• Title/Summary/Keyword: 케이블 트레이

Search Result 9, Processing Time 0.03 seconds

The Development of Interface technology Between 3D Modeling Data and Cable Engineering Program Data (전선로 3D Modeling 데이터와 케이블 엔지니어링 데이터의 연계 기술개발)

  • Cho, Sung-Don;Yoo, Gi-Hong;Kim, Soon-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.400-401
    • /
    • 2007
  • 3D Modeling S/W인 PDS(Plant Design System)의 Electrical Raceway Modeling Software인 EE-Raceway로 작성된 DB에서 트레이, 트레이 Link, Fitting 데이터를 추출하여 케이블 엔지니어링 프로그램의 Input 자료로 활용하는 연계기술과 활용에 대하여 소개하고자 한다

  • PDF

Automated Cable Route Design based Flexible Cable Fill Check of Raceway in Cable Spreading of Generating Station (발전소 케이블 포설에서 Raceway의 유연한 케이블 Fill 체크 기반 자동화된 케이블 라우팅 설계)

  • Park, Ki-Hong;Lee, Yang Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.607-614
    • /
    • 2016
  • In generating station, cable spreading design is a very important task, which is very much time consuming, due to the type of cable used in generating station is very diverse. The raceway means the cable line section from source equipment to destination, and consists of cable tray and conduit. The process of existing cable spreading design was written in by hand. Thereby, there are grossly inefficient gain such as cable omission and unfixed fill value by a personal and time investment. In this paper, we proposed and implemented the automated cable route design based flexible cable fill check in generating station, and proposed the automated cable route design can be calculated the cable fill with flexible changing of raceway. Some experimental result shows that implemented cable route design is well performed and conducted as the design specifications, and it will be able to reduce the cable spreading design time.

Development of Parametric Design Tool for Offshore Plant Cable Tray Using PML (프로그램 매크로언어를 이용한 해양 플랜트 케이블 트레이의 파라메트릭 설계 도구 개발)

  • Kim, Hyun-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.632-637
    • /
    • 2019
  • The cable tray design of an offshore plant production design is to optimally arrange the 3D modeling so that the cable can be installed without interfering with the structural members and various outfit equipment, and it is performed using a PDMS (Plant design management system), which is a 3D CAD system for an offshore plant layout. This study reviewed the development of PML (Programmable macro language) for a PDMS supporting offshore plant cable tray design and examined the efficiency compared to the existing method. Cable tray design PML developed in this paper enables fully parametric design using electrical outfit template library, allowing a rapid response to frequent modifications due to design changes and minimizing repetitive work fatigue by reflecting the accumulated design experience. In addition, the developed system was applied to the offshore plant structure module and it improved the work efficiency by more than 50% compared to the existing method.

Development of a Design System for a Cable Tray (케이블 트레이 설계시스템 개발)

  • Choi, Du-Soon;Choi, WooSeok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.89-96
    • /
    • 2017
  • A cable tray is a structure made of metal or a non-combustible material that supports cables in the electrical wiring of buildings. Cable trays should be developed to meet the various requirements of the construction site. In this study, a design system was developed to calculate the maximum support load and the maximum deflection according to the cross-sectional shape of the cable tray. The cross-sections of cable trays were modeled by combining linear and arc elements, and cross-sectional characteristics such as the 2nd moment of area were calculated. The distributed load and the concentrated load were applied to the cable tray using the Euler beam theory, and then the deflection profiles and maximum stress were calculated. To verify the developed system, deflection distributions and maximum stresses for two types of cable trays were calculated and compared. The maximum deflection and maximum stress errors calculated from the developed system were found to be less than 4% compared with numerical analysis results.

Development and Working Efficiency of Supporting Program for the Parametric Electrical Outfit Production Design of Offshore Plant Based on PML (PML 기반 파라메트릭 해양플랜트 전장생산설계 지원 프로그램 개발 및 업무 효율성 연구)

  • Kim, Hyun-Cheol;Kim, Jong-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.205-213
    • /
    • 2019
  • Recently, because of the global recession of the offshore plant industry and low-cost orders, there has been increasing interest in strengthening the competitiveness of domestic companies for the design and production technologies of offshore plants. However, in the offshore plant design field, the Plant Design Management System (PDMS), which is a 3D CAD program for plant layout developed by AVEVA Marine, is already commonly used as offshore plant design software and widely used in large domestic shipyards and cooperative design companies. Under this background, we have been thinking about ways to design better with the existing software. In this study, we developed a parametric design program to maximize the efficiency and reduce the working time for offshore plant electrical outfit production design based on the Programmable Macro Language (PML) of PDMS. We also examined its performance. By applying the developed program to the offshore plant module selected as an application example, it was confirmed that a 50% improvement in the work efficiency of cable tray design could be obtained compared with the existing method, with work efficiency improvements of 80% or more in other field design work.

Roll Forming Analysis for All-in-one Cable Tray (일체형 케이블 트레이의 롤포밍 성형해석에 관한 연구)

  • Han, Myung-Chul;Sung, Chang-Min;Kim, Jung-Kwan;Gwon, Yu-Hong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.143-149
    • /
    • 2018
  • A cable tray is a fixture to support and protect electrical and communication cables. In this study, a roll-forming analysis is conducted to produce an all-in-one cable tray. The number of process stands is calculated using an empirical formula. By applying bending methods to the design of the roll flower pattern, the final process stands and forming angles are determined. The shape and stress variations in the cable tray are modeled and observed by roll forming analysis using LS-DYNA Software. The width of the side rail and the maximum stress on all stands does not exceed the reference values. The forming machine and rolls are manufactured based on the results of the roll forming analysis. In addition, all-in-one cable trays satisfy the National Electrical Manufacturers Association standards when they are manufactured according to this design.

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.