• Title/Summary/Keyword: 토크 계수

Search Result 116, Processing Time 0.02 seconds

Performance Assessment of Two Horizontal Shroud Tidal Current Energy Converter using Hydraulic Experiment (수리실험을 통한 수평 2열 쉬라우드 조류에너지 변환장치 성능평가)

  • Lee, Uk-Jae;Choi, Hyuk-Jin;Ko, Dong-Hui
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, the two horizontal shroud tidal current energy converter, which can generate power even under low flow speed conditions, was developed. In order to determine the shape of the shroud system, a three-dimensional numerical simulation test was conducted, and a 1/6 scale down model was made to perform a hydraulic model experiment. The hydraulic model experiment was performed under four flow conditions, and the flow speed, torque, and RPM were measured for each experimental case. As a result of the numerical simulation test, it was found that the flow speeds passing through the nozzle were increased by about 2~3 times in the cylinder, and when the extension ratio was 2:1, the highest flow speed was shown. In addition, it was found that the flow speeds increased 2.8 times when the diameter ratio between the nozzle and the cylinder was 1.5:1. Meanwhile, as a result of the hydraulic model experiment, it was found that when the tip speed ratio was between 1.75 and 2, the power coefficient was 0.32 to 0.34.

Evaluating rheological properties of excavated soil for EPB shield TBM with foam and polymer (폼과 폴리머를 활용한 EPB 쉴드 TBM 굴착토의 유동학적 특성 평가)

  • Byeonghyun Hwang;Minkyu Kang;Kibeom Kwon;Jeonghun Yang;Hangseok Choi
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.5
    • /
    • pp.387-401
    • /
    • 2023
  • The Earth Pressure Balanced (EPB) Shield Tunnel Boring Machine (TBM) is widely employed for constructing urban underground spaces due to its minimal vibration and low noise levels. The injection of additives offers several advantages, including maintaining shield chamber pressure, reducing shear strength, minimizing cutter wear, and decreasing the permeability of the excavated soil. This technique is known as soil conditioning and involves the application of additives such as foam, polymer, and bentonite slurry. In this study, weathered granite soil commonly encountered at domestic tunnel sites was used as a soil specimen. Foam and polymer were applied as additives to assess the rheological properties of conditioned soils. The workability was evaluated through slump tests, while the rheological properties were assessed through laboratory pressurized vane shear tests conducted under the same conditions. Specially, the polymer was applied under specific conditions with low workability with high slump values, with the aim of evaluating the impact of polymer application. The test results revealed that with an increase in the Foam Injection Ratio (FIR), the slump value also increased, while the torque, peak strength, yield stress, apparent viscosity, and thixotropic area decreased. Conversely, an increase in the Polymer Injection Ratio (PIR) led to results opposite to those of FIR. Additionally, a correlation between the slump value and yield stress was proposed. When comparing conditions with only foam applied to those with both foam and polymer applied, even with similar slump values, the yield stress was found to be lower in the latter conditions.

Effect of forearm length applied on empirical models of maximum endurance time during isometric elbow flexion (등척성 팔굽 굽힘시 최대근지구력시간의 실증적 모델에 적용한 전완길이의 영향)

  • Sang-Sik Lee;Kiyoung Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.338-346
    • /
    • 2023
  • During isometric elbow flexion, forearm length should be an important factor to determine not only joint torque but also maximum endurance time (MET), when the forearm is perpendicular to the direction of the force. The purpose of this paper is to examine the effect of forearm length as an additional factor on empirical models of MET such as an exponential model and a power model during isometric elbow flexion. Thirty volunteers participated in our experiment to measure factor variables such as circumferences and lengths of their upper and lower arms. Their METs were measured according to the percent of maximum voluntary contraction intensity (%MVC). For the multiple linear regression model of ln(MET) using these measurements, significant variables could be observed in %MVC and forearm lengths (P<0.05). The empirical models were assessed by these models using forearm length as the additional factor. Mean absolute deviations (MAD) between the measured METs amd the two empirical models were about 19.4 [s], but MAD using models applied forearm lengths were reduced to about 16.2 [s]. The correlation coefficients and intraclass correlation coefficients were about 0.87, but those applied forearm lengths were increased to about 0.91. These results demonstrated that forearm length was a significant additional factor to the empirical model.

Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema (폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계)

  • Ahn, Joong-Hyun;Park, Jeong-Mee;Ko, Seung-Hyeon;Yoon, Jong-Goo;Kwon, Soon-Seug;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.367-376
    • /
    • 1996
  • Background : The diagnosis of emphysema during life is based on a combination of clinical, functional, and radiographic findings, but this combination is relatively insensitive and nonspecific. The development of rapid, high-resolution third and fourth generation CT scanners has enabled us to resolve pulmonary parenchymal abnormalities with great precision. We compared the chest HRCT findings to the pulmonary function test and arterial blood gas analysis in pulmonary emphysema patients to test the ability of HRCT to quantify the degree of pulmonary emphysema. Methods : From october 1994 to october 1995, the study group consisted of 20 subjects in whom HRCT of the thorax and pulmonary function studies had been obtained at St. Mary's hospital. The analysis was from scans at preselected anatomic levels and incorporated both lungs. On each HRCT slice the lung parenchyma was assessed for two aspects of emphysema: severity and extent. The five levels were graded and scored separately for the left and right lung giving a total of 10 lung fields. A combination of severity and extent gave the degree of emphysema. We compared the HRCT quantitation of emphysema, pulmonary function tests, ABGA, CBC, and patients characteristics(age, sex, height, weight, smoking amounts etc.) in 20 patients. Results : 1) There was a significant inverse correlation between HRCT scores for emphysema and percentage predicted values of DLco(r = -0.68, p < 0.05), DLco/VA(r = -0.49, p < 0.05), FEV1(r = -0.53, p < 0.05), and FVC(r = -0.47, p < 0.05). 2) There was a significant correlation between the HRCT scores and percentage predicted values of TLC(r = 0.50, p < 0.05), RV(r = 0.64, p < 0.05). 3) There was a significant inverse correlation between the HRCT scores and PaO2(r = -0.48, p < 0.05) and significant correlation with D(A-a)O2(r = -0.48, p < 0.05) but no significant correlation between the HRCT scores and PaCO2. 4) There was no significant correlation between the HRCT scores and age, sex, height, weight, smoking amounts in patients, hemoglobin, hematocrit, and wbc counts. Conclusion : High-Resolution CT provides a useful method for early detection and quantitating emphysema in life and correlates significantly with pulmonary function tests and arterial blood gas analysis.

  • PDF

Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device (좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과)

  • ;;C. Soutis
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section ($length{\;}{\times}{\;}width$) was investigated on the compressive behavior of a T300/924 $\textrm{[}45/-45/0/90\textrm{]}_{3s}$, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm{\;}and{\;}90mm{\;}{\times}{\;}90mm$ gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

Antioxidant activity of Bamboo powder and its immunoreactivity in the pig (대나무 분말의 항산화력과 돼지의 면역 활성에 미치는 영향)

  • Song, Yuno;Chu, Gyo-Moon;Jang, Sun-Hee;Goo, Ae-Jin;Ko, Yeoung-Gyu;Ha, Ji Hee;Lee, Jae-Young;Kang, Suk-Nam;Song, Young-Min;Cho, Jae-Hyeon
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.2
    • /
    • pp.111-122
    • /
    • 2014
  • The present study was designed to explore the antioxidant effect of Bamboo powder and its immunoreactivity in pigs. We investigated the functional properties of Bamboo extracts by means of measuring the contents of total polyphenols and flavonoid as well as determining ABST, DPPH radical scavenging activity, and hydroxyl radical scavenging activity and anticancer activity. The total phenolic compound and flavonoids contents of Bamboo extracts were 171.25 mg/g and 127.5 mg/g, respectively. The DPPH radical, hydroxyl radical, ABST radical scavenging activity of Bamboo extracts were 17.3%, 12.5% and 21.5%, respectively. Evidenced by MTT and cell cycle assay, Bamboo dose-dependently inhibited the cell proliferation and induced G0/G1-phase arrest in CHO cells at concentrations of 100, 250, and 500 ${\mu}g/ml$ Bamboo extracts. More than 80% of apoptotic cells were observed by staining with annexin V in 500 ${\mu}g/ml$ Bamboo-treated CHO cells, indicating that Bamboo had potent anticancer activities. Next, to investigate the effect of Bamboo on cytokine, immunoglobulin concentration, and blood compositions, flatting pigs were fed with Bamboo powder for 38 days. Flatting pigs were divided into 4 groups; basal diet (control), basal diet supplemented with 1% Bamboo powder (T1), 2% Bamboo powder (T2), and 3% Bamboo powder (T3). The level of hemoglobin increased in the all Bamboo-fed groups compared with the normal control group. In particular, platelet levels in the all Bamboo-treated groups increased by approximately 90% compared with the levels from pig on a normal control. Serum levels of immunoglobulins (IgG, IgA) in the pigs fed Bamboo powder were modestly increased, and the interferon-${\gamma}$ level also was strongly increased in 2% or 3% Bamboo-fed groups compared with the levels in control groups. Together, these results demonstrated that Bamboo extracts had an effective capacity of scavenging for ABTS, DPPH, and hydroxyl radicals and showed correlation with potent phenol and flavonoid contents, thus suggesting its antioxidant potential. Moreover, administration of Bamboo in 2~3% improved blood parameters and platelets, and especially immunity-related ones such as IgG, IgA, and interferon-${\gamma}$, leading to be potential feed additives in flatting pigs.