• Title/Summary/Keyword: 통계적 교정

Search Result 130, Processing Time 0.028 seconds

A MOLECULAR BIOLOGIC STUDY ON BIOCOMPATIBILITY OF METALLIC DENTAL MATERIALS USED FOR CHILDREN WITH CULTURED HUMAN GINGIVAL FIBROBLASTS (인체 섬유모세포(HGF-1) 배양에서 소아용 치과금속재의 세포친화성에 대한 분자생물학적 연구)

  • Kim, Ju-Mi;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.243-254
    • /
    • 2002
  • For the purpose of evaluating the biocompatability of 3 kinds of metallic materials frequently used in pediatric dentistry (stainless steel crown, orthodontic band, orthodontic wire), cellular and molecular studies, including cell growth and proliferation, screening of cell death with determination of types whether necrosis or apoptosis and changes in expressions of related signaling molecules were examined, using cultured human gingival fibroblasts (HGF-1), HGF-1 was cultured in Dulbecco's modified Eagle's medium. among which the 3rd to 6th generations of HGF-1 were used. The specimen were divided into stainless steel crown (R), band (B) and wire (W). The immunocytochemical study was done for the detection of anti-PCNA (proliferating cell nuclear antigen) labeling. With extracted protein, western blot was done for the detection of ERK1/2, JNK, and p38, using individual antibodies. Cultured cells proliferated, remarkably till 7 day and slightly at 11 day. There was no statistical significance in the counts of proliferating HGF-1 between control and experimental groups (p>0.05). Relative growth rates were no statistically significant difference between control and experimental groups (p>0.05). PCNA labeling indexes showing similar patterns in control and experimental groups. The expressions of ERK1 and ERK2, p38 were similar in control and experimental groups. The expression of JNK increased at 1st day, slightly decreased at 4th day and markedly increased at 7th and 11 day. Although the patterns of control and experimental groups were similar, the increased expressions of JNK at late period suggest a possible stress due to inhibited cell growth and proliferation, and worse culture condition. Conclusively, the 3 kinds of metal specimens used in this study did not induce cellular and molecular hazards during short term culture of HGF-1. But, for the better clinical stability, the establishment of long period culture and animal experiment was thought necessary.

  • PDF

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.

Optimal Water Allocation considering Reservoir Operation Rules (저수지 운영률을 고려한 최적용수배분)

  • Kang Jaewon;Rieu Seung-yup;Cha Donghoon;Ko Ick Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1430-1434
    • /
    • 2005
  • 금강 유역과 같이 복잡한 하천유역 시스템의 관리를 위해서는 시스템 요소들을 통합적으로 분석할 수 있는 효과적인 의사결정지원 도구가 필요하다. K-MODSIM 모형은 단기 물관리, 장기 운영계획, 가뭄 대비계획 및 물관련 분쟁 해결을 위해 보다 개선된 유역관리 전략을 수립하기 위한 컴퓨터 기반 도구로 개발되었으며, 본 연구에서는 K-MODSIM 모형에 저수지 운영률을 반영하여 유역의 용수배분을 평가하였다. 유역 저수지군 운영 환경 및 제약조건을 반영한 네트워크를 구성한 후, 두 단계의 모형 검정을 수행하였다. 먼저 물리적 검정을 통해서 전체 대상 수계의 상하류 물수지를 검토하고, 다음 단계인 운영 측면의 검정에서 물리적으로 나타나는 상황이 댐 운영이나 제약 조건 등에 부합하는지의 여부를 검토하였다. 대청댐과 용담댐의 통합 운영을 위한 최적 운영률의 개발은 동적계획법 소프트웨어인 CSUDP를 이용하여 수행하였으며, 여기서 사유한 접근법은 음해 추계학적 동적계획법이다. 이 접근방법은 유입량 시계열을 추계학적으로 모의발생시키고, CSUDP 모형은 모의발생시킨 유입량 시계열에 대한 최적운영률을 찾기 위해 사용하며, CSUDP의 최적화 결과에 대한 통계적인 분석을 통해 월단위 운영률을 도출하였다. K-MODSIM 모형에 저수지 운영률을 반영하여 유역의 용수배분을 평가하였다. 유역 저수지군 운영 환경 및 제약조건을 반영한 네트워크를 구성하고, 대청댐과 용담댐의 통합 운영을 위한 최적연계 운영를을 개발하여 다음과 같은 운영 시나리오들을 개발하고 평가하였다. $\cdot$ 금강수계에 대한 용당댐의 영향 평가 $\cdot$ 댐 연계운영시 수요량 변화에 따른 영향 평가 $\cdot$ 하도추적을 고려한 일별모형의 검증 개발된 운영률과 하도추적방법을 K-MODSIM 모형에서 검증하기 위해서 vb.net 스크립트 파일을 개발하여 적용하였다.L이하로 이를 유등천 상류부에 공급할 경우 유등천의 수질은 BOD 6.7mg/L, TN 9.80mg/L, TP 0.90mg/L를 나타낼 것으로 예측된다. 고도처리시설의 도입 후 금강 합류점에서 갑천의 예측 BOD는 7.4mg/L로 현재 9.0mg/L에 비하여 개선되지만 이는 금강수계 오염총량 관리계획의 시$\cdot$도 경계지점 목표수질인 5.9mg/L를 만족시키지 못하므로, 이를 만족시키기 위해서는 방류수 BOD 7.2mg/L이하로 처리해야 할 것으로 판단된다.which support only concepts or image features.방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도 $IL1RN^{*}2$ allele 빈도와

