• Title/Summary/Keyword: 타워효과

Search Result 75, Processing Time 0.02 seconds

Ground Effect of a Rotor Blade on a Whirl Tower (훨타워 로터 블레이드의 지면효과)

  • Kang, Hee-Jung;Kim, Seung-Ho
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.74-81
    • /
    • 2011
  • A numerical simulation is performed to study the ground effect of a rotating rotor blade on a whirl tower using unstructured overset mesh. The aerodynamic change of the rotor blade by the structure around the whirl tower is also considered. The calculated results showed good agreement with the experiment for the hover performance. The ground effect of the rotor blade is investigated by comparing with the calculated results for the out of ground condition and the results of an analytic model.

Dynamic Behavior Analysis of Floating Offshore Wind Turbine Including Flexible Effects of Tower and Blade (타워와 블레이드의 탄성효과를 고려한 부유식 해상풍력발전기의 동적거동해석)

  • Jung, Hye-Young;Sohn, Jeong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.905-911
    • /
    • 2012
  • To establish a floating offshore wind turbine simulation model, a tension leg platform is added to an onshore wind turbine. The wind load is calculated by using meteorological administration data and a power law that defines the wind velocity according to the height from the sea surface. The wind load is applied to the blade and wind tower at a regular distance. The relative Morison equation is employed to generate the wave load. The rated rotor speed (18 rpm) is applied to the hub as a motion. The dynamic behavior of a 2-MW floating offshore wind turbine subjected to the wave excitation and wind load is analyzed. The flexible effects of the wind tower and the blade are analyzed. The flexible model of the wind tower and blade is established to examine the natural frequency of the TLP-type offshore wind turbine. To study the effect of the flexible tower and blade on the floating offshore wind turbine, we modeled the flexible tower model and flexible tower-blade model and compared it with a rigid model.

Design of Automatic Shoes Tower Using NFC (NFC를 이용한 자동 신발 타워 설계)

  • Jang, Eun-Gyeon;Ann, So-Hyeon;Yim, Dae-Geun;Kim, Yu-Bin;Yu, Seung-Su
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.295-296
    • /
    • 2018
  • 본 논문은 입 출차를 하는 주차타워의 원리를 바탕으로 NFC를 활용하여 신발을 반 출입하고, IoT 센서를 이용하여 신발의 관리를 편리하게 도와주는 자동 신발타워이다. 수동으로 번호를 입력하던 주차타워와는 다르게 제안한 신발타워는 NFC에 있는 고유ID값을 활용하여 인증된 사용자가 신발장의 센서 터치로 본인의 신발을 반 출입하도록 한다. 신발장 관리 시스템은 신발의 임의적인 반출을 가능하게 하며, IoT센서를 탑재하여 신발장 내부에 향균, 건조, 온도 조절 등의 효과를 탑재하여 신발의 관리를 편리하게 도와주는 기능들을 제공한다.

