• Title/Summary/Keyword: 통계적인 측정기

Search Result 20, Processing Time 0.024 seconds

A Study on Calibration of Neutron Moisture Gauge Using MCNP4A (MCNP4A 전산코드를 이용한 중성자 수분함량 측정기의 교정식 및 교정상수 도출방법 연구)

  • Whang, Joo-Ho;Lim, Chun-Il;Song, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.289-298
    • /
    • 1997
  • Time-consuming experiments have been required in the development of neutron moisture gauge to induce a relation between the water content in soil and the neutron counts. Applying a monte carlo computer code to simulate the experiments of neutron moisture gauging may contribute to reduce time and efforts for experiments and produce a calibration equation which is more applicable to soil in general. In this study MCNP4A, a monte carlo computer code, was employed to simulate soil experiments and the simulated results were compared with experimental ones. The comparative study showed that MCNP4A is applicable to simulate the experiments and calibration equation can be obtained through simulations. Effects of dry density changes were also studied.

  • PDF

Scanning Probe를 이용한 OMM(On the Machine Measuring) 시스템 개발 및 평가

  • 김선호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.227-231
    • /
    • 1996
  • 기계가공 생산시스템에서 대량생산라인의 경우에는 측정 및 검사공정을 별도로 두고 있으나, 금형과 같은 다품종 소량 생산품의 경우에는 이러한 방식이 적합하지않다. 이러한 경우에는 유연성이 높은 3차원 측정기(CMM)를 설치하여 운용하고 있으나 운용비용이 많이 들고 관리하기가 쉽지 않으며 Setup 및 측정시간이 길어져 비경제적일 수가 있다. 또한 3차원 측정기의 한정된 크기때문에 대형가공물이라든지 탈착이 어려운 생산품의 경우에는 마땅한 특정 방법이 없는 실정이다. 본 연구에서는 개발된 OMM 시스템을 3종류의 TV Shadow Mask 금형의 측정에 적용한 결과를 소개한다. 측정된 결과는 CMM을 이용해 측정한 결과와 비교 했고, 비교된 결과를 이용해 개발된 시스템의 반복정밀도, 측정 정확도를 통계적 방법으로그리고 경제적 관점에서 CMM을 이용 한 기존의 방법과 개발된 시스템을 비교 평가했다.

  • PDF

An Adaptive M-estimators Robust Estimation Algorithm (적응적 M-estimators 강건 예측 알고리즘)

  • Jang Seok-Woo;Kim Jin-Uk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.2 s.34
    • /
    • pp.21-30
    • /
    • 2005
  • In general, the robust estimation method is well known for a good statistical estimator that is insensitive to small departures from the idealized assumptions for which the estimation is optimized. While there are many existing robust estimation techniques that have been proposed in the literature, two main techniques used in computer vision are M-estimators and least-median of squares (LMS). Among these. we utilized the M-estimators since they are known to provide an optimal estimation of affine motion parameters. The M-estimators have higher statistical efficiency but tolerate much lower percentages of outliers unless properly initialized. To resolve these problems, we proposed an adaptive M-estimators algorithm that effectively separates outliers from non-outliers and estimate affine model parameters, using a continuous sigmoid weight function. The experimental results show the superiority of our method.

  • PDF

Characteristics of TSP Concentrations Measured at Gosan: Statistical Analysis (고산에서 측정한 TSP 농도 특성: 통계적 해석)

  • 박민하;김용표;강창희;김원형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.93-100
    • /
    • 2003
  • In this technical information, the long-term measurement data at Gosan between 1992 and 2001 are analyzed with various statistical methods. First. it was confirmed that the basic assumption of t-test is important to classify data correctly. Second, it was founded that the difference of the number of data per month can affect the averaged concentration. Third, by using a non-parametric statistical method long term trend of aerosol composition free from seasonal effects is obtained.

