• Title/Summary/Keyword: 투시 시간

Search Result 65, Processing Time 0.018 seconds

An Efficient Perspective Projection using $\textrm{VolumePro}^{TM}$ Hardware (볼륨프로 하드웨어를 이용한 효율적인 투시투영 방법)

  • 임석현;신병석
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.195-203
    • /
    • 2004
  • VolumePro is a real-time volume rendering hardware for consumer PCs. However it cannot be used for the applications requiring perspective projection such as virtual endoscopy since it provides only orthographic projection. Several methods have been presented to approximate perspective projection by decomposing a volume into slabs and applying successive parallel projection to thou. But it takes a lot of time since the entire region of every slab should be processed, which does not contribute to final image. In this paper, we propose an efficient perspective projection method that makes the use of several sub-volumes with cropping feature of VolumePro. It reduces the rendering time in comparison to slab-based method without image quality deterioration since it processes only the parts contained in the view frustum.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

Construction of Panoramic Image for Efficient Video Browsing (효율적인 비디오 브라우징을 위한 파노라믹 영상 구축)

  • Shin, Seong-Yoon;Park, Ki-Hong;Pyo, Seong-Bae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.1 s.45
    • /
    • pp.67-72
    • /
    • 2007
  • In this paper, we present a construction method using perspective model which allows for the representation of the motion of a planar surface under perspective projection. The motion parameters are obtained by minimizing a disparity measure between the region in the current frame and the mapped region in the previous frame. The frames are constructed with dynamic panoramic image using a fixed reference or a time varying reference. By experiment, panoramic image proposed in this paper represents contents more efficiently than static image or video, and has a high volume reduction ratio.

  • PDF

Quantitative Evaluation of Dysphagia Using Scintigraphy (신티그라피를 이용한 연하곤란증의 정량적 평가)

  • Park, Seok-Gun;Hyun, Jung-Keun;Lee, Seong-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.276-289
    • /
    • 1998
  • Purpose: To evaluate dysphagia objectively and quantitatively, and to clarify the effect of neck position and viscosity changes in patients with aspiration and laryngeal penetration. Materials and Methods: We studied 35 patients with dysphagia and 21 normal controls using videofluoroscopy and scintigraphy. Videofluoroscopy was performed with barium with three different viscosity, and scintigraphy was done with water, yogurt, and steamed egg mixed with Tc-99m tin colloid. If aspiration was found during videofluoroscopic examination, patient's neck position was changed and study repeated. Videofluoroscopy was analyzed qualitatively. We calculated 7 quantitative parameters from scintigraphy. According to the videofluoroscopic findings, we divided patients into 3 subgroups; aspiration, laryngeal penetration, and no-aspiration group. Results: The result of videofluoroscopy revealed that the most common finding was the delay in triggering pharyngeal swallow. Pharyngeal transit time (PTT) and pharyngeal swallowing efficiency(PSE) in patients with aspiration were signifi-cantly different from other groups. After neck position change, aspiration could be reduced in all of 7 patients, and laryngeal penetration reduced by about 82%. PTT and PSE were also improved after position change. Aspiration and laryngeal penetration occurred more frequently in thin liquid swallowing than in thick liquid and solid swallowing. Conclusion: PTT and PSE were useful for the evaluation of dysphagia. Aspiration and laryngeal penetration could be reduced when appropriate position assumed. We could decrease the chance of aspiration by changing the patient diet consistency. Scintigraphy might be useful tool to quantitate and follow up these changes.

  • PDF

Comparative Study of Conventional Phlebectomy and Transiliuminated Powered Phlebectomy in Varicose Veins (하지 정맥류의 고식적 수술 방법과 광투시 전동형 정맥제거술의 비교연구)

  • Lee Choong Won;Chung sung Woon
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.415-420
    • /
    • 2005
  • Recently the cases of varicose veins are increasing because the patients with latent disease have come to realize that they want a positive treatment. Accordingly, the purpose of this study is to compare and analyze two methods the conventional phlebectomy (CP) and transiliuminated powered phlebectomy (TIPP). Material and Method: From March 200f to December 2004, 114 patients (167 legs) with varicose vein were operated in Pusan National University Hospital. A retrospective review was performed on the clinical records. We analyzed age, sex, duration of illness, chief complaints, duplex doppler findings, number of skin incisions, operative time, length of hospitalization, complications, and remnant lesions. Result: Operative time was significantly shorter in the TIPP group than CP group (for one leg $108.4\pm27.6\;min\;vs\;83_4\pm24.4\;min,\;for\;both\;legs\;184.7\pm28.4\;min\;vs\; 137.8\pm24.4\;min)$. There was signifcant statistical difference in average number of skin incisions per leg between the CP group and the TIPP group $(5.9\pm2.2\;vs\;4.2\pm1.6)$. Mean duration of hospitalization was Significantly shorter in the TIPP group than CP group $(4.4\pm1.0\;days\;vs\;5.8\pm1.9\;days)$. Complications were pain $(15.9\%)$, remnant lesion $(9.5\%)$, and ecchymosis $(4.8\%)$ in the CP group and ecchymosis $(19.6\%),\;pain\;(7.8\%),\;and\;remnant\;lesion\;(7.8\%)$ in TIPP group. Sclerotherapy or reopertaion was done for the patients who had remnant lesions. Conclusion: Transilluminated powered phlebectomy in varicose vein could reduce operative time and number of skin incisions, and almost completely removed the multiple lesions. Although there were postoperative complications such as ecclymosis, they were absorbed within 2 months and patients were satisfied. Therefore, TIPP is a more effective operative technique than conventional phlebectomy in varicose veins.

