• Title/Summary/Keyword: 통계적 일치

Search Result 206, Processing Time 0.032 seconds

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

The Study of Normal Tissue Complication Probability(NTCP) for Radiation Pneumonitis by Effective Volume Method (유효체적 방법과 임상분석을 통한 방사선에 의한 정상 폐조직의 부작용 확률에 관한 연구)

  • Ahn Seung Do;Choi Eun Kyung;Yi Byong Yong;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.243-249
    • /
    • 1997
  • Purpose : In radiation therapy, NTCF is very importart indicator of selecting the optimal treatment plan. In our study, we tried to find out usefullness of NTCP in lung cancer by comparng the incidence of radiation pneumonitis with NTCP. Materials and Methods : From August 1993 to December 1994, thirty six patients with locally advanced non=small cell lung cancer were treated by concurrent chemoradiation therapy. Total dose of radiation therapy was 6480cGy (120cGy, bid) and chemotherapeutlc agents were mitomycin C. vinblastion, cisplatin (2 cycles, 4 weeks interval). We evaluated the development of raniation pneumonitis by CT scan, chest x-rar and clinical symptoms. We used grading system of South Western Oncology Group (SWOG) for radiation pneumanitis. Dose Volume Histograms (DVH) were analyzed for ipsilateral and whole lung, Non uniform DVH was translated to uniform DVH by effective volume method. With these data, we calculated NTCP for ipsilateral and whole lung. Finally we compared the clinical results to NTCP. Results : Eight of thrity six patients developed radiation pneumonitis. Of these 8 patients , 6 had grade I severity and 2 had grade II. The average NTCP value cf the patients who showed radiation pneumonitis was significantly higher than that uf the patients without pneumonitis $(66\%\;vs.\;26.4\%)$. But the results of pulmonary function test was not correlated with NTCP. Conclusion : NTCP of lung is very good indicator for selecting rival treatment planning in lung cancer. According to the results of NTCP, it may be possible to adjust target volume and optimize target dose. In the near future, we are going to anaiyze the effect of hyperfractionation and concurrent chemotherapy in addition to NTCP.

  • PDF

Susceptibility-Weighted MR Imaging for the Detection of Developmental Venous Anomaly: Comparison with T2 and FLAIR Imaging (자화율강조 MR영상을 이용한 뇌정맥 기형의 진단: T2강조영상과 FLAIR영상과의 비교)

  • Cho, Soo Bueum;Choi, Dae Seob;Ryu, Hyeon Gyu;Shin, Hwa Seon;Kim, Ji-Eun;Choi, Hye Young;Park, Mi Jung;Choi, Ho Cheol;Son, Seungnam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2014
  • Purpose : We evaluated the diagnostic value of susceptibility-weighted imaging (SWI) for the detection of developmental venous anomaly (DVA). Materials and Methods: Retrospective review of 1068 brain MR examinations found 28 DVAs in 28 patients (2.6%) on contrast-enhanced T1-weighted images. SWI, T2, and FLAIR images of 28 patients with DVA and 28 sex- and age-matched control patients without DVA were analyzed by blinded readers on each type of sequences. All images were independently reviewed by two radiologists who were blinded to other MR imaging finding. In cases of discrepancy, two reviewers reached a consensus later. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of each MR sequence for the detection of DVA were determined. Statistical analysis was performed by using the Mcnemar test. The significance level was p < 0.05. Results: The sensitivity, specificity, PPV, and NPV of SWI for the detection of DVA were 85.7%, 92.9%, 92.3%, and 86.7%, respectively. T2 and FLAIR images showed sensitivity of 35.7% and 35.7%, specificity of 92.9% and 96.4%, PPV of 83.3% and 90.9%, and NPV of 59.1% and 60.0%, respectively. On SWI, the sensitivity and NPV for the detection of DVAs were significantly higher than those of T2 and FLAIR images (p < 0.05). Conclusion: SWI was sensitive and specific for the detection of DVA.

