• Title/Summary/Keyword: 콘크리트충전 원형강관

Search Result 44, Processing Time 0.028 seconds

Moment-Curvature Relation of Concrete Filled Circular Steel Tubular Beam with Nonlinear Stress-Strain Properties (비선형 응력-변형률 특성을 갖는 콘크리트 충전 원형강관 보의 모멘트-곡률 관계)

  • Park, Woo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.195-202
    • /
    • 2005
  • This paper presents moment-curvature analytical method of concrete filled steel tubular members considering intensity increase phenomenon by triaxial compression stress generation. For this purpose, this study considers buckling characteristics about compression department of steel members that filled up light weight and normal concrete. The analytical results are compared with the test results. Even if beam that filled up light weight concrete was calculated moment-curvature relationship easily analytically and could know that analytical results estimates as well agreed with the test results in case filled up normal concrete. In addition, the efficiency and applicabilities of the proposed moment curvature relationship algorithm are verified through conventional experimental results.

A Study on the Strength of Concrete Filled Tubular Columns according to Data-Base (Data Base에 의한 CFT 기둥의 내력에 관한 연구)

  • Seo, Jeong-Hwan;Yang, Young-Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.71-79
    • /
    • 2001
  • The concrete filled tubular(CFT) columns have many excellent structural properites. such as high compressive strength high ductility and high absorption capacity However the confinement effect and limiting width-thickness ratio of CFT column have not yet been clarified. Therefore. this paper aims to clarify the confinement effect of steel tubes and strength of concrete filled steel tubular columns. And this paper presents results of a probabilistic analysis based on statistical data for strength of concrete filled steel tubular columns which has been tested in Korea for recent 10 years(1991.1~2000.6).

  • PDF

The Structural Behavior of CFCT Column to H-Beam Connections With Longitudinal Rib of Column at Joint (종리브로 보강한 콘크리트충전원형강관기둥-H형강보 접합부의 구조적 거동에 관한 연구)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.291-301
    • /
    • 1998
  • This paper is a study on the structural behavior of CFCT(Concrete-Filled Circular Tubular) column to H-beam connections with longitudinal rib. The important parameters are being longitudinal rib or not. variable column thickness(5.8mm. 9.2mm. 12.0mm. 15.0mm) around the joint between CFCT and H-beam and the width of flange to diameter. Test results are summarized for the strength, initial stiffness, failure mode and energy absorption capacities of each specimen. These are compared with the theoretical results(Yield line theory, numerical analysis). Therefore, the purpose of this paper is to investigate the stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections with longitudinal rib.

  • PDF

An Experimental Study on the Compression Behavior of the Circular and Square Tubular Steel Pipe filled with Concrete (콘크리트 충전 원형 및 각형 합성 강관 기둥의 압축 거동에 관한 실험적 연구)

  • Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.1 s.19
    • /
    • pp.55-63
    • /
    • 2006
  • Concrete-filled steel columns consist of circular, square or rectangular hollow sections filled concrete. Much research has studied for the behavior of concrete-filled steel structures. The advantages from structural point of view are the triaxial confinement of the concrete within the section, and the fire resistance of the column which largely depends on the residual capacity of the concrete core. The axial capacity of a concrete-filled rectangular or circular section is enhanced by the confining effect of the steel section on the concrete which depends in the magnitude on the shape of the section and the length of the column. Buckling tends to reduce the benefit of confinement on the squash load as the column slenderness increases. In circular sections it is possible to develop the cylinder strength of the concrete. When compare with reinforced concrete columns, the concrete-filled composite column possesses much better strength and ductility in shear and generally in flexure also. Many researches are being conducted about concrete filled steel column to get these advantages in building design. In this paper it is provided to the basic experimental study of compression behavior of the circular and rectangular tubular steel pipe filled with concrete.

  • PDF

Estimation of the Local Load-Carrying Capacities of CFCT Column to H-Beam Connections by Yield Line Model -With regard to the Tensile side of Beam flange- (인장측 보플랜지의 항복선 모델을 이용한 CFCT기둥-H형강보 접합부의 국부내력평가)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.525-536
    • /
    • 1998
  • This paper is concerned with a theoretical study on the local load-carrying capacities of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections by yield line theory. In this paper, the three cases which are assumed the yield line are involved. The first model is a simplified yield line model. The second model is modified by x and kx factors. The last one is a Morita's model. The local load-carrying capacities of CFCT column to H-beam connections has been studied both experimentally and theoretically using the yield line theory. The purpose of this paper is to suggest the basic data for developing the non-diaphragm connection.

