Development of the Whole Body 3-Dimensional Topographic Radiotherapy System (3차원 전신 정위 방사선 치료 장치의 개발)

  • Jung, Won-Kyun;Lee, Byung-Yong;Choi, Eun-Kyung;Kim, Jong-Hoon;An, Seung-Do;Lee, Seok;Min, Chul-Ki;Park, Cham-Bok;Jang, Hye-Sook
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1999
  • For the purpose of utilization in 3-D conformal radiotherapy and whole body radiosurgery, the Whole Body 3-Dimensional Topographic Radiation Therapy System has been developed. Whole body frame was constructed in order to be installed on the couch. Radiopaque catheters were engraved on it for the dedicated coordinate system and a MeV-Green immobilizer was used for the patient setup by the help of side panels and plastic rods. By designing and constructing the whole body frame in this way, geometrical limitation to the gantry rotation in 3-D conformal radiotherapy could be minimized and problem which radiation transmission may be altered in particular incident angles was solved. By analyzing CT images containing information of patient setup with respect to the whole body frame, localization and coordination of the target is performed so that patient setup error may be eliminated between simulation and treatment. For the verification of setup, the change of patient positioning is detected and adjusted in order to minimize the setup error by means of comparison of the body outlines using 3 CCTV cameras. To enhance efficiency of treatment procedure, this work can be done in real time by watching the change of patient setup through the monitor. The method of image subtraction in IDL (Interactive Data Language) was used to visualize the change of patient setup. Rotating X-ray system was constructed for detecting target movement due to internal organ motion. Landmark screws were implanted either on the bones around target or inside target, and variation of target location with respect to markers may be visualized in order to minimize internal setup error through the anterior and the lateral image information taken from rotating X-ray system. For CT simulation, simulation software was developed using IDL on GUI(Graphic User Interface) basis for PC and includes functions of graphic handling, editing and data acquisition of images of internal organs as well as target for the preparation of treatment planning.

  • PDF

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

The Diagnostic Value of 99mTc DMSA Renal Scan SPECT Images in Addition to Planar Image in Children with Urinary Tract Infection (소아 요로 감염에서 99mTc DMSA 신스캔 평면영상에 추가된 SPECT 영상의 진단적 가치)

  • Yang Jea-Young;Yang Jung-An;Seo Jung-Wan;Lee Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.22-29
    • /
    • 2001
  • Purpose : 99mTc DMSA renal scan have been widely used not only for tile evaluation of renal scars but also for the diagnosis of acute pyelonephritis. Recent studies have shown SPECT images have higher accuracy than the planar images with some controversy. We evaluated the availability of the SPECT images adding to planar images for the diagnosis of acute pyelonephritis(APN) and renal scar in children with urinary tract infection (UTI). Methods : 130 children with UTI (260 kidney units) and 22 follow-up children (44 kidney units) were included between January 1, 1997 and July 31, 1999 at Ewha University Mokdong Hospital. Planar Anterior and posterior images and SPECT axial and coronal images of 99mTc DMSA renal scan were obtained with Starcam 4000-i U.S.A. GE at 3 hours after 99mTc DMSA I.V. injection. The data were analyzed by Chi square test after Yates's correction. Results : The detection rate of the acute pyelonephritis by SPECT images was 12.3$\%$ higher than that of planar images ($47.7\%\;vs\;35.4\%$) by the patient and 6.9$\%$ higher also ($31.9\%\;vs\;25.4\%$) by the kidney unit. 18 kidney units with negative planar images had focal defect in 10 kidney units (3.8$\%$) and multifocal defect in 8 kidney units (3.1$\%$) on SPECT images, but 1 kidney unit with positive planar image had negative SPECT image. SPECT images were superior to tile planar images in 17.3$\%$. identical in 82.3$\%$ and inferior in 0.4$\%$ to planar image. The detection rate of tile renal scars by SPECT images was 13.7$\%$ higher than planar images by the patient ($68.2\%\;vs\;54.5\%$) and 6.8$\%$ higher also ($43.2\%\;vs\;36.4\%$) by the kidney unit. SPECT images were superior to the planar images in 17.3$\%$ and identical in 82.3$\%$ to planar image. Conclusion SPECT images had shown higher detection rate and better image than planar images for the diagnosis of the acute pyelonephritis and the evaluation of the renal scars. (J. Korean Soc Pediatr Nephrol 5 : 22- 9, 2001)

  • PDF

The new explore of the animated content using OculusVR - Focusing on the VR platform and killer content - (오큘러스 VR (Oculus VR)를 이용한 애니메이션 콘텐츠의 새로운 모색 - VR 플랫폼과 킬러콘텐츠를 중심으로 -)

