• Title/Summary/Keyword: 콘크리트용

Search Result 1,822, Processing Time 0.028 seconds

A Study on the Resource Recovery of Fe-Clinker generated in the Recycling Process of Electric Arc Furnace Dust (전기로 제강분진의 재활용과정에서 발생되는 Fe-Clinker의 자원화에 관한 연구)

  • Jae-hong Yoon;Chi-hyun Yoon;Hirofumi Sugimoto;Akio Honjo
    • Resources Recycling
    • /
    • v.32 no.1
    • /
    • pp.50-59
    • /
    • 2023
  • The amount of dust generated during the dissolution of scrap in an electric arc furnace is approximately 1.5% of the scrap metal input, and it is primarily collected in a bag filter. Electric arc furnace dust primarily consists of zinc and ion. The processing of zinc starts with its conversion into pellet form by the addition of a carbon-based reducing agent(coke, anthracite) and limestone (C/S control). These pellets then undergo reduction, volatilization, and re-oxidation in rotary kiln or RHF reactor to recover crude zinc oxide (60%w/w). Next, iron is discharged from the electric arc furnace dust as a solid called Fe clinker (secondary by-product of the Fe-base). Several methods are then used to treat the Fe clinker, which vary depending on the country, including landfilling and recycling (e.g., subbase course material, aggregate for concrete, Fe-source for cement manufacturing). However, landfilling has several drawbacks, including environmental pollution due to leaching, high landfill costs, and wastage of iron resources. To improve Fe recovery in the clinker, we pulverized it into optimal -sized particles and employed specific gravity and magnetic force selection methods to isolate this metal. A carbon-based reducing agent and a binding material were added to the separated coarse powder (>10㎛) to prepare briquette clinker. A small amount (1-3%w/w) of the briquette clinker was charged with the scrap in an electric arc furnace to evaluate its feasibility as an additives (carbonaceous material, heat-generating material, and Fe source).

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

A Study on the Fire Reconstruction of Exterior on High-rise Building (Focus on Fire Case Including the Woosin Golden Suite in Haeundae) (고층 건축물 외장재의 화재 재현에 관한 연구 (해운대 우신골든스위트의 화재사례를 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • 'Heaundae Woosin Building' fire was the case that a fire breaking out on the $4^{th}$ floor spread out the $38^{th}$ floor which is a top story and the penthouse was destroyed by fire. After this fire, the fire safety for high rise buildings has been on the rise and several new laws and regulations related in the buildings were created. The study is to analyze Heaundae officetel building case using FDS which is one of the CFD programs for fire. The methodology of this study is to analyze the case comparing with fire spread and route from a virtual fire simulation and related articles and a video clip of actual scene fire. This study shows that a fire spreading on top of levels spent approximately 30 minutes and, which is similar to the actual fire case. Also the pattern of spread has similarity with the case. However, even if the actual fire case shows the fire pattern was "V shape", the smoke-view presents the fire dose not spread horizontally as much as the real fire case. The result shows uncertainty of the modeling based on many grids and a limitation of putting interior finish input sources and the direction of the wind might cause the difference. Also, to analyze factors influencing on a vertical fire, another fire modeling is performed by in condition of modeling environment considering concrete interior finish between buildings and no wind. The result presents the fire spread in smoke-view does not spread vertically as much as the actual case.

Study on the Direct Tensile Test for Cemented Soils Using a Built-In Cylinder (내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구)

  • Park, Sung-Sik;Lee, Jun-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1505-1516
    • /
    • 2014
  • In this study, a cylinder embedded within cemented soils was used to cause directly tensile failure of cemented soils. An existing dumbbell type direct tensile test and a split tensile test that is most general indirect tensile test were also carried out to verify the developed built-in cylinder tensile test. Testing specimens with two different sand/cement ratios (1:1 and 3:1) and two curing periods (7 and 28 days) were prepared and tested. Total 10 specimens were prepared for each case and their average value was evaluated. Unconfined compression tests were also carried out and the ratio of compressive strength and tensile strength was evaluated. The tensile strength determined by built-in cylinder tensile test was slightly higher than that by dumbbell type direct tensile test. The dumbbell type test has often failed in joint part of specimen and showed some difficulty to prepare a specimen. Among three tensile testing methods, the standard deviation of tensile strength by split tensile test was highest. It was shown that the split tensile test is applicable to concrete or rock with elastic failure but not for cemented soils having lower strength.