  • PDF

A Study on Properties of Mechanical Behaviors of Concrete Confined by Circular Steel Tube (원형강관으로 구속된 콘크리트의 역학적 거동 특성에 관한 연구)

  • 박정민;김화중
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.199-210
    • /
    • 1995
  • We could say that the concrete filled steel tube structure is superior in the vlew of various structure properties as to promote improvement of structural capacity to dtmonstrate heterogeneous material properties interdependently. The compressive strength is increased by putting to tri axial stress because lateral expansion of concrete 1s confined by the steel tube, when concrete conflned by steel tube fall under centric axial load. Also, it have an advantage that decreasr of load carrying capacity 1s small, not occuring section deficiency due to protect falling piienornonon by co~nprrssion fallurc of concrete. So this study investigated for structural behaviors yroprrtiex of concwir. confined by steel tube throughout a series of experlmerit with kcy parxncter, such as diameter-to-thickness(D / t) ratio, strength of concrete as a study on properties of structural behaviors of confined concrete confined by circular steel tube( tri axial stress). Frorn the expcrment results, the obtained results, are surnrnarised as foliow. (1) The restraint effect of concrete by steel tube was presented significantly as the D /t ratio of steel tube and the strength of filled concrete decrease, and the confined concrete by circular steel tube was increased respectively twice as much as 4-7 in deformation capacity at the ultimate strength ,compared with those of non-confined concrete, so expected to increase flexible effect of concrete. (2) The emprical formula to predict the ultimate capacity of confined concrete by steel tube and concrete filled steel tube column using restraint coefficient of concrete were proposed.

A Study on the Strength and Stiffness of the Concrete Filled Circular Tube Beam to Column Connections under the Gravity Loads (연직하중을 받는 콘크리트충전 원형강관기둥의 접합부 내력에 관한 연구)

  • Lee, Myung Woo;Choi, Sung Mo;Kim, Dong Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.611-623
    • /
    • 1997
  • This paper provides the results of an experimental and analytical study performed on the beam to Concrete Filled Circular Steel Column connections with the external stiffener rings under the gravity loads. Specimens are modeled as a 1/4 scale of the beam-columns as gravity loads are applied to a multi-story frame. Important parameters in this study are the width of the external rings, the diameter-thickness ratios of column and whether or not the external rings are welded to the circular column. A total of 20 specimens are tested to clarify the structural behavior of the CFT column connections with the external stiffener rings. The test results are summarized for the yield and maximum strength and stiffness. The existing design equations for the allowable and yield load capacities are referred to verify the structural characteristics for the connections.

  • PDF

Torsional Behaviour of Concrete Filled Circular Steel Tube Column Considering Confinement Effect (구속효과를 고려한 콘크리트 충전 원형강관 기둥의 비틀림 거동)

  • Yun, Bok Hee;Lee, Eun Taik;Park, Ji Young;Jang, Kyong Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.529-541
    • /
    • 2004
  • Concrete filled steel tube structures were recently used in constructing high-rise buildings due to their effectiveness. Studies on concrete filled steel tubes have been focused on the experiments of uni-axial compression and bending and eccentric compression. There were also a few studies that investigated CFT member behavior under combined compression and torsion. The behavior of a circular CFT column under combined torsion and compression was theoretically investigated, considering the confinement of steel tubes on the concrete, the softening of the concrete, and the spiral effect, which were the dominant factors that influenced compression and torsion strength. The biaxial stress effects due to diagonal cracking were also taken into account. By applying those factors to compatibility and equilibrium conditions, the basic equation was derived, and the equation could be used to incorporate the torsional behavior of the entire loading history of the CFT member.

A Study on the Mechanical Properties of Concrete Filled Steel Tube Column under Centric Axial Load (중심축력을 받는 콘크리트 충전강관 기둥의 역학적 거동 특성에 관한 연구)

  • 박정민;김화중
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.5
    • /
    • pp.133-144
    • /
    • 1995
  • This study investigated to the properties of structural behaviors through a series of experiment with the key parameter, such as diameter-to-thickness(D/t) ratio, selenderness ratio of steel t~ube and strength of concrete under loading condition simple confined concrete by steel tube as a fundmental study on adaptability with structural members in high-rise building. The obtained results are sumnarised as follow. (1) The fracture mode of confined concrete was presented digonal tension fracture in the direction of $45^{\circ}$ with compression failure at the end of specimen in stub column, but the fracture mode of long column was assumed an aspect of bending fracture transversely. (2) The deformation capacity and ductility effect was increased by confine steel tube for concrete. (3) 'The emprical formula to predict the ultimate capacity of confined concrete by steel tube and concrete filled steel tube column using restraint of concrete considered D / t ratio, selenderness ratio of steel tube anti strength of' concrete were proposed.

Fire Resistance of Concrete-Filled Circular Steel Tube Columns under Central Axial Loads (일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가)

  • Park, Su Hee;Song, Kyung Chul;Ryoo, Jae Yong;Chung, Kyung Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.655-663
    • /
    • 2008
  • In this research, the fire resistance of Concrete-Filled Circular Steel Tube Columns (CFT) was evaluated by numerical analysis. As the materials of CFT columns, the steel of SPSR 400 grade and the concrete of 27.5MPa, 37.8MPa strengths were used. Significant parameters,such as concrete strength, axial load, and cross-sectional dimensions were determined. To verify the accuracy of the numerical analysis,the analysis results were compared with the former experiment results. The effect of the fire resistance time, axial load ratio, cross-sectional dimensions and concrete strength was evaluated by comparison with the fire resistance of the square CFT columns. This research showed that the structural behavior and fire resistance from the findings of numerical parametric studies showed a similarity to that of the experimental results. Therefore, this numerical analysis is reasonable in estimating the fire resistance of the circular CFT column.