• Title/Summary/Keyword: 침투 길이

Search Result 158, Processing Time 0.022 seconds

Ability to Resist Chloride Ion Penetration and Dry Shrinkage Evaluation of Magnesium Phosphate Ceramics (인산마그네슘 세라믹의 염소 이온 투과 저항성 및 길이변화 특성에 관한 성능 평가)

  • Ko, Jeong-Won;Yang, Wan-Hee;Park, Dong-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.4
    • /
    • pp.341-348
    • /
    • 2017
  • The performance degradation of concrete pavement by winter deicer is very serious in Korea, and its maintenance and rehabilitation brings a high expense. Therefore, a suitable method for rehabilitation of such concrete pavement and repair material of proper performance are required. In this study, the properties of compressive strength, ability to resist chloride ion penetration, and properties of dry shrinkage of magnesium phosphate ceramics were assessed to evaluate its applicability as a repair material for concrete pavement in Korea. As a result, the mortar flow showed a normal level of 190 mm, but the viscosity was high and the self-flow ability was poor. The setting time was 12 minutes, leading very rapid-hardening, and thus a prompt work was required. The compressive strength of mortar was 38.4MPa in 2 hours, 73.8MPa in 24 hours, and 111.0MPa in 28 days, showing a significant level. As a result of the test to chloride ion penetration resistance, mortar showed 143 Coulombs, and concrete showed 172.6 Coulombs, which fell under very low level. The drying shrinkage of MPC concrete in 40 days was below $60{\times}10-6$, and comparing with normal cement concrete, it showed the level below 1/10 of other concrete to secure an excellent volume stability. As above, magnesium phosphate ceramics has excellent strength performance, chloride ion penetration resistance, and volume stability, and this in the future shall be used in construction under the consideration of working time or workability, requiring further improvement for such performance.

A Study on the Seepage Behavior of Embankment with Weak Zone using Numerical Analysis and Model Test (취약대를 가진 모형제방의 침투거동에 관한 연구)

  • Park, Mincheol;Im, Eunsang;Lee, Seokyoung;Han, Heuisoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.7
    • /
    • pp.5-13
    • /
    • 2016
  • This research is focused on the seepage behavior of embankment which had the weak zone with big permeability. The distributed TDR (Time Domain Reflectometer) and point sensors such as settlement gauge, pore water pressuremeter, vertical total stressmeter, and FDR (Frequency Domain Reflectometer) sensor were used to measure the seepage characteristics and embankment behavior. Also, the measured data were compared to the data of 2-D and 3-D numerical analysis. The dimension of model embankment was 7 m length, 5 m width and 1.5 m height, which is composed of fine-grained sands and the water level of embankment was 1.3 m height. The seepage behavior of measuring and numerical analysis were very similar, it means that the proper sensing system can monitor the real-time safety of embankment. The result by 2-D and 3-D numerical analysis showed similar saturation processing, however in case of weak zone, the phreatic lines of 2-D showed faster movement than that of 3-D analysis, and finally they converged.

Experiment for Reduction Effectiveness of Pollutants with the Improvement of Infiltration Ability in Vegetation Filter Strip (식생여과대내 침투능력 향상에 따른 오염물질 저감효과에 대한 실험)

  • Lee, Young-A;Choi, I-Song;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.183-190
    • /
    • 2007
  • Soil layer in vegetation filter strip is one of the very important factor for reduction of non-point pollutants by physical, chemical and biological reactions of it through infiltration process. This study was carried out to prepare more effective vegetation filter strip through modification of soil layer for river water quality improvement. Therefore, the main aims of this study are to compare and evaluate normal (straighten type) and modified (step type) vegetation filter strip, which make artificially change the soil layer to improve infiltration ability, through bench scale experiments. In the results of this study, vegetation filter strip of step type is much more highly reduction effectiveness of pollutants in surface flow compared with normal vegetation filter strip. In case of below effluent, however, it appeared that the vegetation filter strip modified soil layer showed lower reduction effectiveness of pollutants than the general vegetation filter strip. This result was judged because effluent through the vegetation filter strip of step type passed bigger size of aggregate or sand than the vegetation filter strip of straighten type. If we compare it as a definition of pollutant load to estimate total amount of reduced pollutants by vegetation filter strip, reduced pollutants load by step type showed higher than those by straighten type because below effluent amount relied on total effluent amount was higher at step type (4%) than at straighten type (2%). In conclusion, the vegetation filter strip of step type to improve infiltration effect is much more reduction effectiveness of pollutants than vegetation filter strip of straighten type.

