• Title/Summary/Keyword: 투자회수기간

Search Result 101, Processing Time 0.032 seconds

Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment (공동주택에서 지열 냉난방 시스템 적용시 경제성 분석)

  • Park, Yongboo;Park, Jongbae;Lim, Haesik;Baek, Sungkoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.11-18
    • /
    • 2007
  • This paper studied the economical efficiency of ground source heat pump system under various conditions in apartments which have important effects on the housing market. And this study analysed the initial cost increase, saved managing cost and recovery time of initial cost. Analysis result showed as time of heating-cooling and water heating increases, the amount of saved managing cost increased much than the initial construction cost, so recovery time shortened. And as the net area of apartment increases, the recovery time increased. The study of the relation between the installation type and recovery time of initial construction cost showed when heat-cooling system adapted ground source heat and water heating system adapted waste heat, the initial construction cost was recovered most quickly. When Ground Source Heating system was used for the heating-cooling and water heating system, ground source heating system was used for the heating-cooling and waste heat used for water heating, and ground source heating system was used for the heating-cooling and LNG used for water heating, the construction cost increased 72,000, 66,900 and 62,300 won each per $m^2$ compared to the current system (package air-conditioner, heating and water heating using LNG).

  • PDF

Economic Evaluation of ATES Heat Pump System (ATES 열펌프 시스템의 경제성 평가)

  • Kim, Namtae;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.199-199
    • /
    • 2011
  • ATES(Aquifer Thermal Energy Storage) 열펌프 시스템은 기존의 다양한 열원 적용 시스템 대비 효율이 우수한 것으로 알려져 유럽과 미국에서 건물 냉난방 시스템으로 적용되고 있다. 특히, ATES 시스템은 기존의 냉난방 시스템 대비 경제성이 우수한 것으로 알려져 있으나 국내에서는 이에 대한 연구 결과는 전무한 실정이다. 본 연구에서는 ATES 열펌프 시스템의 실증 성능 결과를 분석하였으며, LNG 보일러와 에어컨을 사용하는 기존의 냉난방 시스템을 비교시스템으로 ATES 열펌프 시스템의 경제성 평가를 수행하였다. ATES 시스템의 연간 실증 성능 실험결과 ATES 시스템은 외기온도와 무관하게 연중 안정적인 성능을 나타내었다. 경제성 평가시에 생애주기법(Life Cycle Cost)을 적용하여 ATES 열펌프 시스템의 설치 및 운전에 필요한 총 소요비용을 산정하고, 이 결과를 바탕으로 투자회수기간법을 통해 ATES 시스템의 투자회수 기간을 산정하였다. 생애주기법 적용 시에 현재가치법을 사용하였으며, 현재가치법은 수명주기에 발생하는 모든 투자비용과 절감액을 일정한 시점을 기준으로 등가환산하는 방법을 의미한다. 현재가치법에 사용되는 현재가치는 초기비용과 현재가치계수의 곱으로 나타나는데, 여기에서 현재가치계수는 임의의 이자율로 일정기간 동안 정기적인 할부금액이 적립될 때의 현재금액을 구하기 위해 사용하는 계수를 의미한다. 전기와 LNG는 각각 2009년 7월의 (주)한국전력공사와 (주)한국가스공사의 고시요금을 적용하였다. 본 시스템은 실증 설비용량인 20RT를 대상 건물로 가정하였고, 초기투자비는 크게 공사비와 냉난방 설비 구입비로 구성되어 있으며, 기본적인 물가지표는 (사)한국물가정보(KPI)의 고시 데이터를 참조하였다. 각 시스템의 초기투자비는 ATES 시스템이 비교대상 기존 냉난방 시스템 대비 5.7배 높게 나타났다. 일일 8시간 사용기준으로 계절별 전력요금을 고려한 연간운전 비용은 ATES 시스템이 기존 시스템 대비 냉난방 시에 각각 77%와 16%를 나타내어 운전비용이 연간 절감되었고, 난방 운전 시 절감 비율이 냉방시보다 크게 나타났다. 두 시스템에 대한 생애주기비용을 산정하기 위하여 에어컨과 보일러의 기존시스템과 ATES 시스템의 가용연수를 모두 20년으로 설정하였고, 유지보수 비용은 초기투자비용의 2%로 설정하고, 할인율은 은행 예금이자를 기준으로 5%로 설정하였다. 전기와 LNG의 요금 상승률은 (사)한국물가정보를 바탕으로 각각 2%와 8%로 가정하였다. 이러한 조건에서 생애주기법을 이용한 경제성평가는 ATES 시스템의 경우 생애운전비용이 초기투자비용보다 작게 나타났으며, 기존 냉난방 시스템은 생애운전비용이 초기투자비용에 비하여 높게 나타났다. 본 연구 대상 ATES 열펌프 시스템의 실증 성능 데이터와 기존 문헌으로부터 얻은 냉난방 시스템의 성능 결과를 이용하여 생애주기 비용을 적용한 결과 ATES 시스템의 기존 시스템 대비 투자회수 기간은 6.62년으로 나타났다. 특히, 본 연구에서는 ATES 시스템이 국내 최초로 적용됨에 따라 스크린 등의 부품을 다소 고가의 제품으로 시스템에 적용하였으므로 ATES 시스템의 신뢰성과 안정성이 확보되면 초기 투자비 감소가 가능할 것으로 예상되며, 기존 시스템 대비 투자회수 기간은 더욱 감소될 수 있을 것으로 예상된다.

