Journal of the Korea Society of Computer and Information
/
v.12
no.2
s.46
/
pp.161-170
/
2007
This paper is a matter of remote control apparatus and display remote control system comprising the same. The remote controller is a wireless remote pointing device that is included a function of mouse and a function of remote controller for VOD etc. It is assembled a sending signal part to communicate with display device, a image sensor part to capture a scene of front view and a main body. Also, it includes a control part that analyzes the captured image, calculates a relative moving factor that main body is moved by user, and then controls the mouse cursor on the display device. The remote control apparatus is able to capture a seen of front view, to analyze the captured image, and to move a mouse cursor point on the display device as much as it calculated relative moving factor. Therefor it brings don the cost of production by a product desist that is increased user satisfaction. And it, using the patent and the new product desist, will make an epoch in development of the remote control system for Ubiquitous broadcasting industry.
Journal of the Korea Institute of Information and Communication Engineering
/
v.7
no.5
/
pp.1026-1031
/
2003
Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.
The Journal of the Institute of Internet, Broadcasting and Communication
/
v.17
no.2
/
pp.57-62
/
2017
Recently, the use of electronic control units in vehicle has increased. The ECUs are connected to in vehicle networks to process a large amount of information. In this paper, for an actuator that is interconnected to CAN and FlexRay, a FlexRay-CAN gateway is presented and a data packing algorithm with a bisection method of a FlexRay slot is proposed. And, a network based actuator control system and packing map is implemented. With the proposed packing method, contact force sensor data are transferred within the maximum allowed delay to ensure the stability. The proposed method is useful for control of distributed system.
사무실과 가정의 컴퓨터, 대중화된 휴대폰 사용 그리고 인터넷으로 특징지어지는 정보통신 기술덕택에 현대인은 어느 정도 시간과 공간의 제약을 극복하고 있다. 그러나, 아직도 현대인은 예전에 비해 가까워진 지구촌을 여러 가지 이동체를 타고 이동을 하여야한다. 특히 현대인에게 있어서 자동차는 가정과 직장을 이어주고 업무 목적지와 휴식을 위한 휴양지를 찾아가기 위한 실질적인 이동 수단으로서 가정과 직장에 이은 또 하나의 정보통신기술이 필요한 중요한 영역이다. 따라서 미래형 자동차는 편의 주행, 쾌적 주행을 제공하고 그리고 안전 주행이 보장되는 지능형 자동차의 수요가 예견되고 있으며 이를 구현하기위해 첨단 정보통신, 전자, 제어기술이 요구되고 있다. [1][5][6] 이상과 같은 지능형 자동차 관련 응용 분야는 위 그림과 같이 자동차 여러 부위에 장착되는 첨단 전장품들에 의해서 구현이 된다. 그러나, 기존의 자동차와 달리 미래형 지능형 자동차에서는 많은 전장품들이 장착됨에따라 소요되는 전원의 용량이 증가하게되어 기존 12V에서 42V 시스템으로 바뀔 예정이다. 또한 각종 센서로부터 정보신호를 받아서 정보처리를 하고 Actuator를 제어하기 위해서 많은 전장품들간에 연결되는 신호선들의 배선이 복잡해짐에따라 생산부서에서의 공정비용이 증가하게된다. 또한 향후 석유 에너지의 고갈에 따른 전기 자동차로의 전환이 예상되는데 위에서 언급된 많은 전자장치들간 신호를 주고 받기위해 차량내 여러부위로 퍼져있는 배선들이 차지하는 무게가 상당하므로 차체의 무게를 가볍게 해야하는 차세대 전기 자동차의 성능 향상을 위해서 효율적인 In Vehicular Network 기술이 요구된다. 또한 향후 자동차에 장착된 많은 전자장치들의 고장 진단 및 내장된 SW를 효율적으로 갱신하기 위해서는 여러 전자장치들이 하나의 버스로 연결되는 In Vehicle network이 필수적이다.
