• Title/Summary/Keyword: 쾌적설정온도

Search Result 21, Processing Time 0.023 seconds

Evaluation of Thermal Comfort during Sleeping in Summer - Part IV : Study on Indoor Temperature Conditions for Comfort Sleep - (여름철 수면시 온열쾌적감 평가 - 제4보 : 쾌적수면을 위한 실내온도 설정에 관한 연구 -)

  • Kum, Jong-Soo;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.307-312
    • /
    • 2007
  • This study was performed to evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of sleep efficiency and MST under four thermals conditions ($22^{\circ}C,\;24^{\circ}C,\;26^{\circ}C,\;30^{\circ}C$). Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. Their age was from 20 to 22 years old. They were healthy, and had regular sleep with consistent bed and wakeup time. It was checked whether they had a good sleep before the night of experiment. Experiments were performed in an environmental chamber using thermo-hygrostat. The physiological signal (EEG) for sleep stage were obtained from C3-A2 and C4-Al electrode sites. Sleep stages were classified, then SWS latency and SWS/TST were calculated for the evaluation for sleep efficiencies on thermal conditions. As results, mean skin temperature for comfort sleeping was $34.5{\sim}35.4^{\circ}C$. Considering sleep efficiency and mean skin temperature, indoor room temperature of upper limit was $28.1^{\circ}C$.

Optimal Control Strategies for Energy Saving of Central Cooling System with Outdoor Air Temperature Changes (외기온도 변화특성을 고려한 중앙냉방시스템의 에너지 절감 최적제어에 관한 연구)

  • Park, Ki-Tae;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4260-4266
    • /
    • 2015
  • In this study, the optimal control method for minimizing of energy consumption for central cooling system with proper occupant comfort level is researched by simulation. The optimal control method is that the optimal set temperatures such as the condenser water temperature, supply air temperature, and chilled water temperature with environment variable change such as outdoor air dry-bulb and wet-bulb temperatures are obtained by suggested optimal control algorithm with maximum and part building load. The TRNSYS program is used for system modeling and the control performances with the suggested optimal control method are compared with the existing control method of fixed set points. The suggested optimal control method shows better responses in energy consumption in comparison with existing control ones.

Effects of Ondol Sleep Environment on the Thermo-physiological Response of the Human Body (온돌 수면환경이 인체의 온열생리반응에 미치는 영향)

  • Kim, Jung-Sook;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1999
  • The purpose of this study was to investigate actual sleeping environments in Ondol rooms depending on the season. The experiment was performed on five healthy women. The bedroom environments using Ondol were measured in five cases (three apartments and two houses). The environments in bedroom, bedding temperature, skin temperature and thermal sensation were measured continuously through the seven days for each season in real life. This data of sleeping environments were analyzed in the view of seasonal variations and housing types. Annual average bedroom temperatures: $26.2{\sim}31.0^{\circ}C$ in apartments, $15.7{\sim}33.6^{\circ}C$ in houses. Annual average bedroom humidity: 48.3~82.1% RH in apartments, 64.9~87.0% RH in houses. During sleeping, temperatures of contact surfaces like sheets and under quilts ranged between $30.5^{\circ}C$ and $34.1^{\circ}C$ regardless of season or housing type. Annual average rectal temperature was $36.8^{\circ}C$ with no significant difference in season or housing type. In the point of thermal sensation, neutral temperature of the bedroom was $25.9^{\circ}C$ in apartments and $20.3^{\circ}C$ in houses. It was concluded that in spite of thermal environmental variations according to the seasons, skin, bedding and bedroom temperatures in apartments were better and more stable than those of houses. It is regarded that while houses are brick structured, apartments are steel-frame structured. Due to better insulation and air tightness, apartments were affected less from outdoor temperature and maintained higher room temperature than houses.

  • PDF

A Comparative Study of Characteristic on Far-infrared Radiation Heater and the Existing Heater (기존의 전기난방기와 원적외선 복사난방기의 특성 연구)

  • Hur, Dong-Ryol;Lee, Kwang-Seong;Kim, Yong-Ha;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1255-1256
    • /
    • 2007
  • 전도, 대류, 복사 방식의 열전달 방식중에서 복사방식이 가장 효율적이고 쾌적한 난방이라는 것은 기존의 연구에서도 잘 알려진 사실이다. 본 연구에서 제안한 천장형 원적외선 복사난방 방식은 같은 면적에서 같은 전력을 투입하였을 때, 설정온도 도달시간이 기존의 전기 난방기 보다 약 $10{\sim}20$분 빠르게 도달함을 알 수 있으며, 그만큼 에너지절약이 된다는 것을 알 수 있었다.

