• Title/Summary/Keyword: 탄성전자

Search Result 322, Processing Time 0.027 seconds

Measurement of Flexural Modulus of Lamination Layers on Flexible Substrates (유연 기판 위 적층 필름의 굽힘 탄성계수 측정)

  • Lee, Tae-Ik;Kim, Cheolgyu;Kim, Min Sung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.63-67
    • /
    • 2016
  • In this paper, we present an indirect method of elastic modulus measurement for various lamination layers formed on polymer-based compliant substrates. Although the elastic modulus of every component is crucial for mechanically reliable microelectronic devices, it is difficult to accurately measure the film properties because the lamination layers are hardly detached from the substrate. In order to resolve the problem, 3-point bending test is conducted with a film-substrate specimen and area transformation rule is applied to the cross-sectional area of the film region. With known substrate modulus, a modulus ratio between the film and the substrate is calculated using bending stiffness of the multilayered specimen obtained from the 3-point bending test. This method is verified using electroplated copper specimens with two types of film-substrate structure; double-sided film and single sided film. Also, common dielectric layers, prepreg (PPG) and dry film solder resist (DF SR), are measured with the double-sided specimen type. The results of copper (110.3 GPa), PPG (22.3 GPa), DF SR (5.0 GPa) were measured with high precision.

Application of CAE Stress Analysis in Electronics Components (전자부품 산업에서의 응력해석 CAE적용)

  • 윤정호;안상훈
    • Journal of the KSME
    • /
    • v.33 no.2
    • /
    • pp.145-151
    • /
    • 1993
  • 전자산업이 고도화되어감에 따라 전자기술은 소재 . 기계분야와 복합된 기술의 발전이 가속화 되어 가고 있다. 특히 이 글에서는 응력해석 CAE 기술이 전자부품산업에 적용되는 사례를 소 개하고자 한다. 그 중 하나는 하드디스크의 정밀부품 중의 하나인 스핀들 모터용 Hub의 절삭 가공시 고려하여야 하는 탄성 변형량을 해석하고 이를 적용하는 사례이고 또 하나는 Audio Deck의 Capatan Shaft를 지지하는 플리스틱 Base가 신뢰성 시험도중 또는 고온 부하시 발생하는 크리프현상을 해석하여 적용하는 사례이다. 이 글에서 소개하는 두 가지 사례는 전자부품산업에 응력해석 CAE를 적용할 수 있는 예들 중 빙산의 일각에 불과할 뿐이고, 이와 유사한 전자부품에 응력해석 CAE를 적용할 수 있다.

  • PDF

Implementation of Strain Imaging Modality in Medical Ultrasonic Imaging System (초음파 의료 영상 시스템에서 탄성 영상의 구현)

  • Yoon Ra-Young;Kwon Sung-Jae;Bae Moo-Ho;Jeong Mok-Kun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.53-62
    • /
    • 2005
  • This paper proposes a method of measuring and visualizing the elasticity distribution of the human soft tissue to detect tumors or cancers which have been difficult to diagnose in conventional medical ultrasonic B-mode images. To measure the stiffness of soft tissue, first, pressure is applied to deform the tissue being imaged, and then the amount of mechanical displacement is determined from correlation coefficients obtained from ultrasonic data downconverted into the baseband. We confirmed the feasibility of imaging tissue stiffness by computer simulation and experiment.

