• Title/Summary/Keyword: 탄소섬유판

Search Result 177, Processing Time 0.026 seconds

Post-tensioning System with Externally Unbonded CFRP Strips for Strengthening RC Members (RC 부재의 휨 보강을 위한 외부 비부착형 탄소섬유판 포스트텐션 시스템)

  • You, Young-Chan;Choi, Ki-Sun;Kim, Keung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.147-154
    • /
    • 2008
  • Experimental study has been performed in order to investigate the behavior of RC beams strengthened with externally unbonded post-tensioned CFRP (Carbon Fiber Reinforced Polymer) strips using embedded or stud-type plate anchorages. Total 10 small-scaled specimens were manufactured with the different post-tensioning level and types of mechanical anchorage as a main test parameter. A control specimen and specimens with simply bonded CFRP strips were included to compare the structural performances of each system. From the test results, it was observed that the specimens strengthened with simply bonded CFRP strips showed debonding failure below 50% of CFRP tensile strength due to premature debonding. On the other hand, all the specimens strengthened with post- tensioned unbonded CFRP strips reached the rupture strength of the CFRP strip. Also, it was observed that the specimens with stud-type anchorage have equivalent strengthening performance compared with embedded-type anchorage.

A Study on the Strength Enhancement of Wale in Temporary Retaining Structures (흙막이 지하 가시설 구조체의 띠장 휨 강성 증대를 위한 연구)

  • Lim, Dong Hwan;Lee, Yong Jun;Ahn, Sang Ro
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3C
    • /
    • pp.91-96
    • /
    • 2009
  • The purpose of this study was to investigate a method for the strength enhancement of wale in temporary retaining structures. Tests on the wale structures strengthened with carbon fibre reinforced plastic (CFRP) strips and prestressed with seven wire strands were conducted. From this test, it is found that the flexural stiffness and strength of the wales strengthened with CFRP strips and seven wire strands were significantly improved compared to the unstrengthened one. The ultimate tensile strains of attached CFRP strips on the steel beam were in the range of 8,000 and $11,000{\mu}{\epsilon}$, and it is noticed that the bonding ability with steel and CFRP strips is good. In this paper, a new method for enhancing the strength of wale in retaining structures is suggested.

Failure of RC Slabs Strengthened with CFRP Plate (탄소섬유판으로 보강한 철근콘크리트 슬래브의 파괴)

  • Kim, Joong-Koo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.245-251
    • /
    • 1999
  • Carbon fibre reinforced plastic(CFRP) plate is one of the alternative materials for strengthening of reinforced and prestressed concrete members due to excellent strength and light weight. In this paper, the behavior of slabs strengthened with CFRP plate is observed and analyzed from the test results. Especially specimens with thick plate is tested when large moment and large shear force appear in same position. The failure mode is a peeling-off of the CFRP plate due to flexural-shear crack. This is observed near the loading points with thick plates. Because of this failure mode, thickness of CFRP plates does not influence on the failure loads. Depending on the loading pattern, it is necessary to consider different design criteria for reinforced concrete members with external reinforcement. When large moment and large shear force appear in same location, maximum thickness may limit to 0.6mm and ratio between moment of strengthened slab and moment of unstrengthened slab is proposed 1.5-2.0.

  • PDF

A Study on the Reinforcement Performance of Carbon Fiber Plate(CFP) for Demaged Reinforced Concrete Beam (손상된 철근콘크리트보에 있어서 탄소섬유판의 보강 성능에 관한 연구)

  • Kim, Cheol-Hwan;Ham, Young-Duck;Kim, Ku-Jin
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.3 s.17
    • /
    • pp.109-115
    • /
    • 2005
  • The experimental work was performed to investigate the effect influenced to the hystresis and the flexural strength improvement of RC beam using carbon fiber plates. Major parameters of this experimental program were the section size of carbon fiber plates and the damage level of RC beam before reinforcement. Particularly, the damage level of beam is for the cases damaged by overloads. The damage level is for 30%, 60%, and 100% of flexural strength, and no damaged beams were also tested for comparison with the damaged one. from the test results, it showed that the beams reinforced by carbon fiber plates had the higher strength and lower deformation capacity than the general beams and that it had the same ductility ratio of the general beams.

  • PDF

탄소섬유 강화 복합재료를 이용한 증기발생기용 노즐댐 설계

  • 박진석;김태룡;오제훈;이대길
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.253-258
    • /
    • 1996
  • 원자로의 가동 중지 중이나 재장전시 원자로가 설치되어 있는 수조의 냉각수가 증기발생기 안으로 유입되는 것을 막는 장비로써 노즐댐을 사용한다. 현재의 노즐댐은 알루미늄 재질로 그 무게가 무거워 노즐댐 작업자가 취급하기 어렵다. 이 노즐댐의 경량화와 동시에 구조적 강도를 증가시키기 위해서 비강성이 높은 탄소섬유 강화 복합재료와 굽힘 강성 및 전단강성을 증가시키기 위하여 벌집구조(honeycomb)의 알루미늄을 사용하여 KAERI 노즐댐-II를 설계하였다. 노즐댐에 발생하는 응력 해석을 통하여 중앙판과 측면판의 변위가 충분히 작은 값을 가지면서 파괴지수도 충분히 작은 값이 되는 탄소섬유의 적층각도를 구하였으며, 중앙판은 [$\pm$15]로 적층하고 측면판은 [$\pm$45 ]로 적층 하였다. 그리고 각 판의 최대 파괴지수는 중앙판의 경우 0.32, 측면판의 경우 0.27 이었고 최대변위는 각각 3.1mm, 2.7mm로 노즐댐을 사용할 때 예상되는 하중에 대하여 노즐댐의 구조적 건전성을 입증하였다.