  • PDF

A Study on the Establishment of the Optimal Temperature Limits for Man's Thermal Comfort in an Asymmetric Radiant Space (불균등 복사공간의 쾌적온도범위 설정에 관한 연구)

  • Sohn, Jang-Yeul;Kong, Sung-Hoon;Yun, Yong-Jin
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.187-199
    • /
    • 1985
  • The low-temperatured radiant heating System like a panel heating system is recognized as nice means to make comfortable indoor environment. Perhaps, 'Ondol' would be a typical example of the Panel heating system. Nevertheless. Occupants in a radiantly heated Space which has an asymmetric radiant field may feel thermally discomfort due to the asymmetric radiation. The aim of this Study is to suggest the fundamental technical data for establishing Standards of thermally comfortable environment when designing a radiant heating System. Thermal distribution of indoor environment and the skin temperature of the occupants were measured at experimental room in KIER (Korea Institute of Energy and Resources). Whole/Regional thermal and comfort Sensation votes of the occupants were taken simultaneously in order to investigate the relationships between thermal environmental factor and the occupants' responses. The effect of an asymmetric radiation on thermal environment and the occupants' responses was analyzed by using a v.r.t.(vector radiant temperature). By this means, the thermally neutral limits for the ambient air temperature and the floor surface temperature by the occupants' responses were Obtained. And the recommended temperature limits of the indoor surface were derived from the experimental work and the theory of radiant and will provide thermal neutrality for man without any discomfort on the part of the body.

  • PDF

Air-conditioning and Heating Time Prediction Based on Artificial Neural Network and Its Application in IoT System (냉난방 시간을 예측하는 인공신경망의 구축 및 IoT 시스템에서의 활용)

  • Kim, Jun-soo;Lee, Ju-ik;Kim, Dongho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.347-350
    • /
    • 2018
  • In order for an IoT system to automatically make the house temperature pleasant for the user, the system needs to predict the optimal start-up time of air-conditioner or heater to get to the temperature that the user has set. Predicting the optimal start-up time is important because it prevents extra fee from the unnecessary operation of the air-conditioner and heater. This paper introduces an ANN(Artificial Neural Network) and an IoT system that predicts the cooling and heating time in households using air-conditioner and heater. Many variables such as house structure, house size, and external weather condition affect the cooling and heating. Out of the many variables, measurable variables such as house temperature, house humidity, outdoor temperature, outdoor humidity, wind speed, wind direction, and wind chill was used to create training data for constructing the model. After constructing the ANN model, an IoT system that uses the model was developed. The IoT system comprises of a main system powered by Raspberry Pi 3 and a mobile application powered by Android. The mobile's GPS sensor and an developed feature used to predict user's return.

  • PDF

An Application of Satellite Image Analysis to Visualize the Effects of Urban Green Areas on Temperature (위성영상을 이용한 도시녹지의 기온저감 효과 분석)

  • Yoon, Min-Ho;Ahn, Tong-Mahn
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.46-53
    • /
    • 2009
  • Urbanization brings several changes to the natural environment. Its consequences can have a direct effect on climatic features, as in the Urban Heat Island Effect. One factor that directly affects the urban climate is the green area. In urban areas, vegetation is suppressed in order to accommodate manmade buildings and streets. In this paper we analyze the effect of green areas on the urban temperature in Seoul. The period selected for analysis was July 30th, 2007. The ground temperature was measured using Landsat TM satellite imagery. Land cover was calculated in terms of city area, water, bare soil, wet lands, grass lands, forest, and farmland. We extracted the surface temperature using the Linear Regression Model. Then, we did a regression analysis between air temperature at the Automatic Weather Station and surface temperature. Finally, we calculated the temperature decrease area and the population benefits from the green areas. Consequently, we determined that a green area with a radius of 500m will have a temperature reduction area of $67.33km^2$, in terms of urban area. This is 11.12% of Seoul's metropolitan area and 18.09% of the Seoul urban area. We can assume that about 1,892,000 people would be affected by this green area's temperature reduction. Also, we randomly chose 50 places to analysis a cross section of temperature reduction area. Temperature differences between the boundaries of green and urban areas are an average of $0.78^{\circ}C$. The highest temperature difference is $1.7^{\circ}C$, and the lowest temperature difference is $0.3^{\circ}C$. This study has demonstrated that we can understand how green areas truly affect air temperature.

