The Relationship between Habitual Patient-Reported Symptoms and Signs in the Soft Contact Lens Wearers (소프트 콘택트렌즈 착용자에서 평상시 나타난 증상에 관한 연구)

  • Lee, Koon-Ja;Buyn, Jang-Won;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2008
  • Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.

  • PDF

Characteristics of Accommodative Lags Determined by Objective and Subjective Methods and Their Correlation (타각적 및 자각적으로 결정된 조절래그의 특성과 상관관계)

  • Yu, Dong-Sik;Kwak, Ho-Weon;Roh, Byeong-Ho;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.333-339
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate clinical characteristics of subjective accommodative lags determined by fused cross-cylinder (subjective method), and an open-field autorefractor (objective method) under uncorrected and corrected conditions. Methods: Thirty three healthy subjects (26 males and 7 females aged $23.73{\pm}1.35$ years from 22 to 27 years) participated. Four methods were used to determine accommodative lag: (1) a subjective method with the fused cross-cylinder (FCC) under +2.00 D fogging lenses condition, (2) an objective method with the autorefractor under uncorrected condition (3) a corrected method (effective accommodative lag) using equations presented by Gwiazda et al. in objective methods, and (4) a corrected method using equations presented by Mutti et al. in objective methods. Results: The mean accommodative lags were 0.72 D for subjective method, 0.82 D for uncorrected objective method, 0.88 D for corrected method with Gwiazda's equations, and 0.78 D for corrected method with Mutti's equations. There were significant differences between the objective accommodative lags, but no significant differences between the objective and subjective accommodative lags. The effective accommodative lags showed significant correlations between phorias and refractive errors. The effective accommodative lag by Mutti's equations had a high correlation with uncorrected accommodative lags (r=0.99, p<0.001). Conclusions: The objective accommodative lag correlated with phorias and refractive errors. Especially, The effective accommodative lag using Mutti's equations may be considered for clinical availability and qualitative evaluation associated with symptoms.

Comparison of the Clinical Effect after Wearing Conventional and 2-Weeks Cosmetic Tinted Contact Lens (일반 미용 칼라 콘택트렌즈와 2주 교체용 미용 칼라 콘택트렌즈 착용에 따른 임상성능 비교)

  • Kim, Chang Jin;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2009
  • Purpose: To compare and analyze the ocular changes after wearing conventional and 2-weeks cosmetic tinted contact lens, which were made of different material and fabrication method. Methods: Thirty five university students, age of twenties, participated in this study. With daily wearing schedule, they had worn temporary cosmetic tinted lens for 2 weeks and conventional tinted lens for two month in their right and left eye, respectively. Subjective symptoms and objective signs were graded by using CCLRU scales and corneal thickness were measured after 1 day and 2 months wearing, and under or over 5 hours wearing in a day, respectively. Results: Major subjective symptoms found in the student wearing cosmetic tinted contact lens for a 1 day and 2 months were dryness, redness, foreign body sensation and itchiness. It was also found that those symptoms were more severe in left eye (conventional cosmetic tinted contact lens) than right eye (2-weeks cosmetic tinted contact lens). However, symptoms of redness in both eyes showed statistically significant difference in the case of 1 day and 2 months wearing and under or over 5 hours wearing in a day (p=0.000). After 2 months wearing, left eye with conventional cosmetic tinted contact lens showed limbal redness (p=0.000) and bulbar conjunctival redness (p=0.012) with statistically significance, whereas there was no significant difference in both eyes before lens wear. Left eye showed statistically significant changes in all objective signs, but right eye showed palpebral conjunctival redness, corneal staining and conjunctival staining. Therefore, it was concluded that conventional cosmetic tinted contact lens may be more effective on ocular changes after wearing of lens. A statistically significant changes in both eyes after wearing lens were found that corneal thickness increased about $5{\mu}m$ (p=0.001) in right eye whereas $7{\mu}m$ (p=0.004) in left eye. Conclusions: A statistically significant number of participants in this study preferred to wearing of high Dk/t temporary cosmetic tinted contact lens made by sandwich method which resulted in less ocular changes and may give more healthy and safe ocular conditions.