Proceedings of the Korean Vacuum Society Conference
/
2016.02a
/
pp.121.1-121.1
/
2016
RAON은 우라늄과 같은 무거운 이온을 가속시키는 한국형 중이온 가속기로서 현재 양산에 필요한 실험 시설이 구축되고 있다. 이온원을 생성하고 생성된 중이온 빔을 손실 없이 가속시키기 위해서는 빔의 경로인 입사기장치, 가속장치, 실험장치에서 요구하는 최적의 진공 설계가 이루어져야 하며, 이를 제어하기 위해 진공 기기들과의 데이터 통신 및 기기를 보호하기 위한 인터록 로직을 구성하여야 한다. RAON의 진공부 인터록 로직 및 제어 시퀀스는 Programmable Logic Controller (PLC)으로 구성되며, Experimental Physics and Industrial Control System (EPICS) 환경에 통합되어 중앙 제어 시스템에서 관리됨과 동시에 Control System Studio (CSS)를 통해 모니터링 될 것이다. 이를 위해서는 CSS 및 PLC 와 데이터를 송수신할 수 있는 EPICS IOC를 구성하여야 한다. 본 문서에서는 진공 기기들의 정보를 로컬 PLC에서 수집하고, 진공 상태 및 진공 기기들의 작동을 위한 User Interface (UI) 및 EPICS IOC를 구성하는 방법에 대해 논의할 것이다. 진공부 제어 사전 테스트를 위해 프로토 타입 진공 제어 시스템을 구성하였으며, 이를 바탕으로 추후 최적화 된 RAON의 진공 제어 시스템을 구축할 수 있을 것으로 기대한다.
Park, Chae-Jung;Lee, Duk-Hee;Yoo, Sung-Ho;Choi, Sun-Ah;Cho, Dong-Rae
Proceedings of the Korea Information Processing Society Conference
/
2010.11a
/
pp.1607-1608
/
2010
본 논문은 통신기반 열차제어방식으로 주목 받고 있는 CBTC 시스템의 지상장치 소프트웨어 기능을 모델기반 개발도구인 SCADE 를 이용하여 설계하는 기법을 제시한다. CBTC 지상장치의 ATO 기능은 모델링 후 다양한 테스트 케이스를 통해서 기능을 검증하였다. 수행된 모델링을 통해서 SCADE 가 CBTC 소프트웨어 시스템을 개발하는데 효과적으로 사용될 수 있음을 제시한다.
Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
Journal of the Korea Institute of Information and Communication Engineering
/
v.17
no.4
/
pp.822-828
/
2013
In this paper, a multi-modem for process automation of non-destructive inspection (NDI) which possibly generates various kinds of data is implemented and verified. Here, a variety of data such as control signals, text data, image data generated by inspection devices, sensors, computers are transmitted to the multi-modem via serial, Ethernet, and coaxial cable. We exploit a communication network in which powerlines are used as backbone transmission media. Thus, the implemented multi-modem has various ports and corresponding interfaces for data transmission. As a result of practical experiments, the multi-modem maintains almost constant data rate with little waveform distortion. In addition, the experiments confirm that the modem operates normally under extreme variation of temperature. It is, therefore, considered that the multi-modem can contribute significantly to implement powerline communication (PLC)-based process automation for NDI in which various kinds of data are practically generated.
This paper deals with the design and development of the remote control and measurement systems using CDMA(Code Division Multiple Access) data modem. We propose a bi-directional data communication link without the public IP address in CDMA modem device by the TCP/IP packet and SMS(Short Message Service) communication. The remote control and measurement systems are implemented by a Telit WM-800 modem as DCE(Data Communication Equipment), and Atmel AT89C51 microcontroller as DTE(Data Terminal Equipment). The user application software for the control and measurement system user, and the firmware software of device drivers for peripherals such as a digital input/output device, AD/DAC(Analog to Digital/Digital to Analog Converter), LCD, and temperature/humidity sensor are written in Microsoft C and Keil C language respectively for further various applications. The experimental result of the proposed control and measurement systems implemented in this paper is evaluated via real-time experiments, which works well as designed.
GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.
본 논문은 통신용전원장치와 같은 대용량의 DC 전원 장치에 적용하기 위하여 3상용 6 Switch로 구성된 Bridge로써 대용량 DC-DC converter에 적합한 Topology에 관한 것이다. 기본 동작은 기존의 Phase shifted ZVS PWM 방식을 사용하며, Bridge의 바깥쪽 양쪽암의 펄스폭을 제어하는데, 같은 펄스를 동시에 주는 방식과 각각 별도로 제어하는 방식, 두암의 위상을 지연시키는 방식에 관하여 연구하였다. 제안된 Topology들은 컴퓨터 시뮬레이션을 수행하여 그 동작특성을 확인하였고, 대용량에 적용할 수 있음을 확인하였다. 장치의 용량은 출력 500[A]/30[V] 회로를 구성하여 각각의 경우에 대하여 컴퓨터 시뮬레이션 결과를 제시하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.