NIR reflecting properties of TiO2/Ag/TiO2 multilayers deposited by DC/RF magnetron sputtering (DC/RF 마그네트론 스퍼터링법을 이용한 TiO2/Ag/TiO2 하이브리드 다층박막의 적외선 반사 특성)

  • Kim, Seong-Han;Kim, Seo-Han;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.158-158
    • /
    • 2016
  • 최근 화석연료의 고갈과 환경 보전 및 에너지 절약에 대한 관심이 높아짐에 따라 화석연료의 소비를 최소화하고 실내조건을 쾌적하게 유지하려는 연구가 진행되고 있다. 국내의 경우 전체 에너지 소비의 30%이상을 차지하고 있는 건물부문에서의 에너지 소비를 줄이기 위한 활발한 연구가 진행되고 있으며 이에 따른 에너지절약 소재개발이 활발하게 진행되고 있다. 1975년 이후 여러 차례에 걸친 단열강화 조치를 통해 건물에서의 에너지 소모를 줄이고 있었으나 건물의 외벽에 대한 사항으로 한정되어있었고, 또한 건물의 창 면적이 증가함에 따라 창을 통한 열손실량과 열획득량이 더욱 증가하게 되었다. 이러한 문제를 해결하기 위해 열반사유리에 대한 많은 연구가 진행되고 있다. 열반사유리는 근적외선(열선)영역의 빛을 반사시켜 실내의 열손실량 및 외부에서의 열획득량을 감소시켜 에너지의 소비를 줄일 수 있는 유리을 말한다. 이러한 열반사유리은 fresnel 방정식을 통해 빛의 파장대에 따른 반사율 및 투과도를 예측할 수 있는데, 다층박막구조인 Oxide-Metal-Oxide(OMO)구조는 Oxide의 높은 굴절률과 Metal의 낮은 굴절률을 통해 가시광영역대의 높은 투과도와 근적외선 영역의 높은 반사율을 얻을 수 있다. 또한 Metal층을 삽입함으로서 flexible한 코팅이 가능하고, 높은 carrier density와 mobility로 표면 플라즈몬 공명을 통해 특정 파장대의 반사율을 높일 수 있으므로 많은 연구가 진행되고 있다. $TiO_2$는 고굴절률 및 낮은 광흡수성의 특성을 가지는 산화물반도체로 기존의 $In_2O_3$계 산화물에 비해 값이 싸고 높은 안정성과 광촉매특성을 보이므로 외부에 노출된 환경에 적합한 재료이다. Ag는 저굴절률과 낮은 광흡수성을 가지는 재료로 금속층에 적합하다. 본 연구에서는 fresnel 방정식을 통해 반사도 및 투과도를 예측하고 마그네트론 스퍼터링법으로 다층박막을 열선인 적외선 영역에서의 반사율 및 반사 효율을 평가하였다. Index-matching 시뮬레이션을 통해 $TiO_2/Ag/TiO_2$ 다층박막의 투과도와 반사도를 이론적으로 검토하였다. 시뮬레이션 프로그램은 Macleod프로그램을 이용하였고 재료 각각의 굴절률은 Ellipsometry를 이용하여 측정하였다. 두께 40 nm 와 8 ~ 16 nm를 가지는 $TiO_2$층과 Ag층을 각각 RF/DC 마그네트론 스퍼터링법을 이용하여 Glass기판 위에 증착하였다. 직경 3 in 의 $TiO_2$, Ag 소결체 타깃을 이용하였고 스퍼터링 파워는 각각 200 W, 50 W로 설정하였고, 스퍼터링 가스는 Ar가스의 유량을 20 sccm으로 설정하였다. 작업압력은 모두 1 Pa로 설정하였고 타깃 표면의 불순물 및 이물질 제거를 위해 Pre-sputtering을 10분 진행하였다. 박막의 두께는 reflectometer와 Alphastep을 이용하여 측정하였고 Hall effect measurement를 이용하여 비저항, carrier density, mobility등 전기적 특성을 측정하였다. 또한 UV-VIS spectrometer와 USPM-RU-W NIR Micro-Spectrophotometer를 통해 광학적 특성을 측정하였고 계산 값과 비교분석하였다. 또한 열반사 특성을 평가하기 위해 직접 set-up한 장비를 이용하였다. 단열 박스에 샘플을 장착해 적외선 램프를 조사하였을 때의 열 반사효율을 평가하였고, IR Camera를 이용하여 단열 박스 내부의 온도 변화를 관찰하였다.

