• Title/Summary/Keyword: 토양 함수비

Search Result 197, Processing Time 0.032 seconds

Calculation of Soil Moisture Control Section to determine Soil Moisture Regime of Medium Textured Soil Catena in Hilly Area (경사지(傾斜地) 중립질토양연접군(中粒質土壤連接群)에 대한 토양수분상(土壤水分相) 결정(決定)을 위한 부위(部位) 선정(選定))

  • Jung, Yeun-Tae;Kim, Jung-Kon;Son, Il-Soo;Yoon, El-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 1989
  • This study was carried out by using laboratory data to calculate Soil Moisture Control Section (SMCS) for medium textured topo-sequential soils derived from porphyry in Milyang area. The soils studied were characterized by loam to silty clay loam, and the moisture content at -1/3 bar in the solum ranged around 21.06% to 32.42%. The moisture contents per centimeter of soil layer within a solum calculated at field capacity (FC) ranged from 0.11cm to 0.19cm. The upper boundaries of SMCS of the soils calculated on the basis of FC as the water content at -1/3 bar, ranged from 16.2cm to 21.2cm and the lower boundaries from 44.4cm to 63.8cm, and the depth of SMCS were from 27.7cm to 42.6cm in the soil profiles. The Bongsan soil on the summit had shallower in the boundaries and narrower in the depth of SMCS than the soils on side-slopes or on valley.

  • PDF

토양오염도 측정을 위한 Frequency Domain Reflectometry with Vector Network Analyzer(FDR-V) system 적용성 평가

  • Kim Man-Il;Kim Hyeong-Su;Jeong Gyo-Cheol
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.36-41
    • /
    • 2005
  • 복소유전율상수인 실수부(Real part)와 허수부(Imaginary part)를 측정하기 위하여 Frequency Domain Reflectometry with Vector Network Analyzer(FDR-V) 측정 장비로 $1{\sim}18GHz$ 범위 내에서 매질의 기본 구성단위인 공기, 물, 흙입자에 대한 기본적인 유전율 특성을 파악하고, 이들로부터 다공질 매질내 유류 오염물질의 함유 특성을 측정할 수 있다. 또한 제작된 시료에 대한 포화도와 1GHz 범위에 분포하는 실수부 유전율상수와의 관계로부터 매질의 공극내 함유된 물질의 유전율상수 특성에 매우 민감한 반응을 보이므로, 이들로부터 매질의 공극률 내지 유효공극률의 측정이 가능할 것으로 사료된다.

  • PDF

Studies on the Drying Mechanism of Stratified Soil-Comparison between Bare Surface and Grass plot- (성층토양의 건조기구에 관한 연구)

  • 김철기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.1
    • /
    • pp.2913-2924
    • /
    • 1973
  • This study was to investigate the drying mechanism of stratified soil by investigating 'effects of the upper soil on moisture loss of the lower soil and vice versa' and at the same time by examining how the drying progressed in the stratified soils with bare surface and with vegetated surface respectively. There were six plots of the stratified soils with bare surface($A_1- A_6$ plot) and the same other six plots($B_1- B_5$ plot), with vegetated surface(white clover). These six plots were made by permutating two kinds of soils from three kinds of soils; clay loam(CL). Sandy loam(SL). Sand(s). Each layer was leveled by saturating sufficient water. Depth of each plot was 40cm by making each layer 20cm deep and its area. $90{\times}90(cm^2)$. The cell was put at the point of the central and mid-depth of the each layer in the each plot in order to measure the soil moisture by using OHMMETER. soil moisture tester, and movement of soil water from out sides was cut off by putting the vinyl on the four sides. The results obtained were as follow; 1. Drying progressed from the surface layer to the lower layer regardless of plots. There was a tendency thet drying of the upper soil was faster than that of the lower soil and drying of the plot with vegetated surface was also faster than that of the plot with bare surface. 2. Soil moisture was recovered at approximately the field capacity or moisture equivalent by infiltration in the course of drying, when there was a rainfall. 3. Effects of soil texture of the lower soil on dryness of the upper soil in the stratified soil were explained as follows; a) When the lower soil was S and the upper, CL or SL, dryness of the upper soils overlying the lower soil of S was much faster than that overlying the lower soil of SL or CL, because sandy soil, having the small field capacity value and playing a part of the layer cutting off to some extent capillary water supply. Drying of SL was remarkably faster than that of CL in the upper soil. b) When the lower soil was SL and the upper S or CL, drying of the upper soil was the slowest because of the lower SL, having a comparatively large field capacity value. Drying of CL tended to be faster than that of S in the upper soil. c) When the lower soil was CL and the upper S or SL, drying of the upper soil was relatively fast because of the lower CL, having the largest field capacity value but the slowest capillary conductivity. Drying of SL tended to be faster than that of S in the upper soil. 4. According to a change in soil moisture content of the upper soil and the lower soil during a day there was a tendency that soil moisture contents of CL and SL in the upper soil were decreased to its minimum value but that of S increased to its maximum value, during 3 hours between 12.00 and 15.00. There was another tendency that soil moisture contents of CL, SL and S in the lower soil were all slightly decreased by temperature rising and those in a cloudy day were smaller than those in a clear day. 5. The ratio of the accumulated soil moisture consumption to the accumulated guage evaporation in the plot with vegetated surface was generally larger than that in the plot with bare surface. The ratio tended to decrease in the course of time, and also there was a tendency that it mainly depended on the texture of the upper soil at the first period and the texture of the lower soil at the last period. 6. A change in the ratio of the accumulated soil moisture consumption was larger in the lower soil of SL than in the lower soil of S. when the upper soil was CL and the lower, SL and S. The ratio showed the biggest figure among any other plots, and the ratio in the lower soil plot of CL indicated sligtly bigger than that in the lower soil plot of S, when the upper soil was SL and the lower, CL and S. The ratio showed less figure than that of two cases above mentioned, when the upper soil was S and the lower CL and SL and that in the lower soil plot of CL indicated a less ratio than that in the lower soil plot of SL. As a result of this experiments, the various soil layers wero arranged in the following order with regard to the ratio of the accumulated soil moisture consumption: SL/CL>SL/S>CL/SL>CL/S$\fallingdotseq$S/SL>S/CL.

