픽셀 단위 컨볼루션 네트워크를 이용한 복부 컴퓨터 단층촬영 영상 기반 골전이암 병변 검출 알고리즘 개발 (Development of Bone Metastasis Detection Algorithm on Abdominal Computed Tomography Image using Pixel Wise Fully Convolutional Network)

  • 김주영;이시영;김규리;조경원;유승민;소순원;박은경;조백환;최동일;박훈기;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권6호
    • /
    • pp.321-329
    • /
    • 2017
  • This paper presents a bone metastasis Detection algorithm on abdominal computed tomography images for early detection using fully convolutional neural networks. The images were taken from patients with various cancers (such as lung cancer, breast cancer, colorectal cancer, etc), and thus the locations of those lesions were varied. To overcome the lack of data, we augmented the data by adjusting the brightness of the images or flipping the images. Before the augmentation, when 70% of the whole data were used in the pre-test, we could obtain the pixel-wise sensitivity of 18.75%, the specificity of 99.97% on the average of test dataset. With the augmentation, we could obtain the sensitivity of 30.65%, the specificity of 99.96%. The increase in sensitivity shows that the augmentation was effective. In the result obtained by using the whole data, the sensitivity of 38.62%, the specificity of 99.94% and the accuracy of 99.81% in the pixel-wise. lesion-wise sensitivity is 88.89% while the false alarm per case is 0.5. The results of this study did not reach the level that could substitute for the clinician. However, it may be helpful for radiologists when it can be used as a screening tool.

컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가 (Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom)

  • 김기원;최관우;정회원;장서구;권경태;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.193-198
    • /
    • 2016
  • 임상적으로 computed tomography (CT)에서 정기적인 quality assurance (QA)는 요구되는 사항이다. 본 논문에서는 CT 검사에서 공간분해능에 대해서 AAPM Phantom을 이용하여 정확한 성능 분석을 위해 변조전달함수를 평가하고자 한다. CT장비는 dual source somatom definition flash (siemens healthcare, forchheim, Germany), brilliance 64 (phili ps m edi cal system N etherlands), a qui li on 64 (toshiba m edi cal system, Japan)를 사용하였으며, l mage J (wayne rasband national institutes of health, USA)프로그램을 실행하여 변조전달함수의 측정 방법인 chart method를 이용하여 영상에 대해서 정량적인 평가방법을 시행하였다. 변조전달함수를 이용하여 평가한 결과, 공간주파수를 이용한 데이터 값이 높아짐에 따라 변조전달함수는 감소됨을 알 수 있었다. 그리고 CT 장비에서 변조전달함수는 공간주파수(50%)에 있어서는 0.58, $0.28\;0.59mm^{-1}$으로 나타났으며, 변조전달함수 공간주파수(10%)에 있어서는 1.63, $0.89\;1.21mm^{-1}$으로 나타났다. 본 연구에서는 chart method를 이용하여 변조전달함수의 공간해상력에 대한 특성을 확인하고, 정량적인 평가방안을 제시하였다는 점에서 학술적 의의를 둘 수 있다.

개에서 컴퓨터단층영상의 3차원 재구성을 통한 환축추골 아탈구 진단 3례 (3-Dimensional Computed Tomography of Atlantoaxial Instability in Three Dogs)

  • 안세준;최수영;임수지;안지영;이인;권영항;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제26권5호
    • /
    • pp.490-494
    • /
    • 2009
  • A 2-year-old Maltese and a 5-month-old Yorkshire terrier were presented with ataxia. Tetraparesis was observed in a 9-year -old Yorkshire terrier. The localizations of the lesions suggested brain or cervical spinal cord by the neurological examination, and the following images was achieved: radiography, axial images of computed tomography (CT), reconstruction image of CT such as multi-planar reformation(MPR) and 3-dimensional(3D) reconstruction and magnetic resonance imaging (MRI). On radiography, the misalignment between atlas (C1) and axis (C2), absent dens of axis, and increased space between the dorsal arch of C1 and spinous process of C2 were found. The discontinuation between dens and body of C2 was identified through axial CT images, and the fragmentation of dens separated from axis was observed through MPR and 3D image in all case. The hyperintense lesions and the spinal cord compression on T2-weighted MR images were represented in a dog with tetraparesis, the others represented only spinal cord compression. Three dogs were diagnosed as atlantoaxial instability (AAI) by dens fracture of C2. The dog with tetraparesis was euthanized due to guarded prognosis. The others were recovered completely. It is difficult to differentiate dens fracture of C2 from abnormal dens such as agenesis and hypoplasia. We thought that CT is very useful to evaluate the dens of C2 and differentiate the causes of AAI, and the reconstruction images of CT such as MPR and 3D make the translation of the fragmented dens or axis of AAI more precisely evaluate.

