• Title/Summary/Keyword: 컴플라이언스 효과

Search Result 23, Processing Time 0.028 seconds

A Study on Security Container to Prevent Data Leaks (정보 유출 방지를 위한 보안 컨테이너의 효과성 연구)

  • Lee, Jong-Shik;Lee, Kyeong-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1225-1241
    • /
    • 2014
  • Recently, Financial companies implement DLP(Data Leaks Prevention) security products and enforce internal controls to prevent customer information leaks. Accidental data leaks in financial business increase more and more because internal controls are insufficient. Security officials and IT operation staffs struggle to plan countermeasures to respond to all kinds of accidental data leaks. It is difficult to prevent data leaks and to control information flow in business without research applications that handle business and privacy information. Therefore this paper describes business and privacy information flow on applications and how to plan and deploy security container based OS-level and Hypervisor virtualization technology to enforce internal controls for applications. After building security container, it was verified to implement internal controls and to prevent customer information leaks. With security policies additional security functions was implemented in security container and With recycling security container costs and time of response to security vulnerabilities was reduced.

A Study on Data Security Control Model of the Test System in Financial Institutions (금융기관의 테스트시스템 데이터 보안통제 모델 연구)

  • Choi, Yeong-Jin;Kim, Jeong-Hwan;Lee, Kyeong-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1293-1308
    • /
    • 2014
  • The cause of privacy extrusion in credit card company at 2014 is usage of the original data in test system. By Electronic banking supervision regulations of the Financial Supervisory Service and Information Security business best practices of Finance information technology (IT) sector, the data to identify the customer in the test system should be used to convert. Following this guidelines, Financial firms use converted customer identificaion data by loading in test system. However, there is some risks that may be introduced unintentionally by user mistake or lack of administrative or technical security in the process of testing. also control and risk management processes for those risks did not studied. These situations are conducive to increasing the compliance violation possibility of supervisory institution. So in this paper, we present and prove the process to eliminate the compliance violation possibility of supervisory institution by controlling and managing the unidentified conversion customer identification data and check the effectiveness of the process.

Research Trends in Economic Effects of Information Security Certification: Focused on the ISMS (Information Security Management System) (보안인증의 경제적 효과에 대한 연구동향 분석: ISMS(정보보호관리체계)를 중심으로)

  • Kong, Hee-Kyung;Jun, Hyo-Jung;Lee, Song-Ha;Kang, Min-Seong;Kim, Tae-Sung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.3
    • /
    • pp.821-835
    • /
    • 2016
  • This study investigates the domestic and international research trends to analyze the economic effects of various information security certification systems. Results of the study can suggest future research topics for researchers, and help make rational decision-making on introducing information security management systems for practitioners.

정보보호 관리체계 도입의 필요성 고찰 (특허정보제공 기업을 중심으로)

  • Kang, Youn-Chul;Rim, Seongtaek
    • Review of KIISC
    • /
    • v.23 no.4
    • /
    • pp.7-14
    • /
    • 2013
  • 영업비밀 관련 또는 특허문제로 소송이 빈번하게 발생하는 요즘 특허 전쟁에 있어서도 해당 정보를 적절하게 보호하고 유지하기 위한 특허정보 관리체계에 있어서의 정보보안은 매우 중요한 요인으로 인식되고 있다. 이러한 상황에서 보안사고가 발생했을 경우, 이에 효과적으로 대응하기 위한 방안들에 대해 기업 전반에 걸쳐 인지될 필요성 또한 부각되고 있으며 이를 가능하게 해주는 방안으로 국제인증 기준이 떠오르고 있다. 각종 정보보호의 중요성에 따른 기업 관리시스템들이 이러한 인증체계를 도입 및 운영하고 있는 추세이며 이를 뒷받침 해주기 위해 특허법을 비롯하여 관련 컴플라이언스를 준수하기 위한 개인정보보호법(안전성 확보조치), 정보통신망 이용촉진 및 정보보호 등에 관한 법률과 같은 정보보호 법률을 기준으로 제시할 수 있다. 사례 기업에서는 이 중 정보보호 국제인증의 대표격인 ISO27001을 바탕으로 현재 특허관련 기업에 필요한 정보보호관리체계를 정립 및 적용하였다. 해당 정보보호 관리체계는 특허관련 업무분장에서 주요하게 다루어지지 않았던 기술적, 관리적, 물리적 보안에 대한 부적합사항을 충족시키고 특허정보보호업무, 감사업무, 검사업무, 전산운영 등 분산된 업무를 일관된 업무로 통합하는 효과적인 관리체계가 될 수 있음을 제시하였다.

Static and Dynamic Fracture Toughness Evaluation in SiCp/6061Al Composite (SiCp/6061Al복합재료의 정적 및 동적파괴인성 평가)

  • An, Haeng-Geun
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.565-570
    • /
    • 1998
  • SiCp/6061AI 복합재료의 파괴인성을 평가하기 위하여 정적파괴인성에 대해서는 복수시험편법을, 동적파괴인성시험에 대해서는 stop block법을 실시하였다. 주균열은 예비균열의 선단에서 시험편두께방향 전역에 걸쳐서 일시에 발생하는 것이 아니고, 균열발생의 초기단계에서 국부적으로 형성된 균열이 시험편두께방향으로의 균열의 확장을 완료한 후 주균열로 이행해 간다. 정적 및 동적시험에서 컴플라이언스변화율법에 의해 검출된 균열발생점은 균열확장의 완료점과 거의 일치하고 있기 때문에 본 재료의 파괴인성 결정에 유효하다. 본 재료에서 동적파괴인성치는 정적파괴인성치보다 크게 나타났다. 이것은 동적충격시 입자파괴에 의한 에너지의 흡수.분산효과와 균열진전경로의 큰 편향에 기인한다고 생각된다.

