• Title/Summary/Keyword: 콘크리트 보

Search Result 2,485, Processing Time 0.031 seconds

Effects of Shear Reinforcements on the Reinforced High-Strength Lightweight Concrete Beams (고강도 경량 철근콘크리트보의 전단보강 효과)

  • Shin, Sung-Woo;Lee, Kwang-Soo;Ahn, Jong-Mun;Choi, Myung-Shin
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.89-97
    • /
    • 1999
  • In this study, fifteen reinforced high-strength lightweight concrete(HLC)beams were tested to investigate shear behavior of specimens according to shear reinforcement ratio. Test variables are shear span to effective depth ratio(a/d=2.5, 3.5, 4.5) and shear reinforcement ratio(0~1.0${\rho}_{v,ACI}$). Concrete compressive strength and tensile steel reinforcement ratio are constantly 439kg/$cm^2$ and 0.0203, respectively. Test results for the HLC beams showed that ACI code equation underestimates the shear strength of concrete($V_c$), and overestimates the shear strength of shear reinforcements($V_s$). It is revealed that the effectivenesses of shear reinforcements of reinforced HLC beams are lower than those of normal weight concrete beams. Then, the shear strengths of shear reinforcements are increased in proportion not to first degree of shear reinforcement ration but to square root of them.

Effect of Constructional Deflection of Composite Beam on Concrete Ponding in Metal Deck Slab (합성보의 시공중 처짐이 합성데크슬래브의 콘크리트 고임에 미치는 영향)

  • Kim, Young-Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.99-106
    • /
    • 2002
  • In the composite deck system, beams and deck plates deflect during construction. This lens-shaped deflection may cause problems in the serviceability of a building. Therefore, it should be compensated to be level. Several methods for leveling of floor slab are available, such as (1) increasing stiffness of structural members, (2) propping floor system, (3) cambering beams, (4) pouring additional concrete. In this study, additional weight and volume of concrete for level compensation are examined for various size of floors.

Hysteretic Behavior of RC Beams Exposed to Freezing and Thawing under Cyclic Loadings (철근콘크리트보의 동결융해 경험에 따른 반복하중하에서의 이력특성)

  • Jang, Gwang-Soo;Kim, Yun-Su;Seo, Soo_Yeon;Choi, Ki-Bong;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.25-28
    • /
    • 2008
  • Generally, reinforced concrete structures exposed to the outside temperature are affected by freezing and thawing process during winter and early spring. These freezing and thawing process can lead to the reduction in durability of concrete as cracking or surface spalling. This paper is to study the hysteretic behavior of RC beams exposed to freezing and thawing under cyclic loadings. To compare the difference in hysteretic behavior of RC Beams, limited tests were conducted under different types of damage and freezing and thawing cycles. For this purpose, six specimens were tested. It is thought that experimental results will be used as basic data to evaluate hysteretic behavior of RC beams exposed to freezing and thawing.

  • PDF

Effect of Partial Prestressing Ratio and Effective Prestress on the Flexural Behavior of Prestressed Lightweight Concrete Beams (프리스트레스트 경량 콘크리트 보의 휨 거동에 대한 부분 프리스트레싱비와 유효 프리스트레스의 영향)

  • Yang, Keun-Hyeok;Moon, Ju-Hyun;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • The present investigation evaluates the flexural behavior of pre-tensioned lightweight concrete beams under two-point symmetrical concentrated loads according to the variation of the partial prestressing ratio and the effective prestress of prestressing strands. The designed compressive strength of the lightweight concrete with a dry density of 1,770 $kg/m^3$ was 35 MPa. The deformed bar with a yield strength of 383 MPa and three-wire mono-strands with tensile strength of 2,040 MPa were used for longitudinal tensile reinforcement and prestressing steel reinforcement, respectively. According to the test results, the flexural capacity of pre-tensioned lightweight concrete beams increased with the increase of the partial prestressing ratio and was marginally influenced by the effective prestress of strands. With the same reinforcing index, the normalized flexural capacity of pre-tensioned lightweight concrete beams was similar to that of pre-tensioned normal-weight concrete beams tested by Harajli and Naaman and Bennett. On the other hand, the displacement ductility ratio of pre-tensioned lightweight concrete beams increased with the decrease of the partial prestressing ratio and with the increase of the effective prestress of strands. The load-displacement relationship of pre-tensioned lightweight concrete beam specimens can be suitably predicted by the developed non-linear two-dimensional analysis procedure. In addition, the flexural cracking moment and flexural capacity of pre-tensioned lightweight concrete beams can be conservatively evaluated using the elasticity theorem and the approach specified in ACI 318-08, respectively.

Shear Behavior of Concrete Beams Reinforced with FRP Bar (FRP Bar 보강 콘크리트 보의 전단거동)

  • Choi, Ik-Chang;Jung, Dae-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.4
    • /
    • pp.403-409
    • /
    • 2013
  • Shear behavior of concrete beams reinforced with steel and/or FRP bar is studied through experimental tests. Experimental parameters includes the mechanical properties of reinforcements in shear and bending, and the ratio of shear reinforcement. The validity of the modified truss analogy, that has been widely accepted as a basis for the practical shear design of concrete beams, has been examined thoroughly by analyzing experimental results. The experimental results indicate that the modified truss analogy cannot be directly adopted to the shear problem of concrete beams reinforced with FRP bar.