A Study on the In-Vitro Test of Thrombogenesis in Centrifugal Biopump (원심성 바이오 펌프를 이용한 혈전 생성의 생체 외 검사에 관한 연구)

  • Na, Myung-Hoon;Kim, Won-Gon;Kim, Joo-Hyun;Kim, Mee-Hyung;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.863-873
    • /
    • 1999
  • 배경: 혈전 생성은 심혈관계 삽입물이나 순환 보조장치의 발전에 있어서 중요한 문제이므로 이러한 장치들의 혈전성에 대한 평가는 필수적이다. 따라서 이러한 장치들의 혈전성 연구를 시행하기 위한 효과적인 생체 외 실험 방식이 개발되어 원심성 순환 펌프의 발전에 큰 도움이 되고 있으며, 최근 엄밀하게 혈액과 공기의 접촉을 차단하는 방식이 믿을 수 있는 생체 외 실험 방식으로 강조되고 있다. 본 논문에서는 모의 순환 회로를 이용하여 기존에 행해진 연구 방법 상의 공기 접촉에 따른 핼액 응고 기전의 활성화 여부를 알아보기 위하여 공기 접촉 여부에 따른 혈액 인자의 변화를 관찰하여 확인하고, 또한 회로 내에서 생성된 혈전을 생체 내에서 형성된 혈전과 비교 분석하여 이 모의 순환 회로를 이용한 생체 외 검사가 새로 고안된 심혈관계 장치들의 혈전성을 평가하는데 있어서 동물실험을 대신할 수 있다는 기존의 주장을 검증하고자 하였다. 연구재료 및 방법: 바이오펌프를 이용한 같은 모의 순환 회로 한 쌍을 준비하고 동일 개체에서 얻은 헤파린을 첨가한(1u/$m\ell$) 신선한 혈액을 공기와 접촉시키지 않도록 한 A-회로와 공기와 접촉시킨 B-회로에 충전시켜 실험을 동시에 진행하여 결과를 얻었으며 총 12번 시행하였다. 회로에 충전한 혈액의 activated clotting time(ACT)은 정상의 3~5배였으며 ACT가 정상 범위의 1.5배가되면 실험을 끝냈고, Hematocrit(HCT), 혈소판, 동맥혈가스분석(ABGA), factor Ⅷ, factor \ulcorner, 섬유소원, thromboxane B2(TXB2), free hemoglobin(fHb) 등을 측정하였다. 실험이 끝난 후 A-회로와 B-회로에서 얻은 각 검사를 평가하고 분석하였으며 생성된 혈전을 생체 내에서 생성된 혈전과 조직 검사로 비교하였다. 본 연구의 자료분석은 SPSS 통계 프로그램을 이용하였고 유의수준 0.05를 기준으로 유의도를 판단하였다. 결과: 정상 ACT는 186.9$\pm$20.5초(평균$\pm$표준편차)이었고, 헤파린을 넣은 초기 ACT는 982.2$\pm$165.5초이었으며, 실험시간은 보통 60분에서 180분 사이였다. HCT, fHb, 혈소판, TXB2, factor Ⅷ, factor \ulcorner, 섬유원소의 초기값은 35.5$\pm$3.2%, 12.4$\pm$6.5 mg/dL, 354$\pm$56($\times$103)/$\mu$L, 72.6$\pm$15.1 mg/dL, 29.3$\pm$1.2%, 137.9$\pm$42.1 mg/dL, 그리고 17.7$\pm$9.7%이었다. 공기 접촉에 따른 차이를 보았을 때 ACT(p=0.398), HCT(p=0.988), fHb(p=0.898), 혈소판 (p=0.904), TXB2(p=0.985), factor Ⅷ(p=0.872), factor \ulcorner(p=0.489), 섬유원소(p=0.973)으로 전 예에서 통계적 유의성이 없었다. 실험 후 양 군에서 생성된 혈전의 현미경 소견은 B-회로의 혈전에 여러 군데 공기 방울이 관찰되는 것 이외에 A-회로에서 생성된 혈전과 차이가 없었고, 생체에서 생성된 혈전과 비교했을 때 그 양상이 같았다. A-회로와 B-회로에서 생성된 혈전의 총 량은 8.4$\pm$3.7 mL와 9.4$\pm$3.1 mL로 통계상 유의성은 없었다. (p=0.624). 결론: 모의 순환 회로를 이용한 혈전성 평가를 위한 생체 외 실험에 있어서 공기와의 접촉 여부는 혈액 응고 기전의 활성화나 혈전 생성에 별다른 영향을 미치지 않는다. 모의 순환 회로에서 형성된 혈전과 문헌에 있는 인체 내에서 형성된 혈전을 비교한 결과 그 형태가 일치하므로 이 모의 순환회로를 이용한 실험이 동물실험을 대신할 수 있다고 판단된다.