  • PDF

Estimation of Runoff Curve Number using Antecedent Runoff Condition (Bangrim and Sanganmi Basin) (선행유출조건(ARC) 방법을 통한 유출곡선지수의 산정(방림, 상안미 유역))

  • Yang, Jae-Mo;Park, Cheong-Hoon;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.288-288
    • /
    • 2011
  • 최근 들어 관측된 강우-유출 사상으로부터 유출곡선지수(Runoff curve number, CN)를 계산하는 연구가 수행되어왔으며, 이것은 기존 선행토양함수조건(Antecedent Moisture Condition; AMC) 을 이용한 유출곡선지수 적용에 대한 여러 문제점(AMC 기준의 타당성, 초기손실우량과 최대잠재보유수량의 비($I_a$ S=0.20의 적정성))이 부각되면서 선행유출조건을 이용한 유출곡선지수가 제안되었다. 본 연구에서는 선행유출조건(Antecedent Runoff Condition, ARC) 방법을 적용하여 IHP유역인 방림과 상안미 유역의 강우-유출자료로부터 CN을 직접 산정하였다. 먼저 방림과 상안미 유역에서 각각 12개, 10개의 관측된 강우-유출 사상을 통해 초기손실우량과 최대잠재보유수량의 비($I_a$/S)가 기존 가정의 0.20보다 작은 것을 확인하고 수정된 $I_a$/S비를 고려하여 대상 유역에서의 적정 CN을 산정하였다. 실제 강우-유출 사상에서 산정한 각 사상별 CN의 대표값을 찾기 위해 ARC-II의 평균유출조건으로 가정하여 각 사상별 단순평균과 4개의 지속기간(4시간, 3시간, 2시간, 1시간)별로 구분하여 평균한 CN을 구분하였다. 이를 통해 계산된 유효우량과 관측 유효우량과 비교를 실시하였으며 각 사상을 단순 평균한 ARC-II 조건으로 가정하여 계산된 CN의 오차가 가장 작은 것으로 나타났다. 따라서 기존의 선행토양함수조건(Antecedent soil moisture condition, AMC)의 CN으로 산정된 유효우량과 ARC조건으로 산정된 유효우량을 비교한 결과 방림유역에서 는 오차가 ARC 방법의 경우 37.76%, AMC 방법의 경우 51.27%로 평가되었고 상안미 유역에서는 오차가 ARC의 경우 31.97%, AMC 방법의 경우43.08%로 두 유역에서 모두 ARC 방법으로 산정된 CN이 더 적은 오차값을 주었다. 따라서 방림과 상안미 유역에서의 ARC로 산정된 CN값은 유효우량 산정의 정확성을 향상시킬 수 있으리라 판단된다.

