• Title/Summary/Keyword: 타격에너지

Search Result 65, Processing Time 0.03 seconds

Performance Improvement of an Integrated-type Fully-Hydraulic Breaker by Sensitivity Analysis (일체형 순수유압식 브레이커의 민감도해석에 의한 성능 향상)

  • Choi, S.;Chang, H.W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2009
  • The performance improvement of a small-size integrated-type fully hydraulic breaker is studied in this paper. Mathematical modeling of the breaker is established and verified by experiment. Through sensitivity analysis using AMESim, the key design parameters are selected and nearly optimized to maximize the impact energy as well as to improve the dynamic characteristics such as the piston upper chamber pressure, piston and valve displacements. As a result, the impact energy, blows per minute(bpm) and output power are increased by 52.9%, 1%, and 55.6%, respectively compared with the current design. The dynamic characteristics of the piston upper chamber pressure, piston and valve displacements are also improved by the design change.

  • PDF

Performance Optimization of a Fully Hydraulic Breaker using Taguchi Method (Taguchi 방법을 이용한 순수 유압식 브레이커의 성능 최적화)

  • Kwak, K.S.;Chang, H.W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • The optimal design of a large-size fully hydraulic breaker is studied in this paper. Mathematical modeling of the breaker is established and verified by experiments. Through sensitivity analysis, the key design parameters of the breaker are selected, which mostly affect the performance of the breaker. Taguchi method is used to optimize the key design parameters in order to maximize the output power through simulation using AMESim. As a result, the impact energy is increased by 18.9% and the output power is increased by 12.4% compared with the current design. The pressure pulsation in the supply line is also reduced by the optimization.

  • PDF

Piezoelectric Materials and Their Properties for Energy Harvesting (에너지 하베스팅용 압전 소재 및 특성 분석)

  • Jeong, Soon-Jong;Lim, Dong-Hwan;Lee, Dae-Su;Kim, Min-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.333-333
    • /
    • 2010
  • 압전형 에너지 하베스팅 소자는 외부에서 버려지는 기계적 진동 혹은 타격과 관련된 에너지로부터 전기 에너지를 획득할 수 있다는 잇점이 있다. 그러나 현재 이 방식으로부터 획득될 수 있는 에너지는 매우 작다는 단점이 있다. 이러한 문제들을 해결하기 위하여 본 연구에서는 두 가지 형태의 압전 소재를 제작하였다. 에너지 하베스팅 소자용 고효율 압전 세라믹와 결정배향된 세라믹을 제작하고 이에 대한 성능을 조사하였다. 결정 배향된 세리믹에서는 1 N의 외부 충격조건에서 소재가 100 V, 1 mW의 전력을 발생하였다.

  • PDF

Research of Hydraulic Breaker with Rock Properties Predictability Using the ICT (ICT 융합기술을 활용한 암반특성 예측기능을 가진 유압 브레이커 개발에 관한 연구)

  • Yoon, Bok Joong;Lee, Kil Soo;Lim, Hoon;Lee, Ho Yeon;Lee, Myung Gyu;Kwon, Hyuk Jin;Kim, Kab Tae;Joo, Jin Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.683-689
    • /
    • 2017
  • We have carried out the development for hydraulic breaker which can be operated by optimal mode with ICT convergence technology. This developed system can predict the rock properties. Moreover, this system can maximize the energy efficient with intelligent control of hydraulic system. In order to provide the optimal impact force, this system can measure the descending depth of piston with the proximity sensor and discriminate the rock properties with the measuring data and control the piston stroke using solenoid valve eventually. In addition, we have developed the controller, display module and operating device for cascade (multi-level impact) system and applied the module which can communicate each system by wireless communications. In conclusion, the control system which can control the multi-level impact in accordance with strength of rocks has been developed and approved by several field tests.

A Study on Test Method for Performance Evaluation of Rockfall Protection Fence (Post) (낙석방지울타리(지주) 성능평가를 위한 시험방법 연구)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.2
    • /
    • pp.5-12
    • /
    • 2022
  • In this study, a field test was conducted to present a test method for performance evaluation of a rock fall prevention fence, centering on the vertical drop test among the existing test methods of the rock fall prevention fence. A test to determine the support capacity of a rockfall prevention fence in Korea is usually conducted using a combination of wire mesh, poles, and wire rope, and the location of the impact of falling rocks has been conducted centered on the center of the wire mesh. However, in the case of domestic papers and test data, there is no data on direct hit of post. Therefore, the amount of displacement and weak section were analyzed when the impact on 100kJ class rock energy was hit on the post, centering on the Rockfall Protection fence (highway type No. 2).

Drivability and Bearing Capacity of PHC Pile Foundation (PHC 말뚝의 항타시공성 및 지지력에 관한 연구)

  • Lee, Myung Whan;Lee, In Mo;Kim, Sang Gyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.223-234
    • /
    • 1993
  • The main characteristics of PHC piles is that silica material and autoclave curing technique are used when manufacturing to have higher strength than PC piles. In this paper, pile drivability and bearing capacity characteristics of the PHC piles are studied through numerical analysis based on wave propagation theory, driving records and pile load tests in situ. It is found that we can have higher bearing capacity by using the PHC piles rather than the PC on condition that the most effective driving equipment is chosen when driving the pile. In other words, since the PHC piles have higher resistance to driving energy, the heavier ram can be used in the driving process, which results in the higher bearing capacity.