Effect of Injection Angle and Length to Diameter Ratios on Drop and Penetration Characteristics in Cross-flow (아름속 횡단 기체 유동장에서 노즐 형상 변화와 분사각 변화가 액적크기와 침투거리에 미치는 영향)

  • Lee, Bong-Soo;Ko, Jung-Bin;Cho, Woo-Jin;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.51-58
    • /
    • 2006
  • The spray characteristics of liquid jet injected into subsonic cross-flow were investigated experimentally. Spray trajectories were captured using CCD camera. Droplet sizes were measured using PDPA and Image Express. The nozzle diameter was 0.5 mm, and its length-to-diameter ratios (L/D) ran$4.11{\times}10^6$ged from 1.0 to 6.0. Experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration length is decreased by increasing Weber number. At low injection angle(${\theta}$ < $90^{\circ}$), Weber number is dominant parameter for trajectories, but at high injection angle(${\theta}$ > $90^{\circ}$), L/D is dominant parameter for trajectories rather than Weber number.

Runoff Analysing Considering the Distribution of Conentration Time and Slope Length for a Small Basin (소유역의 홍수도달시간과 서면길이의 분포특성을 고려한 홍수유출해석)

  • 조홍재
    • Water for future
    • /
    • v.19 no.2
    • /
    • pp.139-148
    • /
    • 1986
  • The hydrologic response function in a small basin is expressed by the distribution function of slope length. The characteristics of topographical factors is represented to the concentration time, and the instantaneous unit hydrograph is derived as a hydrologic rsponse function by application of probobility density function. The averaging process of runoff characteristics within watershed was analyzed for a few small watershed where was split up the small basin itself. The method of calculation of the effective rainfall should play important roles in the transformation process from hydrologic response function to runoff hydrograph. In this paper, the Horton's infiltration quation is used as a method of calculation of effective rainfall, a new response function of runoff process is derived. The $\Phi$-index method and the infiltration method are tested by comparing the observed and estimated values.

  • PDF

Shielding effectiveness of an Aperture in Infinite Conducting plane Due to HEMP Incidence (무한 도체평판 개구에 입사하는 HEMP 파형에 따른 침투 전자파의 차폐효과)

  • Lim, Byoung-Jin;Seo, Hun-Wook;Lim, Sung-Min;Kim, Ki-Chai
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1647-1652
    • /
    • 2011
  • This paper presents the shielding effectiveness for the IEC 61000-2-9 standard when HEMP source penetrates through an aperture in a planar conducting plane of infinite extent. An integral equation is derived and solved by applying Galerkin's method of moments for calculating the electric shielding effectiveness. The electric shielding effectiveness is examined based on changing the aperture length and width. It is shown that the electric shielding effectiveness is suddenly decreases as the aperture width of 0.4 ~ 0.45${\lambda}$. It is also found that the penetrated electric field for the IEC 61000-2-9 incident field is different from the Bell Laboratory incident field, but the frequency characteristic of the electric shielding effectiveness becomes the same shape.

Numerical Studies for the Safety Estimation of Box-Culvert in Levee (수치해석을 이용한 하천제방 배수통문의 안정성 평가 연구)

  • Kim Jin-Man;Choi Bong-Hyuck;Oh Se-Yong;Kim Kyung-Min
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.479-486
    • /
    • 2006
  • In this study, 2-D seepage analysis is conducted for the evaluation of Box-Culvert installation, Cut-off Wall Length, permeability reduction of soil under the Box-Culvert effects on Levee Box-Culvert safety. The result of analysis it is obtained that the safety of seepage and slope stability of levee is declined by the installation of Box-Culver. And also obtained that the piping from poor compaction and cavity around Box-Culvert Is Prevented by the Cut-off wall installation below breast wall and levee toe, so it is recommended that the Cut-off Wall below breast wall and levee toe must be installed. And the Cut-off Wall installed below levee center is considered when the safety of piping is declined for the whole levee section. On the other hand, for the realistic analysis it is recommended that the 3-D seepage analysis is more suitable for the safety evaluation of Box-Culvert installed levee when it is considered that the saturated field is dispersed to the ground.