  • PDF

Prediction of Pull-Out Force of Steel Pegs Using the Relationship Between Degree of Compaction and Hardness of Soil Conditioned on Water Content (함수비에 따른 토양의 다짐도와 경도의 관계를 이용한 철항의 인발저항력 예측 연구)

  • Choi, In-Hyeok;Heo, Gi-Seok;Lee, Jin-Young;Kwak, Dong-Youp
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.23-35
    • /
    • 2023
  • The Ministry of Agriculture, Food and Rural Affairs has announced design standards for disaster-resilient greenhouses capable of resisting wind speeds with a 30-year frequency to respond to the destruction of greenhouses caused by strong winds. However, many greenhouses are still being maintained or newly installed as conventional standard facilities for the supply type. In these supply-type greenhouses, a small pile called a steel peg is used as reinforcement to resist wind-induced damage. The wind resistance of steel pegs varies depending on the soil environment and installation method. In this study, a correlation analysis was performed between the wind resistance of steel pegs installed in loam and sandy loam, using a soil hardness meter. To estimate the pull-out force of steel pegs based on soil water content and compaction, soil compaction tests and laboratory soil box and field tests were performed. The soil compaction degree was measured using a soil hardness meter that could easily confirm soil compaction. This was used to analyze the correlation between the soil compaction degree in the tests. In addition, a correlation analysis was performed between the pull-out force of steel pegs in the soil box and field. The findings of this study will be useful in predicting the pull-out force of steel pegs based on the method of steel peg installation and environmental changes.

A Study on Characteristics of Hydraulic Conductivity in the Soil-Bentonite Mixed Soils with Compaction Energy and Swelling in the Landfill (폐기물매립장에서 다짐에너지와 팽윤도에 의한 토양-벤토나이트 혼합토의 투수계수 특성에 관한 연구)

  • 이종민;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.61-72
    • /
    • 2001
  • A barrier liner system is placed at the bottom and side slope in landfill to protect a leaking of leachate that the hydraulic conductivity of this system should be less than It 107cm/sec. In this study, the soil-bentonite mixture for the bottom liner system was evaluated in two point of views : changing characteristics of the hydraulic conductivity according to the different mixing ratio of soil-bentonite with the effect of bentonite swelling and the difference method (A & D type) of compaction on the hydraulic conductivity. As the results, maximum dry density (${\gamma}$$_{dmax}$) of SC group mixture was higher than of CL group mixture. However, the result of optimum moisture contents(OMC) of both groups were the contrary. In case of ${\gamma}$$_{dmax}$ by different compaction method, D type was higher than A. But the OMC were the contrary. The difference of ${\gamma}$$_{dmax}$ according to the Compaction energy, “SC” group mixture W3S higher than the “CL” group. In case of OMC of “CL” group was higher than “SC” group. The effecting of swelling was a little bit different on the two factors. According to the result of compaction test, the use of site soil only could not meet the criteria on hydraulic conductivity, but could find a solution for the mixing ratio of bentonite mixture were satisfied to the standard of barriation. The increased in bentonite mixing ratio and degree of swelling, the values of hydraulic conductivity were decreased. Especially the “CL” group with “D” type compaction measured the lowest value with the same conditions. Also, the bentonite mixing ratio has more influenced on the hydraulic conductivity compare with swelling effect. The “SC” group mixture with “A” typo compaction got a big difference from others. The evaluation of economic for the construction cost on the two cases, the lower bentonite mixing ratio of soil-bentonite mixed soil is more economically because of bentonite cost.

  • PDF

Experimental Study on Temperature-Moisture Combined Measurement System for Slope Failure Monitoring (사면붕괴 모니터링에 사용되는 온도-함수비 복합계측시스템 개발에 관한 실험적 연구)

  • Nam, Jin-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • Recently, the event of slope failure has been occurring frequently due to rapid climate changes and broad development of infrastructures, and the research for establishment of monitoring and prevention system has been an attentive issue. The major influence factors of slope failure mechanism can be considered moisture and temperature in soil, and the slope failure can be monitored and predicted through the trend of moisture-temperature change. Therefore, the combined sensing technology for the continuous measurement of moisture-temperature with different soil depths is needed for the slope monitoring system. The various independent sensors for each item (i.e. temperature and moisture respectively) have been developed, however, the research for development of combined sensing system has been hardly carried out. In this study, the high-fidelity sensor combing temperature-moisture measurement by using the minimized current consuming temperature circuit and the microwave emission moisture sensor is developed and applied on the slope failure monitoring system. The feasibility of developed monitoring system is verified by various experimental approaches such as standard performance test, mockup test and long-term field test. As a result, the developed temperature-moisture combined measurement system is verified to be measuring and monitoring the temperature and moisture in soil accurately.