  • PDF

Effect of an Opening on Buckling Strength of Polygonal Section Wind Turbine Tower (다각형 단면 풍력타워 좌굴강도에 대한 개구부의 영향)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.163-163
    • /
    • 2011
  • 풍력타워 기둥구조물에는 유지관리 등의 이유로 출입구 역할을 하는 개구부가 존재하게 된다. 다각형 타워구조물에 개구부형상이 존재하게 되면 압축좌굴 강도에 영향이 있을 것으로 예상되지만, 이를 정량적으로 평가하거나 예측하기는 용이하지 않고 간접적으로 판단할 만한 관련 기준이나 지침도 부족한 상태이다. 이에 최병호 등(2011)에서 다룬 다각형 단면 기둥구조물의 하단에 개구부를 형상화한 수치해석 모델을 수립하고 축방향 압축하중을 재하하는 탄성좌굴 해석 및 비선형비탄성해석을 수행하였다. 본 논문에서는 기존 다각형 단면 기둥모델 중에서 6각형 단면모델에 관해 중점적으로 다루고 있다. 다각형 단면 기둥 해석모델은 단순한 다각형 단면 타워구조에 대해서 뿐 만 아니라, 각 subpanel에 종방향 보강재를 둔 모델에 대해서도 추가적으로 검토하였다. 개구부의 형상은 높이 2000mm, 폭 800mm이며 상하부에 만곡부를 둔 형태이다. 수치해석은 3차원 유한요소해석프로그램인 ABAQUS를 이용하여 수행하였으며, 보강방안으로는 일정범위까지의 모듈 subpanel의 판두께를 보강하는 방안과 edge stiffener를 적용하는 방안에 대해서 검토하였다. 각각의 보강방식에 따른 효과를 비교해 보기 위해 개구부가 없는 모델, 단순히 개구부만 설정한 모델, 판두께를 보강한 모델, edge stiffener로 보강한 모델에 대해 비교해석을 수행하였다. 보강재 없는 단순 다각형 타워구조 모델에 대한 해석결과로부터 개구부로 인한 강도저하는 미미한 수준인 것으로 나타났다. 반면, 종방향 보강재가 적용된 6각형 단면 타워구조 모델에서는 개구부로 인한 강도저감이 22.9%로 높게 나타났으며 상당한 영향이 있는 것으로 분석되었다. 또한 개구부 주변의 판두께 보강이나 edge stiffener보강 등으로 상당한 강도향상 효과가 확인되었으나, 개구부로 인해 손실된 강도 수준을 완전히 회복하는 수준에 미치지 못하는 것으로 나타났다. 따라서, 향후 다양한 보강방식에 대한 보다 포괄적인 변수연구를 통해 개구부의 영향 없이 온전한 다각형 단면 타워 구조의 극한강도에 도달되기 위한 보강 조건에 대해 검토될 필요가 있을 것으로 사료된다.

  • PDF

Comparison of Effect on Fire Protection Tower for Waterproofing Time by FDS (FDS를 이용한 산불소화시설 방수시간에 따른 화재 영향 비교)

  • Kwon, Hyeon-Gyeong;Ko, Kyoung-Ju;Jang, Jun;Kim, Jong Bae
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.190-191
    • /
    • 2017
  • 본 연구는 산림 공간에서 산불소화시설인 수관수막타워의 방수시간에 따른 화재에 미치는 영향을 FDS(Fire Dynamics Simulator, 화재시뮬레이션)로 비교하였다. 본 연구를 진행하기 위한 기본 조건은 수관수막타워 높이 20m, 방수길이 40m, 방수량 400Lpm으로 해석공간 상에 수막타워를 3기 설치하였다. 수관수막타워 작동 초반 화재온도 $668.5^{\circ}C$에서 작동 450초 후 $145.6^{\circ}C$으로 감소되는 효과를 볼 수 있다. 이는 '산불소화시설 설치 및 운영 관리 지침'의 제3조 11절 6항의 '수관수막설비는 산불 접근 예상시간보다 10분전에 가동되도록 해야 한다.'의 타당성을 마련할 수 있다.

  • PDF

A Study for Felling Impact Vibration Prediction from Blasting Demolition (발파해체시 낙하충격진동 예측에 관한 연구)

  • 임대규;임영기
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.43-55
    • /
    • 2004
  • Use term of tower style construction exceeds recently. Accordingly, according to construction safety diagnosis result, achieve removal or Improvement construction. But when work removal, must shorten shut down time. Therefore, removal method of construction to use blasting demolition of construction is very profitable. Influence construction and equipment by blasting vibration and occurrence vibration caused by felling impact. Is using disadvantageous machine removal method of construction by and economic performance by effect of such vibartion. Therefore, this research studied techniques to forecast vibartion level happened at blasting demolition and vibration reduction techniques by use a scaled model test.