Effect of Concrete Strength on Stirrup Effectiveness in Shear Behavior of Concrete Beams (보의 전단거동에서 콘크리트 압축강도가 스터럽 유효성에 미치는 영향)

  • 이영재;서원명;김진근;박찬규
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.173-182
    • /
    • 1996
  • An experimental research was carried out to investigate the effect of thc compressive strength of concrete on the stirrup effectiveness in shear behavior of concrete beams. For this purpose. total 24 beams of section dimension of $300{\times}600mm$ were tested: 4 specimens without web reinforcement and 20 specimens with web reinforcement in the form of vertical stirrups. Main variables were two levels(norma1 and high strength) of the compressive strength of concrete and six types of t h e shear rcinfor.cement ratios. Prior to experiment, for given sections and assumed material constants, the reference shear reinforcement ratio(${\rho}_vACI$) which leads to the flexure failure using the provisions of the ACI Building Code(AC1 318-95) was calculated. and the shear reinforcement ratios were relatively selected from the value of ${\rho}_vACI$. From test results, it was shown that thc safety factor of ACI eyuation for p1,ediction of shear strength was decreased with increasing the compressive strength of concrete in beams without stirrups. However. it was observed that as the amount of' stirrup is increased, the safety factor for high strength conci,ete beams with high stirrup ratio is ensured more than that for normal strength concrete beams. Therefore i t appears that the stirrup effectiveness of high strength concrete beams is greater than that of normal strength concrete beams.

Flexural Behaviors of RC Beams Strengthened by Light Concrete Precast Composite Panel with an Advanced Fiber Sheet (고성능 섬유쉬트를 부착시킨 경량 프리캐스트 복합패널로 보강된 RC보의 휨거동)

  • 안상호;윤정배
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.483-491
    • /
    • 2002
  • This paper summarizes the results of experimental studies concerning the flexural strengthening of reinforced concrete beams by the external bonding of the new reinforcement material, which is composite panel with an advanced fiber sheet bonded on light concrete precast panel. The structural behaviors of strengthened beams are compared with codes in terms of yield load and ultimate load, deflection, flexural stiffness, ductility. Thirty nine large-scale beams were tested experimentally to evaluate the strength enhancement provided by the composite panel. According to the results, it is shown that beams strengthened with composite panel are structurally efficient and that the strength of the strengthened beams are improved comparing with beams strengthened with fiber sheet.

Experimental Investigation of the Flexural Behavior of Polymer-modified Lightweight Aggregate Concrete One-Way Members (폴리머 개질 경량콘크리트 일방향 부재의 휨 거동에 관한 실험적 연구)

  • Byon, Eun-Hyuk;Kim, Min-Sook;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.551-557
    • /
    • 2010
  • The purpose of this study is to estimate experimentally the flexural behavior, capacity and validity of existing regulation of net tensile strain in lightweight concrete beams and polymer modified lightweight concrete beams. One normal weight concrete beam and four lightweight concrete beams, three polymer modified lightweight concrete beams were constructed as same figure and attempted to evaluate the difference of strength and ductility in specimens of different net tensile strain in extreme tension steel. Test results are indicated in terms of load-deflection behavior and ductility index. As the value of net tensile strain increased, the flexural strength and stiffness of specimen decreased but ductility index increased in both of lightweight concrete beams and polymer modified lightweight concrete beams. It is considered that to achieve similar ductility index of normal weight concrete, net tensile strain in extreme tension steel should exceed 0.005 for lightweight concrete beam and polymer modified lightweight concrete beam.

Experimental Study on Improvement of Bond Performance of RC Beams with High-Strength Shear Reinforcement (고강도 전단철근을 사용한 철근콘크리트 보의 부착성능 향상에 관한 실험적 연구)

  • Kim, Sang-Woo;Kim, Do-Jin;Yoon, Hye-Sun;Baek, Sung-Cheol;Kim, Kil-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.527-534
    • /
    • 2010
  • This study presents a simple method to improve the bond performance of reinforced concrete (RC) beams having high-strength shear reinforcement. In general, the yield strength and the ratio of shear reinforcements are the main parameters governing the shear capacity of RC beams. The yield strength of shear reinforcement, however, has little influence on the bond capacity of RC beams. Therefore, a sudden bond failure of the members with high-strength shear reinforcement can occur before flexural failure. To estimate the structural performance of the proposed method, four RC beams were cast and tested. The main test parameters were the yield strength, ratio, and reinforcing types of shear reinforcements. The experimental results indicated that the proposed method was able to effectively improve the bond performance of RC beams with high-strength shear reinforcement.

Improvement and Evaluation of Seismic Performance for Reinforced Concrete Beam-Column Joints Using High Performance Embedded FRP (고성능 FRP를 활용한 철근콘크리트 보-기둥 접합부의 내진 성능 평가 및 개선)

  • Ha, Gee-Joo;Shin, Jong-Hack;Kang, Hyun-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.385-392
    • /
    • 2011
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (steel plate, carbon fiber sheet, and embedded carbon fiber rod) in existing reinforced concrete buildings. Six specimens of retrofitted beam-column joints are constructed using various retrofitting materials and tested for their retrofit performances. Specimens designed by retrofitting the beam-column joint regions (LBCJ series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the effect of crack control at the time of initial loading and confinement from retrofitting materials during testing. Specimens of LBCJ series, designed by the retrofitting of FRP in reinforecd beam-column joint regions increased its maximum load carrying capacity by 26~50% and its energy dissipation capacity by 13.0~14.4% when compared to standard specimen of LBCJC with a displacement ductility of 4.