• Title/Summary/Keyword: 태양광인버터

Search Result 15, Processing Time 0.019 seconds

A Study on Optimal Design of Photovoltaic System for Efficiency Progress (태양광발전시스템의 효율향상을 위한 최적설계에 관한 연구)

  • Choi, Young-Moon;Lim, Jung-Yol
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.175-180
    • /
    • 2009
  • This paper compare the operation characteristic and optimal design of Photovoltaic system by computer simulation. The operation characteristic of Photovoltaic system are evaluated and analyzed considering system parameters of specifications, installations, inclination, azimuth and surrounding conditions etc. From the basis of these results, this study will intend to develop an evaluation, analysis tool and construct database for optimal design of PV system.

  • PDF

The Implementation of the Solar Inverter Monitoring System using an AJAX (AJAX를 이용한 태양광 인버터의 모니터링 시스템 구현)

  • Kwon, Hyo-Sang;Yang, Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1915-1922
    • /
    • 2012
  • In this paper, the Solar Inverter will be monitored by using the AJAX(Asynchronous JavaScript and XML). AJAX is the one of the technologies that can make the RIA(Rich Internet Application) with DHTML(Dynamic Hyper Text Makeup Language) and other java script technology. By using this, a strong application program that is comparable to the general application program can be made. With an existing data-processing technique, the request and response of data can't be processed dynamically on the same page. However, real-time monitoring of data and operation statuses can be confirmed by using the AJAX an asynchronous method of communication. Also without changing the page, the amount of data transmission used the AJAX with significantly small amounts of data to build a Solar Inverter monitoring system that is able to efficiently handle management and monitoring, operating all functions within one page.

Study for Reducing Ripples of the PV Array Output in Grid-Connected Photovoltaic Power System (계통연계헝 태양광인버터의 PV Array 출력리플 저감을 위한 연구)

  • Kim, Hee-Jung;Chung, Yong-Ho;Lee, Ki-Su;Jon, Young-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.202-205
    • /
    • 2006
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

Study on the Harmonic Extraction Technique of the Power Conditioning System using High Performance DSP Controller (고성능 DSP 제어기를 사용한 태양광인버터의 하모닉 추출기법에 대한 연구)

  • Lee, Jeong-Eun;Min, Jun-Ki;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.266-273
    • /
    • 2010
  • The main function of the power conditioning system (PCS) is grid-connection with renewable system. The level of total harmonic distortion(THD) caused by the PCS should be maintained less than 5% according to the IEEE-1547 regulation. The THD is measured by the dedicated instrument, not by the PCS in the domestic products. There should be the necessity for harmonic measurement by the PCS in order to cope with degradation or fault condition. In this paper, the real-time harmonic measurement technique using highperformance DSP controller is presented. The proto-system is manufactured using 32-bit floating DSP processor and tested with 256-point DFT(Discrete Fourier Transform) algorithm. The test result shows that the harmonic calculation time is less than 1 [ms]. It can be used as a auxiliary method for predicting the fault in the PCS system.

Performance improvement of PV_system's inverter that use transformer tap (변압기 탭을 이용한 태양광인버터의 성능개선)

  • Park Noh-Sik;Park Sung-Jun;Kim Kwang-Heon;Lim Young-Cheol;Kwon Soon-Jae;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.511-514
    • /
    • 2004
  • Proposed about new inverter that can use in PV system in this paper. Multi_level inverter that used inverter makes use of 4 transformers is basis, primary winding of each transformer voltage as can do step_up or step_down to appropriate voltage space tap lake. Put circuit that tap that turn in transformer connects properly according to inhibit signal that sense change of input voltage (output voltage of solar cell place) and transformer secondary voltage controls point of contact of relay so that get into fixed output voltage. As a result, can minimise relative harmonic content despite change width of input voltage are wide because number of output voltage level of multi_level inverter does not decrease. Because proposed circuit manufactures is easy and control is easy and is no burden of cost price rise economically, commercialization expected to do easily and this study examined propriety of action as that compose and experiments proposed circuit.

  • PDF