• Title/Summary/Keyword: 통신 냉각 시스템

Search Result 42, Processing Time 0.044 seconds

Development of Thermosyphon for Cooling of High Power Electronic Component in Telecommunication System (통신시스템의 고발열 부품 냉각용 써모사이폰 개발)

  • 한재섭
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.2
    • /
    • pp.27-36
    • /
    • 1998
  • 통신시스템의 고발열 전자부품 냉각을 위해 3종류의 써모싸이폰을 각각의 용도에 따라 개 발하였으며 그 각각의 설계변수에 대한 냉각특성을 실험적으로 구하였다. TS-I에서는 증발부 내부 에 금속스크린 메쉬형심지를 삽입함으로써 시간에 따른 온도 변화를 작게 하여 냉각성능 안정성을 확보하였고, TS-II에서는 9W/cm2의 높은 냉각성능을 가진 루프형 써모사이폰을 개발하였으며 TS-III에서는 작동유체의 종류, 파이프개수 와이어 삽입여부등 써모사이폰의 주요 설계변수에 따 른 냉각특성을 구하였다.

Cooling characteristics of the telecommunication system in a switching room for various air supply and return flow system (교환기실의 급배기방식에 따른 통신 시스템의 냉각 특성)

  • 노홍구;이재헌;고철균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.669-683
    • /
    • 1999
  • Heat dissipation in the domestic switching room has been gradually increased. Therefore, numerical study on the cooling characteristics of the telecommunication system in a switching room for three kinds of the air supply and return flow system was investigated to develop effective flow system. As a result, the cooling performance of the under floor air supply and overhead return flow system was the best.

  • PDF

Development of Micro Cooling System for Telecommunication System using Oscillating Heat Pipe (진동 세관형 히트파이프를 이용한 통신 기기용 마이크로 냉각시스템의 개발)

  • Ha, Soo-Jung;Bae, Nae-Soo;Park, Chul-Min;Kim, Jung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1499-1505
    • /
    • 2003
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices. So, in this paper, characteristics on oscillating heat pipe according to operating conditions(environment temperature, charging ratio of working fluid, inclination) based on experimental study was investigated. From the experimental results, $25^{\circ}C$environment temperature), R-141b(working fluid)40%(charging ratio) was best performace at others of inclination angle and The top heating mode of OCHP performed 80% efficiency of the bottom heating mode.

  • PDF

Design of Retarder Control Logic for Cooling System of Commercial Vehicle (상용차의 냉각 시스템을 고려한 리타더 제어로직 설계)

  • Lee, Chang-Kyu;Jeong, Jong-Kyu;Kim, Gwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.668-669
    • /
    • 2016
  • The retarder as a hydraulic brake system in order to assist a service brakes in commercial vehicle is operated by automatic and manual mode due to driver. Braking energy by retarder operation is transmitted to the engine radiator of vehicle cooling system, passing through the retarder oil heat exchanger. At this moment, the retarder ECU performs the function that is controlled a braking torque with consideration for automatic and manual mode, temperature of retarder oil/water, engine coolant temperature, vehicle speed, and etc. In this paper, it deals with the design of retarder control logic and the results of retarder braking performance test regarding a cooling system of retarder and vehicle.

  • PDF

A Study on Cooling System for Efficiency Improvements of 3kW Outdoor Type Photovoltaic Inverter (3kW급 옥외형 태양광 인버터의 효율개선을 위한 냉각시스템 연구)

  • Kim, Min-Seok;Park, Eui-Jong;Kim, Yong-Jae;Oh, Bo-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.5
    • /
    • pp.617-624
    • /
    • 2014
  • Recently, photovoltaic inverter is received attention in photovoltaic with introduction of feed-in tariff. However, this inverter has problems such as inability to respond flexible at climate change due to its opening, and decrease of efficiency and lifetime due to its abnormal operation. To solve the problem, we desire to develop the eco-inverter which has a temperature control to respond easily on the change of temperature, and use the sealed structure not to affect the environment. In addition, we derive the optimal position of cooling system which is placed inside of inverter to minimize the power consumption, and proposed the effective measure to improve the efficient of inverter by deciding the number of cooling system.