  • PDF

Study for Investments Flow Patterns in New-Product Development (신제품개발시 소요투자비 흐름의 기업특성별 연구)

  • Oh, Nakkyo;Park, Wonkoo
    • Korean small business review
    • /
    • v.40 no.3
    • /
    • pp.1-24
    • /
    • 2018
  • The purpose of this study is verifying with corporate financial data that the required investment amount flow shows a similar pattern as times passed, in new product development by start-up company. In the previous paper, the same authors proposed the required investment amount flow as a 'New Product Investment Curve (NPIC)'. In this study, we have studied further in various types of companies. The samples used are accounting data of 462 companies selected from 5,873 Korean companies which were finished external audit in 2015. The results of this study are as follows; The average investment period was 3 years for the listed companies, while 6 years for the unlisted companies. The investment payback period was 6 years for listed companies, while 17 years for unlisted companies. The investment payback period of the company supported by big affiliate company (We call 'greenhouse company') was 14~15 years, while 17 years for real venture companies. When we divide all companies into 4 groups in terms of R&D cost and variable cost ratio, NPIC explanatory power of 'high R&D and high variable cost ratio group (Automobile Assembly Business) is best. Among the eight investment cost indexes proposed to estimate the investment amount, the 'cash 1' (operating cash flow+fixed asset excluding land & building+intangible asset, deferred asset change)/year-end total assets) turned out to be the most effective index to estimate the investment flow patterns. The conclusion is that NPIC explanatory power is somewhat reduced when we estimate all companies together. However, if we estimate the sample companies by characteristics such as listed, unlisted, greenhouse, and venture company, the proposed NPIC was verified to be effective by showing the required investment amount pattern.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

The evaluation of economy for the investment of cold storage system to industry from a customer (산업용 전력수용가의 측냉기기 투자 경제성평가)

  • Yang, Seung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.241-243
    • /
    • 2005
  • 효율적인 전력 부하관리기기인 산업분야로의 축냉기기보급은 국가와 전력회사, 그리고 고객 모두에게 편익이 극대화 되어야 한다. 하지만 국가와 전력회사 모두에 편익이 기대된다고 해도 고객의 투자 Merit가 적은 경우 기기보급효과는 얻기 어렵다 전력시장에서 고객이 스스로 본 부하기기를 도입하고, 관련 선비투자를 확대하기 위해서는 초기 설비투자비 대비 적정 투자 비회수 시기, 적정 지원금, 설비신뢰성 및 효율성에 대한 객관적 평가자료 확보 및 정부의 관련정책시행 일관성이 요구된다. 본 논문에서는 산업용 전력을 사용하는 일반 고객이 비축냉 Chiller가 아닌 축냉기기를 도입한 경우의 경제성을 평가할 수 있는 설비투자비 회수기간 평가 알고리즘과 이 프로그램의 실제 적용결과에 대해 기술하였고, 이들 연구결과를 통해 효과적인 부하관리사업을 촉진할 수 있는 기틀을 마련하였다.

  • PDF

ESCO ; Energy Service Company (에너지절약 전문기업)

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.280
    • /
    • pp.67-73
    • /
    • 2013
  • 에너지절약전문기업(ESCO ; Energy Service Company)은 프로젝트 초기에 제3자의 에너지사용시설에 먼저 투자를 한 후 이 투자시설에서 발생하는 에너지절감액으로 투자비와 이윤을 회수하는 기업이다. ESCO로 지정받은 에너지 전문업체는 특정건물이나 시설에서 에너지 절약시설을 도입할 때 비용 전액을 일단 ESCO 업체가 투자하고, 그 후 여기서 얻어지는 에너지절감 예산에서 투자비를 일정기간 분할 상환받는다. 우리나라는 지난 1993년 ESCO 사업 지원 제도를 도입하여 지난 1998년부터 정부의 활성화 정책과 국내 유가상승 등에 힘입어 매년 1,000억원 이상의 투자실적을 보이고 있다. 본지는 ESCO사업에 대해 자세히 알아본다.