  • PDF

Debonding Failure Model for RC Beams Strengthened with Externally Bonded Prestressed CFRP Plates (탄소섬유판 긴장재로 외부 긴장 보강된 철근콘크리트 보의 부착파괴 모델)

  • Park, Jong Sup;Jung, Woo Tai;Park, Young Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.447-456
    • /
    • 2008
  • This paper suggests a modified debonding failure model for the externally bonded prestressed CFRP plate strengthening system. In order to reduce the error that may occur in the experimental results, statistical analysis of the experimental results produced by previous researchers was conducted to propose a debonding failure model. The experimental results of beams strengthened with bonded CFRP plates have made it possible to verify the debonding failure occurring before the final failure in the prestressing system. The corresponding strain increased with the effective prestress. Accordingly, the debonding failure model was modified by considering the effective prestress so as to fit with the CFRP prestressing system.

Bond Capacity of Near-Surface-Mounted CFRP Plate to Concrete Under Various Temperatures (콘크리트에 표면매입 보강된 탄소섬유 판의 온도에 따른 부착성능)

  • Seo, Soo-Yeon;Kim, Jeong-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.75-83
    • /
    • 2013
  • This paper presents a series of test result in order to study fire resistance capacity of the Near-Surface-Mounted (NSM) Carbon Fiber Reinforced Polymer (CFRP) plate, which are tensile test of CFRP under various temperature loading, temperature loading test of epoxy and bond test of NSM CFRP to concrete under various temperature loading. From the tests, it was found that NSM retrofit method had high efficiency in strengthening concrete under ordinary temperature. However, the strength of the system was able to be drastically decreased even a little increase of surrounding temperature. Especially, bond capacity begins to disappear when the surrounding temperature approaches the glass transition temperature of epoxy. Therefore, it is necessary to improve the fire resistance capacity of both fiber reinforced polymer reinforcement and epoxy for bonding in order to develop safe fire resistance design of structure.

Flexural Behavior and Analysis of RC Beams Strengthened with Prestressed CFRP Plates (프리스트레스트 탄소섬유판으로 보강된 철근콘크리트 보의 휨 거동 및 해석)

  • Yang, Dong-Suk;Park, Jun-Myung;You, Young-Chan;Park, Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.467-474
    • /
    • 2007
  • In this paper, a total of 13 beams with bonding, anchorage system, amount of prestressing and span length as variables of experiment were tested in flexural test and analyzed in finite element analysis; one control beam, two simplified FRP-boned beams, four prestressed FRP-unbonded beams and four prestressed FRP-bonded beams. Also, a nonlinear finite element analysis of beams in the flexural test is performed by DIANA program considered material nonlinear of concrete, reinforcement and the interfacial bond-slip model between concrete and CFRP plates. The failure mode of prestressed CFRP plated-beams is not debonding but FRP rupture. RC members strengthened with external bonded prestressed CFRP plates occurred 1st and 2nd debonding of the composite material. After the debonding of CFRP plates occurs in bonded system, behavior of bonded CFRP-plated beams change into that of unbonded CFRP-plated beams due to fix of the anchorage system. Also, It was compared flexural test results and analytical results of RC members strengthened with CFRF plates. The ductility of beams strengthened by CFRP plates with the anchorage system is considered high with the ductility index of above 3. Analysis results showed a good agreement with experiment results in the debonding load, yield load and ultimate load.

Study on Fatigue Behavior of Carbon Fiber Reinforced Polyimide Composites (탄소섬유강화 복합적층판의 피로특성에 관한 연구)

  • 이창수;황운봉;한경섭;윤병일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.49-60
    • /
    • 1991
  • Fatigue behavior of carbon fiber reinforced polyimide composite materials was studied experimentally and analytically. The physical variables, such as cyclic displacements and hysteresis loop energy were observed during fatigue tests. Fatigue life of the investigated [0/90]$_{2S}$ laminates was predicted by H'||'&'||'H models which was proposed based on the fatigue modulus and resultant strain. The predicted fatigue life by H'||'&'||'H curves was reasonably close to the experimental data. Fractography study shows that fatigue failure mechanism of [0/90]$_{2S}$ laminated composite materials involves failure break, matrix tearing and fiber-matrix debonding as well as delamination of layers.

Structural behavior on the steel beam with strengthening bonded carbon plate (카본판을 접착보강한 강재의 거동분석)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.54-61
    • /
    • 2016
  • The use of advanced composite materials in strengthening and repair of existing structures is increasing rapidly. This paper describes an effectiveness of a bonding of carbon fiber reinforced sheets to corroded steel members for the repair. Three types of surface treatment, what we call cleaning, of corroded plate are chosen as parameters. They are "without cleaning","removal of painting by brushing" and "complete removal of painting". From the experimental study, the following findings are obtained. 1) When the steel plate is subjected to tensile force, carbon fiber sheets adhered to the painted steel gives a higher strength against peeling compared to that of the plate without painting, 2) The grade of surface treatment, or cleaning of the corroded steel plate affects the strengthening effect.