  • PDF

The Study on the Mechanical Behavior of the Anastomosis with respect to the Thickness Variation of Elastic Foundation Using Simplified Suturing Model (단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 기계역학적 거동에 관한 연구)

  • 이성욱;한근조;심재준;한동섭;김태형
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper we analyzed the mechanical behavior with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(CA) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100mmHg(13.3㎪). And Equivalent and circumferential stresses in the anastomosis were also analyzed with respect to the change of initial diameter ratio( $R_1$) and fatty tissue thickness( $T_{F}$). The results obtained were as follows : 1 When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was reduced by 47 -72%. 2. As the initial diameter ratio( $R_1$) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts. 3. The maximum nondimensional circumferential stress is twice or three times as high as the maximum nondimensional equivalent stress in the anastomotic part.t.

Review of POGO and PSD (POGO와 PSD의 소개)

  • 고광웅;이한주;정동운;이상용
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.1-9
    • /
    • 2003
  • To reduce the possibility of longitudinal dynamic instability, called "POGO", in the liquid rocket system due to the feedback effect of a main structure and a fuel-feeding system, several different types of PSD(POGO Suppression Device) systems have been studied. In the present study, several different types of PSD were reviewed. Basically, all PSD systems can be categorized into two groups; a passive PSD or an active PSD. We can classify the passive PSD's into more detailed groups according to their compliance methods; localized compliance methods or distributed compliance methods. As a result of our intensive review on various PSD's, the gas-filled accumulator with a level control system is considered to be the most suitable one to suppress the POGO instability without mal-effects to the performance of a fuel-feeding system.ng system.

A Study on HIGH TEMPERATURE FRACTURE TOUGHNESS of Pressure Vessel Steel SA516 at High Temperature. (압력용기용강의 고온파괴인성에 관한 연구)

  • 박경동;김정호
    • Proceedings of the KWS Conference
    • /
    • 2001.05a
    • /
    • pp.228-231
    • /
    • 2001
  • Elastic-plastic fracture toughness $J_{1c}$ can be used as an effective design criterion in elastic plastic fracture mechanics. Most of these systems are operated at high temperature and $J_{1c}$ values are affected by temperature. therefore, the $J_{1c}$ valuse at high temperature must be determined for use of integrity evaluation and designing of such systems. Elastic-plastic fracture toughness $J_{1c}$ tests were performed on SA516 carbon steel plate and test results were analyzed according to ASTM E 813-8, ASTM 1813-89. Safety and integrity are required for reactor pressure vessels vecause pthey are operated in high temperature. there are single specimen method, which used as evaluation of safety and integrity for reactor pressure vessels. In this study, elastic-plastic fracture toughness$(J_{1c})$ and $J-\Delta{a}$ of SA 516/70 steel used as reactor pressure vessel steel are measured and evaluated at room Temperature, $150^{\circ}C$, $250^{\circ}C$ and $370^{\circ}C$ according to unloading compliance method.

  • PDF

Evaluation on High Temperature Fracture toughness of Pressure Vessel SA516/70 Steel (압력용기용 SA516/70강의 고온파괴인성평가)

  • 박경동;김정호;윤한기;박원조
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.99-104
    • /
    • 2001
  • Elastic-plastic fracture toughness $J_{lc}$ can be used as an effective design criterion in elastic plastic fracture mechanics. Most of these systems are$J_{lc}$ $J_{lc}$ value at high temperature must be determined for use of integrity evaluation and designing of such systems. Elastic-plastic fracture toughness $J_{lc}$ tests were performed on SA516/70 carbon steel plate and test results were analyzed according to ASTM E 813-87, ASTM E 813-89 and ASTM E 1152-87.safety and integrity are required for reactor pressure vessels because, they are operated in high temperature. There are single specimen method, which used as evaluation of safety and integrity for reactor pressure vessels. In this study, elastic-plastic fracture toughness($J_{lc}$) and J-$\Delta$a of SA 516/70 steel used as reactor pressure vessel steel are measured and evaluated at room temperature, 150$^{\circ}C $, 250$^{\circ}C $ and 370$^{\circ}C $ according to unloading compliance method.

  • PDF

Structural Behavior on the Externally Strengthened Bridge Deck with Glass Fiber Reinforced Polymer (유리섬유보강재로 외부부착 보강된 교량 바닥판의 구조거동)

  • 오홍섭;심종성;최장환
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.922-933
    • /
    • 2002
  • Since the deterioration of concrete bridge decks affect durability, safety, and function, structural rehabilitation of damaged concrete deck that was strengthened with Fiber Reinforced Polymer(FRP) is increasing the latest. But recent studies on the strengthened structures are focused on the static behavior, however only a few studies on the fatigue behavior are performed. In this study, static and fatigue behavior of strengthened deck were peformed on 11 deck specimens strengthened with sheet typed Glass Fiber Reinforced Polymer(GFRP) that were reinforced by two different strengthening methods for the static test. A amount of strengthening material in the each direction such as transverse and longitudinal was adopted experimental variables for the static test and also the stress level of the static maximum load are adopted for the fatigue test. By the results of the experimental study, with respect to the strengthened decks, the resistance effect of crack propagation and effect of stress distribution are improved. In addition, the rate of variation of compliance decreased.