• Title/Summary/Keyword: 코어 안정성

Search Result 124, Processing Time 0.031 seconds

A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system (산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구)

  • Kim, Kiyoung;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • The major purpose of this study is to construct an in-situ soil moisture verification network employing Frequency Domain Reflectometry (FDR) sensors for Cosmic-ray soil moisture observation system operation as well as long-term field-scale soil moisture monitoring. The test bed of Cosmic-ray and FDR verification network system was established at the Sulma Catchment, in connection with the existing instrumentations for integrated data provision of various hydrologic variables. This test bed includes one Cosmic-ray Neutron Probe (CRNP) and ten FDR stations with four different measurement depths (10 cm, 20 cm, 30 cm, and 40 cm) at each station, and has been operating since July 2018. Furthermore, to assess the reliability of the in-situ verification network, the volumetric water content data measured by FDR sensors were compared to those calculated through the core sampling method. The evaluation results of FDR sensors- measured soil moisture against sampling method during the study period indicated a reasonable agreement, with average values of $bias=-0.03m^3/m^3$ and RMSE $0.03m^3/m^3$, revealing that this FDR network is adequate to provide long-term reliable field-scale soil moisture monitoring at Sulmacheon basin. In addition, soil moisture time series observed at all FDR stations during the study period generally respond well to the rainfall events; and at some locations, the characteristics of rainfall water intercepted by canopy were also identified. The Temporal Stability Analysis (TSA) was performed for all FDR stations located within the CRNP footprint at each measurement depth to determine the representative locations for field-average soil moisture at different soil profiles of the verification network. The TSA results showed that superior performances were obtained at FDR 5 for 10 cm depth, FDR 8 for 20 cm depth, FDR2 for 30 cm depth, and FDR1 for 40 cm depth, respectively; demonstrating that those aforementioned stations can be regarded as temporal stable locations to represent field mean soil moisture measurements at their corresponding measurement depths. Although the limit on study duration has been presented, the analysis results of this study can provide useful knowledge on soil moisture variability and stability at the test bed, as well as supporting the utilization of the Cosmic-ray observation system for long-term field-scale soil moisture monitoring.

Prediction of Thermal and Elastic Properties of Honeycomb Sandwich Plate for Analysis of Thermal Deformation (열변형 해석을 위한 허니컴 샌드위치 평판의 열 및 탄성 물성치 예측에 관한 연구)

  • Hong, Seok Min;Lee, Jang Il;Byun, Jae Ki;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.347-355
    • /
    • 2014
  • Thermal problems that are directly related to the lifetime of an electronic device are becoming increasingly important owing to the miniaturization of electronic devices. To solve thermal problems, it is essential to study thermal stability through thermal diffusion and insulation. A honeycomb sandwich plate has anisotropic thermal conductivity. To analyze the thermal deformation and temperature distribution of a system that employs a honeycomb sandwich plate, the thermal and elastic properties need to be determined. In this study, the thermal and elastic properties of a honeycomb sandwich plate, such as thermal conductivity, coefficient of thermal expansion, elastic modulus, Poisson's ratio, and shear modulus, are predicted. The properties of a honeycomb sandwich plate vary according to the hexagon size, thickness, and material properties.

Safety Assessment of Embankment by Analysis of Electrical Properties (전기비저항 물성 분석을 통한 제체의 안정성 검토)

  • Oh, Seok-Hoon;Suh, Baik-Soo
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.245-255
    • /
    • 2008
  • The variation of the electrical property of embankment material was analyzed from laboratory experiments and the result of field survey, in order to enhance the interpretation of electrical resistivity survey frequently used for safety assessment of embankment. At first, the kaolinite, showing similar physical property with core material of embankment, was used to examine the variation of the resistivity value according to degree of consolidation. The test showed that a drop of shear strength induces increase of resistivity value regardless of degree of water content. This result means that porous zones of weak core material in embankment may be appeared as highly resistive part in the electrical resistivity survey. This observation implies that it may fail to detect weak core material by electrical method, if we only try to and zones showing low resistivity value. And, we performed Standard Penetration Test (SPT) to analyze the correlation between electrical property and ground stiffness. Finally, a mechanism to describe the variation of electrical resistivity due to grouting effect was proposed and real field data were analyzed.

