• Title/Summary/Keyword: 테이프

Search Result 553, Processing Time 0.032 seconds

Adhesion Properties of UV-curable Pressure Sensitive Adhesives for Dicing Tape (다이싱 테이프용 자외선 경화형 점착제의 접착 물성)

  • Do, Hyun-Sung;Kim, Sung-Eun;Kim, Hyun-Joong
    • Journal of Adhesion and Interface
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 2004
  • UV-curable pressure sensitive adhesives were prepared by blending acrylic copolymer, copolymerized with butyl acrylate, acrylic acid and methyl methacrylate by solution polymerization, and trimethylolpropane triacrylate. The PSAs were evaluated by adhesion strength with varying UV dose, and also glass transition temperature ($T_g$) of PSAs were measured. When exposed on UV irradiation, the PSAs showed the decreased adhesion strength and increased $T_g$. And following UV irradiation, the PSAs did not leave any residue on wafer after peel off PSA.

  • PDF

Study of Dispersibility and Dielectric Properties in $SrTiO_3$/COP Composites as the kind/content of Dispersants (분산제의 종류와 함량에 따른 $SrTiO_3$/사이클로올레핀폴리머 복합재료의 분산성 및 유전특성에 대한 연구)

  • Kim, Jun-Young;Lee, Jin-Won;Yoo, Myong-Jae;Lee, Woo-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.261-262
    • /
    • 2008
  • 분산제의 종류와 함량이 무기물-유기물 복합재료의 레올로지 특성 및 유전특성에 미치는 영향에 대하여 고찰하였다. 먼저 Multiple light scattering 방법을 통하여 용액의 입자 이동속도와 용액의 맑은층의 두께변화를 살펴보았으며 이를 통해 적정한 분산제의 선정 및 선정된 분산제의 함량비에 따른 무기물 분말의 분산 특성을 고찰하였다. 그리고 테이프 캐스팅을 통하여 테이프를 제작한 후 1GHz에서 유전특성을 측정하였다. 위 결과들을 통하여 분산제의 종류와 함량비에 따라 용액 및 슬러리의 특성이 다르며 적정한 분산제를 사용하여 유전상수 16.5에 유전손실 0.0058의 복합재료를 제작할 수 있었다.

  • PDF

Design and Implementation of a Volume Structure for Tertiary Storage Devices in MIDAS-II (MIDAS-II에서 3차 저장 장치를 위한 볼륨 구조의 설계 및 구현)

  • Kim, Yeong-Seong;Gang, Hyeon-Cheol;Kim, Myeong-Jun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.5 no.6
    • /
    • pp.674-685
    • /
    • 1999
  • MIDAS-II는 한국전자통신연구원에서 개발한 바다 DBMS의 저장 시스템이다. MIDAS-II 볼륨은 데이터의 논리적 저장 단위인 파일을 저장하는 영역을 가리킨다. 본 논문에서는, MIDAS-II가 대용량 멀티미디어 데이터 서버의 저장 시스템으로 기능하도록 광 디스크 쥬크박스 또는 테이프 라이브러리와 같이 복수 개의 저장 매체 (platter , 예를 들어 디스크 또는 카트리지 테이프)로 구성된 Tera 바이트 급의 3창 저장 장치를 장착할 경우 이를 위한 볼륨 구조의 설계 및 구현에 대해 기술한다. 본 논문에서 제안하는 볼륨 구조는 3차 저장 장치 접근 시 성능 제고를 위하여 디스크 캐쉬 영역을 두고 있으며, 3차 저장 장치의 저장 매체별 관리 기능을 제공한다. Abstract MIDAS-II is the storage systemfor BADA DBMS developed at ETRI. A volume of MIDAS-II is the area where the files, the logical unit for storing data, are stored. This paaper describes the design and implementation of a new MIDAS-II volume structure for the tertiary storage device such as an optical disk juke box or a tape library equipped with multiple platters(disks or cartridge tapes, for example ). Incorporating thetertirary storage device of the order of tera bytes into MIDAS-II enables it to function as a storage system for a massive amount fo multimedia eata server. The volume structure for the tertiary storage device proposed in this paper features disk caching for performing improvement and direct control of theindividual platter.

Improvement of patient's quality of life by improving patient's set-up line in radiotherapy (방사선 치료 시 환자 Set-up Line 개선을 통한 암환자 삶의 질 만족도 향상)