  • Lee, Jong-Han
    • Cartoon and Animation Studies
    • /
    • s.45
    • /
    • pp.197-214
    • /
    • 2016
  • Augmented Reality, virtual reality in recently attracted attention throughout the world. and Mix them mixed reality etc., it has had a significant impact on the overall pop culture beyond the scope of science and technology. The world's leading IT company : Google, Apple, Samsung, Microsoft, Sony, LG is focusing on development of AR, VR technology for the public. The many large and small companies developed VR hardware, VR software, VR content. It does not look that makes a human a human operation in the cognitive experience of certain places or situations or invisible through Specific platforms or program is Encompass a common technique that a realization of the virtual space. In particular, out of the three-dimensional image reveals the limitations of the conventional two-dimensional structure - 180, 360 degree images provided by the subjective and objective symptoms such as vision and sense of time and got participants to select it. VR technology that can significantly induce the commitment and participation is Industry as well as to the general public which leads to the attention of colostrum. It was introduced more than 10 related VR works Year 2015 Sundance Film Festival New Frontier program. The appearance VR content : medical, architecture, shopping, movies, animations. Also, 360 individuals can be produced by the camera / video sharing VR is becoming an interactive tunnel between two possible users. Nevertheless, This confusion of values, moral degeneration and the realization of a virtual space that has been pointed out that the inherent. 4K or HUD, location tracking, motion sensors, processing power, and superior 3D graphics, touch, smell, 4D technology, 3D audio technology - It developed more than ever and possible approaches to reality. Thereafter, This is because the moral degeneration, identity, generational conflict, and escapism concerns. Animation is also seeking costs in this category Reality. Despite the similarities rather it has that image, and may be the reason that the animation is pushed back to the VR content creation. However, it is focused on the game and VR technology and the platform that is entertaining, but also seek new points within the animation staying in the flat Given that eventually consist of visual images is clear that VR sought. Finally, What is the reality created in the virtual space using VR technology could be applied to the animation? So it can be seen that the common interest is research on what methods and means applied.

Brain Perfusion SPECT Imaging in Sturge-Weber Syndrome: Comparison with MR Imaging (Sturge-Weber 증후군의 뇌관류 SPECT 영상: 자기공명영상과의 비교)

  • Ryu, Jin-Sook;Choi, Yun-Young;Moon, Dae-Hyuk;Yang, Seoung-Oh;Ko, Tae-Sung;Yoo, Shi-Joon;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.56-64
    • /
    • 1996
  • The purpose of this study was to evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. $^{99m}Tc$-HMPAO or $^{99m}Tc$-ECD interictal brain SPECTs were performed on 5 pediatric patients with Sturge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Sturge-Weber syndrome.

  • PDF

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

Long-Term Trend Analysis in Nuclear Medicine Examinations (핵의학 영상 검사의 중장기 추세 분석 - 서울 소재 일개 상급 종합병원을 중심으로 -)

  • Jung, Woo-Young;Shim, Dong-Oh;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • Purpose Nuclear medicine was initially introduced in Korea in 1969 and widely applied to treat hyperthyroidism with $^{131}I$. Also, gamma camera was adopted in 1969 in the first place and its application has been growing continually in many ways. We analyzed long-term trend in nuclear medicine examinations for the last 2 decades. The purpose of this paper is to make predictions and to set both plans and directions on the development of nuclear medicine. Materials and Methods We analyzed the performance of nuclear medicine examinations and therapies performed in Asan Medical Center from 1998 to 2017. Results Results from the last 20 years regarding Bone scan, Renal scan, MUGA scan and $^{18}F$-FPCIT, Bone Mineral Density were on a increase. And Myocardium perfusion SPECT, Thyroid scan, Lung scan were on a decrease while $^{18}F-FDG$ PET maintained on a steady course. Until 2010 there was a positive performance with the therapy but after the excessive medical care in thyroid examination performance is at status quo. Key events such as a medical strike(2000), Middle-East Respiratory Syndrome (2015) influenced the overall performance of the therapy. Conclusion In order to promote a long-term growth in nuclear medicine examination and therapy, it is inevitable to respond to the changes in current medical environment. Furthermore, it is strongly suggested to put efforts to maintain and develop new examinations and clinical indicators.

Analysis of Behavioral Characteristics of Broilers by Feeding, Drinking, and Resting Spaces according to Stocking Density using Image Analysis Technique (영상분석기법을 활용한 사육밀도에 따른 급이·급수 및 휴식공간별 육계의 행동특성 분석)

  • Kim, Hyunsoo;Kang, HwanKu;Kang, Boseok;Kim, ChanHo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.558-569
    • /
    • 2020
  • This study examined the frequency of a broiler's stay in each area as stock density using an ICT-based image analysis technique from the perspective of precision livestock farming (PLF) according to the increase in the domestic broiler farms to understand the normal behavior patterns of broilers by age. The broiler was used in the experimental box (3.3×2.7 m) in a poultry house in Gyeonggi province. The stock densities were 9.5 birds/㎡ (n=85) and 19 birds/㎡ (n=170), respectively, and the frequency of stay by feeding, water, and rest area was monitored using a top-view camera. The image data of three-colored-specific broilers identified as the stock density were acquired by age (12, 16, 22, 27, and 29 days) for six hours. In the collected image data, the object tracking technique was used to record the cumulative movement path by connecting approximately 640,000 frames at 30 fps to quantify the frequency of stay in each area. In each stock density, it was significant in the order of the rest area, feeding, and water area (p<0.001). In 9.5 birds/㎡, it was at 57.9, 24.2, and 17.9 %, and 73.2, 16.8, and 10 % in 19 birds/㎡. The frequency of a broiler's stay could be evaluated in each area as the stock density using an ICT-based image analysis technique that minimizes stress. This method is expected to be used to provide basic material for developing an ICT-based management system through real-time monitoring.

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.