• Title/Summary/Keyword: 카메라 검정

Search Result 76, Processing Time 0.028 seconds

A Method for Efficient PTZ Camera Calibration and Integration (효율적인 PTZ 카메라 검정 및 통합 기법)

  • Jung, Sung-Hoon;Kim, Min-Hwan
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.264-265
    • /
    • 2012
  • PTZ 카메라는 팬, 틸트, 줌 기능을 사용해 넓은 영역을 관찰하거나 먼 거리에 있는 물체도 확대 관찰 가능하다는 장점이 있으나 카메라 검정에 어려움이 따른다. 본 논문에서는 PTZ 카메라의 효율적인 내 외부 변수 검정 방법을 제안한다. 구해진 내 외부 변수를 통해 멀리 떨어져 있는 두 대의 PTZ 카메라를 통합한 후 3차원 점 복원 실험을 통해 제안된 기법의 정확도를 확인한다.

  • PDF

Evaluation of Long-term Stability of Interior Orientation Parameters of a Non-metric Camera (비측량용 카메라 내부표정요소의 장기간 안정성 평가)

  • Jeong, Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.283-291
    • /
    • 2011
  • In case of metric cameras, not only fiducial marks but also various parameters related to camera lens are provided to users for the interior orientation process. The parameters have been acquired through precise camera calibration in laboratory by camera maker. But, in case of non-metric cameras, the interior orientation parameters should be determined in person by users through camera calibration with great number of control points. The interior orientation parameters of metric cameras are practically used for long time. But in case of non-metric cameras, the long-term stability of the interior orientation parameters have not been established. Generally, the interior orientation parameters of non-metric cameras are determined in every photogrammetric work. It's been an obstacle to use the non-metric camera in photogrammetric project because so many control points are required to get the interior orientation parameters. In this study, camera calibrations and photogrammetric observations using a non-metric camera have been implemented 25 times periodically for 6 months and the results have been analyzed. As a result, long-them stability of the interior orientation parameters of a non-metric camera is analyzed.

A Photogrammetric Network and Object Field Design for Efficient Self-Calibration of Non-metric Digital Cameras (비측정용 디지털 카메라의 효율적인 자체 검정을 위한 대상지 구성)

  • Oh Jae-Hong;Eo Yang-Dam;Lee Chang-No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.3
    • /
    • pp.281-288
    • /
    • 2006
  • Recent increase in the number of pixels of a non-metric digital camera encourages to use it for close-range photogrammetry such as modeling cultural asset and buildings. However, these cameras have to be calibrated far close-range photogrammetry application. For self-calibration, an appropriate pbotograrnmetric network and object field should be designed. In this paper, we studied the effect on self-calibration accuracy changes according to the change of the number of ground control points, dimensions of the ground control points, and the combination of images. We concluded that self-calibration with three photos including a vertical photo can give the stable accuracy of interior orientation parameters and 10 ground control points on a plane can give high accuracy for object reconstruction.

Geometric Calibration and Accuracy Evaluation of Smartphone Camera (스마트폰 카메라의 기하학적 검정과 정확도 평가)

  • Kim, Jin-Soo;Jin, Cheong-Gil;Lee, Seong-Kyu;Lee, Sun-Gu;Choi, Chul-Uong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.3
    • /
    • pp.115-125
    • /
    • 2011
  • The smartphones which have been recently are embedded with high resolution quality camera, assisted GPS, accelerometer, gyroscope and various sensors including magnetometer sensor that could be directly used for measurement. This study aims to suggest the possible application of smartphone camera providing high resolution images in terms of photogrammetry by calibrating it and assessing its accuracy. First of all, prior to the accuracy assessment of smartphone camera, camera calibration was conducted to correct lens distortion of each camera and the accuracy of image coordinates and object coordinates calculated by bundle adjustment during this procedure was analyzed. Also regarding three-dimensional positioning, result analysis depending on considering lens distortion coefficients was conducted, and finally relative accuracy of smartphone camera on metric camera was assessed. The result showed that in terms of distortion correction of smartphone camera, also higher order symmetric radial lens distortion coefficients should be considered, and three dimensional position determined by smartphone images was a little difference from that by metric camera. Therefore it is expected that smartphone images have huge possibility to be used for photogrammetry.

Development of Analytical Calibration Model of Camera in Photogrammetry (사진측정을 위한 카메라의 해석적검정모델 개발)

  • 박운영;이용희;손덕재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.3 no.2
    • /
    • pp.32-38
    • /
    • 1985
  • The purpose of this paper is to develope the analytical calibration model and to present its efficiency and problems for elimination of systematic errors. For this purpose, lens distortion in close-range photogrammetry is analized. From the obtained accuracy of object space coordinates, it is found that the calibration model included only $K_1$ term is effective for metric camera, and film deformation has to be considered not only in non-metric camera but also in metric camera.

  • PDF

Accuracy of Close-Range Industrial Photogrammetry Using CCTV Type CCD Camera (CCTV유형 CCD 카메라를 이용한 근거리 산업사진측량의 정확도)

  • 이진덕;최용진
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.3
    • /
    • pp.283-290
    • /
    • 2001
  • This paper demonstrates the performance of industrial precise measurement using the digital close-range photograrmmetric system based on a off-the-shelf CCTV-type CCD camera. The system was constructed with a CCD camera and a PC with a frame grabber, coupled with digital image mensuration and self-calibrating bundle adjustment techniques. An artificial fish reef with cubic shape was taken as an object for the application test of the system and the digital images were acquired on multi-station convergent network around the object. The geometric calibration of the CCD camera and the phototriangulation of the entire surface of the object was carried out simultaneously by means of self-calibrating bundle adjustment technique. Also the system comprising a high resolution still-video camera Kodak DCS, which high accuracy potential has been already established, were employed in similar network condition. Then the results from two different camera systems were compared in the accuracies of phototriangulation.