  • Choi, Jin Hyuk;Ahn, Woo Sang;Lee, Woo Seok;Kim, Dae Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.185-189
    • /
    • 2018
  • Purpose : We evaluated the quality of life satisfaction of patients with radiation therapy while maintaining the set-up line. Materials and Methods : We retrospectively reviewed 60 patients who visited our clinic in January, 2018. The most common complaint was the inconvenience of not being able to wash during treatment (64 %), and a surgical tape was placed on the Set-up Line to help patients wash during the treatment period. A total of 50 patients who underwent surgical tape were evaluated on a 5-point scale (1 point was very unsatisfactory, 2 points were unsatisfactory, 3 points were average, 4 points were satisfied, 5 points were very satisfied). Forty patients out of 50 responded to the first treatment, and 10 patients underwent treatment. Results : In the first survey, 68 % of the patients and 32 % of the males were aged 34 %, 50~60 % and 38 %, respectively. Treatment areas were breast (57 %), chest (13 %), pelvis (10 %). The results of the second questionnaire after applying the surgical tape showed that 25 of the 40 patients and 15 of the male patients were treated. The treatment area was 22 breast and 18 pelvic areas. In the satisfaction of the 5-point scale, 5 to 15 points were satisfied with 1-3 points, and 4-5 points with 35 points (1 point 2 points, 2 points 2 points, 3 point 1 points, 4 point points 17 point points, % And 43 %, respectively. The results of the questionnaire survey of patients who were applied during the treatment showed that 9 out of 10 women and 1 male were treated. The treatment area was 8 breast and 2 pelvic areas. One point was satisfied with one point, and five points with nine points were satisfied with 90 %. Conclusions : The importance of improving the quality of life of patients with cancer is also important. After applying the surgical tape, 88 % of the patients who started the treatment and 90 % of the patients who applied during the treatment were satisfied. Particularly, patients who applied during treatment showed higher satisfaction. If this is not possible for all patients, selective application to patients with discomfort will be helpful in improving the quality of life of cancer patients.

  • PDF

Characteristic Validation of High-damping Printed Circuit Board Using Viscoelastic Adhesive Tape (점탄성 테이프를 적용한 고댐핑 적층형 전자기판의 기본 특성 검증)

  • Shin, Seok-Jin;Jeon, Su-Hyeon;Kang, Soo-Jin;Park, Sung-Woo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.383-390
    • /
    • 2020
  • Wedge locks have been widely used for spaceborne electronics for mounting or removal of a printed circuit board (PCB) during integration, test and maintenance process. However, it can basically provide a mechanical constraint on the edge of the board. Thus, securing a fatigue life of solder joint for electronic package by limiting board deflection becomes difficult as the board size increases. Previously, additional stiffeners have been applied to reduce the board deflection, but the mass and volume increases of electronics are unavoidable. To overcome the aforementioned limitation, we proposed an application of multi-layered PCB sheet with viscoelastic adhesive tapes to implement high-damping capability on the board. Thus, it is more advantageous in securing the fatigue life of package under launch environment compared with the previous approach. The basic characteristics of the PCB with the multi-layered sheet was investigated through free-vibration tests at various temperatures. The effectiveness of the proposed design was validated through launch vibration test at qualification level and fatigue life prediction of electronic package based on the test results.

The Preparation of Bi-2223 Superconducting Powder and Tape by Emulsion Drying Method (에멀젼 건조법에 의한 Bi-2223 초전도 분말과 테이프 제조)

  • 장중철;이응상;이희균;홍계원
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • The powder preparation by using emulsion drying method, one of the chemical powder fabrication methods has the advantages; easy to control the chemical stoichiometry and to fabricate homogeneously fine particles. In the present study, the initial morphology and size distribution of the powder fabricated by using emulsion dry-ing method were controlled and were improved the homogeneity. By carefully controlling the mixing ratio of oil phase and aqueous solution and surfactant of preventing emulsion separation, the Bi(Pb)-Sr-Ca-Cu-O su-perconducting powders were prepared. The properties of the superconducting powder fabricated by this method and the microstructures and superconducting properties of the pelletized samples were investigated. The microstructures and electric properties of the tapes prepared by oxide powder-in-tube method were in-vestigated. The fabricated powder was spherical with less than 1$\mu$m but most of them was agglomerated with 2~5$\mu$m in size. The critical temperature of the pelletized sample annealed at 84$0^{\circ}C$ for 72 hours in oxygen par-tial pressure of 1/13atm in Ar atmosphere was 108K. And the critical current of the first and second annealed tapes in air prepared by oxide powder-in-tube process were 0.4A and 1.5A, respectively.

  • PDF

The Effect of Physical and Chemical Stimuli on Ophthalmic Lens Coatings (물리적, 화학적 자극이 안경 렌즈의 코팅에 미치는 영향)

  • Kim, So Ra;Kim, Ji Yoon;Kim, Ka Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.237-245
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether certain repeated physical and/or chemical stimuli added on ophthalmic lenses might induce any changes of the functions of lens coatings. Methods: The changes in lens surface, light transmittance, foggy duration, durability of ophthalmic lenses were determined after the application of tearing-off with tape, rubbing with acetone, soaking in acetone or distilled water of ophthalmic lens (CR-39 material) as physical and/or chemical stimuli. Results: The change of ophthalmic lens surface was detected after soaking in acetone for longer than 30 minutes by observing the lens surface to figure out the functional change of hard coating. The ophthalmic lens soaked in distilled water for 180 minutes showed little functional change of anti-reflection coating as 1% by measuring light transmittance of lens. However, the function of anti-reflection coating was almost disappeared after the ophthalmic lens was soaked in acetone for 60 minutes. The foggy duration of ophthalmic lens soaked in acetone was increased by estimating foggy duration of lens. The lens coating was shown to be defected when the pre-damaged ophthalmic lenses were torn off with tape, rubbed with acetone and soaked in distilled water or acetone by observing pre-damaged lens surface to evaluate its durability. Conclusions: The careful management during ophthalmic lens dispensing or usual eyeglass wearing is needed since the change in ophthalmic lens coatings was shown by repeated physical and/or chemical stimuli.

Effect of Silane Coupling Agent on Adhesion Properties between Hydrophobic UV-curable Urethane Acrylate and Acrylic PSA (소수성 UV 경화형 우레탄 아크릴레이트와 아크릴 점착제 사이의 계면 부착력 향상을 위한 에폭시 실란의 영향)

  • Noh, Jieun;Byeon, Minseon;Cho, Tae Yeun;Ham, Dong Seok;Cho, Seong-Keun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.230-236
    • /
    • 2020
  • In this study, an adhesive tape with water and impact resistance for mobile devices was developed using a UV-curable urethane acrylate based polymer as a substrate. The substrate fabricated by UV-curable materials shows hydrophobicity and poor wettability, which significantly deteriorates the interface-adhesions between the substrate and acrylic adhesive. In order to improve the interface adhesion, 3-glycidoxy-propyl trimethoxysilane (GPTMS), a silane coupling agent having epoxy functional groups, was selected and incorporated into UV-curable urethane acrylate based polymer resins in various contents. The changes of the chemical composition according to the contents of GPTMS was studied with Fourier-transform infrared spectroscopy (FT-IR), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) to know the surface bonding properties. Also mechanical properties of the substrate were characterized by tensile strength, gel fraction and water contact angle measurements. The peel strengths at 180° and 90° were measured to compare the adhesion between the substrate and adhesive according to the silane coupling agent contents. The mechanical strength of the urethane acrylate adhesive tape decreased as the silane coupling agent increased, but the adhesion between the substrate and adhesives increased remarkably at an appropriate content of 0.5~1 wt%.

Basic Characteristic Verification of High-damping Laminated Solar Panel with Viscoelastic Adhesive Tape for 6U CubeSat Applications (점탄성 테이프를 적용한 6U 큐브위성용 고댐핑 적층형 태양전지판의 기본 특성 검증)

  • Kim, Su-Hyeon;Kim, Hongrae;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.1
    • /
    • pp.86-94
    • /
    • 2021
  • PCB-based deployable solar panel is mainly used for CubeSat due to its lightweight and easy of electrical connection. However, as the size of solar panel increases, there is a limit to ensuring the structural safety of solar cells due to excessive dynamic displacement under launch vibration environment. In previous mechanical designs, for the minimization of dynamic deflection, panel stiffness is increased by applying additional stiffeners made of various materials such as aluminum or composite. However, it could have disadvantages for CubeSat design requirements due to limited mass and volumes. In this study, a high-damping 6U solar panel was proposed. It had superior damping characteristic with a multi-layered stiffener laminated with viscoelastic acrylic tapes. Basic characteristics of this solar panel were measured through free-vibration tests. Design effectiveness of the solar panel was validated through qualification-level launch vibration test. Based on test results, vibration characteristics of a typical PCB solar panel and the high-damping laminated solar panel were predicted and a comparative analysis was performed.

The Effect on Drooling of Applying Kinesiology Tape to the Orbicularis Oris Muscle in Children with Cerebral Palsy: A Case Study (입 둘레근에 키네시올로지 테이프 적용이 뇌성마비 아동의 침흘림에 미치는 영향: 단일대상연구)

  • Jeon, Joo young;Seo, Sang Min
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.21 no.1
    • /
    • pp.11-22
    • /
    • 2023
  • Objective : The purpose of this study was to examine the effects of using Kinesiology Tape (KT) for drooling in children with cerebral palsy. Methods : A single-case experimental design with an ABA design was conducted. A total of 46 sessions were conducted, consisting of three baseline sessions (A), 40 intervention sessions (B), and three baseline sessions (A'). The Drooling Impact Scale (DIS) and the Interlabial Gap (IG) were measured before and after the KT intervention, and a Goal Attainment Scale (GAS) was assessed to determine whether there was any change in the target activity for each session. The KT intervention was attached to the orbicularis oris muscle. The KT intervention time was set as the time taken for dysphagia intervention and the actual meal time, for up to one hour a day, for a total of eight weeks. Results : The results of the study showed that the KT intervention had an effect on both the DIS and the IG, and that the GAS scale indicated that target activity increased with each session. Conclusion : These results indicate that the KT intervention can easily be applied to children with cerebral palsy who suffer from drooling, whether in clinical practice, by therapists, or caregivers, and that it can be used for various purposes.