• Title/Summary/Keyword: 콘크리트 표면

Search Result 983, Processing Time 0.025 seconds

Evaluation on the Performance of Surface Performance Improving Agent for the Deterioration Prevention of Concrete Structures (콘크리트 구조물의 열화방지를 위한 표면 성능 개선제의 성능 평가)

  • Ryu, Gum-Sung;Koh, Kyoung-Taek;Kim, Do-Gyeum;Lee, Jang-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.177-186
    • /
    • 2005
  • The latest concrete structure has showed that the deterioration of durability has been increased by the damage from salt, carbonization, freezing & thawing and the others. Therefore, the measures for the concrete which has deteriorated durability have been taken. Among them, it has been often used that surface treatment which cuts off the deterioration factors of durability by protecting the surface of concrete. However, troubles such as fracture and rupture in the repair layer have been reported as time goes by due to the difference between the organic repair material like epoxy and concrete properties. Researchers have been developing the repair material which can cut off the deterioration factors of durability such as $CO_2$ gas, chloride ion and water by making the formation of concrete elaborate through the reaction with calcium ion when the surface improving agent is coated on the concrete. The main ingredient of that is inorganic substance which is the same as the concrete property. This study was evaluated the surface improving agent for permeability, watertightness, air-permeability, chemical resistance and elution resistance. As a result, it has been reported that the surface improving agent improves watertightness and air-permeability by penetration more than 10mm within concrete. Therefore, it is concluded that the surface improving agent developed in this research prevents deterioration of concrete durability when it is coated on the concrete structure.

The Influence of Nano Synthesized Polymer Paint on Durability of Concrete (나노합성 무기질 폴리머계 표면처리제가 콘크리트의 내구성에 미치는 영향)

  • Beak, Jong-Myeong;Park, Youg-Keol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.56-63
    • /
    • 2016
  • This experiment was compared and analyzed between the original surface paint through chloride penetration, neutralization, freeze-thaw and chemical corrosion resistance measuring internal structure and volume of voids in order to evaluate the effect of increase in durability of the newly modeled nano synthesized polymer paint painted on concrete surface which results improvement on air permeability to increase the durability of concrete structures. The test result of measuring volume of void and inner structure, concrete, spreaded with nano synthesized polymer paint, showed decreasing trend of pore volume in the range of less than $0.1{\mu}m$ and more than $0.3{\mu}m$. Also, using an electron microscope inside showed tightness of hydration texture. Chloride penetration depth of concrete, painted with nano synthesized polymer paint, was decreased more than 92% compared to non-painted concrete and 70% with water-based epoxy painted concrete. Especially, chemical corrosion resistance test set with aqueous solution of 5% sulfuric acid, non-painted concrete and water-based epoxy painted concrete showed weight loss of 4% after dipping for 12 days. On the other hand, concrete painted with nano synthesized polymer paint showed 1.7% weight loss under the same condition. Also, it showed great result of appearance under the criteria of Tsivilis et al.

Effect of Concrete Surface Coating on the Service Life Extension (콘크리트 표면도장에 의한 내구수명 연장효과)

  • Kim, Ki-Hyun;Cha, Soo-Won;Jang, Seung-Yup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.193-194
    • /
    • 2010
  • Developed is a chloride penetration analysis program that can consider a concrete surface coating. The effect of concrete surface coating on the service life is simulated by the developed finite element program. It was revealed that the coating at the earlier age is the more effective way to extend the service life.

  • PDF

Detection of Concrete Slab Surface Cracks using Fuzzy Method and Brightness (퍼지 기법과 명암도를 이용한 콘크리트 표면의 균열 검출)

  • Kim, Jun-Hoi;Kim, Kwang-Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.173-175
    • /
    • 2010
  • 본 논문에서는 콘크리트 표면에 발생한 균열의 미세한 부분까지 효과적으로 검출 할 수 있는 방법을 제안한다. 제안된 균열 검출 방법은 콘크리트 영상의 RGB값을 퍼지 기법에 적용하여 후보 균열 영역을 검출한다. 검출된 후보 균열 영역에서 밀도와 명암도를 이용하여 효과적으로 세부적인 잡음까지 제거한 후, 최종으로 균열 영역을 검출한다. 실제 콘크리트 표면의 균열 영상을 대상으로 실험한 결과, 제안된 방법이 기존의 방법보다 균열의 검출 성능이 개선되었음을 확인할 수 있었다.

  • PDF

Analysis for Chloride Penetration in Concrete under Deicing Agent using Multi Layer Diffusion (다층구조확산을 고려한 제설제에 노출된 콘크리트의 염화물 해석)

  • Seo, Ji-Seok;Kwon, Seung-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.4
    • /
    • pp.114-122
    • /
    • 2016
  • Concrete is cost-benefit and high-durable construction material, however durability problem can be caused due to steel corrosion under chloride attack. Recently deicing salt has been widely spread in snowing season, which accelerates micro-cracks and scaling in surface concrete and the melted deicing salt causes corrosion in embedded steel. The previous governing equation of Fick's 2nd Law cannot evaluate the deteriorated surface concrete so that another technique is needed for the surface effect. This paper presents chloride penetration analysis technique for concrete subjected to deicing salt utilizing multi-layer diffusion model and time-dependent diffusion behavior. For the work, field investigation results of concrete pavement exposed deicing salt for 18 years are adopted. Through reverse analysis, deteriorated depth and increased diffusion coefficient in the depth are evaluated, which shows 12.5~15.0mm of deteriorated depth and increased diffusion coefficient by 2.0 times. The proposed technique can be effectively applied to concrete with two different diffusion coefficients considering enhanced or deteriorated surface conditions.

