• Title/Summary/Keyword: 침전효율

Search Result 425, Processing Time 0.024 seconds

Water Quality Variation and Removal Characteristics of Poliovirus by Biological Activated Carbon (BAC) and Ozone Treatment Process in Nakdong River. (낙동강 원수의 생물활성탄 및 오존처리공정에 따른 수질 변화 및 폴리오바이러스의 제거특성)

  • Jung Eun-Young;Park Hong-Ki;Lee You-Jung;Jung Jong-moon;Jung Mi-Eun;Hong Yong-Ki;Jang Kyoung-Lib
    • Journal of Life Science
    • /
    • v.15 no.5 s.72
    • /
    • pp.696-702
    • /
    • 2005
  • Ozonation is a disinfection technique of harmful mi-crobes commonly used in the treatment of drinking water. And Biological Activated Carbon (BAC) treatment also provides numerous benefits for drinking water utilities, including removal of micro- pollutants, improved treatment processes. The multiful-stage ozonation and BAC play roles as effective methods for removing several materials in raw water. Water quality variation in Nak dong river and the removal efficiency of viruses by ozonation-BAC process were investigated on pilot scale. During the period of survey, most of water quality parameters including $NH_{4}^{+}-N$ were highly improved after passing through the BAC. The removal efficiency of poliovirus type III in water treatment process using pilot-plant,$ 99.6\% $ of viruses were removed by pre-ozonation, sedimentation and sand filteration process, $ 100\% $ were removed after in BAC filteration step. In the removal survey of viruses by ozonation, ap-proximately $ 61.1\% $ or polioviruses were inactivated by ozone of 0.4 mg/l within 5 min. and $ 100\% $ were inactivated by ozone of 0.8 mg/l over 10 min.

Robust Plan Generation and Dynamic Execution for Intelligent Web Service (지능적인 웹서비스를 위한 강건한 계획 생성과 동적 실행 방법)

  • Hwang, Gyeong-Sun;Lee, Seung-Hui;Lee, Geon-Myeong
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.320-323
    • /
    • 2007
  • 웹 서비스와 같은 분산된 환경에서, 특정 서비스를 수행하기 위해서는 원격의 컴퓨터나 사이트상에서 다중 에이전트들의 협업을 통해 이루어진다. 이때 서비스는 여러 에이전트들의 복잡한 행위들에 의해 구성된다. 또한 지능적인 서비스를 위해서는 에이전트들의 상태정보, 목적정보, 그리고 계획정보 등을 이용한다. 특히 계획정보는 에이전트들이 일련의 행위들로 구성된다. 하지만 계획수립을 위한, 기존 연구들 대부분은 정적으로 기술된 서비스 명세와 초기상태 정보를 이용하여 특정 목표를 만족시키는 단일 계획 생성 방법을 연구해왔다. 따라서 계획수립이 실행 도중에 기대하지 않은 네트워크 장애나 방해 등으로 서비스 수행을 실패하는 경우, 그 계획은 무효가 되고 다시 계획을 생성 해야만 한다. 그러나 다시 계획을 생성하기 위해서는 많은 시간을 소비하게 될 뿐만 아니라 태스크 중복이 불가피하므로 매우 비효율적이다. 이 논문에서는 강건한 계획수립과 그 계획을 실행하기 위한 효과적인 방법을 제안한다. 즉, 계획수립의 재생성을 피하기 위한 방법으로 단일 계획수립 대신에 실행 가능한 다중 계획들로 표현된 강건한 계획을 생성하는 것이다. 강건한 계획의 행위들이 실행되는 동안, 각 단계마다 실행 가능한 행위를 선택한 후, 그 행위를 실행한다. 그러나 선택된 행위가 실행결과를 낼 수 없을 경우, 대체 가능한 서브 계획 경로를 선택하여 실행한다. 강건한 계획을 표현하기 위해 페트리 넷 기반의 방법을 제안한다. 강건한 계획 생성 방법에서는 이용 가능한 모든 계획들을 입력으로 사용한다. 그 계획수립 방법은 HTN 계획수립기로 잘 알려진 JSHOP2 계획수립기내에 구현하였다. 계획 실행 방법으로는 주어진 강건한 계획에 대하여 행위들이 직접 실행하수 있도록 한다.며 용량에 의존하는 양상을 보였다. $H_2O_2$에 의해 유발(誘發)된 DNA의 손상은 catalase와 deferoxamine에 의해 억제되었지만 DPPD는 억제시키지 못했다. 배기음(排氣飮)은 $H_2O_2$에 의해 유발(誘發)된 ATP의 소실을 회복시켰다. 이러한 실험결과 $H_2O_2$에 의해 유발(誘發)된 세포(細胞)의 손상(損傷)은 지질(脂質)의 과산화(過酸化)와는 다른 독립적인 기전에 의해 일어남을 나타낸다. 결론 : 이러한 결과들로 볼 때 Caco-2 세포(細胞)에서 배기음(排氣飮)이 항산화작용(亢酸化作用)보다는 다른 기전을 통하여 Caco-2 세포안에서 산화제(酸化劑)에 의해 유발(誘發)된 세포(細胞)의 사망(死亡)와 DNA의 손상(損傷)을 방지할 수 있다는 것을 가리킨다. 따라서 본 연구(硏究)는 배기음(排氣飮)이 반응성산소기(反應性酸素基)에 의해 매개된 인체(人體) 위장관질환(胃腸管疾患)의 치료(治療)에 사용할 수 있을 가능성(可能性)이 있음을 제시하고 있다.에 이를 이용하여 유가배양시 기질을 공급하는 공정변수로 사용하였다 [8]. 생물학적인 폐수처리장치인 활성 슬러지법에서 미생물의 활성을 측정하는 방법은 아직 그다지 개발되어있지 않다. 본 연구에서는 슬러지의 주 구성원이 미생물인 점에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며, 이는 한의학(韓醫學) 방제(方劑) 원리(原理)인 군신좌사(君臣佐使) 이론(理論)에서 군약(君藥)이 주증(主症)에 주(主)로 작용(作用)하는 약물(藥物)이라는 것을 밝혀주는