  • PDF

The Accommodative Lag and Refractive Error in Early Adults (초년 성인의 굴절이상과 조절래그 분포의 연관성)

  • Baarg, Saang-Bai;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • Purpose: The purpose of this study was to determine the distribution and correlation of accommodative lag with refractive error. Method: We had tested the clinical refraction and the accommodative lag in clinically normal 49 young adults (total 98 eyes) aged 18 to 25 years without abnormal binocular function. Monocular and binocular accommodative lag were tested with 0.50 D cross-cylinder lens and near vision test chart which had cross-hairs after full correction of LogMAR visual acuity over 0.05. Results: There was no statistical differences in monocular accommodative lag between right ($0.64{\pm}0.64$ D) and left eye ($0.63{\pm}0.64$)(p=0.858). The accommodative lag of male was higher than female and the range of the value was broader than female in binocular accommodative lag (p=0.015). The wider the inter-pupillary distance was, the higher the accommodative lag was (p=0.003). However, there were no differences with age (p=0.800) and dominant eye (p=0.402). The ranges of accommodative lag of low, middle, and high myopia were 0.75 ~ -0.25 D, 1.25 ~ -0.50 D, and 1.50 ~ -0.75 D, respectively, and the regression was 'y = -0.03953x+0.09205'. Conclusions: These data suggest that clinically normal young adults with high amounts of refractive error have more variable accommodative lag and increased spherical equivalent refraction.

Flexibility of resin splint systems for traumatized teeth (외상성 치아모형에서의 레진 스플린트 시스템의 유연성 비교연구)

  • Park, Jin-Hong;Shin, Joo-Hee;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.389-393
    • /
    • 2017
  • Purpose: The aim of this study is to evaluate the flexural strength of flexible resins and the flexibility of different resin splint (RS) systems in comparison with resin wire splint (RWS) system. Materials and methods: Three different resin materials (G-aenial flo, GA, GC; Superbond, SB, Sun medical; G-fix, GF, GC) were tested flexural strength test in accordance with ISO-4049:2000. For the flexibility test of splint systems, a artificial model with resin teeth was used to evaluate three types of resin splint systems (GA, SB, and GF) and one resin wire splint system. The left central incisor was simulated 'injured teeth' with third degree mobility. Three consecutively repeated measurements of periotest value were taken in horizontal direction, before and after splinting to access tooth mobility. The splinting effect was calculated through the periotest value. Differences were evaluated through One-way Anova and Tukey HDS post-hoc tests for pair-wise comparison (${\alpha}=.05$). Results: Although GA group showed significant higher flexural strength than SB and GF groups, all of three different resin splint systems produced a significantly higher and rigid splinting effect compared with 016" resin-wire splint system (P < .05). Conclusion: Within the limits of an in vitro study, it can be stated that resin splint systems are too rigid and may not be acceptable to treat tooth avulsion.