  • PDF

Suitability of Setting Summer Indoor Temperature for Thermal Comfort (여름철 실내 쾌적온도 설정 기준의 적합성)

  • Shim, Huen Sup;Jeong, Woon Seon
    • The Korean Journal of Community Living Science
    • /
    • v.24 no.4
    • /
    • pp.583-589
    • /
    • 2013
  • This study was to provide the information for optimum utilization of the air-conditioning system in the human health and energy saving perspective. Subjects were 17 male and female college students(7 males and 10 females) with normal weight. They wore a short sleeved shirt, knee length trousers, socks, and underwear(0.4clo). They were asked to choose the preferred temperature from different environmental temperatures($28^{\circ}C$, $25^{\circ}C$). The physiological responses were measured and the subjective sensation was voted during the step changes of environmental temperature, starting at $28^{\circ}C$ to $25^{\circ}C$ with $1^{\circ}C$ decrease every 20 minutes. The preferred temperature was $25.9{\pm}0.4^{\circ}C$ for males and $26.9{\pm}0.2^{\circ}C$ for females at $28^{\circ}C$ and $24.8{\pm}0.6^{\circ}C$ for males and $25.6{\pm}0.1^{\circ}C$ for females at $25^{\circ}C$. The preferred temperature decreased about $1.3^{\circ}C$ while the environmental temperature changed $3^{\circ}C$. During the environmental step changes, mean skin temperature decreased more in females while the oxygen uptake and rectal temperature were kept constant for both males and females. We found the preferred temperature was affected by the exposed temperature and the thermal sensation in the condition. Subjects preferred a lower environmental temperature when they were exposed to a lower temperature with cooler sensation. Therefore, in the perspective of human health and energy saving, it is recommended to start setting the air-conditioning temperature higher than the preferred temperature.

A Study on Changes in Feed Digestibility and Establishment of Energy Requirement for Maintenance of Growing Hanwoo Steers under Severe Heat Stress (심각한 열스트레스에 의한 육성기 거세한우의 사료 소화율 변화 탐색 및 유지를 위한 에너지 요구량 설정 연구)

  • Cho, Yu Kyung;Choi, Seong Ho;Han, Ouk Kyu;Park, Joung Hyun;Choi, Chang Weon
    • Journal of agriculture & life science
    • /
    • v.50 no.5
    • /
    • pp.163-172
    • /
    • 2016
  • Four growing Hanwoo cattle weighing 200±11.7kg were used within 4×4 Latin square design to establish nutrient requirements for Hanwoo growing steers under severe heat stress. The steers were fed four different energy level diets; 100%(control), 100%(E100), 115%(E115) and 130%(E130) of energy levels of growing Hanwoo steers based on total digestible nutrient level suggested by the Korea Feeding Standard for Hanwoo using timothy hay and commercial concentrate. The steers in the control were housed with no stress, whereas the steers in the other groups were under severe heat stress. The severe heat stress significantly decreased(p<0.05) true digestibility of dry matter(i.e. control 81.5% vs E100 79.1, E115 77.0 and E130 76.0, respectively). The severe heat stress and different energy intake levels did not affect blood physiological metabolites and body temperature of the growing steers. Based on changes in average daily gain by different energy intake level, the equation(Y=0.235X+115.03) of energy requirement of growing Hanwoo steers without changes in body weight was calculated, indicating that, compared with the present energy intake suggested by Korean feeding standard, 15.03% of dietary energy for maintenance of growing Hanwoo steers under severe heat stress should be increased.