  • PDF

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

A Sludge Collector Selection Model by Life Cycle Cost Analysis (LCC분석에 의한 슬러지수집기 선정 모델)

  • Lee, Seung-Hoon;Woo, Yu-Mi;Lee, Sung-Rak;Koo, Kyo-Jin;Hyun, Chang-Taek;Hong, Tae-Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.175-184
    • /
    • 2006
  • This study focused on developing Life Cycle Cost(LCC) analysis model for selecting sludge collectors in wastewater treatment system and applying the model to a case study. Cost items are examined through literature review and historical data of a facility. Analysis period, discount rate, energy cost escalation ratio are assumed to reasonable level. Monetary evaluation is performed using historical data and estimations from vendors. Sensitive analysis is executed using Monte Carlo Simulation for assumed factors. Interviews with operators, vendors, constructors, managers are conducted to define factors which indicates ease of maintenance, ease of delivery, technical performance, efficiency, environmental friendship. Factors are representing technical and social factors. Results from LCC analysis and qualitative analysis are evaluate together with Weighted Matrix Evaluation Methods for optimum alternative of sludge collectors.

Concrete Release agent using Low Cost High Performance Photocatalyst Materials (저비용 고성능 광촉매를 활용한 콘크리트 이형박리제 개발)

  • Park, Jong-Pil;Hwang, Byoung-Il;Yoo, Byung-Hyun;Lee, Dong-gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.610-616
    • /
    • 2020
  • Recently, the application of a photocatalyst to road structures is being attempted to solve environmental problems caused by fine particulate matter and automobile exhaust. The purpose of this study was to develop a release agent with GST (low-cost, high-performance photocatalyst produced from wastewater sludge). For this, the method of mixing and dispersing GST with the release agent was used first, and the removal performance of nitrogen oxide (NOx) was then checked. The best performance without a precipitation reaction was achieved using a stabilizing agent at 20 % in an outdoor exposure test for four weeks. The NO and NOx removal rate of the specimen demolded by applying the GST release agent developed in this study showed excellent effects of 200 to 400 % compared to the Plain material. To increase the performance of the GST release agent, it is necessary to improve the dispersibility of GST in the release agent and increase the amount of the nano-sized photocatalyst. In addition, the use of GST release agent in road structures and exposed concrete is expected to increase the NOx removal efficiency.

The Characteristics of Biopellet Produced Upon Reactor Configuration in UASB System (UASB 공법에 있어서 반응조의 형상변화에 따른 입상슬러지의 특성에 관한 연구)

  • Min, Kyung Sok;Ahn, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.679-688
    • /
    • 1994
  • Physicochemical and morphological characteristics of biopellets produced in "control" and modified UASB reactor were investigated to compare the reactor performance with regard to the hydrogen partial pressure. The characteristics of biopellet produced in modified UASB reactor operated with high hydrogen partial pressure were better than those of "control" reactor operated with relatively lower hydrogen partial pressure, therefore the hydrogen partial pressure effected greatly on the formation and stability of the biopellet. Furthermore, pellets from the UASB system with modified settler showed a better settleability and biomass holding capacity. The chemical composition of biopellet was distinctively different from that of common bacterial formula, $C_5H_7O_2N$. Biopellets was composed the large fraction of nitrogen in comparison with common anaerobic microbes. These results implicated the existence possibility of polypeptide-type extracellular polymer. The morphological characterization with SEM showed that microorganisms observed at surface of biopellet produced in modified UASB reactor operated with high $P_{H_2}$ condition were very similar in shape and size to the Methanobrevibactor arboriphilus-$H_2$ utilizing methanogen. The microorganisms was distinguished from those of "control" reactor operated with low $P_{H_2}$ condition. From these results, it could be explained the hydrogen partial pressure effects on pelletization mechanism.

