• Title/Summary/Keyword: 커넥터 시일

Search Result 54, Processing Time 0.029 seconds

Practical Connector Patterns for Designing Component Frameworks (컴포넌트 프레임워크 설계를 위한 실용적인 커넥터 패턴)

  • 민현기;김수동
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.1
    • /
    • pp.43-53
    • /
    • 2004
  • Component-based development(CBD) has acquired a substantial acceptance in both academia and industry as an effective inter-organizational reuse technology. A component framework in product line engineering(PLE) which consists of related components, connectors and their semantics has a greater potential for reusability than components. In frameworks, components are glued with association, dependency and connections. Problems occur like affecting the implementation code of components when they are glued and replaced because the association and dependency relationships between COTS components which are acquired for application development do not match exactly. Especially, a connector may not only connect related components, but also mate partially-matched COTS components fit together. However, little has been studied to date about connectors that can be used practically. In this paper, we present a meta-model for connectors and show how a connector can be designed and implemented in practice. We propose five main patterns of connectors. Proposed major patterns Provide design guidelines for practical and efficient connector configuration based on component framework. And also, applying techniques and applied case studies of the major patterns show greatly increased applicability and reusability of the component without component modification.

A Priority Process Based Connector's Interaction considering Component Processing Time (컴포넌트 처리시간을 고려한 우산순위기반의 커넥터 상호작용)

  • Jeong Hwa-Young
    • Journal of Internet Computing and Services
    • /
    • v.6 no.2
    • /
    • pp.49-57
    • /
    • 2005
  • Connector's role between components is very important in the CBD(Component Based Development). The most connector has process ADL based rrethod was choosing FIFO method by component request. But in case many component's with various characteristics request It is difficult that this method operate efficiently, In this research, I did design and implement priority connector considering component's processing time, Also, I used Wright architecture for formal specification. Application result of proposed connector was spend more 388ms compares with existent FIFO method in total processing time. But this method could handle preferentially from components that have short processing time. Also, in case of component's waiting time in connector, existent FIFO method is 23323,1 ms and proposal method is 12731.27ms, So, proposal method could reduce waiting time for component process.

  • PDF

Tensile Load Transmission Capacity of H-shaped Beam by Stud Connectors (스터드 커넥터로 연결된 H형강보의 인장하중 전달성능)

  • Lee, Myung Jae;Choi, Wan Chol;Kim, Won Ki;Kim, Jae Hee;Lee, Sang Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.267-274
    • /
    • 2004
  • The objective of this study is to evaluate tensile load transmission capacity of H-shaped beam about design load by stud connector. The basic test of stud connecter was conducted and two specimens of full-scale size were tested under monotonic tensile loading condition. The parameter of tests is the size of the H-shaped beams. The results show that tensile load transmission capacity of H-shape beam about design load by stud connectors is excellent observing to the design code of steel structures of Architectural Institute of Korea.

Study on Fire Performance of Stud Connectors (스터드커넥터의 내화성능에 관한 연구)

  • Kim, Sung-Bae;Han, Sang-Hoon;Choi, Seng-Kwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2009
  • This research aims to conduct a pilot study for the in-fire performance of headed studs, commonly used in composite structures over the world. The robustness of the shear studs in fire appears to be a key element to govern the composite behaviour after a sudden local instability developed in structures such as trusses and cellular beams. In order to experimentally evaluate the residual strength of studs in fire, the standard push-out test was modified for a half of the original set-up to be equipped with a furnace. The adjustments allow the steel section to have a 3-sided exposure against fire. Under the Standard ISO fire, the modified push-out tests under loading were conducted to identify the failure mechanism of the studs in relation to temperature developments.

Anaysis of Small-sized Power Connectors for Mobile Device Batteries (모바일기기 배터리용 초소형 파워 커넥터 해석)

  • Lee, Keun-Myoung;Oh, Ung;Yoo, Sung-Kyu;Song, Byeong-Suk
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.101-109
    • /
    • 2015
  • As the number of smartphone users grows, number of applications and the expected overall functionality in a smartphone grow simultaneously. With ever-so increasing expectations comes intense competition to squeeze in myriads of functions in a limited space that is only getting 'slimmer' by the year. In order to achieve this, companies often decrease the size of components in smartphones - battery connectors in particular. While they may fit, smaller battery connectors have their disadvantages due to the heat generated by the high current flow in the circuits. In collaborating with Korea's leading battery connector manufacturers, this research presents current issues and design concepts that should be considered when engineers design power connectors based on their electrical and thermal analysis.

