• Title/Summary/Keyword: 터빈-발전기

Search Result 319, Processing Time 0.03 seconds

Vibration Analysis of Steam Turbine-Generator Rotor System Using Component Mode Synthesis Method (구분모드합성법을 이용한 증기터빈$\cdot$발전기축계의 진동해석)

  • Yang, B.S.;Kim, Y.H.;Choi, B.G.;Lee, H.
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.401-408
    • /
    • 1999
  • A method is presented for the vibration analysis of steam turbine-generator rotor system based on the component mode synthesis method. The motion of each component of the system is described by superposing constraint mode associated with boundary coordinates and constrained normal modes associated with internal coordinates. This method using real fixed-interface modes allows for significant reduction in system model size while retaining the essential dynamic characteristics of the lower modes. The capability of this method is demonstrated in the natural frequency and unbalance response analysis of the steam turbine-generator rotor system in which the dynamics of the pedestal is considered. The results by the present method are compared with finite element method and trnasfer matrix method in terms of the accuracy and computing time.

  • PDF

Injection of Rotor Current for DFIG-Based Wind Turbine to Improve Transient State under Voltage Dips (DFIG 풍력터빈의 계통 저전압 발생 시 과도상태 개선을 위한 회전자 전류 주입 방법)

  • Kim, Tae-Hyeong;Kim, Soo-Bin;Song, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.465-466
    • /
    • 2019
  • 전 세계적으로 지구 온난화와 화석연료 고갈로 재생 에너지의 수요가 증가하고 있다. 풍력발전은 전체 재생 에너지의 20% 이상을 차지하며, 2020년 까지 792 GW가 설치될 것으로 전망하고 있다. DFIG(이중여자 유도 발전기)타입의 풍력 터빈은 전력변환장치의 용량이 작은 장점이 있지만, 고정자 권선이 계통과 연결되어 계통 저전압 발생 시 제어가 어렵다는 단점이 있다. 본 논문에서는 계통 저전압 발생 시 고정자 회로의 과도상태에 대해 정리하고, 과도상태를 개선하기 위한 회전자 전류 주입 방법 대해 제시하고 시뮬레이션을 통해 검증하였다.

  • PDF

Protection Actions of SPS and SPS in Korea Power System (SPS의 보호동작과 우리나라 계통보호설비 현황)

  • Park, Jong-Young;Park, Jong-Keun;Chu, Jin-Bu;Jang, Byung-Tae;Kang, Gye-Hee;Yang, Jung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.274-276
    • /
    • 2002
  • 긴급보호제어시스템(SPS, Special Protection System)은 일반적인 보호동작 범위를 벗어난 외란에 대해서 계통 전지역의 보호를 목적으로 하는 광역시스템 보호기술이다. 따라서 SPS는 외란 시에 계통 장비의 보호보다는 계통을 보호함으로써 전력 공급능력 향상에 주안점을 두게 된다. SPS는 자주 동작하지 않고 평소에는 대기 상태로 있으며, 긴급한 동작이 요구되기 때문에 많은 경우에 그 동작이 미리 결정되어 있다. SPS는 입력변수나 전력계통에의 영향에 따라 분류할 수 있는데, 입력변수에 따라서는 계통 응답에 기초한 SPS와 사고에 기초한 SPS로 나눌 수 있다. 발전기 탈락, 부하 차단이 SPS의 주요 보호 동작이며 이 외에 가스터빈이나 양수발전기 기동, AGC 제어, HVDC 고속전력변환, 분로기기의 자동스위칭 등의 제어 동작이 있다. 우리나라의 경우에는 주로 동기탈조 방지를 위한 발전기 탈락의 동작을 하는 SPS가 설치, 운전되고 있다.

  • PDF

전력플랜트 건설의 최신기술동향

  • KOREA ELECTRIC ASSOCIATION KOREA ELECTRIC ASSOCIATION
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.310
    • /
    • pp.67-72
    • /
    • 2002
  • 미쓰비시(삼릉)전기 플랜트건설총괄부의 전력플랜트 건설공사는 수력$\cdot$화력플랜트 및 변전설비를 대상으로 하고 있으며, 수차$\cdot$수차발전기$\cdot$가스절연개폐장치(이하 ''GIS''라 한다), 변압기, 배전반 및 관련 제어기기 등의 설치 및 기기간의 배선공사 설계$\cdot$시공을 담당하고 있다. 최근의 전력플랜트를 둘러싼 일본의 시장환경은 신설 플랜트는 감소하고 갱신$\cdot$기기개수(개조, 수선) 공사의 비율이 커지고 있으며, 신설$\cdot$개보수 공사를 불문하고 공사품질의 유지와 공사비 저감을 위한 공법$\cdot$작업의 개선과 설계$\cdot$계획 업무의 합리화를 추진하여 왔다. (1) 기자재 개발에 의한 공법$\cdot$작업 개선 대형수력발전기의 로터조립용 다브테일키 박아놓기(타입)장치, 스테이터코일 분해(갱신)용 코일 엔드절단 및 코일뽑기공구, 터빈발전기 센터링용 유압잭, GIS 설치용 작업용발판을 개발하여 적용함으로써 공법 개선과 작업효율의 향상을 실현하였다. (2) 공사계획 방법의 개선 변전플랜트에서의 공기단축을 목적으로 하는 현지 설치 최적공정 책정방법의 개발$\cdot$적용, 또한 화력플랜트에서의 공사물량의 저감과 설계작업의 효율 향상을 목적으로 하는 케이블 배선 설계$\cdot$계획 방법의 개발 및 적용으로 설계업무의 개선, 공사비 저감을 도모하였다.