  • PDF

전기유동유체(ERF)를 이용한 지능구조물 시스템의 구성 및 응용

  • 최승복;박용군
    • Journal of KSNVE
    • /
    • v.5 no.3
    • /
    • pp.275-283
    • /
    • 1995
  • 본 글에서는 지능구조물의 개념설명과 더불어 ERF의 특성, ERF를 함유란 함유 한 지능구조물 시스템의 구성, 동적 모델링과 진동제어 그리고 그 응용성에 관한 연구 현황과 방향에 대해 살펴보았다. 설명한 바와 같이 지능구조물은 새로운 차원의 신생 하는 첨단분야로서, 소음 및 진동에 관련된 무한한 잠재력과 다양한 응용성으로 미루 어 볼때 아주 매력적인 연구 분야이다. 그러나, 여러 응용 시스템의 상품화 단계로의 도약에 있어서 각 시스템 구성 요소 분야별 해결해야할 연구 사항들이 있다. 먼저, 액추에이팅을 수행하는 ERF 자체의 내구성 문제로서 고온에서 ERF의 효과 하락과 장시간 사용시 ERF에 의한 마멸, 고체 입자의 침전에 의한 초기 상태 불안정 등이 있다. 아울러 기존의 장치의 성능을 능가하기 위해 보다 큰 효과를 나타내는 새로운 차원의 ERF개발이 요구된다. 그리고 센서기술 분야에서는 호스트 재료에 보다 쉽게 결합이 되고 여러가지 형태의 요구조건을 만족시킬 수 있으며 외부 환경조건에 강건 하고 다양한 센서 개발이 요구된다. 또한, 보다 일번적인 동적 모델링을 통해 적용 시스템에 적합하고 강건한 제어기에 대한 연구가 진행되어야 한다. 마지막으로 능동 제어기를 실제로 구현하기 위한 호스트 재료 각 요소마다 센서의 설치, 페회로 피드백 시스템 장착, 상호간의 인터페이스 등의 기술 발전이 요구되며, 아울러 보다 효율적 인 시스템의 성능 특성을 실현할 수 있는 호스트 재료와 기계 메카니즘이 필요로 된다. 이상의 설명에서 알 수 있듯이 지능구조물에 대한 연구는 어느 한 분야에서만 아니라 기계, 전기전자, 토목, 물리, 재료과학 등 통합형식에 의한 접근 방향으로 추진되어야 할 것이다.서 세탁기의 진동 소음을 저감시키기 위해 진동 소음원에 대해 논술하고, 진동해석을 위해 컴퓨터 시뮬레이션 결과를 이용한 저진동 기술 개발에 대하여 기술하고자 한다.rotary piston)식 압축기는 약 20여년 전 부터 냉방용 압축기에서부터 널리 쓰이게 되었다. 약 10여년전부터 상용화 된 스크롤(scroll) 형 압축기도 현재 상대적으로 용량이 큰 가정용 냉방기를 중심으로 많이 쓰이고 있다. 스크류형 압축기는 보통 중대형 상업용에 주로 쓰인다. 해결하려 하였고, 수치해석은 피스톤의 운동을 배제한 단순화한 흡배기계의 정상상태 유동해석이 주를 이루어왔다. Taghaui and Dupont 등[5]은 KIVA코드를 사용하여 흡기포트와 연소실 그리고 밸브의 움직임을 동시에 고려한 수치해석을 도입하였다. 하지만 이들이 밸브의 운동을 고려하기 위해 사용한 이동격자는 격자점은 시간에 따라 변화하지만 그 격자의 수가 일정하게 유지되어 있어서 밸브의 완전개폐를 해석할 수가 없다. 강희정[6]은 단일 실린더와 단일 배기밸브를 갖는 문제로 단순화하여 피스톤과 밸브의 움직임을 고려하므로써 배기행정 후 소음이 어떻게 전파해 나가는가를 연구하였다. 본 연구에서도 최소밸브간격과 최대밸브간격 사이에서만 계산이 가능하나 흡기의 경우는 밸브가 닫힐 때 생기는 압력파가 중요하므로 실린더와 밸브사이에 벽면조건을 주어 밸브의 개폐를 모사하였다.술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS.