Study of the Acceptable Tolerances of a Window Hermetic Optical Connector (Window 밀폐형 광 커넥터의 허용 공차에 관한 연구)

  • Jeon, Woo-Sung;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.210-217
    • /
    • 2022
  • In this paper, a study is conducted on the acceptable tolerance of an alignment device to reduce the optical loss caused by the alignment tolerance of a window hermetic optical connector. To increase the transmission distance of optical signals and fiber-optic communication systems, it is necessary to maintain and improve the high optical efficiency of the connectors used to bond optical fibers. In the case of the window hermetic optical connector, the optical system is aligned through an alignment device. At this time, since the two connectors are used together, each component is fixed, and further alignment is impossible. The alignment tolerance of the housing system and pin used to align the optical system of the connector causes optical loss, leading to serious problems in the fiber-optic communication system. Thus, to find the acceptable tolerance required for manufacturing the optical-connector alignment device, tolerance analysis is performed on the components of the optical connector, such as the ball lens and the window. We also implement single-mode and multimode optical-connector systems, respectively. Based on the results, we determine an acceptable tolerance value for the alignment device.

A Method to Design Connectors to Resolve Partial Matching Problems in CBD (CBD의 부분 매칭 문제 해결을 위한 커넥터 설계 기법)

  • Min, Hyun-Gi;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.12
    • /
    • pp.1205-1216
    • /
    • 2005
  • Component-based Development (CBD) is gaining popularity as an effective reuse technology. Especially commercial-off-the-shelf (COTS) components are mainly for inter-organizational reuse, rather than intra-organizational reuse. One of the essential tasks in CBD is to reuse the right components that provide the functionality and interface required by component consumers. If candidate components provide a limited applicability and customizability, a component consumer cannot reuse the components in application development. To resolve this partial matching problem, we need smart connectors that fill the gap between candidate components and the specification of components required. Previous researches about smart connector describe only connector types to resolve mismatch problems. However, previous researches do not address the identification and design method to resolve the problems. In this paper, we suggest taxonomy of various mismatch problems to identify partial match problems between requirements of the application and components. We identify smart connector types and suggest a systematic process for designing smart connectors using the taxonomy. Therefore, components that have the problems can be used to develop applications.

트리즈를 이용한 전압측정용 탐침에 의한 전선피복 손상 방지 대책에 관한 연구

  • Gwak, Yun-Gi;Kim, Ho-Jong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.259-262
    • /
    • 2007
  • 현재의 전자제어 차량 정비에 있어서 각종 센서 및 엑츄에이터의 전압파형을 측정, 분석하여 원인을 진단하는 사례가 일반화 되어 가고 있다. 이러한 추세에 맞추어, 자동차 정비 실습 교육시 전압 파형 측정을 위하여 학생들이 직접 각 센서 및 엑츄에이터 커넥터에 탐침을 연결, 측정하고 있으며 이 과정에서 커넥터의 전선피복이 손상되는 사례가 빈번히 일어나고 있다. 본 논문에서는 트리즈의 6단계 창의성 기법을 적용하여 전선피복이 손상되는 원인을 찾아내고 혁신적인 해결책을 제시하였다.

  • PDF

광커넥터의 성능저하 요인에 관한 고찰

  • An, Seung-Ho;Jeon, Oh-Gon;Jung, Meong-Young;Choi, Tae-Gu
    • ETRI Journal
    • /
    • v.14 no.1
    • /
    • pp.108-117
    • /
    • 1992
  • 광통신 시스팀에서 신호접속용으로 사용되는 광커넥터의 결합기구 중 세라믹 페룰-슬리브의 정렬기구에서 발생하는 성능저하 현상을 다루었다. 성능저하 현상으로 페룰 단면연마시 발생하는 Vertex Eccentricty, 좌굴현상, 환경에 따른 탄성 및 응력의 변화, 마모, 피로파괴 등에 대한 이론적인 배경과 실험결과를 토대로 특성에 대한 영향을 분석하였다.

  • PDF

Moment Transmission Capacity of H-shaped Beam by Stud Connectors (스터드 커넥터로 연결된 H형강보의 모멘트 하중의 전달성능)

  • Lee, Myung Jae;Choi, Wan Chol;Lee, Sang Gu;Kim, Jae Hee;Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.639-648
    • /
    • 2003
  • The objective of this study is to evaluate in-plane and out-of-plane moment transmission capacity of H-shaped beams about design load by stud connector. Four specimens were tested under monotonic moment loading condition in each case to evaluate those. The parameter of tests is the size of the H-shaped beams. The results show that moment transmission capacity of H-shape beams in the serviceability limit state by stud connectors is excellent observing to the design code of steel structures of Architectural Institute of Korea.