A Study on the Estimation of Setting Time for High Strength Concrete Using Durometer (개량형 Durometer를 이용한 고강도 콘크리트의 응결시간 추정 가능성 분석)

  • Sin, Se-Jun;Han, Soo-Hwan;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.87-88
    • /
    • 2020
  • The purpose of this study is to explore the possibility of estimating optimum surface finish time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Penetration resistance test and hardness test by Durometer. Penetration resistance tester and improved Durometer are similar, but the higher the temperature, the higher the setting time, and the higher the correlation was shown. When the hardness value of the improved Durometer is about 50 HD, it is found that the initial and 80 HD represent the end. It is expected that this will be useful in determining the finish time of the surface at the actual site.

  • PDF

A Study on the Estimation of Setting Time for Concrete Using Durometer (개량형 Durometer를 이용한 콘크리트의 응결시간 추정 가능성 분석)

  • Sin, Se-Jun;Han, Soo-Hwan;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.169-170
    • /
    • 2020
  • The purpose of this study is to explore the possibility of estimating optimum surface finish time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Penetration resistance test and hardness test by Durometer. Penetration resistance tester and improved Durometer are similar, but the higher the temperature, the higher the setting time, and the higher the correlation was shown. When the hardness value of the improved Durometer is about 50 HD, it is found that the initial and 80 HD represent the end. It is expected that this will be useful in determining the finish time of the surface at the actual site.

  • PDF

Setting Time Prediction of Super Retarding Concrete Using Improved Durometer (개량형 듀로미터를 이용한 초지연 콘크리트의 응결시간 분석)

  • Han, Soo-Hwan;Choi, Yoon-Ho;Yeun, Kyu-Won;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.73-74
    • /
    • 2020
  • In this study, the feasibility of the durometer into super retarding concrete was studied by comparing the penetration resistance with the hardness of each durometer using the penetration resistance and the improved Durometer and Durometer A-Type according to the ultra-delay mixture rate. The test results showed that initial setting time by improved Durometer and Durometer A-Type were fixed at 25, 50 HD, respectively, and the 35, 80 HD showed at final setting time. It was also found that the use of the durometer can be available to measure the setting time of the concrete.

  • PDF

The Quality Properties of Mortar for Using Tailings from the Sangdong Tungsten One as Admixture for Concrete (상동광산 광미를 콘크리트용 혼화재료로 사용하기 위한 모르타르의 품질특성)

  • Choi Yun-Wang;Jung Moon-Young;Jung Myung-Chae;Koo Gi-Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.383-390
    • /
    • 2004
  • This study has focused on the possibility for recycling tailings from the Sangdong tungsten mine as admixture for concrete. The XRD(X-ray diffraction analysis) and PSA(Particle size analysis) were performed to find mineralogical characteristics. As a result of XRD analysis, the tailings from the Sangdong tungsten fine were composed of quartz, chlorite, anorthite and cordierite etc. As a result of KSLT for cement mortar mixed with tailings from the Sangdong tungsten mine, most of heavy metals were determined as below the guide line for waste material. In addition, the setting time and compressive strength of cement mortar mixed with tailings from the Sangdong tungsten mine were investigated. It was indicated that the initial and final set were retarded according to increasing replacement of tailings from the Sangdong tungsten mine. The compressive strength of mortar was decreased with increasing replacement of failings from the Sangdong tungsten mine.

Properties of Undispersed Underwater Mortar Using the Expansive Additives and Fly Ash (팽창재 및 플라이애쉬를 이용하는 수중불분리 모르터의 특성)

  • 한천구;이대주;이광설;한일영;권지훈;유홍종
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.223-231
    • /
    • 1998
  • Existing cast in place piles made by grouting cement mortar have many problems that cracks by autogeneous and drying shrinkage bring about the deterioration of force for piles, segregations by the submersion of ground water occur and also, high cement contents lead to rise the manufacturing cost. Therefore, this study is intended to investigate the mechanical properties of high performance mortar, incorporating expansive additives and fly ash. for cast in place piles. According to the experimental results, as the contents of expansive additives increase in mortar mixture, fluidity decrease and air contents shows inverse tendency. Setting time is delayed. Although compressive strength at 7days shows a decline tendency. compressive strength at 28days and 91days increase slightly with 5% of expansive additives. As fly ash increase in mortar mixture, high fluidity is shown, air contents increase and setting time is delayed at fresh state, and additives are, the larger length change is, whereas shrinkage decrease with the increase of fly ash.

