Experimental Study on the Punching Shear of foundation using PC columns (PC 기둥을 이용한 기초의 뚫림 전단강도에 관한 실험적 연구)

  • Jang, Il-Young;Park, Hoon-Gyue;Kim, Yeong-Geun;Park, Seung-Min;Kim, Seong-Gyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.409-410
    • /
    • 2010
  • Since the 1980s with the development of construction techniques over 100 floors above 50 floors of the skyscraper was in progress. The advent of high-rise buildings due to an increase in foundation thickness was inevitable. at the moment, construction period and economic efficiency can be improved from decrease of the foundation thickness.

  • PDF

Evaluation of The seismic Performance of Existing Building Structures (기존 철근콘크리트 건축물의 내진성능 평가)

  • Woo, Woon-Taek;Kown, Yong-Hun;Chung, Lan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.105-110
    • /
    • 2000
  • 중약진 지역으로 분류되고 있는 대만에서 1999년에 발생된 예상치 못한 막대한 경제적 피해와 사상자를 기록하였다. 대만과 마찬가가지로 중약진지역으로 분류되는 우리나라에서도 지진발생시 많은 문제발생이 예상됨에 따라 기존건물의 내진성능평가의 필요성의 인식하게 되었다. 본 연구에서는 미국과 일본에서 이미 적용되고 있는 기존 건축물의 내진성능 평가 기법을 분석하고 이를 3층 규모의 모멘트 골조 건물에 적용하여 평가해 보았다. 평가는 일본건축방재협회에는 철근콘크리트 구조물의 내진성능평가 규준을 적용하였다.

  • PDF

Effects of Long Term Deformation of Concrete on Internal Member Forces of Tall Buildings (초고층 건물에서 콘크리트의 장기거동이 부재내력에 미치는 영향)

  • Shin, Seung-Hak;Kim, Han-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.297-300
    • /
    • 2010
  • 본 논문에서는 일반적인 해석, 시공단계를 고려한 해석, 시공단계와 장기거동을 고려한 해석의 3가지 해석방법을 사용하여 수평부재의 설계에 적합한 해석방법을 제안하였다. 80층의 2D 구조모델에 3가지 해석방법을 적용하여 각 해석방법에 따라 부등축소량, 수직부재에 작용하는 축력, 수평부재의 단부에 작용하는 내력의 해석결과를 얻어 비교하였다. 또한 부재의 내부에서 철근과 콘크리트의 하중분담율의 시간에 따른 변화양상을 알아보았다. 해석결과 시공단계에 의한 영향은 수평부재에 작용하는 축력과 부등축소량 예측, 부재 내력 해석에 있어서 반드시 고려되어야 함을 알 수 있었다. 장기거동의 효과는 기둥축소에는 크게 영향을 미치지만 수직부재의 축력, 수평부재의 내력에는 변형만큼의 영향은 보이지 않는다. 시공시의 보정량을 결정하기 위해서는 장기거동이 반드시 고려되어야 하지만 부재의 단면설계의 목적으로는 제외되어도 무방할 것으로 판단된다.

  • PDF

Study on Deflection Evaluation for High-strength Concrete of KCI Specification and Eurocode 2 (콘크리트구조설계기준과 Eurocode 2의 고강도 콘크리트 처짐 산정에 관한 연구)

  • Lee, In-Ju;Kim, Tae-Wan;Kim, Sung-Hu;Son, Chang-Du;Park, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.989-992
    • /
    • 2008
  • Recently, high-strength concrete has been frequently used for long-span bridges and high-rise buildings. Deflection of reinforced concrete structures is uncertain, so that many researchers have proposed various equations in order to predict deflection through experiments. Domestic concrete specification offers a procedure to evaluate deflection using effective moment of inertia which was proposed by Branson. However, it is inaccurate for high strength concrete compared to the method suggested in Eurocode 2 in that Eurocode 2 predicts deflection by using curvature integration of effective moment of inertia. In this study, experimental data about deflection of reinforced concrete beams were analyzed to compare domestic standard and Eurocode 2.

  • PDF

Strengthening of shear resistance of masonry walls (조적벽체의 전단강도 향상 방안에 관한 연구)

  • Kang, Sung-Hun;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.193-196
    • /
    • 2008
  • This paper presents an experimental study to investigate enhanced performance of the masonry walls strengthened in shear and ductility using honeycomb steel mesh. The performance of masonry walls strengthened with steel mesh will compare with unreinforced masonry walls to show the performance of reinforced masonry walls. According to the experiment, it is expected that this system is effective to enhance the shear strength and ductility of the masonry walls.