A Consideration on the Application of Thermoelectric Cooler to Obesity Therapy (열전 냉각장치의 비만치료 적용 방법론 고찰)

  • Ko, Yun-Seok;Lee, Woo-Cheol;Kim, In-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1437-1442
    • /
    • 2012
  • The contemporary peoples focus on treatment of obesity in order to prevent the adult disease and to manage the beauty. Although surgical treatment of obesity shows the reliable cure effect, it could cause side effects and has a disadvantage that postoperative recovery period is long. Accordingly, this paper compares and analyzes the non-operative treatments which can be of help to treat obesity. Also, it considers the obesity therapy based on the Peltier cooling system. And finally a basic control circuit based on Peltier module is designed for Peltier cooling-based obesity therapy system.

Temperature Characteristics Analysis of Major Heating Region According to Cooling Device Location of Grid-Connected Photovoltaic Inverter (계통연계형 태양광 인버터의 냉각장치 위치에 따른 주요발열부 온도특성 해석)

  • Kim, Min-Seok;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.799-804
    • /
    • 2014
  • To combine to the power transmission, photovoltaic inverter is demanded, because the photovoltaic system is generated direct current power. However, photovoltaic inverter is sensitive to high temperature. In the temperature rising such as at noon and on summer, efficiency of machine is decreased due to the loss increment. Because this problem causes national energy loss according to the expanding the photovoltaic industry, countermeasure is demanded. There, in this paper, we installed a cooling system using a thermoelement regardless of the temperature. Also, we analyze the cooling effect according to the position of two fans which improve the effect maximize.

Novel control scheme for the absence of the thermoelectric(TEC) of infrared detector in an Uncooled thermal system (비냉각 열상시스템에서의 적외선 검출기의 열전소자(TEC) 부재에 대한 효율적인 제어기법)

  • Kim, Yong-Jin;Seo, Jae-Gil;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2335-2340
    • /
    • 2012
  • The detector is an uncooled detector system that functions inside the thermoelectric cooler (TEC) equipped with features instead of the cooler. The function of the thermoelectric device to control the temperature of the detector based on a function of temperature to prevent degradation of image quality to perform the role, the latest technology trend by removing the thermoelectric device size, cost a lot of effort to reduce has been studied. In this paper, It would be proposed of the actual test result using real chamber environment of for the best TECless algorithm as to minimize the degradation of image quality and obtain the low price of the uncooled detector.

A rectifier capable of interfacing with power management system (전원관리시스템과 인터페이스 가능한 신형 정류기)

  • Cho, Man-Hyun;Min, Byeong-Rok;Kim, Gue-Hong;Ahn, Chi-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1277-1279
    • /
    • 2000
  • 통신용 전원시설의 고장은 거의 모든 통신서비스의 중단을 일으킬 수 있기 때문에 통신용 전일시설의 신뢰성은 매우 중요하다. 그 중 통신시스템에 직류 전원을 직접 공급하는 정류시스템은 가장 중요한 전원시스템으로 분류될 수 있다. 현재 여러 전화국 및 무인국사에서 운용되는 정류시스템은 전원관리시스템에 의해 실선으로 감시되고 있으나 중단없는 서비스제공을 위해서는 전원관리시스템과 통신을 통해 효율적으로 감시 및 제어가 이루어져야 한다. 따라서 한국통신에서는 이러한 요구에 부응하기 위하여 소형, 경량화 및 자연냉각방식등을 채택하여 운용유지보수 효율이 향상되고, 전원관리 시스템이 통신을 통해 시스템 감시 및 제어가 가능한 신형 정류기 개발을 완료하였다.

  • PDF

Development of a PCS Simulator and Data Storage System for Energy Saving in the Ship (선박 에너지 절감을 위한 PCS 시뮬레이터 및 데이터 저장 시스템 개발)

  • Oh, Jin-Seok;Kang, Young-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2189-2196
    • /
    • 2015
  • According to increase environmental pollutions and fuel costs, The study of energy saving in the ship is proceeding actively. PCS is pump control system for cooling system in the ship to improve the energy efficiency by controling rotation speed of sea water pump, fresh water pump and position of 3way valve. In this paper, we develop the PCS simulator that has an environment similar to the cooling system of the actual vessel to ensure reliability of the PCS. Also, PC-based control and data storage system for PCS simulator is developed. To develop this system, National Instrument's cDAQ and LabVIEW are used. Finally, confirm the behavior of the simulator by analyzing the saving data.