• Title/Summary/Keyword: 투과 소음

Search Result 259, Processing Time 0.035 seconds

An Inter-floor Noise Prevention System using an Open-source Controller (오픈소스 컨트롤러를 사용한 층간 소음 방지 시스템)

  • Kim, Tae-Hoon;Jang, Hyuk-Jae;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.899-906
    • /
    • 2017
  • This paper proposes an inter-floor noise prevention system using an open-source controller. In the proposed system, Arduino which is a widely used open source controller analyzes sound signals and vibration signals with fast fourier transform. When the magnitude of the band-passed signal excesses the noise reference considering transmission loss of a panel or a wall, the system displays warning messages on an LCD module and a mobile device for users to be aware of the noise condition. In the experiment, the system has succeeded extracting and processing the band-passed signals between 130 Hz ~ 1040 Hz. When the magnitude of the extracted signal that is subtracted from the transmission loss exceeds 45 dB, the system has displayed the warning message on an LCD module and a mobile devicefor noise reduction.

Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements (현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.329-337
    • /
    • 2017
  • In USA and UK, the standards of both reverberation time and background noise level have been established for the appropriate aural environment in classrooms. In order to realize this, guidelines for architectural planning and interior finishing have been also suggested. However, in Korea, there has hardly been any guidelines for satisfying background noise criteria and investigation about sound insulation performance of current walls of classrooms. The present study investigates the structure of outer wall and walls between classrooms of two middle schools in order to analyze the sound insulation performance against both exterior and interior noises. Acoustic parameters including transmission loss, standardized sound level difference, and signal to noise ratio have been measured and analyzed for sound insulation performance of walls and flanking noises. As a result, concerning the walls in between classrooms, it was found that walls of dry construction have greater sound insulation performance rather than the walls of wet construction especially in mid and high frequency bands. Also, It was revealed that thermopane, insulated pair glass, of outer walls, has greater sound insulation performance than the double window consisted of two single pane glass. Regarding flanking noises, the standards were exceeded when all windows, or windows and doors front onto corridor were opened. It denotes that students could be disturbed with the sound transmission by the interior noises.

Controlling a Reflection and Transmission of a Sound Using Acoustic Impedance Control (능동 임피던스 제어를 통한 소음의 반사, 투과 특성 제어)

  • Min, Dong-Ki;Oh, Ha-Young;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.297-297
    • /
    • 2010
  • 이 논문에서는 음향 임피던스를 제어하는 능동형 소음 제어 방법을 연구하였다. 음향 임피던스 제어는 기존의 적응 제어 알고리즘 대신 임피던스의 크기 및 위상 최적화를 통하여 닫힌 관의 끝단에 음파의 반사를 최소화 하는 임피던스를 계산하고 제어함으로써 소음을 저감시킨다. 그리고 음향 임피던스 제어 방법을 끝단이 개방되어 있고, 중앙에 스피커가 있는 관에 적용시킨다. 이 경우에는 개방된 음장에서 음향 전달이 최소화하기 위한 임피던스를 계산하고, 음향 임피던스 제어를 통한 소음 저감을 확인한다. 이를 위해 스피커, 마이크로폰, 진동측정용 레이저 바이브로미터, 그리고 능동 소음 제어 하드웨어로 구성된 시스템을 구축하고 검증하였다.

  • PDF

Development of silencer for apartment floor between bathroom noise (공동주택 화장실 층간 소음 저감기 개발)

  • Kim, Young-Su;Lee, Jae-Kuck;Kim, Chang-Yeol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.715-721
    • /
    • 2008
  • 공동주택에서의 음환경 성능은 실내환경의 질과 연관시켜 설계단계부터 충분한 검토가 필요한 성능항목이다. '국토해양부'는 '공통주택 성능등급 표시제도'에서 Air Duct를 통해 상하층간 전파되는 소음을 제어하기 위한 대책을 요구하고 있다. 이에 화장실에 적합한 구조 및 재질로 소음 저감기를 개발하고, 소음기 성능평가 장치를 구성하여 이론과 비교평가하고, 실제 현장에 설치 시 적용효과를 분석하였다.

  • PDF

The study on the management method and installation guide of temporary noise barrier (가설방음벽의 운영방안 및 설치기준에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Kang, Hee-Man;Jang, Tae-Soon;Lee, Ki-Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.372-375
    • /
    • 2006
  • 건설 공사장에서 발생하는 건설장비의 소음을 저감하여 공사장 인근 지역의 생활환경에 미치는 소음영향을 최소화할 수 있도록 건설업체에서는 최대한의 노력으로 가설방음벽을 설치 운영하고 있으나, 설치된 가설방음벽의 효과분석 및 운영방법에 대한 검토가 부족하여 효율적인 소음저감대책으로서의 가설방음벽 운영이 어려운 실정이다. 따라서, 본 연구에서는 가설방음벽의 기초데이터의 확보와 소음해석을 통한 효율적인 운영방안을 제시하며, 설치기준에 관한 방안을 제시하고자 한다.

