• Title/Summary/Keyword: 크라운

Search Result 228, Processing Time 0.027 seconds

Technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks (지르코니아 프레임워크를 이용한 시멘트 유지형 임플란트-지지 단일 크라운과 연결 크라운의 보철적 합병증)

  • You, Sang-Choon;Bae, Jung-Yoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.26-31
    • /
    • 2017
  • Purpose: This study was to assess clinically the success rates and technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks. Materials and methods: 75 (single crowns: 51, splinted crowns: 24) cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks which were restored in 67 patients were investigated for the evaluation of the success rates and technical complications. All restorations were cemented with temporary cement. Age, gender, restoration position, opposing teeth, restoration type were assessed as possible factors affecting technical complications. Results: During the mean observation period of 22.2 months, cumulative success rates of all restorations were 66.9 (73.2 - 60.6)%. Retention loss was found in 16 restorations (single crowns: 14, splinted crowns: 2), abutment screw loosening and veneer porcelain fracture were found in each 2 single crowns, respectively. According to a Kaplan-Meier survival analysis of single crowns and splinted crowns, the cumulative success rates were 58.9 (66.6 - 51.2)%, 87.5 (96.1 - 78.9)%, respectively. There was a statistically significant difference. The other possible factors did not have a significant effect on the technical complications. Conclusion: Retention loss was the most frequent technical complication. Abutment screw loosening and veneer porcelain fracture were found rarely in single crowns only. Age, gender, restoration position, and antagonist did not have significant effect on the technical complications. Splinted crowns had a higher success rate than single crowns.

Colorimetric Analysis of Preformed Zirconia Anterior Crowns for Esthetic Restoration (심미수복용 기성 지르코니아 크라운의 색조 평가)

  • Lee, Changkeun;Park, Kibong;Yang, Yeonmi;Lee, Daewoo;Kim, Jaegon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.318-327
    • /
    • 2019
  • The purpose of this study was to identify which combination of zirconia crowns and cements is most similar in color to the maxillary primary incisors by varying the color of zirconia crowns, crown thickness, and shade of cements. Prefabricated zirconia crowns in 3 shades and crowns fabricated using 6 types of zirconia blocks were used in this study. These were filled with A2-shade or translucent-shade resin cement and the $L^*$, $a^*$, and $b^*$ values were calculated using a spectrophotometer. The color differences between the natural teeth and the zirconia crowns were assessed. The shade of the final restoration was more similar to that of the natural teeth using A2-shade than translucent-shade resin cement. Application of A2-shade cement to a 0.5-mm-thick crown fabricated from a smile series 2 zirconia block resulted in the color most similar to that of the natural teeth. A2-shade resin cement is recommended for zirconia crown restoration in anterior primary teeth compared to TR-shade resin cement for more esthetic restoration. Since restorations with Nu-smile zirconia crowns were not esthetically favorable in terms of shade, improvement of the shade characteristics of the product or development of a new kind of zirconia crown is required.

업계취재 - 크라운상표의 조선맥주

  • Lee, Du-Hong
    • 방재와보험
    • /
    • s.23
    • /
    • pp.30-31
    • /
    • 1984
  • 4만8천여평의 광활한 대지위에 세워진 공장전체가 푸른 나무와 녹지로 둘러싸여 국내에서 가장 오래된 맥주공장 크라운의 이미지를 더욱 신선하게 해주고 있다. 서울특별시 영등포구 영등포동 640번지에 자리잡고 있는 조선맥주공장의 방재설비는 과연 어느 정도이며 오늘의 크라운맥주가 있기까지 반세기동안의 역정이 어떠했는지를 알아보기 위해 미리 약속을 하고 찾았다.

  • PDF

Comparison of Crown Shape and Amount of Tooth Reduction for Primary Anterior Prefabricated Crowns (유전치 기성 크라운의 형태 및 치질 삭제량 비교)

  • Kim, Soyoung;Lim, Youjin;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.64-75
    • /
    • 2019
  • The purpose of this study was to obtain instructions for size selection of prefabricated crown and tooth reduction by 3-dimensional analysis of the size and shape of the maxillary primary central and lateral incisors and prefabricated crowns (celluloid strip, resin veneered stainless steel, and zirconia crowns). The maxillary primary central and lateral incisors of 300 Korean children was scanned with three types of prefabricated crown to create standard three-dimensional tooth models and prefabricated crowns. The shapes of the prefabricated crowns and natural teeth were compared according to four parameters (mesio-distal width, height, labio-palatal width, and labial surface curvature coefficient) and calculated the amount of tooth reduction required for each prefabricated crown. The size 2 resin veneered stainless steel crown, size 1 zirconia crown, and size 2 celluloid strip crown were most similar in shape to the primary central incisor. The size 3 rein veneered stainless steel crown, size 2 zirconia crown, and size 3 celluloid strip crown were most similar to the primary lateral incisor. The amount of tooth reduction was similar in both maxillary primary central and lateral incisors. The incisal reduction was greatest for the zirconia crown. At the proximal surface, the zirconia and celluloid strip crowns required a similar amount of tooth reduction, but more than the resin veneered stainless steel crown. The labial surface reduction was greatest for the zirconia crown. The degree of lingual surface reduction was not significant among the three prefabricated crowns. Among the assessment parameters, mesio-distal crown width was the most important for choosing a prefabricated crown closest to the actual size of the natural crown.