  • PDF

Design of a Low-rise RC Building with Damping System (저층 철근콘크리트 건축물의 제진 구조 설계)

  • Lee, Eun-Jin;Hyoun, Chang-Kook;Choi, Ki-Sun;You, Young-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.454-457
    • /
    • 2011
  • 본 논문에서는 국내에서 아직 기준이 마련되지 않은 제진설계에 대한 접근을 소개하였다. ASCE 7-05 기준에 근거하여 국내 5층 규모의 철근콘크리트 신축 건물에 제진 설계를 수행하였다. 우리나라의 현행 기준을 만족하면서 효과적인 제진 시스템 설계를 위한 방법을 소개한다. ASCE 7-05 기준에서는 제진 구조물 해석 시 부재력이 공칭강도의 1.5배를 초과하지 않은 경우 경계비선형 해석을 허용하고 있다. 이 때의 제진 설계 프로세스는 기존의 중력하중 및 등가정적하중의 75%에 의한 단면을 가정하여 부재설계를 실시하고, 선형 시간이력 해석을 통해 제진장치 및 가새를 설계한다. 이후 우리나라 실정에 맞도록 보정된 인공 지진파를 입력하여 경계비선형 해석을 실시하고, 밑면 전단력 및 층간변위 등의 만족여부를 검토한다. 이 때 목표성능을 완전탄성설계 또는 유사탄성설계로 정하여 목표성능을 만족하는지도 검토하여야 한다. 본 논문에 적용한 신축 건물은 유사탄성 설계를 위해 경계비선형 해석을 실시하였고, 가장 효과적인 제진 설계를 위해 댐퍼의 종류, 설치방법, 개수, 변위 증폭비 등을 변수로 한 case study를 진행하였다. 해석 결과 목표성능을 만족하는 범위 내에서 가장 효과적인 제진 설계는 점성댐퍼, 이층 토글형태, 증폭비 2.0, 총 8개의 댐퍼를 설치하는 것으로 나타났다.

  • PDF

Evaluation of Concrete Structures Considering Reinforcing Bars in Columns (기둥의 보강철근을 고려한 콘크리트 구조물의 거동 평가)

  • Song, Hyung-Soo;Gwon, Ji-Youn;Cha, Hee-Youn;Min, Chang-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.289-292
    • /
    • 2008
  • In this study, we interpreted 20 story building by applying the modified modulus of elasticity considering the reinforcing steel proposed in previous literature, and analyzed the movement of the structure according to axial reinforcing steel ratio and lateral reinforcing steel volume ratio. Additionally, we tried to get the result similar to the actual movement considering the order of the construction by performing the analysis by construction stage. Finally, we tried to reduce the section of the column through the analysis considering the reinforcing steel of the column. When interpreting the 20 story building considering the reinforcing steel in the columns, we can reduce the column members up to 4.94% comparing to the general analysis. If we do the same for each construction stage, it is analyzed that we can reduce up to 19%.

  • PDF

Interview - Yooshinjae - House of thoughts and trust Achieved the usability of modern space while preserving the old prototype (인터뷰 - 유신재⋯옛 원형 보존하며 현대적 공간의 사용성 이뤄내다)

  • Yuk, Hye-Min
    • Korean Architects
    • /
    • s.630
    • /
    • pp.16-21
    • /
    • 2021
  • 서울 용산구 한강대로에 위치한 529제곱미터 규모의 2층 사옥 '유신재'. 일제강점기 시절 건설된 벽돌(연와조)과 철근콘크리트조, 목조 트러스 지붕 구조의 이 낡은 건물은 준공(1926.06.23)된 지 90년이 훌쩍 넘었으며, 건물주인 (주)유신이 역삼동으로 사옥을 이전한 후 30여 년간 문서보관소로 사용돼왔다. 그런 이 건물이 지난 4월부터 8월까지의 공사를 거쳐 유신건축(주.유신건축 종합건축사사무소)의 사옥으로 새롭게 태어났다. 근 100여 년의 흔적을 그대로 간직한 건물의 리모델링 설계자는 유신건축의 김지덕 건축사(부(父))·김우영 건축사(자(子)/ 영국왕립건축사) 부자(父子)다. 지난 9월 24일, 유신재에서 함께 일하고 있는 두 부자 건축사의 이야기를 직접 들어보았다.