비글견의 컴퓨터단층영상에서 기관내강과 폐동맥 직경비율의 마취제에 따른 영향평가 (Influences of Anesthetics in term of Computed Tomography Bronchial Lumen to Pulmonary Artery Diameter Ratio in Beagle Dogs)

  • 임종수;황태성;윤영민;정동인;연성찬;이희천
    • 한국임상수의학회지
    • /
    • 제33권1호
    • /
    • pp.6-9
    • /
    • 2016
  • Bronchoarterial (BA) ratio is a commonly used criterion to define airway dilatation despite the lack of normative human and animals. The objective of our study was to compare the range of normal bronchial to accompanying arterial diameter ratio with previous reports on CT scan of the thorax in dogs and assess influence anesthetics on BA ratio in dogs. Dogs undergoing multidetector CT scan of the chest for nonpulmonary conditions at a single center were prospectively identified. High-resolution reconstruction was performed on those included and both airway lumen and vessel diameters were measured in the lobar bronchi of the left cranial (cranial and caudal parts), right cranial, right middle, left caudal, and right caudal lung lobes. Eight dog were included; Mean of the mean BA ratios was $1.43{\pm}0.24$ (95% CI = 1.36 - 1.50) in inhalation anesthetic group. In propofol group, the mean of the mean BA ratios was $1.13{\pm}0.29$ (95% CI = 1.04 - 1.22). In medetomidine group, the mean of the mean BA ratios was $0.89{\pm}0.19$ (95% CI = 0.83 - 0.95). Comparing individual lobes within anesthetic category, there was no signicant difference in mean BA ratio between lung lobes or between dog according to inhalation, propofol, and medetomidine group (P = 0.630, P = 0.878, and P = 0.508, respectively). The BA ratio in these clinically normal dogs was consistent and may be a useful tool in evaluating for bronchiectasis on CT images. However, some different criteria for bronchiectasis were applied by the anesthetic methods.

제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 근위 상완골 골절 - 1예 보고 - (Recurrent Shoulder Dislocation and Proximal Humerus Fracture in Neurofibromatosis Type I - A Case Report -)

  • 황태혁;조형래;왕태현;양희순
    • Clinics in Shoulder and Elbow
    • /
    • 제16권2호
    • /
    • pp.135-140
    • /
    • 2013
  • 제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 동반된 근위 상완골 골절 1예를 보고하고자 한다. 제 1형 신경 섬유종증으로 진단된 20세 남자로 가벼운 외상 후 발생한 우측 견관절의 탈구와 근위 상완골 골절로 내원하였다. 수상측 주관절부에는 큰 망상형 신경 섬유종들이 있었으며 견관절 탈구는 재발성 병변이었다. 단순 방사선과 컴퓨터 단층 촬영 소견 상 상완골과 견갑골의 골성 변형을 보였고 자기 공명 영상 검사 상 삼각근과 회전근 개에 다발성 신경 섬유종성 변화가 관찰되었다. 관혈적 정복술 및 관절막 재건술을 시행하였으며 근위 상완골 골절은 재건 금속판을 이용하여 고정하였다. 골유합과 만족스런 기능 회복을 보였으며 수술 후 7개월 추시 상 견관절 탈구의 재발은 관찰되지 않았다. 제 1형 신경 섬유종증 환자에서 발생한 견관절 재발성 탈구와 근위 상완골 골절은 드문 합병증이나 질환의 정형외과적 접근 시 고려해야 할 것으로 사료된다.