Temperature Patterns in Concrete Pavements at Very Early Ages (콘크리트 도로 포장의 초기 온도 분포 분석)

  • Kim, Seong-Min;Nam, Jeong-Hee
    • International Journal of Highway Engineering
    • /
    • v.7 no.3 s.25
    • /
    • pp.79-91
    • /
    • 2005
  • The temperature patterns in Portland cement concrete (PCC) pavements were measured and comprehensively analyzed from the beginning of the concrete placement based on the temperature measurement technique developed using innovative and inexpensive temperature measurement sensors. The temperature measurements in PCC pavements were taken at several different locations forvarious slab thicknesses. The concrete temperature patterns in the vertical and longitudinal directions of the pavement were analyzed and the effects of the pavement surface reflectivity, shading, and covering on the concrete temperatures were evaluated. The results of this study showed that the significant differences in the maximum concrete temperatures on the placement day were observed according to the concrete placement time. Since the zero-stress temperature is a function of the maximum concrete temperature on the placement day, the placement time would be an important factor that affects the behavior and performance of concrete pavements. The surface conditions of the pavement, such as the surface color, shading, and covering also affected the temperature patterns in PCC pavements significantly.

  • PDF

A Study on the Optimum Mix and Exposing Method of the Fine-Size Exposed Aggregate PCC Pavements (소입경 골재노출콘크리트포장의 최적 배합 및 노출기법에 관한 연구)

  • Kim, Young-Kyu;Lee, Seung-Woo;Yoo, Tae-Seok;Kim, Hyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.1-15
    • /
    • 2009
  • Surface of exposed aggregate concrete pavements is consists of exposed coarse aggregate by removing upper 2$\sim$3mm mortar of concrete slab. Exposed aggregate concrete pavements have advantages of maintaining low-noise and adequate skid-resistance level during the performance period. In order to provide the successful exposed concrete aggregate pavement, uniform distribution of the coarse aggregate on pavement surface through adequate the mix design and exposing method. The mix design in concrete pavement is generally designed on the basis of strength, but mix design of exposed aggregate pavement employed in this study includes the consideration of noise and skid resistance, as well as strength. Smaller of maximum coarse aggregate is known to be effective for reduce noise level. Optimum mix design and exposing method of fine-size exposed aggregate portland cement concrete pavement that can reducing the noise and maintain the adequate level of skid resistance are proposed in this study. To consider the variation of optimum exposing time due to the hardening speed of mortar by climatic condition, quantitative is also suggested measurement of hardening state.

  • PDF

Selection of Concrete Surface Impregnant through Durability Tests (내구성 실험을 통한 최적 표면침투제의 선정)

  • Kwon, Seung-Jun;Park, Sang-Sun;Lee, Sang-Min;Kim, Jong-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.77-86
    • /
    • 2007
  • The repair technique utilizing surface impregnant is widely used due to its simple construction procedures and economical benefit. Surface protection through this reparing technique cannot increase the bearing capacity of concrete members much but increase the durability performance and service life efficiently. In this study, fundamental tests such as water suction and permeation are performed for concrete specimens with several organic/inorgarnic impregnant and suitable impregnant is selected on the basis of the results. Finally, durability tests such as carbonation, freezing and thawing, and chloride attack are carried out for the concrete specimens with selected impregnant and it is experimentally verified that they have good resistance to deteriorations.

Cracks Detection of Concrete Slab Surface Using ART2-based Quantization and Gary Brightness Variation (ART2 기반 양자화와 명암도 변화를 이용한 콘크리트 슬래브 표면의 균열 검출)

  • Lee, Hoon-Seok;No, Dae-Kyeung;Woo, Young-Woon;Kim, Kwang-Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.379-385
    • /
    • 2008
  • 콘크리트 건물의 보수 작업은 표면에 발생하는 균열을 정확하게 계측함으로써 비용적인 측면과 안전성이 결정된다. 하지만 표면에 발생한 균열은 대부분 점검자에 의해 수작업으로 계측되기 때문에 시간적 측면에서 비효율적이다. 따라서 본 논문에서는 콘크리트 슬래브 표면에 발생한 균열의 밝기와 밀도 그리고 면적 특징을 이용한 균열 검출 기법을 제안한다. 제안된 균열 검출 방법은 콘크리트 슬래브 표면의 명암도와 위치 정보를 ART2 기반 양자화에 적용한 후, 균열과 인접한 배경간의 명암도 차이를 이용하여 균열과 인접한 배경을 분리한다. 균열과 인접한 배경이 분리된 영상에서 형태학적인 정보를 이용하여 세부적인 잡음을 제거한 후에 최종적으로 균열 영역을 검출한다. 실제 콘크리트 균열 영상을 대상으로 실험한 결과, 다양한 콘크리트 균열 영상에서 기존의 방법보다 균열 검출 성능이 개선되었음을 확인하였다.

  • PDF

Analysis on the Interfacial Bond-Slip Relationship between ear Surface-Mounted FRP Plate and Concrete (콘크리트내 표면매입 보강된 FRP 판과 콘크리트 사이의 착-미끄러짐 관계 해석)

  • Seo, Soo-Yeon
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.79-86
    • /
    • 2014
  • In this paper, a stress transfer mechanism between near surface-mounted (NSM) fiber reinforced polymer (FRP) plate and concrete was investigated and a reliable analytical procedure for it was presented by using bilinear bond-slip model simulating the bond behavior of NSM FRP plate. As a result, critical values in the bi-linear model such as maximum shear strength, slip at that time and failure slip at the initiation of softening de-bonding were suggested for being used in the differential equation considering he interfacial characteristic between NSM FRP and concrete. Also, it was found that the bond-slip behavior could be suitably redicted by using the proposed procedure even in the case of various bond lengths from the comparison with bond test result.