Fundamental Investigation of Non-invasive Determination of Alcohol in Blood by Near Infrared Spectrophotometry (근적외선 분광분석법을 이용한 음주측정기술 개발에 관한 연구)

  • Chang, Soo-Hyun;Cho, Chang-Hee;Woo, Young-Ah;Kim, Hyo-Jin;Kim, Young-Man;Lee, Kang-Boong;Kim, Young-Woon;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.375-381
    • /
    • 1999
  • Near infrared spectrophotometry(NIR) was developed as a non-invasive determination of blood alcohol. The first pure alcohol/water samples were prepared with ethanol concentration from 0.01 to 0.1%(w/w). Analysis of the second-derivative data was accomplished with multilinear regression(MLR). The standard error of calibration(SEC) of ethanol in ethanol/water solutions was approximately 0.0039%. The calibration models were established from the blood alcohol spectra by MLR and PLSR analysis. The best calibration was built with the second-derivative spectra of 2266 and 2326 nm by MLR. Second-derivative spectra in the spectral ranges of 1100~1340, 1500~1796 and 2064~2300 nm with four PLSR factors provided the standard error of prediction(SEP) of 0.030%(w/w). These results indicate that NIR may be applied for a fast non-invasive determination of alcohol in the blood.

  • PDF

Development of a Frequency Dependent Type Apex Locator with Automatic Compensation (자동 보정 주파수 의존형 근관장 측정기의 개발)

  • Kim, Deok-Won;Nam, Gi-Chang;Kim, Yeong-Ju;Lee, Seung-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.595-602
    • /
    • 1998
  • Among the apex locators, the frequency dependent type is more accurate and convenient to use than others, But the accuracy of the apex locator is still influenced by the presence of various electrolytes used in root canal treatments. In this study, we have developed a frequency dependent electronic apex locator minimizing the influence of the electrolytes on the measurement of root canal lengths. It was also confirmed that two frequencies of 500Hz and 100kHz are optimal for the measuring impedance compare with commercial product used(400Hz and 8kHz)a and there were no differences in accuracy among the three different types of the waveforms; sinusoidal, triangular, and rectangular waves(p>0.05). Impedance ratio of the two different frequencies represents the position of the file in root canal, and the voltage difference of two signals represents the status of the fluid in the root canal. As a result of compensation using the voltage differences, the errors were decreased on the average from +0.54mm to +0.18mm in $H_2O_2$ solution (p<0.01), and from -0.33mm to -0.01mm in NaOCl solution(p<0.01). The accuracies based on ${\pm}$0.5mm, in $H_2O_2$ and NaOCl solutions were improved with the automatic compensation from 71.1% and 91.1% to 82.2% and 100% respectively.

  • PDF

Development of Automated Non-contact Thickness Measurement Machine using a Laser Sensor (레이저센서를 이용한 비접촉식 두께자동측정기 개발)

  • Cho, Kyung-Chul;Kim, Soo-Youn;Shin, Ki-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.2
    • /
    • pp.51-58
    • /
    • 2015
  • In this study, we developed an automated non-contact thickness measurement machine that continuously and precisely measures the thickness and warp of a PCB product using a laser sensor. The system contains a measurement part to measure the thickness in real time automatically according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The measurement machine was utilized to evaluate the performance at each step to minimize measurement error. At the zero setting for the initial setup, the standard deviation of the 216 samples was determined to be $5.52{\mu}m$. A measurement error of 0.5mm and 1.0mm as a standard sample in the measurement accuracy assessment was found to be 2.48% and 2.28%, respectively. In the factory acceptance test, the standard deviation of 1.461mm PCB was measured as $28.99{\mu}m$, with a $C_{pk}$ of 1.2. The automatic thickness measurement machine developed in this study can contribute to productivity and quality improvement in the mass production process.