  • PDF

Therapeutic Effect of Prednisolone in Tuberculous Pleurisy -A prospective study for the prevention of the pleural adhesion- (결핵성 흉막염에서 프레드니솔론의 치료효과 -흉막유착 발생에 대한 전향적 연구-)

  • Lee, Byoung-Hoon;Jee, Hyun-Suk;Choi, Jae-Chul;Park, Yong-Bum;An, Chang-Hyeok;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.481-488
    • /
    • 1999
  • Background: The routine application of the combined regimen of corticosteroid-antituberculosis therapy to the tuberculous pleurisy remains controversial. Steroid therapy to tuberculous pleurisy could be effective on the acceleration of absorption of pleural effusion and symptom improvement, but there has been debate about the effect of prednisolone on the prevention of pleural adhesion. So we studied the efficacy of combined regimen of prednisolone-antituberculosis therapy on the absorption of pleural effusion and prevention of pleural adhesion. Method: A prospective, randomized study was performed in 82 patients, 50 patients(non-steroid group) were treated with only antituberculosis regimen for 6 months and in 32 patients(steroid group) prednisolone(30mg/day) were administered in addition to antituberculosis regimen for one months and tapered for another month. The amount of pleural effusion was compared at the beginning of treatment, 2nd month, 6th month and final visit with chest X-ray findings which were graded from grade 0(complete absorption) to grade 6(near total haziness). Results: The amount of pleural effusion of steroid group at 2nd month, 6th month and final visit was lesser than that of non-steroid group(P<0.05). The incidence of the complete absorption of the pleural effusion was 3/32(9.4%) in steroid group, 1/50(2%) in non-steroid group at 2nd month after treatment; and 12/32(37.5%) in steroid group, 6/50(12%) in non-steroid group at 6th month after treatment(P<0.05). At final observation, the incidence of residual pleural thickening was 15/32(47%) in steroid group and 37/50(74%) in non-steroid group(P<0.05). No serious side effects were noted during the treatment with prednisolone. Conclusion: The administration of prednisolone in conjunction with antituberculosis chemotherapy improved the absorption of pleural effusion and decreased the residual pleural thickening.

  • PDF

A Study on Forecasting Accuracy Improvement of Case Based Reasoning Approach Using Fuzzy Relation (퍼지 관계를 활용한 사례기반추론 예측 정확성 향상에 관한 연구)

  • Lee, In-Ho;Shin, Kyung-Shik
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.4
    • /
    • pp.67-84
    • /
    • 2010
  • In terms of business, forecasting is a work of what is expected to happen in the future to make managerial decisions and plans. Therefore, the accurate forecasting is very important for major managerial decision making and is the basis for making various strategies of business. But it is very difficult to make an unbiased and consistent estimate because of uncertainty and complexity in the future business environment. That is why we should use scientific forecasting model to support business decision making, and make an effort to minimize the model's forecasting error which is difference between observation and estimator. Nevertheless, minimizing the error is not an easy task. Case-based reasoning is a problem solving method that utilizes the past similar case to solve the current problem. To build the successful case-based reasoning models, retrieving the case not only the most similar case but also the most relevant case is very important. To retrieve the similar and relevant case from past cases, the measurement of similarities between cases is an important key factor. Especially, if the cases contain symbolic data, it is more difficult to measure the distances. The purpose of this study is to improve the forecasting accuracy of case-based reasoning approach using fuzzy relation and composition. Especially, two methods are adopted to measure the similarity between cases containing symbolic data. One is to deduct the similarity matrix following binary logic(the judgment of sameness between two symbolic data), the other is to deduct the similarity matrix following fuzzy relation and composition. This study is conducted in the following order; data gathering and preprocessing, model building and analysis, validation analysis, conclusion. First, in the progress of data gathering and preprocessing we collect data set including categorical dependent variables. Also, the data set gathered is cross-section data and independent variables of the data set include several qualitative variables expressed symbolic data. The research data consists of many financial ratios and the corresponding bond ratings of Korean companies. The ratings we employ in this study cover all bonds rated by one of the bond rating agencies in Korea. Our total sample includes 1,816 companies whose commercial papers have been rated in the period 1997~2000. Credit grades are defined as outputs and classified into 5 rating categories(A1, A2, A3, B, C) according to credit levels. Second, in the progress of model building and analysis we deduct the similarity matrix following binary logic and fuzzy composition to measure the similarity between cases containing symbolic data. In this process, the used types of fuzzy composition are max-min, max-product, max-average. And then, the analysis is carried out by case-based reasoning approach with the deducted similarity matrix. Third, in the progress of validation analysis we verify the validation of model through McNemar test based on hit ratio. Finally, we draw a conclusion from the study. As a result, the similarity measuring method using fuzzy relation and composition shows good forecasting performance compared to the similarity measuring method using binary logic for similarity measurement between two symbolic data. But the results of the analysis are not statistically significant in forecasting performance among the types of fuzzy composition. The contributions of this study are as follows. We propose another methodology that fuzzy relation and fuzzy composition could be applied for the similarity measurement between two symbolic data. That is the most important factor to build case-based reasoning model.

