• Title/Summary/Keyword: 컴퓨터 단층 촬영

Search Result 630, Processing Time 0.032 seconds

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

Added Value of Magnetic Resonance Imaging in Staging of Malignant Pleural Mesothelioma (악성흉막중피종의 병기판정에서 자기공명영상의 진단적 유용성 평가)

  • Lee, Eunsol;Chae, Eun Jin;Kang, Sunji;Yeom, Yoo Kyeong;Lee, Hyun Joo;Park, Jong Chun;Shin, So Youn;Choi, Yoon Young;Choi, Joon Ho;Do, Kyung-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.232-238
    • /
    • 2013
  • Purpose : We investigated the possible added value of magnetic resonance imaging (MR) in staging of malignant pleural mesothelioma (MPM) compared to computed tomography (CT). Materials and Methods: We retrospectively enrolled 20 patients (M;F = 14:6; mean age, 53.5 yrs) who diagnosed as MPM by histology and underwent CT and MR at initial evaluation from Jan 1997 to Dec 2012. Two radiologists performed clinical staging by using CT alone or MR alone in consensus. In patients underwent surgery (n = 13), we evaluated the diagnostic accuracy of CT and MR in terms of staging compared to surgical staging. In all patients, we compared clinical staging of CT only and CT with MR. Results: The diagnostic accuracy for T staging of CT only was 23.1% (3/13) and that of combined CT and MR was 38.5% (5/13), respectively. Among 13 patients underwent surgery, surgical stage was higher than combined CT and MR stage in 5 patients, but lower in 3 patients. CT only and combined CT and MR agreed in 85.0% (17/ 20). In cases of disagree (15.0%, 3/20), combined CT and MR showed higher stage than CT only. Conclusion: Combined CT and MR increases the diagnostic accuracy in staging of MPM compared to CT only and is important in determining the appropriate treatment in patients being considered for surgery.

Finite element analysis of the effects of mouthguard produced by combination of layers of different materials on teeth and jaw (다양한 물성을 혼용하여 제작된 구강보호장치가 치아 및 악골에 미치는 영향)

  • So, Woong-Seob;Lee, Hyun-Jong;Choi, Woo-Jin;Hong, Sung-Jin;Ryu, Kyung-Hee;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.324-332
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the stress distribution of teeth and jaw on load by differentiating property of materials according to each layer of widely used mouthguard. Materials and methods: A Korean adult having normal cranium and mandible was selected to examine. A customized mouthguard was constructed by use of DRUFOMAT plate and DRUFOMAT-TE/-SQ of Dreve Co. according to Signature Mouthguard system. The cranium was scanned by means of computed tomography with 1mm interval. It was modeled with CANTIBio BIONIX/Body Builder program and simulated and interpreted using Alter HyperMesh program. The mouthguard was classified as follows according to the layers. (1) soft guard (Bioplast)(SG) (2) hard guard (Duran)(HG) (3) medium guard (Drufomat)(MG) (4) soft layer + hard layer (SG + HG) (5) hard layer + soft layer (HG + SG) (6) soft layer + hard layer + soft layer (SG + HG + SG) (7) hard layer + soft layer + hard layer (HG + SG + HG) The impact locations on mandible were gnathion, the center of inferior border, and the anterior edge of gonial angle. And the impact directions were oblique ($45^{\circ}$). The impact load was 800 N for 0.1 sec. The stress distribution was measured at maxillary teeth, TMJ and maxilla. The statistics were conducted using Repeated ANOVA and in case of difference, Duncan test was used as post analysis. Results: In teeth and maxilla, the mouthguard contacting soft layer of mandibular teeth presented lowest stress measure and, in contrast, in condyle, the mouthguard contacting hard layer of mandibular teeth presented lowest stress measure. Conclusion: For all impact directions, soft layer + hard layer + soft layer, the mouthguard with three layers which the hard layer is sandwiched between two soft layers, showed relatively even distribution of stress in impact.

ORTHODONTIC TRACTION OF HORIZONTALLY ERUPTED LOWER LATERAL INCISOR ON THE LINGUAL SIDE (설측으로 수평 맹출한 하악 측절치의 교정적 견인)