  • PDF

Visual Problems and Refractive Error at Video Display Termianls (VDT사용자의 시기능 불편과 굴절이상)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.75-86
    • /
    • 1998
  • The purpose of this study is to evaluate the effects of continuing work on VDT(video display terminal), therefore this study examined visual fatigue, unaided visual acuity, refractive error, accommodation and horizontal phoria of 152 subjects who did two hour long VDT work. For the ocular symptoms, the greatest number was tired eyes accounting for 45.71%. In the visual symptoms, blurred vision was the hightest rate of 80.39% and in case of systemic symptoms shoulder pain was 33.33% marked top ranking. The average of near visual acuity decresed almost 10% from 0.47 to 0.42, but refractive error increased about 0.10D to the direction of myopic shift. The amplitude of accommodation decreased approximately 0.72D from 7.46D to 6.74D. Accommodation facility was delayed from 2.27 second to 2.50 second, the amplitude of positive relative accommodation was decreased from 4.76D to 4.16D and the amplitude of negative relative accommodation was decreased from 2.46D to 2.33D. The horizontal phoria shifted to the direction of esophoria from $1.82{\Delta}$ to $3.24{\Delta}$.

  • PDF

The Investigation of the Changes of Visual Problems in VDT Workers (VDT 작업 전·후 시기능 변화)

  • Gang, Myoung Jin;Choe, Oh Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.33-39
    • /
    • 2002
  • The purpose of this study is to evaluate the effects of continuing work on VDT(video display terminal). Therefore, we examined visual fatigue by a questionnaire and measured frequency of blinking, tear film break-up time(BUT), height of palpebral fissure, visual acuity, refraction with retinoscopy and accommodation before and after two hour long VDT work. For the ocular symptoms, the greatest number was tired eyes accounting for 34%. In the visual symptoms, blurred vision was the highest rate of 83% and in case of systemic symptoms, shoulder pain was 38% marked top ranking but other symptoms were also distributed similar rate. The frequency of blinking during VDT work decreased significantly comparing with the one at rest. The average frequency of blinking is 8/min during VDT work and 22/min at rest. The BUT measured immediately after VDT work decreased much more than in the resting state. The average BUT was 7sec immediately after VDT work and 12sec at rest. The height of palpebral fissure during VDT work increased significantly comparing with the value at rest. The average height of palpebral fissure was 7.69mm at rest and 9.04mm during VDT work. The average visual acuity decreased almost 9.5% from 0.63 to 0.57, but refraction with retinoscopy increased about 0.28D to the direction of myopic shift. The amplitude of accommodation decreased approximately 1.49D from 7.98D to 6.49D and this resulted from the prolongation of near point of accommodation. Near point of convergence also was prolongated from 9.45cm to 10.30cm after VDT work.

  • PDF

The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens (실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화)

  • Kim, So Ra;Kang, Byeong Ho;Jung, In Pil;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.381-388
    • /
    • 2012
  • Purpose: In this study, the changes in the shape of silicone hydrogel lenses, dryness of lens and objective/ subjective symptoms that could be induced by repeating dryness of lens and objective/subjective symptoms were investigated. Methods: After drying and rehydrating of silicone hydrogel lenses with different lens material and thickness for 4 times, their overall diameters and base curves were compared. Subjective symptoms, non-invasive tear break-up time (NIBUTs) and blinking rate were evaluated after wearing dehydrated silicone hydrogel lens. Results: Overall diameter and base curve increased in all tested silicone hydrogel lenses by repeating dryness and rehydration. The degree of change in over all diameter and base curve were variable on the material. There were irregular change of lens parameters in thicker lens. When the subjects wore silicone hydrogel lenses after drying and rehydrating, their NIBUTs were decreased and blink rates were increased regardless of lens material or thickness. In addition, repetitive drying of silicone hydrogel lenses affected the lens fitting. Therefore, subjective symptoms such as itching, pain, irritation, foreign body sensation, dryness tended to be increased. Conclusions: The results obtained from the study may suggest to develop durable silicone hydrogel contact lenses against dry environment since the changes in parameters of silicone hydrogel lens and the subjective discomfort were observed after repetitive drying and rehydration.

Air Pollution and Its Effects on E.N.T. Field (대기오염과 이비인후과)