A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models (한국 유치 모델에서 유전치 지르코니아 크라운의 형태계측학적 연구)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-56
    • /
    • 2018
  • The purpose of this study was to provide clinical recommendations for restoration with selection of the most similar zirconia crown by 3-dimensional analysis of the shape of the maxillary primary central and lateral incisors in Korean individuals and prefabricated zirconia crowns. The average shape of the sound maxillary primary central and lateral incisors in 300 children was reproduced by 3-dimensional scanning. Zirconia crowns of 4 manufacturers (NuSmile $ZR^{(R)}$ Crown, Cheng $Crowns^{(R)}$, Kinder $Krowns^{(R)}$, and EZ $Pedo^{(R)}$ Crown) were scanned 3-dimensionally, and coordinates for comparison of the shape were measured to evaluate the similarity between the teeth and crowns. The most similar crowns were selected by comparing the mesiodistal length, crown height, crown shape ratio, distance between the same coordinates of a tooth and crown, the radius of curvature of the labial surface, and the volume. As a result of analysis, Cheng $Crowns^{(R)}$ size 3 and NuSmile $ZR^{(R)}$ Crown size 2 were the most similar crowns in the maxillary primary central and lateral incisors, respectively. Scanning the inner surface of the crowns and evaluating the amount of tooth reduction required suggested that an overall lesser amount of tooth reduction compared to that presented by the manufacturer's guidelines should be performed.

Synthesis of New Bis-Crown Ether (Ⅱ) : Bis-Crown Ether with Siloxane Moiety (새로운 비스-크라운 에테르의 합성(제 2보) : 실옥산 사슬에 연결된 비스-크라운 에테르)

  • Chang, Seung Hyun;Kim, Jae Yong;Chung, Kwang Bo
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.9
    • /
    • pp.635-639
    • /
    • 1996
  • New bis-crown ether containing siloxane chain was synthesized. 1,3-Bis(trimethylsiloxy)-1,3-dimethyl-1,3-di(4'-ethylbenzo-18-crown-6) disiloxane (1) was synthesized by reaction of 4'-vinylbenzo-18-crown-6 with 1,3-bis(trimethylsiloxy)-1,3-dimethyl-1,3-disiloxane in the presence of Pt catalyst. 4'-Vinylbenzo-18-crown-6 was prepared through five-step reaction which started from the reaction of catechol and acetic anhydride.

  • PDF

Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image (PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.117-122
    • /
    • 2018
  • In this study, HU(hounsfield unit) value of CT generated by dental prosthesis was measured according to the type of metal when PET-CT was performed, and the degree of distortion and standard deviation of SUV(standard uptake value) and to propose a method to reduce errors in image reading. PET-CT was performed using actual teeth, metal crown, gold crown, titanium, and zirconia dental prosthesis. Compared with general teeth, the SUV value increased with increasing HU value. The SUV value of metal crown, titanium, and zirconia was increased by 37% and the gold crown increased by 45.4%. In addition, image distortions were small in general teeth, metal crown, titanium, and zirconia, but hard curing of the gold crown occurred and image distortion occurred. Therefore, since the metal type of the dental prosthesis affects the SUV value, the NAC(non attenuation correction) PET image of the dental prosthesis can be helpful in the diagnosis of the patient using the gold material.

Syntheses of Biologically Active Phosphinate Derivatives with a Pendant Monoazacrown Ether (모노아자크라운에테르 기능기를 가진 생리활성 포스피네이트 유도체의 합성)

  • Nam Chong-Woo;Chung Yeong-Jin;Yang Il-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.1
    • /
    • pp.154-161
    • /
    • 1993
  • Four kinds of new phosphinate derivatives with a pendant monoazacrown ether were synthesized and their biological activities were tested. These biologically active phosphinates were synthesized in relatively good yields (61∼72%) by one step reactions of phenylphosphinate with aldehyde and monoazacrown ether. Toxicity of these compounds was tested by intraperitoneal injection of the compounds to male mouse and revealed $LD_{50}$ value of 65∼90 mg/kg, which showed enhanced toxicity by attachment of a pendant azacrown ether to a simple phenylphosphinate structure. Although the ring size effect of the pendant crown ethers, (monoaza-15-crown-5 and monoazo-18-crown-6), beening negligible, the identity of the ester functional group in the phosphinate structure exerted sizable influence on toxicity. Thus, phosphinate derivative with octyl or propyl ester group showed somewhat higher toxicity than that with ethyl ester group.

  • PDF

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.