An Experimental Study on Chloride Ions Penetration of Mortar containing Si/Al Hybrid-Inorganic Salt (Si/Al 복합 무기염을 적용한 모르타르의 염소이온침투깊이에 대한 실험적 연구)

  • Khil, Bae-Su;Kim, Do-Su;Kang, Yong-Sik;Kim, Woo-Jae;Choi, Se-Jin;Kim, Sung-Su
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.417-418
    • /
    • 2009
  • As iron corrosion by means of penetration of chlorides resulted in a serious deterioration of seaside and landfill concrete construction, it is urgently necessary for seaside construction to acquire watertightness and resistance for chloride-attack. Hence in this study, Si/Al liquor type hybrid-inorganic salt which was very effective compound for improving resistance for chloride-attack applied to mortar and then evaluated resistance for chloride-attack with curing(7, 14, 28, 56 days).

  • PDF

A Study on the Security of Infrastructure using fiber Optic Scattering Sensors (광섬유 산란형 센서를 이용한 사회기반시설물의 보안에 관한 연구)

  • Kwon, Il-Bum;Yoon, Dong-Jin;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.499-507
    • /
    • 2004
  • We have studied tile detection techniques, which can determine the location and the weight of an intruder into infrastructure, by using fiber-optic ROTDR (Rayleigh optical time domain reflectometry) sensor and fiber-optic BOTDA (Brillouin Optical time domain analysis) sensor, which can use an optical fiber longer than that of ROTDR sensor Fiber-optic sensing plates of ROTDR sensor, which arc buried in sand, were prepared to respond the intruder effects. The signal of ROTDR was analyzed to confirm the detection performance. The constructed ROTDR could be used up to 10km at the pulse width of 30ns. The location error was less than 2 m and the weight could be detected as 4 grades, such as 20kgf, 40kgf, 60kgf and 80kgf. Also, fiber optic BOTDA sensor was developed to be able to detect intrusion effect through an optical fiber of tells of kilometers longer than ROTDR sensor. fiber-optic BOTDA sensor was constructed with 1 laser diode and 2 electro-optic modulators. The intrusion detection experiment was peformed by the strain inducing set-up installed on an optical table to simulate all intrusion effect. In the result of this experiment, the intrusion effort was well detected as the distance resolution of 3m through the fiber length of about 4.81km during 1.5 seconds.

Effects of Compost Application on Soil Loss and Physico-Chemical Properties in Lysimeters (퇴비시용(堆肥施用)이 토양유실량(土壤流失量)과 토양이화학성(土壤理化學性)에 미치는 영향)

  • Yun, Bong-Ki;Jung, Pil-Kyun;Oh, Se-Jin;Kim, Sun-Kwan;Ryu, In-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.336-341
    • /
    • 1996
  • This study was conducted to investigate the effects of compost application on the soil loss and physico-chemical properties at the slope land from 1990 to 1991. Lysimeters with 15% slope. 5m slope length. 2m width and 1.2m depth were constructed in 1984 and filled with sandy loam, loam, clay loam. and clay soils. Treatments were bare soil, compost(1.5ton/10a) and non-compost with soybean-barley cropping system from 1984. Losses of soil were increased with the order of sandy loam, clay, loam and clay loam. Run-off was increased with the order of sandy loam, loam, clay loam and clay, but leachate was decreased with the same order. Compost treatments decreased 33.6-44.6% of soil loss and 17.0-24.0% of run-off but increased 17.1-33.7.% of leachate as compared with the non-compost treatments. The amount of soil loss was positively correlated with the amount of run-off by Y = 12.125+0.063X (r=$0.970^{**}$)and negatively correlated with the leachate by Y=43.425-0.096X(r=$-0.917^{**}$). The application of compost increased soil pH, OM, CEC and extractable cations. Application of compost decreased bulk density but increased porosity, water stable aggregate and available water. These results provide that the compost application plays an important role in conserving soil and water, and improving soil physico-chemical properties.

  • PDF