Benchmark Results of a Monte Carlo Treatment Planning system (몬데카를로 기반 치료계획시스템의 성능평가)

  • Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.149-155
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. To compare the speed and accuracies of dose calculations between different developed codes, a benchmark tests were proposed at the XIIth ICCR (International Conference on the use of Computers in Radiation Therapy, Heidelberg, Germany 2000). A Monte Carlo treatment planning comprised of 28 various Intel Pentium CPUs was implemented for routine clinical use. The purpose of this study was to evaluate the performance of our system using the above benchmark tests. The benchmark procedures are comprised of three parts. a) speed of photon beams dose calculation inside a given phantom of 30.5 cm$\times$39.5 cm $\times$ 30 cm deep and filled with 5 ㎣ voxels within 2% statistical uncertainty. b) speed of electron beams dose calculation inside the same phantom as that of the photon beams. c) accuracy of photon and electron beam calculation inside heterogeneous slab phantom compared with the reference results of EGS4/PRESTA calculation. As results of the speed benchmark tests, it took 5.5 minutes to achieve less than 2% statistical uncertainty for 18 MV photon beams. Though the net calculation for electron beams was an order of faster than the photon beam, the overall calculation time was similar to that of photon beam case due to the overhead time to maintain parallel processing. Since our Monte Carlo code is EGSnrc, which is an improved version of EGS4, the accuracy tests of our system showed, as expected, very good agreement with the reference data. In conclusion, our Monte Carlo treatment planning system shows clinically meaningful results. Though other more efficient codes are developed such like MCDOSE and VMC++, BEAMnrc based on EGSnrc code system may be used for routine clinical Monte Carlo treatment planning in conjunction with clustering technique.

  • PDF

Acromial Morphology in Different MR Oblique Sagittal Slices: Correlation with Rotator Cuff Disorder (자기 공명 영상의 사 시상면에서의 견봉 형태의 변화: 회전근 개 질환과의 임상적 연관성 분석)

  • Jo, Chris H.;Kim, Ji-Beom;Choi, Hye-Yeon;Ko, Young-Whan;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baik;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • Purpose: On the hypothesis that the acromion morphology is changed according to the its site, we identified the morphology of the acromion on the oblique slices of MRI and we investigated the association of the acromial shape with the clinical stages of rotator cuff disorder on the magnetic resonance (MR) images. In addition, we compared the acromion morphology on MRI and simple X-rays. Material and Methods: The MR images of seventy one patients with rotator cuff disorder and who underwent arthroscopic surgery were compared with that of a control group of sixteen patients who didn't have rotator cuff disorder on MRI. On three subsequent oblique sagittal slices from the lateral edge of the acromion (S1, S2 and S3), each acromion morphology on the MRI slices was classified according to Epstein et al: flat, curved or hooked. We investigated the changing parttern of the acromion shape and we compared the acromion shape on MRI and that on simple X-rays. We classified the rotator cuff tear by the severity: bursitis, partial thickness tear or full thickness tear. We investigated which acromial type on the MRI oblique slice was associated with the severity of rotator cuff disease. Results: Changes of the acromial shape occurred in 54 patients (76.1%). The most frequent pattern was that the types are same on S1 and S2 and different on S3 (22 cases, 31.0%). The acromial type on S1 and S2 was significantly associated with the severity of rotator cuff disorder (p=0.001 and 0.022), respectively. There was no reliability of the acromial shape on MRI and roentgenography (p>0.05) Conclusion: The type of acromion changed from lateral to medial. Among the three positions, the shape of the acromion on S1 and S2 had meaningful correlation with the clinical stage of rotator cuff disorder. There was no statistical correlation of the acromial shape between MRI and simple X-ray.

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.