A Study on the Section Change Using the Slip-Form Method (슬립폼 공법 적용 시 단면변화에 대한 고찰)

  • Suh, Jin-Sun;Han, Jun-Young;Im, Chil-Soon
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.123-128
    • /
    • 2007
  • Already, core wall construction method for apartment wall structure and general building special areas applied the engineering method's appropriate examination. Also, trial and error depending on slip-form method is a good examination opportunity to consider. In the present paper's slip-form engineering method l)Casting concrete to slab in sliding 2)RC structure + SRC structure (part of segment) 3)Inside segment variation(straight line-diagonal-circle) are together while determining whether it is possible not to carry out actual construction work on the structure. Finally, small problems continuously appear on actual slip-form method application, design and engineering, starting with planning thoroughly the field examination and diagnosing the atmosphere, minimizing cost, secure work safety facilities characterized by good quality, slip-form research extension, development and decision-making.

  • PDF

A study on Waviness of Large Discontinuity using 3D Laser Scanner (3D Laser Scanner를 이용한 대규모 불연속면의 굴곡도 측정 연구)

  • Kim, Yong;Lee, Su-Gon;Kim, Chee-Hwan
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.119-124
    • /
    • 2017
  • The waviness of Large Discontinuity rock is the one of important elements that judges the stability of rock slope. When the waviness of large discontinuity is measured in the field, there are many limitations Therefore this research was carried out to measure waviness of large rock discontinuities using 3D laser scanner to supplement this problem. This research established one 3D model that actual X, Y and Z coordinates through the integrated data gained from one that calculates waviness of base lock using CAD program was compared and analyzed to that of disc-clinometer. As its results, the high reliability of results could be recognized as it belongs to mechanical tolerance $1{\sim}2^{\circ}$ and the results belong to the measured values of Mean DIP and Mean are all within $1^{\circ}$. So, the investigation method of waviness of large discontinuity rock face using 3D laser scanner was verified as more prompt, effective and reliable method than conventional direct site measuring method.

Effect of abdominal drawing in maneuver with pelvic floor exercise on abdominal muscle thickness measured by ultrasonography (골반 바닥근육 운동을 이용한 복부 드로잉-인이 초음파 측정 방법을 이용한 복부 근육 두께에 미치는 영향)

  • Choi, You-Jeong;Son, A-Reum;Hong, Ji-Heon;Yu, Jae-Ho;Kim, Jin-Seop;Lee, Dong-Yeop
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.7
    • /
    • pp.93-100
    • /
    • 2019
  • The purpose of this study is to measure abdominal muscle thickness when Pelvic Floor contraction (PFC) and Abdominal Drawing-In Maneuver (ADIM) were separately applied and combined exercise was applied and to compare the effects of the exercise. After the pre-investigation, the subjects were given a explanation of the purpose and the method of the research and then an experiment was conducted targeting a total of 30 subjects, who voluntarily agreed with this. Thicknesses of internal oblique (IO), transverse abdominis (TrA) and external oblique (EO) were measured during a break and then three types of exercise. All the measured values of the experiment were processed using Repeated measure ANOVA, and Bonferroni method was applied. As a result, the three types of exercise showed significant differences in thicknesses of IO, TrA and EO. In conclusion, the subjects had the thickest muscles and muscular activity increased during PFC+ADIM, compared to PFC and ADIM.

A Study on Effects of the Fall Prevention in the Rehabilitation Pilates Exercise (노인의 재활 필라테스 운동이 낙상 예방 효과에 대한 고찰)

  • Ji-Sun Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.290-300
    • /
    • 2023
  • This study was understood the risk mechanism of falls in the elderly and reviewed previous research data to see if the principle of Pilates rehabilitation exercise could have a positive effect on balance ability and postural stabilization in the elderly, and the purpose of this study is to present literature-based data on the fall prevention effect of rehabilitation Pilates exercise. First, the rehabilitation Pilates exercise makes it available for strengthening the center of the body to stabilize the spine and pelvis and stimulates the nerve root, thereby having an effect on the balance and the joint stabilization. Second, a proprioceptive sensory impairment and a musculoskeletal degenerative disease due to aging increase the loss of balance ability and the instability in posture maintenance, thereby coming to raise the risk of a fall damage caused by the difficulty in performing motor functions and by the gait disturbance. Third, the rehabilitation Pilates exercise leads to improving the core muscle strength in older adults, resulting in being capable of expecting the betterment in the balance and the reaction time motor function. And there is a positive impact on the improvement in body imbalance and on the stability in movement involved in the fall prevention, resulting in being able to suggest the possibility of likely contributing to a reduction in a fall risk rate. In conclusion, the rehabilitation Pilates as the elderly exercise program showed effects on the improvement in the body's muscular strength, on the upgrade in a sense of balance, and on the stabilization of core. Thus, it was considered to diminish the risk factors for a fall damage caused by musculoskeletal degeneration and to be capable of preventing a serious disorder of activity due to a chronic senile disease.