Perspective Projection Using $VolumePro^{TM}$ in Virtual Endoscopy (가상 내시경에서 볼륨프로 하드웨어를 이용한 투시투영 기법)

  • 임석현;신병석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04a
    • /
    • pp.709-711
    • /
    • 2002
  • 볼륨렌더링(volume rendering)은 3차원의 물체 내부를 가시화하기 위한 기법이다. 여기서는 물체를 복셀(voxel)이라 불리는 미소한 입방체나 미립자의 집합으로 표현하며 의료영상 등 다양한 분야에 이용된다. 볼륨렌더링은 전통적인 렌더링 방법으로 표현할 수 없는 물체의 내부나 반투명한 물체를 표현할 수 있는 장점이 있다. 하지만 방대한 데이터를 다루기 때문에 컴퓨터의 성능이 좋아야 하고 처리시간이 오래 걸린다. 미츠비시사는 PC에서 쉬어-웝(shear-warf) 방법을 기반으로 실시간 볼륨렌더링을 할 수 있는 전용 하드웨어인 볼륨프로(VolumePro)를 발표했다. 하지만 볼륨프로는 직교투영만을 하기 때문에 투시투영을 하지 못한다는 단점을 가지고 있다. 본 논문에서는 볼륨프로의 크로핑(Cropping)을 이용한 서브볼륨(Subvo1ume)을 활용하여 투시투영에 근접한 효과를 보여주는 방법을 제안한다.

  • PDF

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

Reference levels for patient Radiation Dose in interventional radiological procedures (중재적 방사선 시술 시 환자선량에 대한 참고 준위 비교)

  • Park, Hyeok;Kim, Yong-Wan;Jeon, Ju-Seob
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2012
  • The purpose of this study is to measure and evaluate radiation dose on patients in interventional radiological(IVR) procedures classified by each procedure, and aid as data for safety management. Fluroscopy time(F-time), dose area product(DAP) and number of acquired images from each kind of procedure was checked. Non-vascular procedures showed low value, and vascular procedure showed high value in all procedures except in IVC filter. F-time was longest in EVAR, which showed also the highest DAP value of all procedures. DAP-rate showed high value in TACE. By this result, we attempt to establish standard guideline of radiation dose on patients in IVR procedure.

Transilluminated Powered Phlebectomy Using Arthroscopic Equipment in Varicose Vein of Lower Extremities (하지정맥류에서 관절경 장비를 이용한 광투시 전동형 정맥적출술)

  • 박형주;이철세;이길노;이석열
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.391-396
    • /
    • 2003
  • Background: Recently transilluminated powered phlebectomy was introduced and used as a method of surgical treatment for varicose vein in lower extremities. The advantage of transilluminated powered phlebectomy are minimal scar and good cosmetic effect. However, the disadvantages of transilluminated powered phlebectomy is that a high priced Trivex system must be used which increases the patient's expenses. Therefore, we performed a transilluminated powered phlebectomy using an existing arthroscopic equipment instead of Trivex system and observed the effect of treatment and efficiency of the treatment. Material and Method: From March, 2000 to February, 2003, 78 patients (113 limbs) underwent transilluminated powered phlebectomy with an arthroscopic equipment. Patient's disease history, the number of operative scars and complications were reviewed. Result: The operation was performed in 133 limbs of the 78 patients (34 men, 44 women) and the age of patients were ranged from 16 to 72 years with mean age of 41.8 years. Operative time ranged from 20 to 65 minutes (average 48.7 minutes) per limb. The number of operative scar per limb from 2 to 7 (average 4.9). Postoperative complications are transient ecchymosis (78 cases) that desappeared spontaneously, edema persisting longer than 3 weeks (6 cases), remnant varicose vein (4 cases), skin perforation during operative procedure (2 cases), and contact dermatitis due to compression stocking (4 cases) The mean hospitalization day was 3.09 days. Subjective mean satisfaction degree of operation by the patients using a visual analogue scale was 92.6%. Conclusion: Our findings demonstrated that transilluminated powered phleectomy using arthroscopic equipment was possible and had good cosmetic results with acceptable complications.

Surgical Treatment of Varicose Vein - TIPP(Transilluminated Powered Phlebectomy) - (정맥류 환자의 수술적 치료 -광투시 전도형 정맥적출요법-)

  • 이교준;김해균;정은규;강두영
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • The present study was done to determine the efficacy and safety of varicose vein removal using a minimally invasive, powered vein-extracting device with cutaneous transillumination and tumescent anesthesia techniques and then compared this to a retrospective group of conventional phlebectomy operations. There were 133 limbs in 104 patients(72 women, 32 men) treated with the use of the vein extractor aided by transcutaneous illumination. The hydrodissection was performed with Trivex™ Irrigated illuminator(Smith & Nephe $w^{ R}$) system using normal saline after the 2~3mm sized skin incision. Varicose clusters were extracted by the use of TriveTM esector(Smith & Nephe $w^{ R}$) system under transillumination. After the varisoce vein extraction, the operation area was compressed with surgical pad for bleeding control. The complication rate was 3.84% The mean number of incisions was 3.24 and mean operative time per limb was 65.9 minutes. The mean hospitalization was 1.86 days. The varicose vein extraction using transilluminated powered phlebectomy(TIPP) is a safe, efficacious and cosmetically satisfactory method. The procedure decreases the operating time and the number of incisions required to remove varicose clusters. Further evaluation and long term follow up will be necessary to determine the recurrence rate and long termcomplications.to determine the recurrence rate and long termcomplications.