• Title/Summary/Keyword: 캐비티 공진

Search Result 27, Processing Time 0.021 seconds

Design and Fabrication of Filter Banks for Implementation of Cavity Tunable Filter (캐비티 가변필터의 구현을 위한 필터뱅크 설계 및 제작)

  • Shin, Yeonho;Kang, Sanggee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.169-173
    • /
    • 2014
  • In order to satisfy user's requirements of needs for various services and to efficiently use of frequency, a communication system using one platform can support many communication services. Tunable filters must be used in the front end of broadband communication systems which provide and support various communication methods. In this paper we design and implement a filter bank to verify the feasibility of cavity tunable filter with the operation frequency of 800 MHz ~ 1600 MHz. The filter bank is composed of five bandpass filters and each bandpass filter has the same operation frequency band of the tunable filter. The implemented filter bank has the maximum insertion loss of 0.326 dB, the bandwidth of 37 MHz ~ 84 MHz, and the attenuation of minimum 19.974dB and mximum 37.812dB at the band edge ${\pm}60MHz$ over the operating frequency band.

Passively Mode-Locked 1.93-㎛ All-Fiberized Femtosecond MOPA Laser Using a Gold-Deposited Side-Polished Fiber (금 증착 측면연마 광섬유를 이용한 1.93㎛ 모드잠금 펨토초 전광섬유 MOPA 레이저)

  • Jung, Minwan;Koo, Joonhoi;Lee, Ju Han
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.340-345
    • /
    • 2014
  • We experimentally demonstrate the use of a gold-deposited side-polished fiber as a $2-{\mu}m$-band polarizing device to produce mode-locked pulses from a thulium/holmium-codoped fiber ring cavity. The mode-locking effect was induced by nonlinear transmission caused by the gold-deposited side-polished fiber, due to nonlinear polarization rotation of the oscillated beam within the fiberized cavity. It is also shown that ~558-fs pulses with a peak power of ~6.7 kW could readily be produced at a wavelength of 1935 nm through subsequent thulium/holmium-codoped fiber amplification, due to the higher-order soliton compression effect.

Study on Interior Noise Transfer Path Analysis by Tire Cavity Resonance (타이어 공동의 공명에 의한 차량 실내음 전달경로 연구)

  • Lee, Sang-Ju;Kang, Byun-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.129-133
    • /
    • 2005
  • Vibration transmitted through rolling tire is a major source of road noise in vehicle interior noise on the range of low frequency.($0{\sim}500Hz$) Among various road noises, tire cavity noise has very peak on $200{\sim}250Hz$. And generally it is generated by cavity resonance of tire. In this paper, tire cut-sample is used to calculate the tire cavity frequency. Cavity resonance frequency of tire is measured through vertical/tangential forces at load cell of axle using drum cleat impact. This method is useful to find cavity peak because measured forces do not have complex peaks. And changing the test conditions (air inflation, loads), tire cavity resonance characteristics are identified. Finally, vehicle interior noise is measured as tire/vehicle are changing. As difference of tire vertical force is bigger, interior noise level is higher at cavity frequency. Also we can assume that vehicle sensitivity is important factor at tire cavity noise.

  • PDF

Integrated Transceiver Module development at Ka-Band (Ka-Band의 집적화된 송수신 모듈 개발)

  • Kim, Wan-Sik;Jung, Yun-Man;Kim, Gye-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.5 s.43
    • /
    • pp.267-272
    • /
    • 2006
  • In this paper, an integrated and small Ka-band transceiver module has been developed for measuring distance at the radar systems. Oscillator of cavity type, The MMIC such as VCO, power amplifier, LNA, and mixer, and passive components are integrated on carriers and these are assembled in the transceiver module directly. The test result shows the output power of 21dBm and the noise figure of 5dB using developed transceiver module. Using developed FMCW transceiver module. We can measure the 60m range target by detecting the beat frequency and distinguish both earth and sky using radiometer signal. So we defined that the integrated module using MMIC had a good performance for the radar and radiometer at Ka-band.

  • PDF

Development of 4Hz Medical Ruby Laser System with Double Cavities using Multi-Resonant Converter (다중 공진형 컨버터를 이용한 이중 캐비티 구조의 4Hz 의료용 루비레이저 시스템 개발)

  • Lee, Jae-cheol;Zheng, Tao;Shengxu, Piao;Xu, Guo-Cheng;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1207-1211
    • /
    • 2015
  • Various laser systems have been widely used in almost all industrial technologies because they have high energy density, directivity and coherence. Recently the clinical application is becoming wider in medical parts such as incurable disease, diagnosis and so on. Generally, ruby laser beam has the greatest efficacy for removing tattoos, freckle and other skin problem. But current medical ruby laser system has the maximum repetition rate of 2Hz and optical output beam energy of 1J. Many medical doctors really want to have a high repetition ruby laser system because that can reduce the operation time. We investigated a new ruby laser system with high repetition rate of 4Hz using double cavities. Furthermore, we develop a new power supply system adopting zero voltage switching(ZVS) to minimize switching loss by LLC resonant converter designed as 2kW class.

Feasibility Study of the Application of Infinite Tube Probe in High Temperature Environment (고온 환경에서 무한 튜브 검출기의 적용에 관한 타당성 연구)

  • Kim, Hyeonjun;Ryu, Chulsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.108-119
    • /
    • 2020
  • Dynamic pressure sensor used in liquid rocket engine combustor and gas turbine is recess-mounted usually because it should work in high temperature environment. Although recess-mounted method can protect it from combustion gas in high temperature, tube resonance occurs in a tube-cavity system. To reduce it, the infinite tube probe(ITP) was introduced in this study. The ITP model suggested in previous literature was validated with experimental data and frequency response characteristics were analyzed. Guidelines for designing the ITP were suggested as frequency response profiles varied with geometric information and physical properties using this model.

Design of Broadband Spiral Antenna for Non-Linear Junction Detector (비선형 소자 탐지용 광대역 스파이럴 안테나의 설계)

  • Kim, Tae-Geun;Min, Kyeong-Sik;Lee, Kwang-Kun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • This paper presents a design of spiral antenna with broad bandwidth for non-linear junction detector(NLJD). An elliptical patch as radiating element located on center position of radiating surface, as well as the spiral elements on radiating surface was designed for broad bandwidth of spiral antenna. An antenna ground structure generating the multi resonance by spiral slit inserted on ground surface was also proposed. In order to realize high directivity and high gain of the proposed antenna, the cavity wall made of Fr4-epoxy and the metal cap were considered in design. As a result, the calculated gain of antenna with metal cap was improved about 3 dB with comparison of antenna without metal cap and the measured main beam directivity toward -z axis direction agreed well with calculation result. The measured axial ratio satisfied the circular polarization within -z axis ${\pm}45^{\circ}$ at design frequency bands and showed reasonable agreement with prediction.