Analysis of micro inorganic materials in linerboard mill (골판지 원지 제조 공정 내 미세 무기물질의 분석)

  • 윤혜정;류정용;김용환;신종호;송봉근
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.11a
    • /
    • pp.132-132
    • /
    • 2000
  • 환경오염과 이상기후의 영향으로 인한 수자원의 고갈과 함께 국내의 경우 수자원 개발 계획 및 수요량을 감안할 때 향후 7 년 내에 물부족 현상을 겪을 것이라는 보고가 있 었으며, 환경부담을 줄이기 위해 폐수의 배출기준은 강화되고 있다. 이러한 상황에서 제조 특성상 타 업종에 비해 폐수 발생량이 높은 편인 국내의 제지산업은 여러 해전부터 이에 대 한 방안을 모색하여 왔다. 일반적으로 폐수 수질 관리와 청수 사용량의 절감을 위해 고가의 폐수 처리 장치를 설치하거나 폐수 재활용을 통해 공정을 극도로 폐쇄화하는 방안으로 연구 가 진행되어 왔다. 이 중 용수의 재활용이 가장 경제적인 방법이지만, 재활용이 지속될수록 각종 무기염과 콜로이드성 유기물질이 축적되어 각종 약품의 효능 저하, 탈수속도의 저하 및 생산 제품의 품질 악화 등의 문제를 유발한다고 알려져 있다. 이를 해결하고자 하는 노 력으로 펄프 원료에 따른 공정수 내 용해성 물질의 분석과 재활용 횟수에 따른 각종 SS와 D DS의 축적 정도에 대한 기초 연구가 수행되었으며, 고폐쇄화된 공정에서 성능을 발휘할 수 있는 첨가제의 개발과 적용 방법에 대한 연구도 수행된 바 있다.여러 지종 가운데 골판지 원지는 용수의 재활용률이 상당히 높은 지종이기 때문에 공정수의 재활용이 진행될수록 열악한 저급 원료로부터 각종의 다양한 물질이 용출 혹은 배 출되며, 이러한‘물질은 골판지 원지의 강도 발현에 더욱 악영향을 미칠 것으로 판단되었다. 미세분으로 구성된 SS의 경우 이미 많은 연구를 통해 특성이 파악되었기 때문에 본 연구에 서는 ss를 제외한 공정수를 두 가지로 크게 나누어 고려하였다. 즉, ss로 측정되지 않지만 닥도를 유발할 수 있는 미세 무기물질과, 용해성의 무기염, 첨가제 및 추출물 둥으로 이루어 진 용해성 성분으로 나누어 분석하였으며, 또한 각각이 초지 특성에 미치는 영향을 살펴보 고자 하였다.을 해석코자 하였으며, 그 방법으 로 수치해석기법을 도입하였다. 또 실제 캘린더링 전후의 두께 변화를 측정하여 유리전이온도 의 도달 깊이와 비교하였다. 지필의 압축 정도는 롤의 직경과 닙 폭을 이용하여 MD 방향으 로 함수화하였으며, 열전달 계수로는 겉보기 값을 사용하였다. 이때 지펼은 균질한 것으로 가 정하였다. 함수율은 유리전이온도를 좌우하는 가장 큰 인자이나 본 연구에서는 항온항습처리 를 통해 유입지의 함수율을 고정시켰으며 캘린더링 시 함수율의 변이는 없다고 가정하였다. 그 결과 열침투깊이가 증가할수록 지필은 보다 변형되기 쉬운 상태가 되어 주어진 압력 조건에 대해 소성변형 정도가 증가하는 것으로 나타났다. 이는 캘린더링 전후에 두께 변화를 측정하여 정량적으로 평가할 수 있었다. 수치해석기법을 통해 같은 압력 조건에서 온도가 증 가함에 따라 혹은 같은 온도 조건에서 압력이 증가함에 따라 지필 내의 유리전이온도의 침투 깊이가 증가함을 알 수 있었으며 이는 캘린더링 전후의 두께 변화의 측정 결과와 일치하였 다. 또 NRT가 증가함에 따라서도 유리전이온도 침투 깊이가 증가하였다.합편에 비해 일부 우수한 양상을 보였지만 본 실험의 범위내에서는 통계적 정량적 차이를 제시할 수는 없었다. 향후 보다 광범위한 동물 실험이 필요할 것으로 사료된다.된다.하고도 완전교정술 도달 확률이 높은 치료전략이라는 사실을 입증하였으며 주대동맥폐동맥혈관부행지의 크기나 숫자가 단일화하기 쉬운 형태학적 특징을 지닌 경우에는 조기에 일단계완전교정술을 시행하여 양호한 결과를 얻을 수 있다는 사실을 발견하였다. 반면 본 환아군 중 단일화술을 먼저 시도한 군에서는 비록 단계적인 단일화를 시도한 군에서 단일화술과 관계된 수술사망율이 약간 낮기는 하였으나 완전교정술까지 완료될 가능성에는 차이가 없었다. 그러나 이 경우 보다 정련된 적응 환자의 선택을 통한 단일화 우선전략의 시도와 장기 추