Seasonal Variations of Soil CO2 Efflux Rates and Soil Environmental Factors in Pinus densiflora and Quercus variabilis Stands (소나무와 굴참나무 임분의 토양 환경요인과 토양 이산화탄소 방출의 계절적 변화)

  • Baek, Gyeongwon;Jo, Chang Gyu;Kim, Choonsig
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.3
    • /
    • pp.120-126
    • /
    • 2016
  • This study was carried out to examine the relationships between seasonal variations of soil $CO_2$ efflux rates and soil environmental factors in matured Pinus densiflora and Quercus variabilis stands in the Wola national experimental forests, southern Korea. Soil $CO_2$ efflux rates were measured monthly from March 2015 to February 2016. Mean soil $CO_2$ efflux rates during the study period were significantly higher in the Q. variabilis ($mean{\pm}standard$ error; $2.27{\pm}0.22{\mu}mol\;m^{-2}s^{-1}$) than in the P. densiflora ($1.63{\pm}0.12{\mu}mol\;m^{-2}s^{-1}$) stands. Mean soil water content and pH were also significantly higher in the Q. variabilis ($26.96{\pm}0.93%$, pH 5.19) than in the P. densiflora ($21.32{\pm}0.89%$, pH 4.87) stands, while soil temperature was not significantly different between the P. densiflora ($13.92{\pm}0.67^{\circ}C$) and in the Q. variabilis ($13.52{\pm}0.70^{\circ}C$) stands. $Q_{10}$ values were higher in the Q. variabilis (3.35) than in the P. densiflora (2.72) stands. The results indicate that soil $CO_2$ efflux rates in Q. variabilis stand could be more sensitive by the change of soil temperature compared with P. densiflora stand under a similar site environmental condition.

Heavy Metal Contamination in Soils and Groundwater in the Vicinity of the Sindae-dong Waste Disposal Site, Taejon (대전시 신대동 폐기물매립지 주변지역에서의 지하수 및 토양의 중금속오염)

  • 김경웅;손호웅
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.2
    • /
    • pp.85-89
    • /
    • 1994
  • Groundwater and soil contamination by the leak of leachates from the waste disposal site (WDS) is one of the serious environmental problems, and leachates are generally produced by the biogeochmical decomposition and/or precipitation in the WDS. At the Sindae-dong waste disposal site in Taejon, the average Cu, Pb and Zn concentrations in the surrounding soils are higher than those in other Korean soils but these are not high enough to cause any harmful effect to man through the crop plants. Copper, Pb and Zn are not detected in the groundwater samples but the pH of the sample is 5.6 which is not suitable for the drinking water. In contaminated soil samples, the heavy metal concentrations are higher in subsurface soil than in surface soil and it may be influenced by the leachates in groundwater. With the electric resistivity method, the water contains layers are found in contaminated soils and the resistivity values are considerably low because of the dispersion of plume by the leak of leachates. According to the distance from the leak point of leachate, resistivity values increased and heavy metal concentraions in soils decreased due to the reduction of plume.

  • PDF

A study on the number of days without precipitation in the rainfall simulation test for estimating the CN of the permeable pavement (투수포장체 CN 산정을 위한 강우모사 시험의 선행 무강우일수 방안 연구)

  • Park Byeong-Woo;Kang Du-Kee;Park Jae-Rock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.353-353
    • /
    • 2023
  • 기후변화에 대응하는 도시유출 저감과 열섬효과를 방지하기 위해 투수블럭 시공이 증가 추세 있으나, 투수블럭과 하부 도로포장체에 대한 강우모사 시험시 토양함수율 설정기준을 정립할 필요가 있다. 유역 혹은 시험체의 유출량 예측에는 토지 이용에 따라 미국자연자원보호청(Natural Resources Conservation Service, NRCS)의 SCS 유효우량 산정 방법을 통해 CN을 활용할 수 있으며, 이때 유역 혹은 시험체의 선행강우일수에 따라 유출량 결과가 큰 차이가 발생한다. 연구를 위해 시험실이 위치하고 있는 부산시와 양산시 무강우 일수(10년, 2012~2021)를 홍수기, 비홍수기 각각 분석한 결과에 따라, 투수블록 포장체의 CN 산정을 위해 자연강우 이후 시험시 AMC조건을 따르며, 무강우일수 5일 이내에는 비성수기 12.7~27.94mm, 성수기 35.56~53.34mm의 평균강우 20.32mm, 44.45mm에 해당하는 체적의 실험수를 사전에 살수한 후 강우모의시험을 진행한다. 사전살수를 통해 하부기층 토양을 AMC-II 기준에 맞추고, 강우모의 시험을 통해 CN(II) 산정한다. 동일기준에서 진행된 시험 결과, 일정한 유출을 확인하였으며, 적용에 일관성을 유지할 수 있었다. 따라서 토양종류와 토양함수조건에 의거 투수블록 포장 시험체의 CN을 산정을 통해, 도시홍수 유출모형에 적용할 수 있다. 53.34mm 이상의 자연강우시 모니터링을 통한 CN(III)을 산정하여CN(II)로 환산하여 경제적이고 합리적인 유출량을 산정한다.

  • PDF