고양이에서 장 병변을 가진 고양이 전염성 복막염 감염 증례 (A Case of Feline Infectious Peritonitis with Intestinal Manifestation in a Cat)

  • 오현정;손정민;정선영;김보은;지서연;정주현;김대용;윤화영;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제31권5호
    • /
    • pp.449-453
    • /
    • 2014
  • 복강 내 종괴 촉진 및 구토, 식욕부진, 발열, 체중 감소, 수면시간 증가를 보이는 한 마리의 고양이가 서울대학교 부속 동물병원에 내원하였다. 신체검사, 혈액검사와 더불어 영상학적 검사가 진행되었다. 복부 초음파, CT 검사를 통해 소장분절과 연결된 종괴가 확인되었으며, 종괴에 대한 세포학적 검사 결과 소화기 림프종으로 잠정 진단되었으며 이에 따른 항암치료가 이뤄졌다. 항암치료가 진행되는 동안 증상은 호전되지 않았고, 결국 항암치료 중단 6일 후 폐사하였다. 부검이 이뤄졌으며 최종적으로 병변은 조직병리학적 검사를 통해 고양이 전염성 복막염으로 확진하였다.

개에서 발생한 십이지장 샘암종 (Imaging Features of Duodenal Adenocarcinoma in a Dog)

  • 정미애;이민수;이인혜;이아라;박수원;임채영;박희명;엄기동
    • 한국임상수의학회지
    • /
    • 제27권5호
    • /
    • pp.593-599
    • /
    • 2010
  • 7년령의 중성화한 수컷 Basset hound 가 식욕부진, 체중 감소, 혈변, 구토의 증상을 4개월 동안 보이며 내원하였다. 혈액 검사상, 소적혈구성, 저색소성 빈혈을 보였으며, 그 외 임상검사 소견은 정상이었다. 방사선 단순 촬영 시연부 조직 음영이 증가 된 것을 우측 상복부에서 관찰할 수 있었으며, 초음파와 컴퓨터 단층 촬영에서는 내림 십이지장의 벽이 전반적으로 비후되어 있는 것을 확인할 수 있었다. 생검을 통해 조직의 만성 염증 소견과 점막밑까지 침투되어있는 증식된 점막과 다수의 작은 샘과 같은 구조들을 확인하였고, 장샘암종을 확진 하였다. 13개월 동안의 대증치료 후에 환자는 폐사하였다. 본 증례는 개에서 드문 십이지장 샘암종의 임상학적, 영상진단학적, 조직병리학적 검사와 그 결과에 대해 기술하고자 한다.

여러 통상적인 전뇌방사선치료 기법에서의 정상조직의 조사선량 비교 (Comparison of the Dose of the Normal Tissues among Various Conventional Techniques for Whole Brain Radiotherapy)

  • 강민규
    • Radiation Oncology Journal
    • /
    • 제28권2호
    • /
    • pp.99-105
    • /
    • 2010
  • 목 적: 여러 통상적인 전뇌방사선치료 기법에서의 뇌와 수정체의 방사선 조사선량을 비교하고자 하였다. 대상 및 방법: 전뇌방사선치료를 위한 치료계획을 11명의 환자를 대상으로 컴퓨터단층촬영 영상을 이용하여 다음과 같이 수립하였다. 중심점이 조사영역의 중앙에 위치하고 가쪽눈구석(lateral bony canthus)에서 양측 빔이 평행한 통상적인 계획을 수립하고, 뇌에서 1 cm (렌즈에 대해서는 5 mm)의 여유로 차폐물을 생성하였다(P1). 이후 중심점을 가쪽눈구석으로 옮기고(P2), 조준기를 90도 회전시킨 후 5 mm 두께의 다엽조준기로 차폐를 하였다(P3). 각 환자의 모든 계획에서 P1의 중심점에 30 Gy를 처방하였다. 뇌와 수정체의 선량 지표들은 paired t-test를 이용하여 비교하였다. 결 과: 뇌의 $D_{max}$$V_{105}$는 P1에서 111.9%와 23.6%였다. 뇌의 $D_{max}$$V_{105}$는 P2와 P3에서 유의하게 감소하였는데, 그 값은 각각 107.2%와 4.5~4.6%였다(p<0.001). 수정체의 $D_{mean}$의 평균값은 P1에서 3.1 Gy, P2와 P3에서는 2.4~2.9 Gy였다(p<0.001). 결 론: 전뇌방사선치료 시 다른 복잡한 방법을 이용하지 않고, 중심점을 가쪽눈구석에 위치시키는 것만으로도 뇌와 수정체의 조사선량 측면에서 유리하였다.