Advanced C.I.P Method to Use the Steel-Casing with Inner Joint (조인트 부착 강관 케이싱을 이용한 개량형 C.I.P 공법)

  • Jang, Seoyong;Choi, Jaesoon;Song, Byungwoong;Choi, Yoonyoung;Yoon, Joongsan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.95-102
    • /
    • 2012
  • In this study, practical verifications for an advanced C.I.P(Cast in Place Pile) construction method were carried out. The structural characteristics of the method is to attach an angular joint in the steel-casing. This joint plays an important role in boring vertically, connected pile to pile, and protects the permeation of the ground water. For verifications, experimental research and numerical analysis were performed. In the experimental research, two model-tests were set up with the real scale steel-casing. One is to examine the leakage in the joint of piles and the other is to compare earth pressures in the front and the joint, respectively. In addition, 3 point bending test and compressive loading test were carried out and numerical analysis was performed to simulate the loading test. As a result of model-tests, the leakage in the pile joints was not shown up to 300 KPa of water pressure and stress concentration in the joint is out of the question. From the results of bending and compressive test, it was found that the new advanced C.I.P method is more convenient and superior than the conventional method.

Effect of Environmental Conditions on Expansion of Mortar-bar by Alkali-Silica Reaction (환경조건이 알칼리-실리카 반응에 의한 모르타르 봉 길이 팽창에 미치는 영향)

  • Kim, Seong-Kwon;Yun, Kyong-Ku;Hong, Seung-Ho;Kang, Moon-Sik
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • The possibility of ASR(alkali-silica reaction) for coarse aggregates had known to be low up to recently in Korea. But the distress of ASR was identified and reported by ASTM C 1260 test. The purpose of this paper was to identify the effect of environmental conditions on length expansion of mortar-bar by alkali-silica reaction with KS F 2546 and ASTM C 1260 test. The results of this study were as following; The result of KS F 2546 test for five kinds of aggregates shows that all of them are non-reactive. But that of ASTM C 1260 test shows that all of aggregates except Andesite-2 are over possible reactive because of environmental condition such as external alkali ion by 1N NaOH, high temperature and humidity. The result of variety of NaOH concentration on ASTM C 1260 using Siltstone indicates that length expansion rate increases highly as NaOH concentration increases. And, comparison results of KS F 2546 for Siltstone with that of 0.00N NaOH experiment indicates that length expansion rate increases as temperature and humidity increases.

Embedded EM Sensor for Tensile Force Estimation of PS tendon of PSC Girder (PS 긴장재 긴장력 계측을 위한 PSC 거더 내부 매립용 EM 센서)

  • Park, Jooyoung;Kim, Junkyeong;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.691-697
    • /
    • 2015
  • In this paper, an embedded EM sensor was researched to estimate prestressing force of PS tendon in PSC girder. Recent methodologies for managing prestressing force loss were staying on verifying a applying prestressing force under construction, namely the loss management can not be controlled after construction. To estimate the tensile force of PS tendon during lifetime of PSC girder, this research proposed a bobbin-type embedded EM sensor that can be embedded in PSC girder is designed and fabricated considering the shape properties of anchorage zone and sheath. To verify the proposed sensor, a small PSC girder test was performed. The embedded EM sensor was connected to a sheath and anchor block, and the concrete was poured. After curing, the change of the permeability of PS tendon under tensile forces of 200, 710, 1070, 1300kN was measured using embedded EM sensor. The permeability of PS tendon had decreased according to the increment of applied tensile force. Also it is confirmed that the change of permeability due to applied tensile force could resolve the applied tensile force values. As a result, proposed embedded EM sensor could be embed into the PSC girder and it could be used to estimate the tensile force variation during lifetime of PSC girder.