  • PDF

Grid-Connected Variable Speed Wind Power Generation System Using Cage-Type Induction Generators (농형 유도발전기를 이용한 계통연계형 가변속 풍력발전시스템)

  • 김형균;이동춘;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.397-404
    • /
    • 2004
  • This paper proposes a variable speed control scheme of grid-connected wind power generation systems using cage-type induction generators. The induction generator is operated in indirect vector control mode, where the d-axis current controls the excitation level and the q-axis current controls the generator torque, by which the speed of the induction generator is controlled according to the variation of the wind speed In order to produce the maximum output power. The generated power flows into the utility grid through the back-to-back PWM converter. The line-side converter controls the dc link voltage by the q-axis current control and can control the line-side power factor by the d-axis current control. Experimental results are shown to verify the validity of the proposed scheme.

Offshore Wind Power, Review (해상풍력(Offshore Wind Power) 기술동향)

  • Nah, Do-Baek;Shin, Hyo-Soon;Nah, Duck-Joo
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.143-153
    • /
    • 2011
  • Offshore wind power(OWP) is one of the most promising renewable energy and gives higher output than onland one due to stronger and consistent wind in offshore. it offsets shortcoming of noise, spatial limit and less affects scenery, and can be built in larger size. Korea has plenty of offshore wind resources as it is surrounded by the sea in three directions. This review describes recent progress in offshore wind turbine and substructure technology. Market trend in local and overseas, Number of papers published and patents registered are analysed.

Study on 4-degree-of-freedom Mathematical Model for Simulation of Wind Turbine System at Initial Design Stage (풍력발전기 초기단계 모사실험을 위한 4자유도 수학적 모형에 대한 연구)

  • Shin, Yun-Ho;Moon, Seok-Jun;Chung, Tae-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.681-689
    • /
    • 2013
  • The commercial tools to simulate the non-linear dynamic characteristics of wind turbine system are various but, the tool take much time to simulate the control algorithm and require many input variables. In this paper, the procedures to derive the simplified 4-degree-of-freedom mathematical model of a 2-MW wind turbine which could be used at the initial design stage of the controller are proposed based on RISO's suggested method. In this model, the 1st tower fore-after bending motion and 1st blade flapping motion are also considered in addition to the rotor-generator rotation motion in the 2-DOF model. The effectiveness of the 4-DOF model is examined comparing with the 2-DOF model and verification of the simplified model is accomplished through modal analysis for whole wind turbine system.

Development of Fuzzy Logic-Based Diagnosis Algorithm for Fault Detection Of Dual-Type Temperature Sensor for Gas Turbine System (가스터빈용 듀얼타입 온도센서의 고장검출을 위한 퍼지로직 기반의 진단 알고리즘 개발)

  • Young-Bok Han;Sung-Ho Kim;Byon-Gon Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.53-62
    • /
    • 2023
  • Due to the recent increase in new and renewable energy, gas turbine generators start and stop every day to supply high-quality power, and accordingly, the life span of high-temperature parts is shortened and the failure of combustion chamber temperature sensors increases. Therefore, in this study, we proposed a fuzzy logic-based failure diagnosis algorithm that can accurately diagnose and systematically detect the failure of the sensor when the dual temperature sensor used for gas turbine control fails, and to confirm the usefulness of the proposed algorithm We tried to confirm the usefulness of the proposed algorithm by performing various simulations under the matlab/simulink environment.

A Study on Design of 50kW PMSG for Micro-grid Application (마이크로그리드용 50kW급 PMSG 설계에 관한 연구)

  • Jeong, Moon-Seon;Moon, Chae-Joo;Kim, Hyoung-Gil;Chang, Young-Hak;Park, Tae-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.4
    • /
    • pp.527-536
    • /
    • 2014
  • In this paper, the 50kW aerogenerator which is applicable to the microgrid was designed and analyzed by using commercial simulation program Maxwell 2D. Particularly, the suggested PMSG to reduce the cogging torque introduced the offset and skew concept. The suggested optimal value of offset and skew was decided by 2mm and 60 degree of electric angle. The simulation results of the PMSG when load operation condition showed the average harmonic distortion 1.3%, voltage 322.41V, current 94.95A, and iron loss 9.73W, eddy current loss 73.68W, copper loss 3.52kW. The capacity of aerogenerator calculated 61.56kW, and the suggested design process can be applied to higher capacity generator.

A Convergency Study on the Gas Turbine Rotation Axis Temperature Sensor for Power Plants (발전소용 가스터빈 회전축 온도 센서 융합연구)

  • Lee, Jeongl-Ick;Na, Gi-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.293-298
    • /
    • 2019
  • The global market for temperature sensors for power plants is estimated at around 35 billion won, of which South Korea relies on imported products for more than 95 percent. This study is that a temperature measurement device for gas turbine rotators for power plants and can be applied to more than 800 of 100 MW gas turbine generators operating in Korea. This study has improved durability by changing the shape of the measuring part, structure of the connecting part, and material changes, and is a component technology applicable to other measuring devices such as humidity, gas and hydraulic pressure used in precision chemical process and plant export industry. As a result of this study, temperature sensors designed as three types of sensors for measuring the temperature of the gas turbine for power plants met Class 1 temperature accuracy in the range of 0℃ to 300℃, and improved durability significantly compared to similar products.