  • PDF

Lock-up Expiration and VC Investments: Impact on Stock Prices (의무보유 종료와 VC투자가 주가에 미치는 영향)

  • Lee, Jinsuk;Hong, Min-Goo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.6
    • /
    • pp.133-145
    • /
    • 2023
  • This paper examines whether investors have adapted to the venture capital(VC) investment style. VC firms invest in privately held companies and generate returns by selling them after the lock-up period expires. We analyze the impact on stock prices before and after the lock-up period expiration, and compare the Cumulative Abnormal Return(CAR) between the past period(2015-2017) and the recent period(2020-2022) to investigate the effect of the second venture boom. The main findings are as follows. First, unlike in the past, stock price returns around the lock-up period expiration have been lower than the KOSDAQ index in recent years. Second, the impact on stock prices is significant for both 1-month and 12-month lock-up periods. Specifically, it is confirmed that stocks held by venture capital and professional investors with a 1-month lock-up period respond in advance to their information after the second venture boom. Finally, we find that there is a difference in CAR depending on whether or not the company received VC investment after the second venture boom. Based on our findings, we suggest that VC firms need to revise their exit strategies to improve performance. This includes finding ways to reduce information asymmetry and fees, as well as developing strategies to mitigate market volatility. Additionally, the current lock-up period for VCs should be reconsidered as it may increase the risk of stock price decline. We recommend that the government revise the scope and duration of lock-up periods to protect investors after IPO.

  • PDF

물 - 물熱펌프의 산業體 廢熱利용에 관한 시스템 設計와 經濟性

  • 조명제
    • Journal of the KSME
    • /
    • v.22 no.6
    • /
    • pp.471-476
    • /
    • 1982
  • 1.열펌프 시스템의 성능은 최적설계를 하므로서 이론적, Rankine C.O.P에 접근시킬 수 있다. 2.. 산업체 중저온 폐열회수이용에는 열펌프가 매우 유망하며 냉온수를 동시에 이용하는 경우는 더욱 유리하다. 3. 우리나라 산업계에서 보통 투자회수기간을 3년으로 본다면 전력시설용량을 500kw 이상의 산업용 소동력, 대동력의 경우 열펌프의 성적계수는 약 3.5 정도가 하한으로 볼 수 있다. 4. 공기 또는 물 열원의 가정용 열펌프는 전력비가 비싸므로 아직은 실용성이 없다.

  • PDF

Development of Model for Optimal Concession Period in PPPs Considering Traffic Risk (교통량 위험을 고려한 도로 민간투자사업 적정 관리운영기간 산정 모형 개발)

  • KU, Sukmo;LEE, Seungjae
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.5
    • /
    • pp.421-436
    • /
    • 2016
  • Public-Private-Partnerships tend to be committed high project development cost and recover the cost through future revenue during the operation period. In general, long-term concession can bring on more revenue to private investors, but short-term concession less revenue due to the short recovering opportunities. The concession period is usually determined by government in advance or by the private sectors's proposal although it is a very crucial factor for the PPPs. Accurate traffic forecasting should be most important in planing and evaluating the operation period in that the forecasted traffic determines the project revenue with user fees in PPPs. In this regards, governments and the private investors are required to consider the traffic forecast risk when determining concession period. This study proposed a model for the optimal concession period in the PPPs transportation projects. Monte Carlo simulation was performed to find out the optimal concession period while traffic forecast uncertainty is considered as a project risk under the expected return of the private sector. The simulation results showed that the optimal concession periods are 17 years and 21 years at 5.5% and 7% discount level, respectively. This study result can be applied for the private investors and/or any other concerned decision makers for PPPs projects to set up a more resonable concession period.

A Case Study on Improvement of operational efficiency of Time-chartered Vessel in the Liner Shipping Company (해운선사 용선선박 설비의 운영효율성 개선 사례연구)

  • Ryu, Yeong-Soo;Chang, Myung-Hee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.237-238
    • /
    • 2016
  • 해운선사들은 IMO를 비롯한 많은 연구단체에서 제시하고 있는 에너지 효율성 개선방안을 기반으로 선사의 실정과 유가의 등락 상황에 따라 투자환수(payback) 기간을 고려하여 에너지 효율성 개선방안을 결정하고 있다. 그러나 저유가 시대에서는 갈수록 투자환수 기간이 늘어나고 있어 현존 운항선에 대한 레트로피트(Retrofit)는 극히 1~2년 내 투자비용 회수가 가능한 항목에 국한되는 경향이다. 특히 용선 선박의 경우 설비의 투자를 통한 에너지 효율성 개선은 용선계약 특성상 이해관계 및 인센티브 차이로 인하여 매우 어려운.

  • PDF