  • PDF

Sound Insulation Properties of Polymer Soundproof Panels (폴리머 계열 방음패널의 차음특성 비교 분석)

  • Lee, Woo-Mi;Lee, Ju Haeng;Son, Jin-Hee;Kim, Il-Ho;Park, Jae-Roh;Kim, Kwang Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.8
    • /
    • pp.592-597
    • /
    • 2013
  • It is widely known that the sound insulation of soundproof panel is highly correlated to two factors, surface density of material and the frequency of noise. Accordingly, the character of traffic noise released in actual situation is important requisite for determining thickness to determine surface density and material of soundproof panel. This present study selected polymer panel with advantage of light weight and workability and evaluates according to frequency of traffic noise. Polypropylene (PP) and high-density polyethylene (HDPE) were selected as subjects based on economic valuation and efficiency. The sound transmission loss of selected polymer panels were compared with the currently used panels such as polycarbonate (PC) and polymethyl methacrylate (PMMA) depending on thickness and materials. As a result, PC showed the highest sound transmission loss followed by PMMA, HDPE, and PP in range of mass law. In terms of acoustic performance on thickness, the transmission loss increased with thickness of soundproof panel meanwhile coincidence dip was observed in lower frequency where had reduced transmission loss. Therefore, it is suggested that after determining target frequency, the kind of materials and thickness of soundproof panel need to be designed so that traffic noise can be more efficiently reduced.

A Study on the Noise and Vibration Reduction at Supports Center on a Tall Building Apartment (초고층 빌딩의 헬스장 구조소음 및 진동 대책)

  • 박해동;백재호;이홍기;전종균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.527-532
    • /
    • 2003
  • 아파트의 층간소음저감을 위한 다양한 기술이 개발되고 있다. 콘크리트 건물의 단일층을 경계로 한 소음저감을 위한 공기음의 투과손실을 증가하는 방법이 주로 적용되고 있으나, 철골조 초고층아파트 스포츠 시설 운영시 이에 대한 대책으로 공기음의 대책과 구조음의 대책을 두단계에 걸쳐 수립하였다. 초고층 아파트 내부에 스포츠 시설의 배치는 이를 이용하는 사용자에게 편리성의 주지만 철골조의 특성상 충격성 진동원이 발생하는 스포츠 시설은 상하부층인 아파트에 소음진동의 연향으로 인해 이를 방지하는 설계가 요구된다. 일반적인 아파트의 충간 소음진동문제는 이를 발생시키는 상부거주자의 예절과 충간 소음진동 저감 기술이지만 아파트내부의 동일층을 경계로 위치한 스포츠 시설은 시설의 사용성에 반해 하부층에 미치는 영향을 기술적으로 저감하여야 한다. 입주한 초고층아파트의 스포츠 시설에서 발생하는 소음진동 민원문제를 풀기 위하여, 하부층 민원인이 느끼지 못하는 수준의 소음과 진동 허용치를 상호 결정하고 이를 만족하기 위한 차음 및 구조소음 설계를 수행한 사례이다.

  • PDF

Noise Reduction Performance of a Reactive type Silencer with Perforated Panels (다공판이 내장된 반사형 소음기의 소음저감 성능)

  • Lee, Sun-Ki;Lee, Young-Chul;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

A Study on Noise control for the M.Tr Room of In-door Substation (옥내변전소 주변압기실 소음저감개선연구)

  • Kim, Ki-Hong;Lee, Jun-Shin;Shon, Seok-Man;Kim, Tae-Ryong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1542-1544
    • /
    • 2000
  • 도심지 주택밀집지역에 설치운전중인 옥내변전소 주변압기실에서 발생되고 있는 소음은 변압기 전원주파수 2배 성분을 기저주파수로 하는 하모닉 성분의 소음을 발생시킨다. 이로 인하여 변전소 인근주민들의 변압기 소음으로 인한 민원이 발생하고 있으며 변전소의 신설이나 기존 변전소의 변압기 증설 등으로 민원발생은 점차 증가될 추세에 있다. 본 연구에서는 주변압기실에서 공기풍도나 셔터를 투과하여 실외로 전달되는 소음을 효과적으로 저감시키는 방법론을 개발하였으며 주변압기실 셔터부분에는 흡/차음셔터를, 지하 공기풍도에는 변압기 소음주파수에 맞는 공명기를 적용하는 방법을 현장에 시범 적용하여 그 효과를 입증하였다.

  • PDF

Wave Transmission Approach of Coupled Plate Structures through Non-conservative Joints for Power Flow Analysis (파워흐름해석을 위한 비보존 조인트로 편성된 평판 구조물의 파워투과반사계수 해석)

  • Song, J.H.;Hong, S.Y.;Park, Y.H.;Park, D.H.;Kil, H.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.505-510
    • /
    • 2002
  • The attenuation of waves transmitted through non-conservative joints that are shown in many paractical structures, is affected by the impedance and the orientation of the joint. In this paper, the joints between plate structures are assumed to be modeled as linear spring-dashpot systems and the transmission and reflection of vibration energy in the medium to high frequency ranges are investigated. The calculated power transmission and reflection coefficients are applied to the PFA method for the prediction of energy density and intensity in structures.

  • PDF