• Title/Summary/Keyword: 탱크변화량

Search Result 73, Processing Time 0.024 seconds

An Experimental Study on the Melting of a Horizontal Cylindrical Ice-Bar Submerged in Water (물속에 水平으로 잠겨 있는 圓 形 얼음 棒 의 融解現象 에 관한 實驗的 硏究)

  • 이동욱;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.414-420
    • /
    • 1985
  • The melting phenomenal of the horizontal cylindrical ice-bar submerged in water are experimentally investigated for the temperature range from 2.5.deg. C to 15.deg. C. The shapes of the melting ice-bar are recorded by the Photo-elasticity Apparatus with modification of the test section. The shadowgraphs of the melting ice-bar show that water adjacent to the bar flows upward for the temperature range from 2.5.deg. C to 5.6.deg. C while above the temperature of 5.6.deg. C the flow is downward direction. The local and average Nusselt numbers become minimum at 5.6.deg. C which is considered as a critical temperature and the Nusselt numbers increase as temperature difference from the critical temperature increase.

Variation of abrasive feed rate with abrasive injection waterjet system process parameters (연마재 투입형 워터젯 시스템의 공정 변수에 따른 연마재 투입량 변화)

  • Joo, Gun-Wook;Oh, Tae-Min;Kim, Hak-Sung;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.141-151
    • /
    • 2015
  • A new rock excavation method using an abrasive injection waterjet system has been developed to enhance the efficiency and reduce the vibration of tunnel excavation. The abrasive feed rate is an important factor for the cutting performance and the economical efficiency of waterjet-based excavation. In this study, various experiments were performed to explore the effects of major process parameters for both the abrasive feed rate and the suction pressure occurring inside the mixing chamber when the abrasives are inhaled. Experimental results reveal that the abrasive feed rate is affected by geometry parameters (abrasive pipe height, length, and tortuosity), abrasive parameters (abrasive particle size), and jet energy parameters (water pressure and water flow rate). In addition, the relation between the cutting performance and the abrasive feed rate was discussed on the basis of the results of an experimental study. The cutting performance can be maximized when the abrasive feed rate is controlled appropriately via careful management of major process parameters.

Optimization of Large Scale Culture Conditions of Bacillus ehimensis YJ-37 Antagonistic to Vegetables Damping-off Fungi (채소류 모잘록병균에 길항하는 Bacillus ehimensis YJ-37의 대량배양 최적조건)

  • 주길재;김진호
    • Journal of Life Science
    • /
    • v.12 no.3
    • /
    • pp.242-249
    • /
    • 2002
  • The optimal culture conditions in 500$m\ell$ flask suture, 5$\ell$ jar fermenter and 2,000 $\ell$ large stale culture were investigated to maximize the production of antibiotic on Rhizoctonia solani AC4, the causal agent of vegetables damping-off, by the strain Bacillus ehimensis YJ-37. Starch (1.5%) as a carbon source, peptone (0.6%) as a nitrogen source and MgC1$_2$(0.15%) as a metal ion in the medium containing N $a_2$HP $O_4$(0.3%) showed the highest production of the antibiotic(s) in a rotary shake (200 rpm). Optimal initial pH of the culture medium, culture temperature and culture time for the antibiotic(s) production were pH 8.0, 32$^{\circ}C$ and 54hrs, respertively. Under the optimal renditions in flask culture, cell growth and antifungal activity (clear zone size) were 1.42 $\times$ 10$^{8}$ cfu/$m\ell$ (21g-DCW/ $\ell$) and 13.9 mm, respectively. In 5 $\ell$ jar fermenter (medium 3 $\ell$), optimal air flow, agitation speed and culture time for the antibiotic(s) production were 2 vvm, 200 rpm and 48hrs, respectively. Under the optimal conditions in 5 $\ell$ jar fermenter, tell growth and antifungal activity were 2.06 $\times$ 10$^{8}$ cfu/$m\ell$ (30g-DCW/ $\ell$) and 13.4 mm, respectively. Under the culture conditions of air flow (30 vvm) and agitation speed (200 rpm) at 32$^{\circ}C$ for 10 days in 2,000 $\ell$ large scale culture (medium 1,800 $\ell$, pH 8.0), cell growth and antifungal activity were 0.81$\times$10$^{8}$ cfu/$m\ell$ (12g-DCW/ $\ell$) and 8.6 mm, respectively.

A Study on the Experimental Measurements and Its Recovery for the Rate of Boil-Off Gas from the Storage Tank of the CO2 Transport Ship (CO2 수송선 저장탱크의 BOG 측정 실험 및 회수에 관한 연구)

  • Park, Jin-Woo;Kim, Dong-Sun;Ko, Min-Su;Cho, Jung-Ho
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • $CO_2$ is generated by the combustion reaction, when getting the energy from fossil fuel. If the carbon dioxide emissions increases more, the global warming problem will become more serious. CCS (carbon capture storage) needs to be developed for the prevention of this. When liquefied $CO_2$ is transported, BOG (boil-off gas) is generated because of several problems. In the study, by injecting liquefied $CO_2$ in two tanks which contains $40m^3$each, the amount of BOG and its composition were measured during 30 days when generating pressure changes and external heat, loading, unloading. In result, 16,040 kg of BOG was generated and the composition has been found out to be 99.95% $CO_2$ and 0.05 % $N_2$. Also, we conducted simulation process for reliquefaction of generated BOG with vapor compression cycle using the PRO/II with PROVISION version 9.2. As a result, the refrigeration cycle of the total circulation flow rate was 42.07 kg/h and the condenser utility consumption was 48.85 kg/h.