  • Mah, Yon-Joo;Sohn, Hyung-Kyu;Choi, Byung-Jai;Lee, Jae-Ho;Kim, Seong-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.117-123
    • /
    • 2010
  • Tooth eruption is the movement of the tooth from the developing place in the alveolar bone to the functional position in the oral cavity. The permanent incisors originate from the dental lamina on the lingual side of preceding deciduous tooth and erupt to the level of the occlusion through the well developed gubernacular cord. Ectopic eruption is a developmental disturbance in the eruption pattern of the permanent dentition. Most of the ectopically erupted lower incisor has been found in lingual side. The ectopically erupted tooth could be repositioned by orthodontic force in the early mixed dentition, which could help preventing the problems of loss of space and the lingual tilting of the lower anterior teeth. An eight-year-old girl visited the department of pediatric dentistry, Yonsei Dental University Hospital, for the evaluation and the treatment of the lower right lateral incisor, which was horizontally erupted in the lingual side, parallel to the mouth floor. Her tongue was placed on the labial side of that tooth. There was no previous dental history of dental caries or trauma on the pre-occupied primary incisor. Clinical and radiographic examinations including the computed tomography(CT), showed no evidence of dilacerations on root. Therefore, we decided to start active orthodontic traction of the lower right lateral incisor. We designed the fixed type of buccal arch wire and the lip bumper with hook for the traction. Button was attached to the lingual side of the ectopically positioned tooth. Elastic was used between the appliance and the button on that tooth. After the tooth become upright over the tongue level, appliance was change to the removable type and periodic check-up with occlusal guidance was followed to monitor the position of the tooth. In this case using the fixed appliance with modified form of lip bumper and hook embedded in acrylic part instead of extraction was very efficient up-righting the ectopically erupted tooth toward the occlusal plane.

Latarjet Operation for Anterior Shoulder Instability with Glenoid Bone Defect (관절와 골 결손을 동반한 견관절 전방 불안정증에 대한 Latarjet 술식)

  • Cho, Seung-Hyun;Cho, Nam-Su;Yi, Jin-Woong;Choi, Il-Hun;Kwack, Yoon-Ho;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • Purpose: We wanted to evaluate the clinical results of the Latarjet procedure for treating anterior shoulder instability combined with a glenoid bone defect. Materials and Methods: Between Oct. 2006 and May. 2007, fourteen patients underwent a Latarjet operation to treat their anterior shoulder instability combined with a glenoid bone defect. The mean follow-up period was 15 months (range: 12 to 19 months), and the average age at the time of surgery was 29.9-years-old (range: 19 to 44 years). There were 13 males and 1 female. Eight patients exhibited involvement of the right shoulder. The dominant arm was involved in 8 patients. Six patients had undergone a previous arthroscopic Bankart repair before their Latarjet operation and 2 patients had a history of seizure. Results: The average Rowe score improved from 51.8 to 80.2 with 9 excellent, 4 good, and 1 fair results. The average Korean shoulder score for instability improved from 61.6 to 82.1 postoperatively. The active forward flexion and external rotation at the side of the involved shoulder was an average of $8^{\circ}$ and $16^{\circ}$ less than that of the uninvolved shoulder. The muscle strength of the involved shoulder measured 78.7% in forward flexion and 82.5% in external rotation, as compared with that of the uninvolved shoulder. There was 1 case of dislocation, 1 transient subluxation, 2 fibrotic unions, 1 resorption of the transferred coracoid process, 1 intraoperative broken bone, 1 transient musculocutaneous nerve injury and 1 case of stiffness. Conclusion: The Latarjet procedure for treating anterior shoulder instability combined with a significant glenoid defect effectively restores function and stability through extending the articular arc at the expense of external rotation. We should be cautious to avoid or detect complications when performing coracoid transfer.

Comparison of the Mid-term Changes at the Remnant Distal Aorta after Aortic Arch Replacement or Ascending Aortic Replacement for Treating Type A Aortic Dissection (A형 급성대동맥박리증에서 대동맥궁치환술과 상행대동맥치환술 후 잔존 원위부 대동맥의 변화에 대한 중기 관찰 비교)

  • Cho, Kwang-Jo;Woo, Jong-Su;Bang, Jung-Hee;Choi, Pill-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.414-419
    • /
    • 2007
  • Background: Replacing the ascending aorta is a standard surgical option for treating acute type A aortic dissection. But replacing the aortic arch has recently been reported as an acceptable procedure for this disease. We compared the effects of aortic arch replacement for treating acute type A aortic dissection with the effects of ascending aortic replacement. Material and Method: From 2002 to 2006, 25 patients undewent surgical treatment for acute type A aortic dissection, 12 patients undewent ascending aortic replacement and 13 patients underwent aortic arch replacement. Among the aortic arch group, an additional distal stent-graft was inserted during the operation in 5 patients. 19 patients (11 arch replaced patients and 8 ascending aortic replaced patients) were followed up at the out patient clinic for an average of $756{\pm}373$ days. All the patients undewent CT scanning and we analyzed their distal aortic segments. Result: 4 patients who underwent ascending aortic replacement died, so the overall mortality rate was 16%. Among the 11 long term followed-up arch replacement patients, 2 patients (18.1 %) developed distal aortic dilatation and one of them underwent thoracoabdominal aortic replacement later on. However, among the 8 the ascending aortic replaced patients, 5 patients (62.5%) developed distal aortic dilatation. Conclusion: Aortic arch replacement is one of the safe options for treating acute type A aortic dissection. Aortic arch replacement for treating acute type A aortic dissection could contribute to a reduced distal aortic dilatation rate and fewer secondary aortic procedures.