Characteristics of pi-shaped Ultrasonic Motor (TT형 초음파 모터의 특성평가)

  • Yun, Yong-Jin;Park, Sung-Hee;Kang, Sung-Hwa;Lim, Ki-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.189-190
    • /
    • 2005
  • 본 논문에서는 카메라폰용 광학줌(Optical zooming)과 자동초점조절장치(Auto Focusing,AF)에 쓰일 초음파모터를 제작하였다. 초음파모터의 제작 및 시뮬레이션은 유한요소해석 프로그램인 ATILA 5.2 1(Magsoft co.)를 사용하여 디자인설계에 따른 구동특성을 고찰하였고 제작된 초음파모터는 한쪽 면이 없는 사작형의 탄성체를 제작하였으며 탄성체의 양쪽 다리에 각각 압전체를 부착하였다 또한 압전세라익의 조성은 0.9Pb$(Zr_{0.51}Ti_{0.49})O_3$ - 0.1Pb$(Mn_{1/3}Nb_{1/3}Sb_{1/3})O_3$ 의 조성으로 설계하였고 시편의 제조는 7-layer로 적층하였다. 제작된 압전세라믹의 치수는 6*2*0.35mm$^3$(길이*폭*두께)로 제작하였다. 또한 탄성체의 외형치수는 8*4*2mm$^3$로 제작하였으며 회전축의 지름은 2mm로 제작하였다. 인가전압과 공진주파수가 각각 20Vpp, 64kHz일 때 소비전력은 0.3[W]이며 회전속도는 500rpm 으로 측정되었다.

  • PDF

Compliance Control of a Direct-Drive Manipulator using Phase-Difference of Ultrasonic Motor (초음파 모터의 위상차를 이용한 직접구동 매니퓰레이터의 컴플라이언스 제어)

  • 오금곤;김대현;김영동;김재민
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.608-615
    • /
    • 1999
  • In this paper, the compliance control method was propoSL'Cl and the phase-difference operating principle of an u ultrasonic motor described. The compliance control can he implementtcD with spring/damper properties of the r musculo-skeletal system of the actual limb in controlling its net configuration and movement. The proposed p phase-difference driving scheme is verifitcD through the computer simulation. Also, $textsc{k}$rformance of the proposed c control method of a two-link direct-drive manipulator are examinLD by the experimental results with resptc'Ct to s spring/ damper properties.

  • PDF

Preparation of EPDM/Polyamide12 Elastomers through Electron Beam Irradiation (전자선 조사를 통한 EPDM/Polyamide12 탄성체의 제조에 관한 연구)

  • Jung, Hyo Shin;Park, Jung Il;Kang, Phil-Hyun;Choi, Myung Chan;Chang, Young-Wook;Hong, Sung Chul
    • Polymer(Korea)
    • /
    • v.37 no.5
    • /
    • pp.571-578
    • /
    • 2013
  • Polyamide12 (PA12) is blended with ethylene propylene diene rubber (EPDM) at various compositions in the presence of maleated EPDM (mEPDM) to afford blend materials having the characteristics of thermoplastic elastomer (TPE). The EPDM/PA12 melt-blends are further irradiated with electron-beam (e-beam) at 0~100 kGy dosage, yielding selective crosslinking between EPDM chains while retaining melt-processibility originated from PA12 phase. mEPDM acts as a compatibilizer and affords additional improvements in mechanical properties of the EPDM/PA12 blend. With 25 kGy of e-beam irradiation and mEPDM, the EPDM/PA12 blends successfully exhibit TPE behaviors with reasonable elastomeric and mechanical properties.

Comparison of peripheral vascular compliance between normal and diabetic groups using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Nam, Ki-Chang;Kim, Su-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.15-20
    • /
    • 2007
  • Recently the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal(n=850) and diabetic(n=50) groups vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of the second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a rapresents vascular compliance. This study found out that when vascular compliance is decreased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy, $-1.09{\pm}0.14$ is statistically lower than the normal group, $-0.81{\pm}0.09$ (p<0.05). In conclusion, we suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

A study on the correlation between the degree of elasticity uniformity and the dynamic performance in the overhead contact lines (전차선로 탄성도 불균일율과 동역학적 성능과의 관계에 대한 연구)

  • Park, Sa-Hoon;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.502-502
    • /
    • 2007
  • A catenary system should be designed to have an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity uniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate the degree of elasticity uniformity of a catenary according to the literature survey. The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for various different configurations of catenary systems using a beam element based FEM program. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity uniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF