• Title/Summary/Keyword: 터빈-발전기

Search Result 320, Processing Time 0.025 seconds

Conceptual Design of 100 MW Turbogenerator (가스터빈 구동 공냉식 100 MW 발전기의 개념설계)

  • Park, Doh-Young;Hwang, Don-Ha;Ha, Kyung-Duck;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.88-90
    • /
    • 1998
  • The conceptual design of turbine-driven air-cooled 100 MW generator is presented. The generators rating is 100 MW 3-phase 2pole 13.8 kV 0.85 pf 60 Hz. The conceptual design is described by the process of designing the stator, rotor, and obtaining some of equivalent circuit parameters. The design process starts from the output coefficient G, and utilizes the classical design equations with parameters used in the modern designs. The slot dimensions of the stator and rotor are obtained with their respective winding dimensions.

  • PDF

Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator (대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성)

  • Kim, Hee-Dong;Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

Development of 100 Kw Power Class Airborne Auxiliary Power Unit (100 Kw급 항공용 보조동력장치(APU) 개발)

  • Yang, Soo-Seok;Lee, Dae-Sung;Kim, Seung-Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.291-300
    • /
    • 1999
  • Currently under development is an airborne auxiliary power unit with 100 Kw equivalent power, which is composed of a centrifugal compressor, a reverse annular combustor, and a radial turbine. Air-foil bearings are used in this power unit to eliminate the oil supplying system, which can reduce the system complexity and weight. The high speed generator is adopted as an electric power generation and engine starting system, which can also eliminate the reduction gear system. Not only electric power but also pneumatic power is provided by bleeding the compressed air This power unit is aimed for the multi-purpose use such as a primary power unit In the army weapon system, an auxiliary power and environmental control unit in a next-generation tank, and a smoke generating unit.

  • PDF

Load Calculation of a 750 kW Direct-drive Wind Turbine Generator System (750kW급 직접구동형 풍력발전기의 부하계산)

  • Sohn, Y.U.;Park, I.S.;Kwon, S.J.;Kim, Y.C.;Son, J.B.;Kim, K.R.;Chung, C.W.;Chun, J.H.;Ryu, J.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.649-655
    • /
    • 2003
  • Load calculation is indispensable for the construction of a large wind turbine generator system (WTGS). In procedures of load calculation, all conditions affecting to WTGS such as environment of site, operation, transport and installation have to be considered systematically. So the certification of WTGS is issued by assuring the load calculation. This work shows the generals of load calculation briefly and introduces the characteristics and results of load calculations for the 750 kW direct-drive WTGS (KBP-750D) which is under development by the consortium of POSTECH and UNISON.

  • PDF

A Study on Effect of Exciter Parameters for the Torsional Stress of Turbine-Generator (여자시스템의 파라미터가 터빈-발전기의 비틀림 스트레스에 미치는 영향 분석)

  • 김찬기
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.420-426
    • /
    • 2003
  • This paper deals with the effect of exciter parameters on the torsional stress of turbine-generator. The excitation system effects on the AC network stability and the turbine-generator stress. However. it, until now, have not reported that any parameter among exciter parameters is related to the stability and the stress. In order to verify those CIGRE HVDC model was used. Since the AC network with HVDC has the voltage stability problem due to big capacitor, the worst condition to analyze the stress can considered. The EMTDC program is used for the simulation studies.

Assessment of Insulation Condition in Operating Large Turbine Generator (운전중인 대형 터빈발전기에서 절연상태 평가)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.324-329
    • /
    • 2004
  • Six stator slot couplers(SSC) and a flux probe sensor installed on the stator winding slots of large turbine generator. Assessment of insulation condition has been based upon the measurements of partial discharge(PD) of stator windings and shorted-turn of rotor windings in operating large turbine generator. The maximum PD magnitude(Qm), normalized quantify number(NQN), PD pattern and shorted-turn were measured using on-line insulation condition monitoring system. The NQN and Qm of slot PD side in the phase A are indicated the highest value in six SSC sensors. Monitoring system results showed that discharge at conductor surface and internal discharge were detected at the surface of stator winding and in voids of the groundwall insulation. Insulation of stator and rotor windings in large turbine generator was judged to be in good condition.

A Study on the Gain Scheduling Speed Controller of Permanent Magnet Synchronous Generators for MW-Class Direct-Driven Wind Turbine Systems (MW급 직접구동형 풍력터빈시스템을 위한 영구자석 동기발전기의 게인 스케쥴링 속도제어기에 대한 연구)

  • Choi, Young-Sik;Yu, Dong-Young;Choi, Han-Ho;Jung, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.48-59
    • /
    • 2011
  • This paper presents a new gain scheduling speed controller of permanent magnet synchronous generators(PMSG) for MW-class direct-driven wind turbine systems. The proposed gain scheduling speed controller performs the speed tracking at more than one operating point, and the first-order torque observer estimates the turbine torque which is needed to precisely control the speed of PMSG. The proposed speed controller verifies that the PMSG can successfully follow the reference speed which is determined via the maximum power point tracking(MPPT) control and pitch control under turbulent wind conditions. The proposed speed control algorithm is simulated using Simulink and its performance is confirmed through comparison with the results by PI control method.

A simulation test of lone rejection for steam turbine generator in nuclear power plant (원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Tae-Woon;Lee, Ki-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2301-2303
    • /
    • 2003
  • A steam turnine in thermal/nuclear power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy. After synchronization in parallel with the power system, generator output increases according as the governor, that is the controller, increases steam flow into turbine. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip setpoint by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a simulation test of generator load rejection to be implemented on the turbine governor in a 600MW nuclear power plant before its startup.

  • PDF

Thermal cycle test for water-cooled stator bar (수냉각 고정자 권선용 바의 열 사이클 시험)

  • Kim, Tae-Hee;Oh, Se-Wook;Lee, Jai-Kwun;Son, Sam-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1722-1725
    • /
    • 2003
  • 절연물에 가해지는 열화 중에서 열 사이클(Thermal cycle) 열화를 모사하기 위하여, 대형 터빈 발전기 수냉각 고정자 권선용 바를 대상으로 IEEE Std 1310 규격에 따라 200 사이클의 열 사이클 열화 시험을 수행하였다. 바에 대한 절연 특성을 분석하기 위하여 시험 수행 전후의 Tan ${\delta}$ 및 Tip-up(%, ${\Delta}$ Tan ${\delta}$), 부분방전의 최대 방전량 등을 측정하였고 또한 바를 절단하여 절연물 내의 박리와 도체와 절연물 간의 분리 등을 점검하였다. 최종적으로는 절연파괴 시험을 수행하여 절연파괴 강도를 측정하였다. 시험 결과 초기 절연 특성상의 현저한 변화는 없었으며 양호한 특성을 보였다.

  • PDF

Starting Characteristics of Darrieus Wind Turbine (다리우스 풍력터빈 발전기의 기동특성)

  • Lee, Kyu-Yong;Lee, Woo-Suk;Seo, Young-Teak;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1018-1020
    • /
    • 2003
  • Wind-powered generator system converts wind energy into utilized electric energy. Wind power generator is classified into two categories, as horizontal or vertical axis turbine. The former is equipped with yawing mechanism which is subject to set the blade-face towards the wind direction. However, the latter does not need this mechanism, but this system needs a external power for starting. This paper deals with the method how to overcome such trouble and with the analysis of the starting characteristic and a field test with a prototype of the Darrieus wind generator was performed.

  • PDF