A Suggested New Clinical Classification for Pediatric Intussusception (소아 장중첩증의 새로운 임상적 분류의 제안)

  • Park, Moon Ho;Shon, Su Min;Choe, Byung Kyu;Kim, Yeo Hyang;Lee, Hee Jung;Choi, Won Joung;Kim, Ae Suk;Hwang, Jin-Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 2006
  • Purpose: We proposed a new classification of pediatric intussusception based on clinical and radiologic findings. Methods: Data from 88 consecutive patients with intussusception were reviewed. We retrospectively analyzed six factors; patient age, sites of intussusception, symptoms, therapeutic methods, existence of enlarged mesenteric lymph nodes, and ultrasonographic (US) findings from clinical records. Results: 1) There was one neonatal case (1.1%), the others (98.9%) were infants and children. 2) These 87 infant and child cases consisted of 14 cases (16.1%) of small bowel intussusception (SBI) and 73 cases (83.9%) of ileo-colic intussusception (ICI). Of the 14 SBI cases, 12 cases were symptomatic and 2 cases were asymptomatic. The symptomatic group comprised 8 transient cases (66.7%), 3 operative cases (25.0%), and 1 enema-reduction case (8.3%). Two asymptomatic cases were incidentally captured by computed tomography. Of the 73 ICI cases, 19 cases (26.0%) required operation, and 54 (74.0%) enema-reduction. 3) When transient SBI cases were compared with operated SBI cases, enema-reduced and operated ICI cases, the age ($38.0{\pm}22.9$ months) of transient SBI cases were significantly higher than those of the others (p=0.003). Mean mass size ($20.8{\pm}2.7mm$) in transient SBI was significantly smaller than in the others (p=0.0001). 4) No correlation was found between the existence of enlarged mesenteric lymph nodes and therapeutic method or concomitant illness. 5) Most of the target types observed by US were in transient SBI cases, the remainder were in the enema-reduced ICI cases. In terms of the doughnuts type, all 8 cases (34.8%) with an external hypoechoic rim thickness of >8.9mm were treated surgically. Conclusion: Pediatric intussusception may be classified based on clinical and radiologic findings, which are likely to indicate appropriate therapies.

  • PDF

Study of the Production Techniques Used in the Goryeo-period Gilt-Bronze Case for Acupuncture in the Collection of the Royal Museums of Art and History, Belgium (벨기에 왕립예술역사박물관 소장 고려시대 금동침통의 과학적 보존처리를 통한 제작기법 연구)

  • Lee, Jaesung;Park, Younghwan
    • Conservation Science in Museum
    • /
    • v.27
    • /
    • pp.147-164
    • /
    • 2022
  • Over 200,000 Korean cultural heritage items are currently located abroad. They have made their way to 22 countries under different circumstances and with unique backgrounds. While some of them continue to contribute to promoting Korean culture around the world, others cannot be exhibited due to damage or poor condition. In view of these circumstances, the Overseas Korean Cultural Heritage Foundation (OKCHF) has since 2013 provided museums and art galleries abroad with support for the conservation, restoration, and utilization of the Korean cultural heritage items that they house. As a part of these efforts and on the occasion of the 120th anniversary of the diplomatic relationship between the Republic of Korea and the Kingdom of Belgium in 2021, a gilt-bronze case for acupuncture needles dating to the Goryeo period (918-1392) from the collection of the Royal Museums of Art and History (RMAH), Belgium was brought to Korea for conservation treatment. The primary purpose of this conservation treatment was to restore the original form of the relic and slow to the degree possible the progress of corrosion. The conservation treatment of the gilt-bronze case followed the fundamental order of conservation treatment: removal of corrosive substances, stabilization, and reinforcement. Since this was the first case of restoring metallic cultural properties under the abovementioned support program by the OKCHF, special methodologies distinct from those available in overseas institutions were required. Diverse scientific methods (e.g., X-ray inspection, CT scanning, 3D microscopy) were applied to identify the metalcraft techniques used in the Goryeo period. The analysis found that several designs, including lotus and scrollwork, were exquisitely engraved on the surface of the case by making dots using a round-edged chisel. A bronze plate engraved with designs was rolled into a cylindrical form. The ends were overlapped by 2 to 3 centimeters and then attached to each other by silver soldering. The overlapping ends were welded flat with nearly no gaps. As the final process in the production, the case was lavishly gilt with gold powder using amalgam gilding. The conservation treatment of the gilt-bronze case for acupunctural needles in the RMAH collection restored the original form of the relic and arrested further corrosion. Above all, it revived the historic and academic value of the overseas Korean cultural heritage through scientific analysis.

