateral root of the variety was greater. The dried-root yield of Baekji l in yield trial, regional adaptation trial and farmer's field trial was always $21\sim31%$ higher than that of the check variety.

  • PDF

Recurrence Analysis after Video-assisted Thoracic Surgery for the Treatment of Spontaneous Pneumothorax (자연기흉의 비디오흉강경수술 후 재발에 대한 분석)

  • Kim, Sung-Wan;Kim, Duk-Sil;Lim, Chang-Young;Lee, Hyeon-Jae;Lee, Gun;Kong, Joon-Hyuk
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.710-715
    • /
    • 2010
  • Background: Video-assisted thoracic surgery (VATS) became common in the treatment of spontaneous pneumothorax (SP). Therefor we've reviewed the recurrence rate after VATS and analysed the factors affecting recurrent pneumothorax after VATS on this study. Material and Method: This retrospective analysis was performed on 321 patients of SP who had undergone VATS from Jan. 2001 to Dec. 2008. The two groups were divided as follow: group A, non-recurrent group (298 patients: 93%); and group B, recurrent group (26 patients: 7%); the two groups were analysed retrospectively. Result: The average age of the study groups were $20.9{\pm}4.3$ years old in recurrent group vs. $25.9{\pm}11.7$ years old in non-recurrent group with statistical significance (p < 0.05). There were no statistical significance in male to female ratio, height/weight ratio, location of pneumothorax, smoking history, operative time, duration of drain, hospital stay, indication of opertion and incidence rate. Average length of duration in recurrence was 12.9 months. There was 22 (95.7%) recurrent patients after VATS within 4 year period among recurrent group. Treatment methods in 23 of recurrent patients were, 8 (VATS), 2 (Axillary thoracotomy) with 15% or more in amount of pneumothorax and 7 (7 Fr. chest tube), 6 (nasal 02) with 15% or less in amount of pneumothorax. Among 10 cases of reoperation, there were 3 cases of over looking type and 7 cases of new growing type. There was no additional recurrence after these procedures were given. Conclusion: There was higher recurrence rate in younger age after VATS thus for those under 20 yrs old, detailed and possible preoperative warning for recurrence is warranted. Most recurrence occured within 4 year period, thus for this reason, regular interval based follow up with chest x-ray study is suggested during this period.