  • 박인용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.6-7
    • /
    • 1972
  • The air pollutants can be classified into the irritant gas and the asphixation gas, and the irritant gas is closely related to the otorhinolaryngological diseases. The common irritant gases are nitrogen oxides, sulfur oxides, hydrogen carbon compounds, and the potent and irritating PAN (peroxy acyl nitrate) which is secondarily liberated from photosynthesis. Those gases adhers to the mucous membrane to result in ulceration and secondary infection due to their potent oxidizing power. 1. Sulfur dioxide gas Sulfur dioxide gas has the typical characteristics of the air pollutants. Because of its high solubility it gets easily absorbed in the respiratory tract, when the symptoms and signs by irritation become manifested initially and later the resistance in the respiratory tract brings central about pulmonary edema and respiratory paralysis of origin. Chronic exposure to the gas leads to rhinitis, pharyngitis, laryngitis, and olfactory or gustatory disturbances. 2. Carbon monoxide Toxicity of carbon monoxide is due to its deprivation of the oxygen carrying capacity of the hemoglobin. The degree of the carbon monoxide intoxication varies according to its concentration and the duration of inhalation. It starts with headache, vertigo, nausea, vomiting and tinnitus, which can progress to respiratory difficulty, muscular laxity, syncope, and coma leading to death. 3. Nitrogen dioxide Nitrogen dioxide causes respiratory disturbances by formation of methemoglobin. In acute poisoning, it can cause pulmonary congestion, pulmonary edema, bronchitis, and pneumonia due to its strong irritation on the eyes and the nose. In chronic poisoning, it causes chronic pulmonary fibrosis and pulmonary edema. 4. Ozone It has offending irritating odor, and causes dryness of na sopharyngolaryngeal mucosa, headache and depressed pulmonary function which may eventually lead to pulmonary congestion or edema. 5. Smog The most outstanding incident of the smog occurred in London from December 5 through 8, 1952, because of which the mortality of the respiratory diseases increased fourfold. The smog was thought to be due to the smoke produced by incomplete combustion and its byproduct the sulfur oxides, and the dust was thought to play the secondary role. In new sense, hazardous is the photochemical smog which is produced by combination of light energy and the hydrocarbons and oxidant in the air. The Yonsei University Institute for Environmental :pollution Research launched a project to determine the relationship between the pollution and the medical, ophthalmological and rhinopharyngological disorders. The students (469) of the "S" Technical School in the most heavily polluted area in Pusan (Uham Dong district) were compared with those (345) of "K" High School in the less polluted area. The investigated group had those with subjective symptoms twice as much as the control group, 22.6% (106) in investigated group and 11.3% (39) in the control group. Among those symptomatic students of the investigated group. There were 29 with respiratory symptoms (29%), 22 with eye symptoms (21%), 50 with stuffy nose and rhinorrhea (47%), and 5 with sore thorat (5%), which revealed that more than half the students (52%) had subjective symptoms of the rhinopharyngological aspects. Physical examination revealed that the investigated group had more number of students with signs than those of the control group by 10%, 180 (38.4%) versus 99 (28.8%). Among the preceding 180 students of the investigated group, there were 8 with eye diseases (44%), 1 with respiratory disease (0.6%), 97 with rhinitis (54%), and 74 with pharyngotonsillitis (41%) which means that 95% of them had rharygoical diseases. The preceding data revealed that the otolaryngological diseases are conspicuously outnumbered in the heavily polluted area, and that there must be very close relationship between the air pollution and the otolaryngological diseases, and the anti-pollution measure is urgently needed.

  • PDF

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

Changes in Objective and Subjective Responses in Soft Contact Lens Wearers Refitted to Daily-Wear Silicone Hydrogel Contact Lenses (매일착용 실리콘 하이드로겔렌즈로 바꿔 착용한 소프트 콘택트렌즈 착용자에서 나타난 증상 변화)

  • Lee, Koon-Ja;Mun, Mi-Young;Buyn, Jang-Won;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.43-54
    • /
    • 2007
  • Silicone hydrogel contact lenses developed as a continuous-wear modality are now used as a daily-wear contact lenses. The purpose of this study was to investigate the clinical performance in a group of successful long-term wearers of conventional hydrogel contact lenses when refitted with daily wear $O_2OPTIX$ silicone hydrogel lenses. Sixty-two wearers ($30.7{\pm}19.9$ months of prior lens wear) among sixty-five soft lens wearers refitted with $O_2OPTIX$ silicone hydrogel lenses were participated in this study finally. Subjective symptoms were scored and objective signs were graded using CCLRU scales during the study period. 98% of subjects were successfully refitted with the one base curve of $O_2OPTIX$, and 33.9% of subjects were needed more or less lens powers compared with their habitual lenses. Subjects reported a concurrent reduction in dryness, redness and tiredness compared with their habitual lenses and both subjective and objective evaluations showed that dryness, tiredness, itchiness, bulbar and limbal hyperemia were decreased and significantly decreased particularly for those subjects with greater baseline symptoms (p<0.0001). But corneal staining was increased and was seen in many subjects during the study (p<0.0001). Refitting existing soft contact lens wearers with silicone hydrogel contact lens could result in a decreased in dryness, redness and tiredness, particularly more effective for those subjects with greater baseline of those symptoms. When patients using conventional hydrogel materials switch to a silicone hydrogel material, the potential for increased corneal staining should be considered and over-refraction should be needed to give a best vision.

  • PDF