Dynamic Analysis of 3 Different Cross-Sectional Shapes of a Fill Dam using 3D FEM Analysis (3차원 유한요소해석에 의한 필 댐의 3가지 단면 형상을 고려한 지진해석)

  • Choi, Byoungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.37-43
    • /
    • 2015
  • Dam movements are identified in real-time with measuring instruments for dam maintenance. However, for dams that have aged, the measuring instruments that were installed during the dam construction are frequently malfunctioning or completely failing altogether. Precision safety diagnosis is being executed for dams that are national facilities Type 1. During the diagnosis, a safety assessment is conducted for the dam body. Normally, during the analysis of dam safety, the widest cross-section is selected and a two-dimensional numerical analysis is taken place for the cross-section. However, numerous researchers have recently looked into applying the 3-dimensional numerical analysis program developments to precisely analyze the structure of the dam, as well as the surrounding strata, and the lower dam strata. In this study, PLAXIS 3D, a geotechnical generic FEM analysis program, was used to conduct dam safety assessments for earthquakes. The following were compared and analyzed: considering the seismic properties of the dam body with all zoned structures reflected as one rock-fill zone together with the dam body, considering the dam body as the rock-fill zone and the core zone, and the numerical analysis results. Thus, the study was aimed to analyze the impact properties of seismic waves according to the different zones.

초고속 터보 분자펌프의 자기부상 회전 특성 해석

  • No, Seung-Guk;Gyeong, Jin-Ho;Park, Yong-Tae;Go, Deuk-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.97-97
    • /
    • 2012
  • 반도체 및 디스플레이 공정등에서 고진공 및 급 배기 환경을 제공하기 위하여 사용되는 터보분자펌프 (Turbomolecular Pump, TMP)는 다층의 회전깃을 갖는 로터를 회전시켜 분자를 배출시키는 방식을 사용하는 진공펌프이다. 또한 최근에는 디스플레이 및 반도체 공정에서 높은 진공도뿐만 아니라, 높은 배기속도를 요구하는 추세에 따라, 터보 펌프와 드래그 펌프부분을 동시에 가지고 있어 상대적으로 작동 진공도 영역이 넓은 복합 분자펌프(Compound Turbomolecular Pump, CMP)의 활용도가 넓어지고 있다. 이러한 분자펌프가 장시간의 고속회전에 적합하고, 베어링에서의 오염을 없앨 수 있는 비접촉 방식인 자기부상 방식이 주로 적용된다. 자기베어링 시스템은 하드웨어와 소프트웨어로 나누어질 수 있는데, 하드웨어는 회전하게 되는 블레이드 로터 및 자기베어링 로터, 모터 로터 등이 포함된 축과 고정되어 있는 자기베어링 코어와 코일, 변위센서 등의 펌프 하우징 부분, 또한 이를 제어하기 위한 전력 증폭 시스템 등의 기전적인 요소들이 이루어져 있다. 소프트웨어라 할 수 있는 제어시스템에 있어서 자기 베어링이 불안정한 특성을 갖는 개루프계를 갖고 있으므로 안정화를 위한 능동제어 시스템이 필수적이며 진동제어 등의 기능을 갖도록 적용된다. 따라서 이러한 복합분자펌프의 성능은 이러한 시스템을 구성하는 개별 요소의 성능과 이를 통합한 제어시스템의 성능이 결정한다고 할 수 있다. 본 논문에서는 현재 개발중인 2,500 l/s급의 자기부상형 고진공 복합분자펌프의 시작품에 대하여 고속회전의 안정성에 대한 연구를 수행한 내용을 보고하고 있다. 디지털 제어시스템을 적용한 시작품의 최대 26,000 rpm까지의 고속회전시의 회전 응답 및 진동 특성을 측정 분석하였으며, 로터의 고유진동수 및 진동 모우드를 분석하였다. 또한 연속 작동시의 발열특성과 각 부분의 온도와 회전 안정성과의 관계를 평가하였다.

  • PDF

A Wireless Energy Transmission For Capsule Endoscopes (캡슐형 내시경 구동을 위한 무선 에너지 전송)

  • Seo, Min-Sung;Ko, Young-Suk;Park, Shi-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.80-85
    • /
    • 2008
  • Capsule endoscopes generally use primary cells as a power source due to its limited space. However, the primary cells have several limitations such as high cost, limited power and no reuse. To solve these problems, a new wireless energy transmission method is proposed. The proposed approach uses air-gap transformer concepts and LC resonance to transmit energy from transmitter(primary side) to capsule endoscopes(secondary side). The ferrite core with 3-axis winding is used to increase energy transfer efficiency regardless of direction and location. The experimental results show that the proposed method stably supplies 30mW power to secondary circuit.