External Tibial Torsion with Proximal Tibia Vara in Total Knee Arthroplasty of Advanced Osteoarthritis with Severe Varus Deformed Knees (심한 내반 변형의 진행성 관절염 환자의 인공 슬관절 전치환술 시 경골 근위부의 내반을 동반한 외회전 변형)

  • Sun, Doo-Hoon;Song, In-Soo;Kim, Jun-Beom;Kim, Cheol-U;Jung, Deukhee;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.62-70
    • /
    • 2020
  • Purpose: External tibia torsion and proximal tibial vara have been reported in severe varus deformed osteoarthritis, which is a tibio-femoral angle of more than 20°. The radiology measurements were compared with those of control group and the preoperative and follow-up radiology and clinical results were examined. Materials and Methods: From January 2007 to March 2016, 43 knees from 37 persons, who underwent total knee arthroplasty for a severe varus deformity of more than 20° on the tibio-femoral angle on the standing radiographs and had a follow-up period more than two years, were examined. The mean follow-up period was 45.7 months. The control group, who underwent conservative treatments, had Kellgren-Lawrence grade three osteoarthritis and a tibio-femoral angle of less than 3° varus. The external tibial torsion of enrolled patients and control group were estimated using the proximal tibio-fibular overlap length and the tibial torsion values on computed tomography. The proximal tibia vara was measured using the proximal tibial tilt angle. The preoperative and postoperative proximal tibio-fibular overlap length, tibial torsion value, proximal tibial tilt angle, and hospital for special surgery (HSS) score were evaluated. Results: The mean proximal tibio-fibular overlap length was 18.6 mm preoperatively and 11.2 mm (p=0.031) at the follow-up. The control group had a mean proximal tibio-fibular overlap length of 8.7 mm (p=0.024). The mean tibial torsion value was 13.8° preoperatively and 14.0° (p=0.489) at the follow-up. The control group had a mean tibial torsion value of 21.9° (p=0.012). The mean proximal tibial tilt angle was 12.2° preoperatively and 0° (p<0.01) at the follow-up. The control group had a mean proximal tilt angle of 1.2° (p<0.01). The preoperative tibiofemoral angle and mechanical axis deviation were corrected from preoperative 28.3° and medial 68.4 mm to postoperative 0.7° and medial 3.5 mm (p<0.01, p<0.01), respectively. The HSS scores increased from 34 points of preoperatively to 87 points at the last follow-up (p=0.028). Conclusion: Patients with advanced osteoarthritis with a severe varus deformity of more than 20° had significant increases in the external tibial torsion and varus of the proximal tibia. The tibial torsion value before and after surgery in the enrolled patients was not changed statistically, but good clinical results without complications were obtained.

Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis (요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰)

  • Kwon, Ji-Won;Kim, Jin-Gyu;Ha, Joong-Won;Moon, Seong-Hwan;Lee, Hwan-Mo;Park, Yung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.405-410
    • /
    • 2020
  • Purpose: Pedicle screw insertion has been traditionally used as a surgical treatment for degenerative lumbar spine disease. As an alternative, the cortical-bone trajectory screw allows less invasive posterior lumbar fixation and excellent mechanical stability, as reported in several biomechanical studies. This study evaluated the clinical and radiological results of a case of early failure of cortical-bone screw fixation in posterior fixation and union after posterior decompression. Materials and Methods: This study examined 311 patients who underwent surgical treatment from 2013 to 2018 using cortical orbital screws as an alternative to traditional pedicle screw fixation for degenerative spinal stenosis and anterior spine dislocation of the lumbar spine. Early fixation failure after surgery was defined as fixation failure, such as loosening, pull-out, and breakage of the screw on computed tomography (CT) and radiographs at a follow-up of six months. Results: Early fixation failure occurred in 46 out of 311 cases (14.8%), screw loosening in 46 cases (14.8%), pull-out in 12 cases (3.9%), and breakage in four cases (1.3%). An analysis of the site where the fixation failure occurred revealed the following, L1 in seven cases (15.2%), L2 in three cases (6.5%), L3 in four cases (8.7%), L4 in four cases (8.7%), L5 in four cases (8.7%), and S1 in 24 cases (52.2%). Among the distal cortical bone screws, fixation failures such as loosening, pull-out, and breakage occurred mainly in the S1 screws. Conclusion: Cortical-bone trajectory screw fixation may be an alternative with comparable clinical outcomes or fewer complications compared to conventional pedicle screw fixation. On the other hand, in case with osteoporosis and no anterior support structure particularly at L5-S1 fusion sites were observed to have result of premature fixation failures such as relaxation, pull-out, and breakage.