Feasibility Study of Modified Durometer to Evaluate Setting Time of the Concrete (콘크리트의 응결시간 판정시 개량형 듀로미터의 사용 가능성 분석)

  • Han, Cheon-Goo;Han, Min-Cheol;Shin, Yong-Sub
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.433-440
    • /
    • 2020
  • In this study, a new type of Durometer was invented by modifying the currently used Durometer with the hemisphere shaped needle to columnar shaped needle. The aim of the study is, hence, to provide the feasibility of the advanced Durometer for assessing setting time of the concrete. Generally, the finishing of concrete surface should be conducted to secure the smooth surface, improve the permeability, and prevent the plastic shrinkage cracking. Although this surface finishing work should be conducted during the plastic phase between initial and final setting, currently in practical situations, the timing of starting the finishing work was determined by the sense of the worker. To improve this situation, Kato Junji suggested to use the hemisphere and needle shaped Durometers to determine the initial and final setting time, respectively. However, in this case, there are difficulties of using two different Durometers and of occurring failure of the Durometer due to the intruded cement paste. To prove the feasibility of new typed Durometer, setting time and surface hardness were evaluated by applying for the concrete with various replacing ratios of fly-ash and coal gasification slag as an aggregate.

Temperature Dependency Affecting the Properties at Early Age of the Concrete Containing High Volume Blast Furnace Slag (고로슬래그 미분말을 다량 치환한 콘크리트의 초기품질에 미치는 온도의존성)

  • Han, Cheon-Goo;Lee, Jang-Hwa;Koh, Kyung-Taek;Han, Min-Cheol;Lee, Ju-Sun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • This study analysis the fundamental properties of temperature-dependence corresponding the change of curing temperature classified by the replacement ratio of BS, and the results are summarized as following. As the properties of flow, plain satisfied with the target slump, and as the replacement ratio of BS increased, the flow increased, but the air content slightly decreased. The time of set delayed as the replacement ratio of BS increased, but the curing temperature $35^{\circ}C$, even with 80% BS replaced concrete, the time of set was faster than $5^{\circ}C$, $20^{\circ}C$ plain, so the temperature-dependence was much greater. The compressive strength was decreased as the replacement ratio of BS increased, especially as the curing temperature lower, the compressive strength was lower comparatively. Also as the age increased, the plain developed more strength, therefore it show the temperature-dependence is much larger.

  • PDF

Comparison of Concrete Setting Properties for the Application of Tapered Slip-Form method (변단면 슬립폼 공법 적용을 위한 콘크리트의 응결 특성 비교)

  • Song, Yong-Soon;Yang, Woo-Yong;Jung, Gil-Su;Seo, Young-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.459-460
    • /
    • 2010
  • For the application of slip form method to the pylon of Yi Sun-shin bridge which has much variation in its cross section, the change of setting properties of concrete due to changing weather and long pumping distance has to be taken into consideration. Different setting properties of several types of cement according to the amount of compound and ambient temperature were observed in this paper.

  • PDF

Estimation of Setting Time Applying Setting Estimator for AI Finishing Robot System Depending on Water-Cement Ratio (AI기반 콘크리트 마감 자동화 시스템용 응결추정계의 물시멘트비에 따른 응결추정 평가)

  • Park, Jae-Woong;Jeong, Jun-Taek;Lim, Gun-Su;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.17-18
    • /
    • 2023
  • This study aims to compare the hardness value development characteristics according to the water-cement ratio during a series of experiments to develop a setting estimator for an AI-based concrete finishing automation system. For the test variables, water-cement ratios are varied with 30, 40 and 50%. Proctor penetration test and surface hardness test by setting time estimator are conducted to estimate the setting time. For the effect of water-cement ratios, they did not affect the surface hardness either, while initial set time and final set time are not constant with water-cement ratios.

  • PDF