Wild Boar (Sus scrofa corranus Heude ) Habitat Modeling Using GIS and Logistic Regression (GIS와 로지스틱 회귀분석을 이용한 멧돼지 서식지 모형 개발)

  • 서창완;박종화
    • Spatial Information Research
    • /
    • v.8 no.1
    • /
    • pp.85-99
    • /
    • 2000
  • Accurate information on habitat distribution of protected fauna is essential for the habitat management of Korea, a country with very high development pressure. The objectives of this study were to develop a habitat suitability model of wild boar based on GIS and logistic regression, and to create habitat distribution map, and to prepare the basis for habitat management of our country s endangered and protected species. The modeling process of this restudyarch had following three steps. First, GIS database of environmental factors related to use and availability of wild boar habitat were built. Wild boar locations were collected by Radio-Telemetry and GPS. Second, environmental factors affecting the habitat use and availability of wild boars were identified through chi-square test. Third, habitat suitability model based on logistic regression were developed, and the validity of the model was tested. Finally , habitat assessment map was created by utilizing a rule-based approach. The results of the study were as folos. First , distinct difference in wild boar habitat use by season and habitat types were found, however, no difference in wild boar habiat use by season and habitat types were found , however, ho difference by sex and activity types were found. Second, it was found, through habitat availability analysis, that elevation , aspect , forest type, and forest age were significant natural environmental factors affecting wild boar hatibate selection, but the effects of slope, ridge/valley, water, and solar radiation could not be identified, Finally, the habitat at cutoff value of 0.5. The model validation showed that inside validation site had the classification accuracy of 73.07% for total habitat and 80.00% for cover habitat , and outside validation site had the classification accuracy of 75.00% for total habitat.

  • PDF

Comparison of the Values of Bone Mineral Density Between DEXAs (DEXA 측정기 간 골밀도 값 비교)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.271-276
    • /
    • 2011
  • Statistical analysis was performed on the patients who took bone densitometry using Lunar and Hologic equipments for 5 months from January $1^{st}$ 2010 to May $30^{st}$, 2010. Patients consisted of 50 in their 40s, 100 in 50s and 50 in 60s. In addition, the results from bone densitometry were carried out on the same subject with two equipments on the same day. In case of 200 subjects, who received the bone densitometry with two equipments, the average age was 54.5 and 54.4 years old, respectively. There was no difference. The T- score of Lunar equipment was $-1.377{\pm}1.221$ and that of Hologic equipment was $-1.806{\pm}1.123$. The T-score of Lunar equipment was measured higher than that of Hologic equipment. T-test was conducted to determine the equality of the mean of two groups with 200 patients. Since the pvalue was 0.000, the value of bone mineral density was significant in two equipments. Furthermore, the patients, who were diagnosed by Lunar, showed more 'normal' and who were diagnosed by Hologic, showed more osteoporosis, which cartegorized by WHO, such as normal, osteopenia, and osteoporosis. Thus, compared results of bone densitometry on lumbar spine L1 - L4 of four normal people with the same equipment showed that T- score of Lunar equipment was $-0.4{\pm}1.2$, and T- score of Hologic equipment was $-1.1{\pm}1.5$. It showed the higher T- score was measured in Lunar equipment as well. Therefore, the correction factor should be considered to use, since T- scores are different between two equipments.

REMINERALIZATION EFFECT OF SODIUM FLUORIDE VARNISH ON WHITE LESION BY APPLICATION INTERVALS (불화나트륨 바니쉬의 도포 주기에 따른 백색 병소의 재광화 효과)

  • Lee, Eun-Hui;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.403-411
    • /
    • 2010
  • This study is about the treatment effect of fluoride varnish on white lesion. The changes in microhardness values and lesion sizes were compared and analyzed in relation to application interval, frequency, etc. Resin blocks were fabricated with the crown portion of permanent molars. Samples were classified into group I(1 week), group II(2 weeks) and group III(3 weeks) based on fluoride application intervals, each with 15 samples. Samples were soaked into a decalcifying solution for 15 days, and stored in artificial saliva at $37^{\circ}C$ thermostat. The changes in microhardness values and lesion sizes, before/after decalcification and after fluoride application, were evaluated. The following results were obtained. 1. Microhardness values in group II and III exhibited almost twice the increasing rate than group I. There were significant differences between group I and II, and group I and III (p<0.05), but none between group II and III (p>0.05). 2. Change in lesion sizes showed no significant differences between group I and II, III (p>0.05). In conclusion, fluoride varnish application results in both qualitative and quantitative improvements in white lesions. The satisfactory results can be obtained when varnish is applied at more than 2 weeks interval.