An Optimal Design Algorithm of Pile Supported Foundations of Tower Cranes (타워크레인의 파일기초 최적설계 알고리즘 개발)

  • Ryu, Sang-Yeon;Seo, Deok-Seok;Kim, Sun-Kuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.95-101
    • /
    • 2009
  • As buildings increase in height, lifting plans are becoming increasingly important on construction sites. As a critical piece of load-lifting equipment, the tower crane deserves a well thought-out stability review, since it has a significant impact and is very vulnerable to structural safety disaster. To ensure the structural stability of a tower crane, its lateral support or pile supported foundation designs must include consideration for stability, and pile foundation must be used if site conditions prevent soil from providing the required bearing capacity, or prevent the foundation from being increased to the required extent. Pile supported foundation design requires thorough and systematic review, as more stability parameters need to be considered than with an independent foundation. This paper intends to develop an optimal design algorithm that can minimize associated costs while ensuring the fundamental stability of pile supported foundation design, limiting the scope of research to fixed-type trolley tower cranes using pile supported foundations. The findings herein on pile foundation stability review parameters, process and optimal design are expected to improve the operational efficiency of staff concerned, and reduce the time and efforts required for pile foundation design.

Inferring Regional Scale Surface Heat Flux around FK KoFlux Site: From One Point Tower Measurement to MM5 Mesoscale Model (FK KoFlux 관측지에서의 지역 규모 열 플럭스의 추정 : 타워 관측에서 MM5 중규모 모형까지)

  • Jinkyu Hong;Hee Choon Lee;Joon Kim;Baekjo Kim;Chonho Cho;Seongju Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.138-149
    • /
    • 2003
  • Korean regional network of tower flux sites, KoFlux, has been initiated to better understand $CO_2$, water and energy exchange between ecosystems and the atmosphere, and to contribute to regional, continental, and global observation networks such as FLUXNET and CEOP. Due to heterogeneous surface characteristics, most of KoFlux towers are located in non-ideal sites. In order to quantify carbon and energy exchange and to scale them up from plot scales to a region scale, applications of various methods combining measurement and modeling are needed. In an attempt to infer regional-scale flux, four methods (i.e., tower flux, convective boundary layer (CBL) budget method, MM5 mesoscale model, and NCAR/NCEP reanalysis data) were employed to estimate sensible heat flux representing different surface areas. Our preliminary results showed that (1) sensible heat flux from the tower in Haenam farmland revealed heterogeneous surface characteristics of the site; (2) sensible heat flux from CBL method was sensitive to the estimation of advection; and (3) MM5 mesoscale model produced regional fluxes that were comparable to tower fluxes. In view of the spatial heterogeneity of the site and inherent differences in spatial scale between the methods, however, the spatial representativeness of tower flux need to be quantified based on footprint climatology, geographic information system, and the patch scale analysis of satellite images of the study site.

Construction of Super-block Unit Curtain Wall for High-rise Buildings Utilizing a Specialized Installing Equipment (전용 양중틀을 활용한 초고층 건물의 슈퍼블럭 유닛 커튼월 시공)

  • Chung, Sam-Yong;Lee, Sang-Heon;Ohk, Young-Mu
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.174-181
    • /
    • 2004
  • We will introduce a method of construction of super-block curtain wall applied to Tower Palace III which is the highest high-rise complex building in Korea. Up-up method is utilized on Tower Palace III to shorten the term of works and it is that the curtain walls for the belt wall part are installed after the rests. The belt wall structure increases the horizontal structural stiffness of the building. The method of construction of super-block curtain wall is developed and used to raise and install the curtain wails of the belt wall floor. It is that the large block of curtain walls corresponding to three stories is fabricated on the ground in advance and the block is installed at a time by a tower crane. Specialized installing equipment :,s newly developed and applied to install the super-block. curtain wail. The curtain wall of the upper floor of the belt wall part is installed after the super-block. The installing equipment for this floor is developed utilizing a mini excavator and vacuum suctions. The application of this method had made it possible to omit the setting up the scaffold and financial profits such as the shortening of the terms of works was realized. The safety of works was secured and the productivity was also improved.

  • PDF