  • PDF

Sequential Washing Techniques for Arsenic-Contaminated Soils near the Abandoned Iron-Mine (폐 철광산 주변 비소로 오염된 토양에 대한 연속 세척기법의 적용)

  • Hwang Jung-Sung;Choi Sang-il;Han Sang-Geun
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.1
    • /
    • pp.58-64
    • /
    • 2005
  • Several tests were conducted to determine the optimum operational conditions of soil washing techniques for floe-forming arsenic-contaminated soils, collected from D abandoned Iron-mine in Korea. The optimum cut-off size was 0.15 mm $(sieve\;\#100)$, about $94\%$ of the mass of soils. Both sodium hydroxide and hydrochloric acid were effective to remove arsenic and the optimum mixing ratio (soil [g] : washing solution [mL]) was 1:5 for both washing agents. Arsenic concentrations, determined by KST Methods, for the dried floe solids obtained from flocculation at pH 5-6 were $990\~1,086\;mg/kg$ dry solids, which were higher concentrations than at the other pH values. Therefore, batch tests for sequential washings with or without removing floc were conducted to find the enhancement of washing efficiencies. After removing floe with 0.2 M HCl, sequential washings of 1 M HCl followed by 1 M NaOH showed the best results (15 mg/kg dry soil). The arsenic concentrations of washing effluent from each washing step were about $2\~3\;mg/L$. However, when these acidic and basic effluents were mixed together, arsenic concentration was decreased to be less than $50\;{\mu}g/L$, due to the pH condition of coagulation followed by precipitation for arsenic removal.

Antibacterial and Mechanical Properties of Glass Ionomer Cements Containing Functionalized Multi-wall Carbon Nanotube(MWCNT) (기능화 다중벽 탄소나노튜브를 첨가한 글라스아이오노머 시멘트의 항균효과 및 기계적 성질)

  • Jeong, Mi-Ae;Kim, Dong-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.300-306
    • /
    • 2017
  • The purpose of this study was to investigate the antibacterial effect of functional multiwall carbon nanotube (MWCNT) on the conventional glass ionomer cement(GIC). The MWCNT was incorporated into a commercial powder at 0.125, 0.25, 0.5 and 1.0 wt%. Specimens for vickers hardness(VHN) disks(Ø$10mm{\times}2mm$) each were prepared. Indention were made using a load of 200 N and 20 s dwell on four specimens for each distilled water storage time 1d, 7d, and 14days. The antibacterial effects using agar diffusion test with S. mutans and S. aureus. The diameters of the inhibition zones produced around the materials were measured. The results revealed that all the vickers hardness values were increase significantly with incubation time(p<0.05). Regarding the antibacterial effect for S. mutans, all the tested groups showed a slightly higher value not significantly with the control group(p<0.05). However S. aureus statistical analysis indicated a significant difference for antibacterial agents between control and MWCNT containing 0.25 wt%(p<0.05). These results of this study provide that the conventional GIC with containing MWCNT show good antibacterial effect against and favorable mechanical properties. Further this study on the efficient functionalization of multiwall carbon nanotube will be needed.

A Study on the Comparison of Advanced Oxidation Reactions Including UV, $Fe^{2+}$, and $H_2O_2$ for the Degradation of Pentachlorophenol (UV와 $Fe^{2+}$, 그리고 $H_2O_2$를 조합한 고급산화 공정에서의 Pentachlorophenol의 분해 속도 연구)

  • Son, Hyun-Seok;Kim, Moon-Kyung;Zoh, Kyung-Duk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.846-851
    • /
    • 2007
  • This study was performed to compare and to examine the degradation efficiencies and degradation mechanism of pentachlorophenol(PCP) by UV, $UV/H_2O_2$, $Fe^{2+}$, $Fe^{2+}/H_2O_2$, and $UV/Fe^{2+}/H_2O_2$ processes. The pseudo-first order rate constant was compared in each process. The addition of $H_2O_2$ increased the rate constant by 13 times compared to the reaction with UV alone. The reaction rate in $Fe^{2+}$ reaction with PCP increased 4 times and 7.25 times by adding 180 mM $H_2O_2$ and 16 mM $H_2O_2$, respectively. Compared to that with $Fe^{2+}/H_2O_2$, the rate constant of the reaction with UV alone reaction increased 3.1 times. These results indicates the enhancement of reaction rate is closely related to the generation of OH radical. The degree of the iron sludge production observed in $Fe^{2+}/H_2O_2$ reaction was significantly reduced by irradiating UV in this process.