• Title/Summary/Keyword: 쿨러

Search Result 115, Processing Time 0.025 seconds

Comparisons of Performance with Heat Exchanger Constitution in the Fin-tube Gascooler (핀-관 가스쿨러에서 열교환기 구성에 따른 성능 비교)

  • Bae, Kyung-Jin;Shin, Eun-Sung;Hong, Myung-Suk;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1294-1299
    • /
    • 2009
  • Since the operating pressure of $CO_2$ gascooler is so high compared with that of previous subcritical condenser, the optimization of gascooler is needed for improve heat exchanger performance. In this study, the performance characteristics of five kinds of heat exchangers were analyzed and compared with operating conditions. As a result, the 4-20 HX-tube shows the maximum gascooler capacity because the heat transfer is effective and pressure drop is small. Beside, the high performance of 4-20 HX-tube could be keep for wide operating condition.

  • PDF

Simulation Study on the Performance Characteristics of $CO_2$ microchannel gascooler with Operation Conditions ($CO_2$용 마이크로채널 가스쿨러의 운전조건 변화에 따른 성능특성에 관한 해석적 연구)

  • Shin, Eun-Sung;Bae, Kyung-Jin;Kim, Byeong-Cheol;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1090-1095
    • /
    • 2009
  • The purpose of this study is to determine the performance characteristics for the micro-channel gascooler with various operating conditions. The performance of four kind of HX models were analyzed and optimized with the variation of refrigerant inlet temperature, air velocity, outdoor temperature. As a result, Model B showed the maximum capacity and high performance could be maintained for wide operating conditions. Beside, the micro-channel heat exchanger could be appled to $CO_2$ system appropriately because of a small pressure drop and high heat transfer rate.

  • PDF

Thermal Analysis of Compact Circular Water Cooled Engine Oil Cooler (고집적 원통형 수냉식 엔진 오일쿨러의 열적 해석)

  • 윤준규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.771-781
    • /
    • 1998
  • A highly compact and thermally efficient water cooled oil cooler for automotive use without offset strip fin and casing is developed in this study. The study result has shown that eliminating the fin and casing in the oil cooler the manufacturing process and cost and can be simplified and reduced greatly without sacrificing the thermal capacity. The oil cooler developed in the study uses the dimply type heat transfer core element design instead of offset strip fin and eliminates the outer casing for coolant water flow by applying specially made parallel loop flow design. In the study the thermal design program for the present oil cooler also was developed and validated experimentally.

  • PDF

Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System (오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계)

  • Byun, J.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.

Experimental Study on Heat Transfer Performance of Oil Cooler (오일 쿨러의 열전달 성능에 관한 실험적 연구)

  • Cho, Dong-Hyun;Lim, Tae-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2328-2333
    • /
    • 2008
  • The experimental study was carried out to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube heat exchanger with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. Mass flow rate was varied from 1.2 to $6.0\;m^3/h$ for oil and from 0.6 to $3.0\;m^3/h$ for cold water, respectively. From the experiment of shell-and-plate finned tube heat exchanger, the shell side heat transfer coefficient of heat exchanger with 9 tubes was compared with that of 13 and 19 tubes. It was found that the heat exchanger with 9 plate finned tubes showed more performance of heat transfer than that of 13 and 19 tubes.

  • PDF

Analysis on the Thermal Performance of an Ammonia Unit Cooler (암모니아 유니트 쿨러의 열성능 해석)

  • 최재광;김무근;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

A study on a uniformity of flow field in a duct cooler of FGD system (배연탈황설비 덕트쿨러에서의 유동균일화에 관한 연구)

  • 배진효;김광추;박만흥;박경석;이종원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.120-130
    • /
    • 2000
  • A flow uniformity in a duct cooler of duct system of FGD(Flue Gas Desulfurization) linking a reheater and a absorber has been investigated in the present study. For this purpose, the flow characteristics according to the geometry of a vertical and horizontal vane in a curved duct of the duct system has been examined with the aid of a numerical simulation. The results indicate that the vertical vane with a little deflection toward a recirculation region makes the flow distribution in the duct cooler more uniform than that without deflection, and horizontal vane does not effect the change of the flow distribution for an angle of inclination. The mean flow uniform factor shows its maximum for duct system without the vane(case NP) and its minimum for the vertical vane with a little deflection(case P-0.8-0) .

  • PDF

$CO_2$ 냉매용 가스쿨러의 열전달 특성

  • 장영근;강병하
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.7
    • /
    • pp.24-28
    • /
    • 2002
  • 1987년의 몬트리얼 의정서에 의한 CFCs와 HCFCs의 규제에 이어 1999년의 교토의정서에 의한 지구온난화 물질에 대한 규제는 CFCs와 HCFCs의 대체물질로 준비되어온 HFCs의 사용에 제동을 걸게 되었다. 아울러 환경론자들은 냉동공조 업계가 HFCs를 사용하지 말고 탄화수소, 이산 화탄소, 암모니아, 물 및 공기와 같은 보다 환경친 화적인 자연냉매를 사용할 것을 요구하고 있으며, 최근 학계의 자연냉매에 대한 고무적인 연구결과는 자연냉매의 사용에 대한 산업계의 관심을 고조 시키고 있다. 본 고에서는 최근 주목을 받고있는 이 산화탄소를 냉매로 하는 냉방시스템 중의 한 요소인 가스쿨러에 대한 연구개발 현황분석 및 향후 과제에 대하여 살펴보기로 한다.

  • PDF

Evaluation of Structural Integrity about Structural Design for Internal Components of Aircraft Engine (항공기 엔진 구성품 내부 구조 설계에 대한 구조 안전성 평가)

  • Hyunbum Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.58-62
    • /
    • 2023
  • In this work, the structural integrity was investigated of the structural design results of internal components for the aircraft engine. The radiator and intercooler were combined with the internal components of the engine. Therefore, the safety of the radiator and intercooler was investigated during flight conditions. The structural integrity was evaluated through structural analysis, using the finite element analysis method. The acceleration load for structural design and analysis was considered. The structural safety evaluation found the structural design results to be valid.