  • PDF

Main Psychological Factors Contributing to Aggressive Driving (난폭운전에 영향을 미치는 심리적 요인)

  • Sin, Yong-Gyun;Ryu, Jun-Beom;Gang, Su-Cheol
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.4
    • /
    • pp.89-98
    • /
    • 2007
  • Nowadays, aggressive driving is a common driving behavior and it is raised as a dangerous factor for both drivers and passengers. However, it is hard to find studies on aggressive driving in Korea, and even the definition of aggressive behavior is not clearly explained. In this study, the term "aggressive behavior" is defined based on previous studies, and the significance of several psycho-social factors which affect aggressive driving were verified with the 'habit' factor from the Theory of Planned Behavior (TPB). In the pilot study, domestic drivers reported that aggressive behaviors included speeding, traffic light signal violation, and improper passing (cutting drivers off when passing). In this study, controlling the demographic characteristics of these three aggressive behaviors, the authors explored the relationship of the behaviors with TPB factors such as the habit factor. Consequently, in the case of drivers' intentions for speeding and traffic light signal violations, subjective norm, perceived behavioral controllability, and habit were significant factors. In the case of intentions for improper passing, only perceived behavioral controllability and habit were significant. In speeding behavior and traffic light signal violations, only habit was significant besides intention; however, in improper passing, both perceived behavioral controllability and habit were significant besides intention. The authors also tested an alternative model including TPB and habit factors for three types of aggressive driving. Finally, there are several implications for a possible intervention program for aggressive driving, though there are some limitations of the study.

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.

The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens (착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화)

  • Choi, Hyun-Soo;Park, Sung-Jong;Lee, Seok-Ju;Jin, Moon-Seok;Jun, Jin;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.339-343
    • /
    • 2011
  • Purpose: In this study, we investigated changes of phoria based on varying the color and concentration of the color in lenses. Methods: We measured distance phoria for 39 students who aged 20 to 40 with different concentrated lenes - red, gray, brown and green lenses in concentration 20%, 50% and 80%, respectively. Results: Subjects were divided into three groups which were orthophoria, esophoria and exophoria. Orthophoria in all the color and concentration, there were a few of the esophoria. Esophoria of average 2.07${\Delta}$,B.O showed that a slight increase in all colors and concentration, especially in brown lenses showed the greatest increase. Exophoria of average 3.82${\Delta}$,B.I showed that a slight decrease in all colors and concentration, especially in green lenses showed to 2.95${\Delta}$,B.I to the greatest decrease. Different concentration in same color had no specific tendency regarding phoria. Conclusions: The phoria must be considered when selecting color of the lens because of phoria is changeable by color of the lens. It is expected to study the criteria that minimize the asthenopia.

Analysis of the Characteristics of Maxillary Supernumerary Lateral Incisor (상악 측절치 과잉치의 특징 분석)

  • Nah, Jeungseon;Lee, Koeun;Kim, Misun;Nam, Okhyung;Choi, Sungchul;Lee, Hyo-Seol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • This study aimed to investigate a quantitative analysis of the anatomical characteristics of the maxillary supernumerary lateral incisor and its relationship with lateral incisors. Forty-four supernumerary lateral incisors from 43 patients were evaluated for analyzing the position, shape, direction, and relationship between the supernumerary lateral incisor and the normal lateral incisors, using cone-beam computed tomography (CBCT). To compare the size of crown, the mesio-distal width was measured and the Nolla stage was used for evaluating the degree of root development to compare tooth maturity. The supernumerary lateral incisors were in the normal direction at a rate of 90.9%, and in a supplemental shape at a rate of 84.1%. The supernumerary lateral incisor was smaller in size compared to the adjacent lateral incisor and opposite lateral incisor (p < .0001). There was no statistically significant difference in the development stage of root. Based on these results, the supernumerary lateral incisor is similar with the lateral incisor, but has a difference in the size of crown. It is necessary to distinguish the supernumerary lateral incisor from the lateral incisor precisely to reduce clinical complications.