소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구 (A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography)

  • 김현진;이효영;임인철;유윤식
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.161-169
    • /
    • 2016
  • 본 연구에서는 소아 두부 CT 검사에 있어서 피폭 방사선량을 경감할 수 있는 방법을 모색하고자 부산지역 병원들에서 시행된 년 간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고준위와 비교하여 분석함으로써 제안점을 도출하고자 하였다. 결과적으로 병원별 분류에서는 병원, 종합병원, 상급종합병원 순으로 권고량이 초과하는 것으로 나타났으며 연령별 분류에서는 2-5세 이하, 1개월-1세 이하, 6-10세 이하 순으로 권고량이 초과하는 것으로 나타났다. 스캔방식별 분류에서는 Helical, Axial, Volume방식 순으로 권고량이 초과하고 있었으며 스캔범위를 진단참고준위에 맞게 재설정한 결과 상급종합병원에서 재설정으로 인한 감소율은 11.68%, 종합병원에서 15.79%, 병원에서 20.66%로 초과율이 높게 나타났다. 그리고 환자선량 권고량 가이드라인을 벗어나지 않는 환자의 평균 스캔범위의 분석결과 1개월-1세 이하에서 $103.2{\pm}11.8mm$, 2-5세 이하에서 $110.5{\pm}14.5mm$, 6-10세 이하에서는 $117.8{\pm}17.2mm$로 나타났다.

악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석 (Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure)

  • 백종수;송재철;이희경
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.123-137
    • /
    • 2001
  • 6개의 건조두개골상의 중요한 방사선학적 계측점에 금속구를 위치시킨 후 3-D CT와 정모 및 측모 두부 방사선사진을 촬영하고 이를 바탕으로 만든 각각의 3차원 영상과 3차원 두부 방사선사진상의 각 계측점들이 3차원적으로 어느 정도의 정확성을 가지고 재현되는지를 알아보았다. 그리고 두 방법에 있어서의 계측점간의 거리계측을 실계측과 비교분석 함으로써 악안면부에서의 재현성과 정확성을 알아본 결과 다음과 같은 결과를 얻었다. 3-D CT와 3차원 두부 방사선사진상의 계측점들은 반복 계측시 각각 X축 방향으로 0.23 mm와 0.30 mm, Y축 방향으로 0.27 mm와 0.25 mm, 그리고 Z축 방향으로 0.27 mm와 0.31 mm의 표준편차를 보였다. 두 방법에서 모든 계측점이 0.5 mm 이하의 표준편차를 보였으며, 대부분의 계측점이 1 mm 이하의 범위를 보인 바, 두 방법 모두 통일한 건조두개골상의 계측점의 3차원적 위치 편차가 거의 없었다. 모든 계측항목에서 실측치와 3-D CT간의 차이는 평균 0.33 mm였으며, 실측치와 3차원 두부 방사선사진간의 차이는 평균 1.13 mm로 상대적으로 높게 나타났다. 가장 큰 차이를 보인 항목은 RGo과 LGo간으로 2.03 mm의 차이를 보였다. 그러나 두 방법 모두 모든 항목에서 실측치와 통계적으로 매우 높은 상관관계를 보였다(${\gamma}=0.976{\sim}1.000$, p<0.01).

  • PDF