Reduction of Stem Inside-cavity and Improvement of Flower Quality in Chrysanthemum 'Baekma' by pH Stabilization and Foliar Spray of Ethephon (양액 pH 안정화와 에세폰 살포에 의한 국화 '백마'의 줄기동공 경감과 절화품질 향상)

  • Hwang, In Taek;Cho, Kyung Chul;Kim, Hee Gon;Ki, Gwang Yeon;Yoon, Bong Ki;Choi, Kyung Ju;Lim, Jin Hee;Choi, Sung Ryul;Shin, Hak Ki
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.4
    • /
    • pp.238-243
    • /
    • 2010
  • This study was conducted to investigate effects of nutrient solution pH control agent and foliar spray of ethephon on the reduction of stem inside-cavity and improvement of flower quality in chrysanthemum 'Baekma'. Changes of pH in nutrient solution as affected by the kind of pH control agent showed more settled pattern in the plot of KOH treatment than in others. Plant growth and development such as cut flower length, leaf numbers, cut flower weight and petal number were the greatest in the plot of KOH. However, the size and area of stem cavity was large in KOH rather than $KHCO_3$. As changes in the absorbing patterns of mineral elements as affected by nutrient solution pH control agent in closed system, contents of total nitrate, phosphorus, potassium and calcium by $KHCO_3$ was absorbed into the plant less than KOH, so that it remained a lot of mineral element residues rather than KOH in closed system. Plant growth as affected by the foliar spray of ethephon showed growth retardation effect in the plot of solution diluted to 1 : 500 and growth promotion effect in the plot of solution diluted to 1 : 1,000 or 1 : 2,000. The number of petals was the best in the plot of foliar spray of ethephon solution diluted to 1 : 1,000 before flowering at 45 days showing 331 petals compared to control showing 302 petals. The size and area of stem cavity as affected the foliar spray of ethephon was smaller 1 mm and 7%, respectively, in the plot of solution diluted to 1 : 2,000 before flowering at 30 days than in control. Therefore, treating pH stabilization using KOH after floral initiation stage with the foliar spray of ethephon solution diluted to 1 : 2,000 before flowering at 30 days would help to reduce stem cavity size and improve flower quality in hydroponically grown chrysanthemum 'Baekma'.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

An Experimental Study on the Quality Variation by the Number of Production of Recycled Sand and Mechanics Properties of Mortar using Sand Flux Apparatus (샌드플럭스 장치를 이용한 순환모래의 생산횟수별 품질변화 및 모르타르의 역학특성에 관한 실험적 연구)

  • Lee, Sang-Soo;Song, Ha-Young;Kim, Joon-Seok;Kim, Jae-Hwan;Lee, Jong-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.81-88
    • /
    • 2009
  • This study has shown the tendency to enhance Sand Flux, a device of separating screening the foreign matter, for the recycling of construction waste possible to improve the quality of wet type production system meaningfully as part of research. As a result of experiment on the basic material properties, this study had a tendency to improve the quality and performance significantly in case of absolute surface dried density, 0.08mm sieve throughput, volume of clay lumps, and content of organic foreign matter. In addition, as a result of examining the quality characteristics of mortar, this study has shown the tendency that the flow and compressive strength more increased than the mortar using RS-II by utilizing RS-VI recycled sand produced finally through the device Sand Flux. As for the shrinkage properties, this study has shown the character the generation rate of crack of mortar using RS-IV recycled sand produced finally through the device Sand Flux.

  • PDF

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

Papers : Application of Cavitating Venturi for Stable propellant feed system (논문 : 안정적인 액체연료 공급을 위한 Cavitating Venturi 의 응용)

  • Park,Hui-Ho;Kim,Yu;Jang,Eun-Yeong;Lee,Su-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.88-94
    • /
    • 2002
  • For the pressurized propellant supply system of liquid rocket, feed pressure is determined with respect to the chamber pressure of normal combustion state. However, during ignition period the initial chamber pressure is atmosopheric. This may cause overflow, hard-start and even critical damage for the engine. This paper proposes an improved propellant feed system for the stable combustion of liquid rocket. The proposed system utilizes the cavitating venturi to provide stable mass flow rate. Cavitating venturi offers unique flow control capabilities at normal and abnormal combustion state, because flow rate is soley dependent on the upstream absolute pressure and fluid properties, but independent on th downstream condition. Experimental variables are propellant feed pressure and chamber pressure. The effectiveness of cavitating venturi increased when the ratio of actual feed pressure to the cavitating venturi design pressure is increased. It is also found that Kerosene if more effective to supply stable mass flow rate than LOx.

Experimental Evaluation of Internal Blast Resistance of Prestressed Concrete Tubular Structure according to Explosive Charge Weight (프리스트레스트 콘크리트 관형 구조물의 폭발량에 따른 내부폭발저항성능에 관한 실험적 평가)

  • Choi, Ji Hun;Choi, Seung Jai;Yang, Dal Hun;Kim, Jang-Ho Jay
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.369-380
    • /
    • 2019
  • When a extreme loading such as blast is applied to prestressed concrete (PSC) structures and infrastructures for an instantaneous time, serious property damages and human casualties occur. However, a existing design procedure for PSC structures such as prestressed containment vessel (PCCV) and gas storage tank do not consider a protective design for extreme internal blast scenario. Particularly, an internal blast is much more dangerous than that of external blast. Therefore, verification of the internal blast loading is required. In this paper, the internal blast resistance capacity of PSC member is evaluated by performing internal blast tests on RC and bi-directional PSC scaled down specimens. The applied internal blast loads were 22.68, 27.22, and 31.75 kg (50, 60, and 70 lbs) ANFO explosive charge at 1,000 mm standoff distance. The data acquisitions include blast pressure, deflection, strain, crack patterns, and prestressing force. The test results showed that it is possible to predict the damage area to the structure when internal blast loading occurs in PCCV structures.