  • PDF

Evaluation for 3-D Reconstruction Accuracy Using Zoom-lens CCD Camera (줌 렌즈 CCD 카메라를 이용한 3차원 복원 정확도 평가)

  • 김성삼;정상용;박홍기;유환희
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.369-376
    • /
    • 2003
  • 최근 고해상력을 가진 줌 렌즈 CCD(Charge Coupled Device) 카메라가 출시되면서 디지털 영상을 쉽게 취득할 수 있게 되어 일상적인 활용에서부터 컴퓨터 시각(computer vision)이나 사진측량과 같은 전문적인 분야에 이르기까지 다양하게 응용할 수 있는 계기가 마련되고 있다. 현재 상용되고 있는 일반 줌 렌즈 CCD 카메라는 영상을 취득하는 데 많은 장점을 갖고 있으나 실제 영상 취득과정에서 다양한 줌의 이동으로 인하여 표정요소계산 및 카메라 렌즈 오차검정에 상당한 어려움이 발생하여 이에 대한 연구가 진행되어오고 있다. 본 연구에서는 기존에 비측량용 카메라에서 취득된 영상을 해석하는 기법으로 사진측량 분야에서 사용되어온 DLT(Direct Linear Transformation) 모델식과 컴퓨터 시각(computer vision)분야에서 카메라 검정 및 3차원 복원에 사용되고 있는 Tsai 모델식을 도입ㆍ적용하여 표정요소계산 및 3차원 복원정확도를 비교 분석하였다. 그 결과 Tsai 모델식에 의한 결과가 DLT 모델식에 의한 결과보다 정확도 및 안정성면에서 향상된 결과를 보여주고 있어서 Tsai 모델식에 대한 사용이 기대된다.

  • PDF

Analysis on 3D Positioning Precision Using Mobile Mapping System Images in Photograrmmetric Perspective (사진측량 관점에서 차량측량시스템 영상을 이용한 3차원 위치의 정밀도 분석)

  • 조우석;황현덕
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.6
    • /
    • pp.431-445
    • /
    • 2003
  • In this paper, we experimentally investigated the precision of 3D positioning using 4S-Van images in photograrmmetric perspective. The 3D calibration target was built over building facade outside and was captured separately by two CCD cameras installed in 4S-Van. After then, we determined the interior orientation parameter for each CCD camera through self-calibration technique. With the interior orientation parameter computed, the bundle adjustment was performed to obtain the exterior orientation parameters simultaneously for two CCD cameras using calibration target image and object coordinates. The reverse lens distortion coefficients were computed and acquired by least squares method so as to introduce lens distortion into epipolar line. It was shown that the reverse lens distortion coefficients could transform image coordinates into lens distorted image coordinates within about 0.5 pixel. The proposed semi-automatic matching scheme incorporated with lens distorted epipolar line was implemented with scene images captured by 4S-Van in moving. The experimental results showed that the precision of 3D positioning from 4S-Van images in photograrmmetric perspective is within 2cm in the range of 20m from the camera.

Evaluation for Geometric Calibration Accuracy of Zoom-lens CCD Camera (줌렌즈 CCD 카메라의 기하학적 검정 정확도 평가)

  • 유환희;정상용;김성삼
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.245-254
    • /
    • 2003
  • Zoom lenses CCD(Charge Coupled Device) cameras have many desirable features but appear to be geometrically unstable and diffcult to calibrate. It is well blown that the zooming camera parameters change with zoom lens position. This paper presents a comparative study of two approaches, namely, DLT(Direct Linear Transformation) introduced by Abdel-Aziz and Karara and the model proposed by Tsai, to evaluate the camera parameters of zoom lenses CCD camera and 3D positioning accuracy. As a result, the accuracy for 3D positioning using Tsai and DLT model is similar in both methods when the set of GCPs and the object are arranged in the same space. However, Tsai model is more stable than DLT in the case that the object is apart from the set of GCPs. Also, the further study for the parameters optimization of conventional DLT is needed to improve accuracy for 3D positioning.

Availability Evaluation For Generation Orthoimage Using Photogrammetric UAV System (사진측량용 UAV 시스템을 이용한 정사영상 제작 및 활용성 평가)

  • Shin, Dongyoon;Han, Jihye;Jin, Yujin;Park, Jaeyoung;Jeong, Hohyun
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.3
    • /
    • pp.275-285
    • /
    • 2016
  • This study analyzes the accuracy of ortho imagery based on whether camera calibration performed or not, using an unmanned aerial vehicle which equipped smart camera. Photgrammetric UAV system application was developed and smart camera performed image triangulation, and then created image as ortho imagery. Image triangulation was performed depending on whether interior orientation (IO) parameters were considered or not, which determined at the camera calibration phase. As a result of the camera calibration, RMS error appeared 0.57 pixel, which is more accurate compared to the result of the previous study using non-metric camera. When IO parameters were considered in static experiment, the triangulation resulted in 2 pixel or less (RMSE), which is at least 200 % higher than when IO parameters were not considered. After generate ortho imagery, the accuracy is 89% higher when camera calibration are considered than when they are not considered. Therefore, smart camera has high potential to use as a payload for UAV system and is expected to be equipped on the current UAV system to function directly or indirectly.