  • PDF

Study on Pullout Behavior and Determination of Ultimate Uplift Capacity of Pile Driven in Small Pressured Chamber (소형 압력 토조내에 타입된 말뚝의 인발 거동과 극한 인발 지지력 결정에 관한 연구)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.11 no.2
    • /
    • pp.19-28
    • /
    • 1995
  • Based on the various test data acquired in the field, the large pressure chamber and the small pressure chamber, uplift behaviors and method of determining the ultimate uplift capacity of pile driven in small pressure chamber were studied. After uplift pile experienced 2 or 3 sudden slip due to increase of uplift load, complete pullout failure was occurred. Thus, it appears that the ultimate uplift capacity could be identified as the load at displacement where first slip occurs. The ultimate uplift capacity might be determined in every test and the disturbance after first uplift test could be recovered by adding one blow of the drop hammer, which had to depend on the model pile capacity.

  • PDF

Perspectives on the Future of Nuclear Power in the United States (강연 - 미국 원자력 미래에 대한 전망)

  • Kelly, John E.
    • Nuclear industry
    • /
    • v.38 no.7
    • /
    • pp.9-19
    • /
    • 2018
  • 존 켈리 회장은 7월 12일 경주시 힐튼호텔에서 열린 '원자력 안전 및 해체산업 육성 국제 포럼'에 참석하여 'Perspectives on the Future of Nuclear Power in the United States'를 주제로 특별강연을 했다. 켈리 회장은 강연을 통해 미 행정부의 원자력정책, 미국 원자력산업의 단기 도전 과제, 전력 생산에서의 이산화탄소 감축과 원전 역할, 원전의 지속적인 운영, 미국에서 진행되는 신형 원자로 설계 등을 피력했다. 켈리 회장은 이날 언론과의 인터뷰에서 "한국은 원자력산업 강국인데, 원전 안전성에 대한 과학적인 근거보다 정치적 이슈로 신규 원전을 짓지 않고 수명 연장 대신 조기 폐쇄를 결정한 것은 우려할 사안"이라고 말하고 "원전산업 축소는 장기적으로 기업의 전력 확보가 어려워져 경제적 타격을 입는다. 특히 한국은 원전을 수출하면서 탈원전정책을 펴면 수출에 지장을 받지 않을까 걱정된다."고 밝혔다. 켈리 회장은 MIT 원자력공학박사로 미국 에너지부(DOE) 원자력에너지 기술책임자를 지냈다. 본고는 발표 내용을 정리한 것이다.

  • PDF

A review on estimation and comparison of rainfall kinetic energy using disdrometer: a case study of Sangju (광학우적계를 활용한 강우 운동에너지 산정 및 비교에 관한 연구: 상주지역을 중심으로)

  • Yeon, Min Ho;Van, Linh Nguyen;Song, Min Geun;Lee, Gi Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.129-129
    • /
    • 2022
  • 국내에서 발생하는 토양침식(soil erosion)은 주로 강우에 의해 발생하며, 이로 인해 농경지 유실, 탁수 발생, 하천 통수능 저하 등 여러 수문학적·환경적 문제가 발생한다. 따라서 유역 내 토양침식 위험지역을 선별하고, 해당 지역의 토양유실 및 유사의 발생량을 산정하는 것은 토양보전 대책 수립 시에 중요한 지표로 활용된다. 침식-유사유출의 물리적 과정은 크게 '강우에 의한 토양 분리(detachment by raindrop)'와 '지표류에 의한 토양 분리(detachment by overlandflow)'로 나눌 수 있으며, 그중 강우에 의한 토양 분리는 수침식(water erosion)의 첫 번째 과정 중 하나로 강우 시 낙하하는 강우 입자들이 갖는 운동에너지가 지표면을 타격할 때 토양체로부터 토양입자가 분리되는 과정이다. 따라서 강우에 의한 토양분리량 산정을 위해서는 강우 운동에너지(rainfall kinetic energy, KE)의 정확한 계산이 요구된다. 그러나 기후 및 지리적 특성 등 여러 조건에 따라 강우 운동에너지는 지역마다 다르게 나타나며, 이로 인해 강우 운동에너지 추정이 매우 어려운 실정이다. 따라서 강우 운동에너지 추정은 주로 강우강도(rainfall intensity, I)와의 관계를 이용한 함수식을 활용한다. 본 연구에서는 대상 지역인 상주지역에 광학우적계(disdrometer)를 설치하여 2020년 6월부터 2021년 12월까지 관측된 37개의 강우 사상에 대하여 KE-I의 관계를 분석하고, 이를 통해 강우 운동에너지식을 도출하였다. 또한, 기존에 국외 및 국내에서 제시된 선형(linear), 멱함수(power-law function), 지수함수(exponential function) 형태의 강우 운동에너지 공식과 본 연구에서 산정된 KE를 비교하였다. 그 결과 비체적 강우 운동에너지에서 Sanchez-Moreno et al. (2012)가 제안한 멱함수 형태의 공식이, 비시간 강우 운동에너지에서 Kinnel (1981)이 제안한 지수함수 형태의 공식이 각각 강우 운동에너지 추정에 통계적으로 유의한 것으로 나타났다.

  • PDF

Fighting Action Games applied Energy Concepts (에너지 개념을 도입한 대전형 액션 게임)

  • Lee Myun-Sub
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 2006
  • This paper proposes intelligent characters for fighting action games to which energy concepts are applied for more realistic implementation than those of previous researches. The intelligent characters decide their actions in consideration of their energy level as well as a current action, the step of the action, the distance, and past actions of opponent characters that were used in existing intelligent ones. We used two types of energy, HP(Health Point) and MP(Mana Point), that were frequently employed in recent on-line games. We experimented with proposed intelligent characters to investigate whether the intelligent characters loam proper actions and cope with opponent characters in consideration of their energy levels. Experimental results showed that the intelligent characters reacted to the best actions to obtain high score if their energy is sufficient, otherwise they did the actions to recharge their energy. From this observation, we could conclude that the proposed intelligent characters worked well and did effective actions in consideration to the their energy.

  • PDF