Physical and Environmental Properties According to Borax Addition Ratios of Inorganic Filling Adhesive using Magnesia Silicate Phosphate (마그네시아 실리케이트 인산염을 활용한 무기충전 접착재의 붕사 첨가율에 따른 물리·환경적 특성)

  • Kim, Tae-Hyun;Shin, Jin-Hyun;Lee, Sang-So
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • The purpose of this study is to develop an inorganic filling adhesive using MKP and borax based on Dead-burn magnesia and fly ash. First, basic experiments was conducted to derive the proper addition rate of MKP. And this experiment was carried out according to addition ratio of borax. The test items are measured for pot life, flexural strength, compressive strength, adhesive strength, tensile strength, ratio of temperature change, ratio of hardening shrinkage, radon gas and formaldehyde emission. As a result, the proper addition rate of phosphate was 35%. The pot time is about 10minutes, 15minutes and 25minutes according to addition rate of borax. The flexural strength and compressive strength were obtained at 12hours for minimum flexural strength of 8.0MPa and minimum compressive strength of 31.0MPa. The tensile strength was the least 4.1MPa, and the ratio of hardening shrinkage was maximum 2.4% and ratio of heat change was maximum - 0.3%, which satisfied all of the quality standards of 'KS F 4923' (epoxy resin for repairing concrete structures). Both Radon gas and formaldehyde emission was not detected.

Development of a new armor unit against high waves (고파랑 대응 신형 소파블록 개발)

  • Park, Young Hyun;Youn, Daeok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.737-743
    • /
    • 2016
  • Coastal hazards such as high waves are expected to increase due to global climate change. Therefore, we investigated new armor unit structures for disaster prevention. Recently, a concrete caisson has been used in many breakwaters against high waves in South Korea, but the demand for concrete armor unit has increased due to the high cost and many installation requirements. Though many new armor units have been developed over the world since Tetrapod in 1950, few have been used due to lack of systematical development. The representative armor units in current use have many advantages, but they cannot be applied to waves higher than 8 m. One of the new armor units developed by the design guide based on recent trend and hydraulic model experiments were conducted. The new armor unit was developed as a single layer due to cost effectiveness. However, the thickness is close to 1.5 times by overlapping the alphabet A and V. It showed higher overtopping compared to a double layer because of the thickness and the high packing density. It has a high interlocking vertically but low horizontally. It shows good stability at 9 m in model testing.

Mechanical Characteristics of Municipal Waste Incineration Bottom Ashes (생활폐기물 소각 바닥재의 역학적 특성)

  • Oh, Myounghak;Lee, Jeonghyeop;Park, Haeyong;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.11
    • /
    • pp.21-27
    • /
    • 2015
  • Due to the population growth and development of industry, waste from household and industries has increased. As the advanced countries experienced these problems, they have already started research on recycling methods of waste incineration ashes. Domestic recycling rate of incineration ash became up to 80 percent as high as the level of developed countries, but the recycling was limited to fly ash for admixture in concrete. In case of bottom ash, most of bottom ash was reclaimed in the landfills. Therefore, basic physical property and mechanical experiments for bottom ash were conducted in this study to evaluate the possibility of incineration bottom ash as an alternative construction materials. Bottom ashes from three different landfills with two different incineration methods were tested. Incineration methods are Stoker type Incinerator and Pyrolysis-Melting Treatment. Bottom ash can be used as an alternative granular material for construction based on the basic physical property and mechanical characteristics similar to those of sandy materials. However, the incineration method should be considered since it can affect the material and mechanical characteristics of the incineration bottom ash.